INSTRUCTIONS FOR:
INFRARED LASER DIGITAL THERMOMETER
MODEL: VS904
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
1.1 GENERAL SAFETY.
!WARNING! Ensure that Health & Safety, local authority and general workshop practice regulations are adhered to when using this
equipment.
!WARNING! DO NOT aim the laser beams at your or another person’s or animal’s eye and beware of reflections from mirrors or other
shiny surfaces.
"Familiarise yourself with the applications, limitations, and potential hazards of the thermometer.
"Keep the thermometer clean and in good condition.
"Protect the thermometer from the following:
- Electro-magnetic fields from engine components closer than 125mm.
- Static electricity.
- Thermal shock caused by large and/or rapid ambient temperature change.
- High temperatures.
#DO NOT get the thermometer wet or use in damp or wet locations or areas where there is condensation.
#DO NOT use the thermometer for any purpose other than that for which it is designed.
#DO NOT allow untrained persons (particularly children) to operate the thermometer.
#DO NOT operate the thermometer when you are tired or under the influence of alcohol, drugs or intoxicating medication.
!WARNING! The warnings, cautions and instructions discussed in this instruction manual cannot cover all possible conditions and
situations that may occur. It must be understood that common sense and caution are factors which cannot be built into this product,
but must be applied by the operator.
2. INTRODUCTION & SPECIFICATION
Fast and simple way to tackle diagnosis of engine and vehicle faults. VS904 detects energy emission in the infrared spectrum and
converts reading into a display of temperature. Features laser pointer to indicate area being sampled. Temperature is displayed on a
large LCD panel. Temperature can be shown in either °C or °F. Powered by 2 x AAA batteries (not included).
2.1 Specification
Range:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-35 to +365ºC (-31to +689ºF).
Resolution(-9.9~199.9°C): . . . . . . . . . . . . . . . . .0.2ºC/0.5ºF.
Response Time (90%): . . . . . . . . . . . . . . . . . . .1 second.
Operating Range: . . . . . . . . . . . . . . . . . . . . . . .0~50°C (32~122°F).
Accuracy, (Tobj* = 15 - 35°C, Tamb* = 25°C):. .±1.5°C (2.7°F).
Accuracy, (Tamb = 23 ± 3°C): . . . . . . . . . . . . .Tobj=0~365°C: ± 2.5% of reading or 2.5ºC (4.5°F) which ever is greater.
Tobj= -35~0°C: ± (2.5°C + 0.05°C).
Distance to Spot Diametr Ratio : . . . . . . . . . . . .8:1.
Emissivity: . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.95 fixed.
Laser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Class II.
Battery Life: . . . . . . . . . . . . . . . . . . . . . . . . . . .typically 14hours continuous use.
Battery: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 x AAA.
Dimensions: . . . . . . . . . . . . . . . . . . . . . . . . . . .166.4 x 339 x 63mm.
Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113 grams (including batteries).
Auto Shutdown: . . . . . . . . . . . . . . . . . . . . . . . .15 sec when idle.
Tobj* object temperature. Tamb* ambient temperature.
1.2 LASER SAFETY.
The VS904 utilises a Class II laser that emits low levels of visible radiation (i.e. wavelengths between 400 and
700 nanometres) which are safe for the skin but not inherently safe for the eyes. The Class II emission limit is
set at the maximum level for which eye protection is normally afforded by natural aversion responses to bright
light. Accidental eye exposure is therefore normally safe, although the natural aversion response can be
overridden by deliberately staring into the beam, and can also be influenced by the use of alcohol or drugs.
!WARNING! Do not look or stare into the laser beam as permanent eye damage could result.
$DO NOT direct the laser beam at any person’s (or animal’s) eyes as eye damage could result.
#DO NOT operate the thermometer when you are tired or under the influence of alcohol, drugs or intoxicating medication.
"Be aware that reflections of the laser beam from mirrors or other shiny surfaces can be as hazardous as direct eye exposure.
VS904 - 1 - 260607
01284 757500
01284 703534 sales@sealey.co.uk
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
www.sealey.co.uk
Web
email
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component
parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and
address, including postcode.
4.3 For all other errors, a generic error message “Er” is displayed. In the event of this
occurring, it will be necessary to reset the unit. To reset the unit, turn the
instrument off, remove the battery and wait at least one minute. Now reinsert the
battery and turn the unit on. Should the error message remain, contact your
authorised Sealey dealer for assistance.
5. BATTERIES
5.1 The VS904 incorporates a visual guide to the battery status:
“Battery OK”
Measurements are possible.
“Battery Low”
Battery needs replacing.
Measurements are possible.
“Battery Exhausted”
Measurements are not possible.
Replace battery.
5.2 When the “Battery Low” symbol appears, the batteries should be replaced immediately with two batteries which are
located under the cover on the front of the handle grip.
NOTE: It is important that the unit is off before the batteries are replaced. A malfunction could occur if this precaution
is not taken. Be sure to dispose of the batteries safely and in accordance with local laws regarding potentially hazardous
waste.
4. LCD ERROR MESSAGES
4.1 “Hi” or “Lo” will be displayed when the temperature being measured is outside the
range of the instrument. (See Specification, section 2.)
4.2 “Er2” is displayed when the unit is exposed to rapid changes in ambient
temperature.
“Er3” is displayed when the ambient temperature of the unit is below 0ºC (32°F)
or exceeds 50ºC (122°F). In both cases allow a minimum of 30mins for the unit to
stabilise and adapt to the working temperature.
6. STORAGE AND CLEANING
6.1 The sensor lens should be kept clean at all times. Care should be taken when cleaning the lens - it is an extremely
delicate piece of equipment. Use a cotton swab moistened with a little water or medical alcohol, allowing the lens to dry
fully before attempting to use the unit.
DO NOT submerge any part of the VS904.
6.2 The VS904 should be stored between -20ºC and +65ºC.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component
parts without prior notice.IMPORTANT: No liability is accepted for incorrect use of this product. WARRANTY: Guarantee is 12 months
from purchase date, proof of which will be required for any claim. INFORMATION: Call 01284 757525 for our catalogue & promotions. Leave
your full name, address & postcode.
01284 757500
01284 703534 sales@sealey.co.uk
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
www.sealey.co.uk
Web
email
3. OPERATION
3.1 To measure the surface temperature of an object/region, simply point the device at the object/region in question and press the
trigger.
NOTE! When the trigger is released the reading will be held for 15 seconds (HOLD will be displayed) and then the thermometer will
automatically shut down unless the trigger is pressed again.
3.2 ºC/ºF MODE.
3.2.1 To change the display from ºC to ºF (or visa versa), firstly turn the unit on by pressing the trigger. Now press the mode
button and the ºC or ºF symbol will be displayed, press again to cycle display between ºC or ºF.
Declaration of Conformity We, the sole importer into the UK, declare that the product listed here
is in conformity with the following standards and directives.
The construction file for this product is held by the Manufacturer and may be inspected, by a national
authority, upon request, to Jack Sealey Ltd.
For Jack Sealey Ltd. Sole importer into the UK of Sealey Professional Tools.
26th June 2007
INFRARED LASER DIGITAL
THERMOMETER 8:1
Model: VS904
EN 60825-1 Laser safety
93/68/EEC CE Marking Directive
2002/96/EC WEEE Directive
89/336/EEC EMC Directive
Signed by Tim Thompson
2.2 Distance & spot size
As the distance (D) from the object increases, the diameter (S) of the area measured by the unit becomes larger.
D
S
Displays highest reading for each session.
Current temperature reading.
°C or °F display.
Trigger released, laser reading held for fifteen seconds
or until trigger pressed again.
Battery state.
Environmental Protection.
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted,
taken to a recycle centre and disposed of in a manner which is compatible with the environment.
When the product is no longer required, it must be disposed of in an environmentally protective way. Be sure to dispose of
the batteries safely and in accordance with local laws regarding potentially hazardous waste.
2.3 Emissivity
2.3.1 Emissivity is a term used for the ability of a surface to radiate energy. Most (90% of typical applications) organic materials and
painted or oxidised surfaces have an emissivity of 0.95 (pre-set in the thermometer).
2.3.2 Inaccurate readings will result from measuring shiny or polished surfaces. To compensate, cover the surface to be measured
with masking tape or flat black paint.
2.3.3 Allow time for the tape to reach the same temperature as the material underneath it. Measure the temperature of the tape or
painted surface.

Other Sealey Thermometer manuals

Sealey VS900.V3 User manual

Sealey

Sealey VS900.V3 User manual

Sealey VS909 User manual

Sealey

Sealey VS909 User manual

Sealey Auto Service Line VS904.V2 User manual

Sealey

Sealey Auto Service Line VS904.V2 User manual

Sealey VS904.V2 User manual

Sealey

Sealey VS904.V2 User manual

Sealey VS907 User manual

Sealey

Sealey VS907 User manual

Sealey VS905 User manual

Sealey

Sealey VS905 User manual

Sealey VS905 User manual

Sealey

Sealey VS905 User manual

Sealey Auto Service Line VS900.V3 User manual

Sealey

Sealey Auto Service Line VS900.V3 User manual

Sealey VS900.V2 User manual

Sealey

Sealey VS900.V2 User manual

Sealey VS906 User manual

Sealey

Sealey VS906 User manual

Sealey VS903 User manual

Sealey

Sealey VS903 User manual

Sealey VS940 User manual

Sealey

Sealey VS940 User manual

Sealey VS900.V4 User manual

Sealey

Sealey VS900.V4 User manual

Popular Thermometer manuals by other brands

ReliOn DIGITAL THERMOMETER instruction manual

ReliOn

ReliOn DIGITAL THERMOMETER instruction manual

Carrera 2432.8 Instructions for use and guarantee

Carrera

Carrera 2432.8 Instructions for use and guarantee

Maverick DT-09 instruction manual

Maverick

Maverick DT-09 instruction manual

GREISINGER GMH 175 operating manual

GREISINGER

GREISINGER GMH 175 operating manual

Extech Instruments EzSmart RHT3 quick guide

Extech Instruments

Extech Instruments EzSmart RHT3 quick guide

Traceable 4134 instructions

Traceable

Traceable 4134 instructions

Westfalia TM-902C instruction manual

Westfalia

Westfalia TM-902C instruction manual

Cosori CMT-R161S user manual

Cosori

Cosori CMT-R161S user manual

Platinet PITHG01 user manual

Platinet

Platinet PITHG01 user manual

Hanna Instruments HI 92840 instruction manual

Hanna Instruments

Hanna Instruments HI 92840 instruction manual

Reed Instruments R2320 instruction manual

Reed Instruments

Reed Instruments R2320 instruction manual

Flipkart XS-IFT001A user manual

Flipkart

Flipkart XS-IFT001A user manual

Velleman DVM77N quick start guide

Velleman

Velleman DVM77N quick start guide

ThermoWorks I.R.F.S. operating manual

ThermoWorks

ThermoWorks I.R.F.S. operating manual

MEDIAID THM010-HT001 user manual

MEDIAID

MEDIAID THM010-HT001 user manual

General Heat Seeker IRT207 quick start guide

General

General Heat Seeker IRT207 quick start guide

Lanaform Thermo-Hygrometer instruction manual

Lanaform

Lanaform Thermo-Hygrometer instruction manual

RayTek 3i Operator's manual

RayTek

RayTek 3i Operator's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.