manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. SECO-LARM
  6. •
  7. Lock
  8. •
  9. SECO-LARM SD-995C-D3Q User manual

SECO-LARM SD-995C-D3Q User manual

Other SECO-LARM Lock manuals

SECO-LARM SD-994C User manual

SECO-LARM

SECO-LARM SD-994C User manual

SECO-LARM E-941DA-600Q User manual

SECO-LARM

SECO-LARM E-941DA-600Q User manual

SECO-LARM E-946FC-600Q User manual

SECO-LARM

SECO-LARM E-946FC-600Q User manual

SECO-LARM SD-993B-SS User manual

SECO-LARM

SECO-LARM SD-993B-SS User manual

SECO-LARM SD-962H-8LAQ User manual

SECO-LARM

SECO-LARM SD-962H-8LAQ User manual

SECO-LARM CL-210M-U3BQ User manual

SECO-LARM

SECO-LARM CL-210M-U3BQ User manual

SECO-LARM SD-995A-D3Q User manual

SECO-LARM

SECO-LARM SD-995A-D3Q User manual

SECO-LARM E-941SA-300RQ User manual

SECO-LARM

SECO-LARM E-941SA-300RQ User manual

SECO-LARM E-941S 600DPSQ Series User manual

SECO-LARM

SECO-LARM E-941S 600DPSQ Series User manual

SECO-LARM SLI E-942FC-1K3SQ User manual

SECO-LARM

SECO-LARM SLI E-942FC-1K3SQ User manual

SECO-LARM Enforcer E-941SA-300 User manual

SECO-LARM

SECO-LARM Enforcer E-941SA-300 User manual

SECO-LARM ENFORCER SD-961A-36 User manual

SECO-LARM

SECO-LARM ENFORCER SD-961A-36 User manual

SECO-LARM E-942FC-1300 User manual

SECO-LARM

SECO-LARM E-942FC-1300 User manual

SECO-LARM SLI ENFORCER 1200-lb Electromagnetic Lock... User manual

SECO-LARM

SECO-LARM SLI ENFORCER 1200-lb Electromagnetic Lock... User manual

SECO-LARM SD-231-ND1Q User manual

SECO-LARM

SECO-LARM SD-231-ND1Q User manual

SECO-LARM SD-997B-1SQ User manual

SECO-LARM

SECO-LARM SD-997B-1SQ User manual

SECO-LARM E-941SA-1K2PD User manual

SECO-LARM

SECO-LARM E-941SA-1K2PD User manual

SECO-LARM SD-997A-GBQ User manual

SECO-LARM

SECO-LARM SD-997A-GBQ User manual

SECO-LARM E-942FC-600AR User manual

SECO-LARM

SECO-LARM E-942FC-600AR User manual

SECO-LARM E-941DA-600Q User manual

SECO-LARM

SECO-LARM E-941DA-600Q User manual

SECO-LARM SD-997C-GCQ User manual

SECO-LARM

SECO-LARM SD-997C-GCQ User manual

SECO-LARM E-941S-600DPSQ Series User manual

SECO-LARM

SECO-LARM E-941S-600DPSQ Series User manual

SECO-LARM SD-993B-SS User manual

SECO-LARM

SECO-LARM SD-993B-SS User manual

SECO-LARM SD-997A-DQ User manual

SECO-LARM

SECO-LARM SD-997A-DQ User manual

Popular Lock manuals by other brands

Magic 105 manual

Magic

Magic 105 manual

Gantner GAT NET.Lock 7020 System Installation, configuration & operation

Gantner

Gantner GAT NET.Lock 7020 System Installation, configuration & operation

Dorma Studio Classic Installation instruction

Dorma

Dorma Studio Classic Installation instruction

Securam ECSL-601 quick start guide

Securam

Securam ECSL-601 quick start guide

Sudhaus 3003 operating manual

Sudhaus

Sudhaus 3003 operating manual

Safety 1st 48517 user guide

Safety 1st

Safety 1st 48517 user guide

Pado FDS-10 user manual

Pado

Pado FDS-10 user manual

Esco systeQ Series installation instructions

Esco

Esco systeQ Series installation instructions

COMPX National D8951 instruction sheet

COMPX

COMPX National D8951 instruction sheet

secureo Key Box instruction manual

secureo

secureo Key Box instruction manual

Stock Loks C8713 instruction sheet

Stock Loks

Stock Loks C8713 instruction sheet

COMPX 1T-058 Information

COMPX

COMPX 1T-058 Information

Auslock T11 user manual

Auslock

Auslock T11 user manual

Stealth SAFES ShadowVault Instructions & Troubleshooting

Stealth SAFES

Stealth SAFES ShadowVault Instructions & Troubleshooting

Knox KeySecure 5 Admin & user guide

Knox

Knox KeySecure 5 Admin & user guide

Kwikset 48334/01 Quick installation guide

Kwikset

Kwikset 48334/01 Quick installation guide

Metra Electronics Door Access Terminal Combo Technical manual

Metra Electronics

Metra Electronics Door Access Terminal Combo Technical manual

Kilitronik miniK10m operating manual

Kilitronik

Kilitronik miniK10m operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Manual
SD-995C-D3Q
No-Cut Door Strike
Features:
43RG
Static strength – 1,500-lb (680kg)
Dynamic strength – 70lb-ft (9.68kg-m)
12/24 VDC Operating voltage
Tested to 250,000 cycles (UL Tested),
tested to 1,000,000 cycles (Factory Tested)
Low current draw: 300mA@12VDC,
150mA@24VDC
The SD-995C-D3Q is intended to be used with
UL Listed Exit Hardware
The SD-995C-D3Q shall not impair the intended
operation of an emergency exit
The SD-995C-D3Q shall not impair the operation
of panic hardware mounted on the door
Low profile: Strike is only 11/16" deep for
use with aluminum frames
Field selectable for fail-safe or
fail-secure operation
Mounting tabs included for mounting to
hollow aluminum & metal doors
Reversible non-handed design fits either
right-hand or left-hand doors
For indoor use only
NOTE: SD-995C-D3Q has no horizontal or
vertical adjustments.
SECO-LARM No-Cut Door Strike
2SECO-LARM U.S.A., Inc.
1x Door Strike 2x Electrical connectors 2x Wiring connectors
2x Mounting tabs 2x Wood screws 4x Machine screws
2x Machine screws (narrow) 2x Security screws 2x Anchor nuts
1x Manual
Model SD-995C-D3Q
Operating voltage 12/24 VDC
Current draw 12VDC 300mA
24VDC 150mA
Latch throw 9/16" (15mm)
Keeper width 17/16" (36mm)
Static strength 1,500-lb (680kg)
Dynamic strength 70lb-ft (9.68kg-m)
Endurance 250,000 cycles (UL Tested), 1,000,000 cycles (Factory Tested)
Operating temperature 32°~120° F (0°~49° C)
Operating humidity 0~85%
Dimensions 47/8"x11/4"x11/16" (124x32x27.5 mm)
Specifications:
Note: Not all parts will be used in every installation
.
Parts List:
Dimensions:
1. Using a flathead screwdriver, unscrew and remove
the screw cap to access the field-selectable plug.
2. For fail-safe operation, rotate the field-selectable plug
so that "1" is facing up.
3. For fail-secure operation, rotate the field-selectable
plug so that "2" is facing up (Default).
4. Replace the field-selectable plug in the correct
orientation and screw the screw cap back into place.
Selecting Fail-Safe or Fail-Secure:
17/16"
(36mm)
11/4" (32mm)
47/8"
(124mm)
11/16" (27.5mm)
31/8"
(79mm)
33/8"
(85mm)
41/8"
(105mm)
Field-selectable Plug
Screw Cap
SECO-LARM No-Cut Door Strike
SECO-LARM U.S.A., Inc. 3
1. Measure the latch line (see Fig. 1).
a. Measure the distance between the face of the door
jamb and the face of the door latch. This is the
vertical latch distance.
b. Measure the vertical latch distance on the door jamb
from the face of the door jamb.
At that point, draw a vertical line. This is
the latch line.
2. Measure the center line (see Fig. 2).
a. Measure the distance from the floor to the center of
the door latch. I
g
nore the location of the deadlatch pin
when taking measurements.
b. Measure the same distance as above along the
inside of the door jamb. This is the center line.
3. Align the included mounting template to the latch and
center lines (see Fig. 3).
4. To mount the strike where the hollow door frame material
is unsuitable for mounting, install the provided mounting
tabs (see Fig. 4).
5. Before installing the door strike, program for either
fail-safe or fail-secure operation. See "Selecting
Fail-Safe or Fail-Secure," pg. 2.
6. Conceal all wires in the door frame. Use two of the
included machine screws to mount the unit to the
mounting tabs. Adjust as needed to ensure the door
closes smoothly (see Fig. 5).
7. Connect to power. See "Wiring Diagram," pg. 4.
NOTE: SD-995C-D3Q has no horizontal or
vertical adjustments.
Installation:
Fig.4
Fig.3
Fig.2
Fig.1
Fig.5
For 24VDC operation:
Door latch
Deadlatch pin
Door jamb
X
Vertical latch distance
Latch Line
For 12VDC operation:
12
V
24
V
Black Wire
Red Wire
White Wire
12VDC
24VDC
Wiring Diagram:
Center line
Door latch
Door jamb
SECO-LARM No-Cut Door Strike
4SECO-LARM U.S.A., Inc.
Connect the strike to a DC power supply.
Troubleshooting:
Door does not open when the
electric strike is activated
Dismount the strike and check that the wiring connector is
connected properly.
Ensure the wiring connector is connected to a 12 or 24VDC source.
Use a multimeter to test that the strike is receiving the proper
voltage and amperage. If it is not, it may be necessary to use
heavier gauge wires, or increase the output of the power supply.
Make sure the activation device (keypad or push-button switch) is
working properly.
Electric strike does not activate
Check that the door latch is operating properly, and replace
if necessary.
The position of the electric strike may need to be adjusted by
moving it or adding washers or shims.
Strike makes a buzzing sound
NOTICE: The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM
reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints. All trademarks
are the property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2018 SECO-LARM U.S.A., Inc. All
rights reserved.
LIMITED WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while
used in normal service for three (3) years from the date of sale to the original customer. SECO-LARM’s obligation is limited
to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This
Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repai
r
or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such
equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole
obligation of SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at
SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential
personal or property damage of any kind to the purchaser or anyone else.
SECO-LARM®U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA92606 Website: www.secolarm.com PITGW1
Phone: (949) 261-2999 | (800) 662-0800 Email: sales@seco-larm.com MI_SD-995C-D3Q_180306.docx
Electric Door Strike fo
r
Metal Doors
Door Strike with Horizontal
Adjustable Keeper Universal Door Strike
SD-995C SD-995A-A1Q SD-996C-NUQ
Also Available from SECO-LARM®:
NOTE: SD-995C-D3Q has no horizontal or vertical adjustments.
Surface-Mount Electric Rim Strike Mini No-Cut Electric Door Strike Electric Door Strike with
Vertical Adjustment
SD-998C-NUQ SD-991A-D1Q SD-996C-NUVQ