ELECTROMAGNETIC LOCK Installation Manual
.,O A U c
SECO-LARM U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
Page 1
Website: www.seco-larm.com
E-mail: sales
@
seco-larm.com
WARRANTY: SECO-LARM Electromagnetic Locks are warranted against defects in
material and workmanship while used in normal service for a period of one (1) year from the
date of sale to the original customer. Our obligation is limited to the repair or replacement of any
defective part if the unit is returned, transportation pre-paid, to SECO-LARM.
P TGW1
E941SA1K2PD.pmd
Also available:
HOW IT WORKS
When power is applied to the magnetic lock, it turns on the unit's powerful built-in electromagnet. This electromagnet is
attracted to the steel armature plate which is mounted on a door, holding the door fast against unauthorized entry. When
power to the magnetic lock is turned off, the electromagnet releases the armature plate, allowing the door to open. In
addition, the E-941SA-1K2PD has built-in LEDs to show electromagnet status, plus a status sensor to monitor whether the
door is securely closed, and a built-in adjustable-delay locking timer.
Installation Manual
E-941SA-1K2PD
1200 Pound Holding Force Electromagnetic Lock with status
sensor, LED status display and adjustable time delay.
SPECIFICATIONS
Power
Magnet Size
Armature Size
Holding Force
Status Sensor
Status LED (2-Color)
Timer Delay
Current Drain
Voltage Tolerance
Housing
Temperature
Weight
E-941SA-1K2PD
12/24 VDC
10½ x 15/8x 25/8in. (268 x 42 x 67 mm)
71/4x 5/8x 23/8in. (185 x 16 x 61 mm)
1200-lb (545kg)
Relay, 3A @ 12VDC
Locked - Green, Unlocked - Red
1~78 seconds
500mA @ 12VDC, 250mA @ 24VDC
± 10%
Aluminum
14° ~ 131°F (-10° ~ 55°C)
11-lb (5.0 kg)
NOTICE
The information and specifications printed in this manual are current at the time of publication.
However, the SECO-LARM policy is one of continual development and improvement. For this
reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is
also not responsible for misprints or typographical errors.
Copyright © 2010 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be
reproduced or copied, in whole or in part, without the written permission of SECO-LARM.
REGULAR MAINTENANCE
• Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and non-abrasive, non-
corrosive cleaner.
• Apply a light coat of a silicon lubricant to prevent rust. Wipe away the excess.
• Check that the armature plate is securely attached to the door, yet can pivot slightly around the armature screw.
• Check that the electromagnet is securely attached to the door frame.
TROUBLESHOOTING
Problem:
• Door does not lock
• Status LED is not
illuminated
Door locks, but can be
easily forced open
Delay in door
releasing
No relay output
Delay in door relocking
Possible cause:
No power
Poor contact between
electromagnet and armature
plate
Incorrect voltage setting
• A secondary diode was
installed across the
electromagnet
• No power
• Misalignment
• Check timer
Solutions:
• Check to make sure the wires are securely tightened to
the terminal block.
• Check that the power supply is connected and operating.
• Make sure the lock switch is wired correctly.
• Make sure the electromagnet and armature plate are
properly aligned.
• Make sure the contact surfaces of the electromagnet and
armature plate are clean and free from rust.
• Check the power leads with a meter, and make sure
12VDC or 24VDC is present.
• The electromagnet is fitted with a metal oxide varistor to
prevent interference, so do not install a secondary diode.
• Check that the power is connected and operating.
• Make sure the lock is aligned properly.
• Make sure the NO/NC/COM are wired properly.
• Make sure timer is adjusted to desired delay time.
SECO-LARM U.S.A., Inc.Page 4
SECOSECO
ECS O
SECO--
-
-L RLAR
L R
LARMM
M
M
E-941DA-600Q - 600-lb holding force, UL listed
E-941DA-600PQ - 600-lb holding force, bond sensor, LED, UL listed
E-941DA-1K2Q - 1,200-lb holding force, UL listed
E-941DA-1K2P - 1,200-lb holding force, bond sensor, LED, UL listed
E-941SA-600 - 600-lb holding force, UL listed
E-941SA-600PQ - 600-lb holding force, bond sensor, LED, UL listed
E-941SA-1200 - 1,200-lb holding force, UL listed
E-941SA-1K2PQ - 1,200-lb holding force, bond sensor, LED, UL listed
Single-Door Locks
Double-Door Locks
ELECTROMAGNETIC LOCK Installation ManualELECTROMAGNETIC LOCK Installation Manual
+
Status Sensor Output
N.O.
-
SPDT rated 3A @ 12VDC
}
Control
Device
Power
Supply
+
-
Relay
Status LED
*
Timer
Adjust
COM
N.C.
Voltage
Selection
Jumpers
Filler
Plate*
Standard
Mounting
"Z"
Bracket
For Inswing Doors
"L"
Bracket
*Note: may require more
than one filler plate.
MOUNTING THE E-941SA-1K2PD FIG.
1
FIG.
2
A. Drill holes for the mounting plate and
armature plate (see fig. 1 and 2) by
doing the following:
1. Fold the mounting template along
the dotted line.
2. Close the door. Find a mounting
location on the door frame near the
upper free-moving corner of the
door, as close to the corner of the
door frame as possible.
3. Place the template against the door
and frame.
4. Drill two holes in the door frame and
three holes in the door as indicated
on the template.
NOTE — A filler plate or an L-bracket or
Z-bracket (optional) may be required for
the electromagnet, depending on the door
frame. See fig. 1.
B. Mount the armature plate to the door
using at least two steel and one rubber
washer (fig. 2):
NOTE — Actual installation varies
according to door style.
1. Put one rubber washer between two
steel washers, and place them over
the armature screw between the
armature plate and the door. This
will allow the armature plate to
pivot slightly around the armature
screw in order to compensate for
door misalignment.
2. Tighten the sexnut bolt enough so
the armature plate can withstand
the force of someone attempting to
break down the door while the
electromagnet is engaged.
3. Do not tighten the armature plate
against the door. The plate must be
able to pivot around the armature
screw.
4. Make sure the anti-spin guides are
in the two guidepin holes.
C. Screw the mounting plate to the door
frame or optional bracket:
1. Screw the two short self-tapping
screws in the slotted holes of the
mounting plate and adjust the
position of the mounting plate so
that it and the armature plate form
a 90-degree angle.
2. Once the position is correct, use the
long self-tapping screws to
permanently mount the bracket.
3. Remove the two short screws.
D. Drill the cable access hole.
E. Mount the electromagnet to the door
frame (fig. 1) — Use the Allen
wrench to screw the socket-head
mounting screws through the bottom
of the electromagnet into the
mounting bracket.
F. Connect the power leads (fig. 3):
1. Open the electromagnet.
2. Run two power leads from the power
supply through the cable access
hole into the electromagnet.
3. Connect the power leads to the
terminal block.
4. Close the electromagnet.
G. Test the unit.
H. Insert the tamper caps into the
mounting screw access holes. This
should be the last step, as once the
tamper caps are in place, they will be
difficult to remove.
SECO-LARM U.S.A., Inc.Page 2 Page 3
Voltage Selection
12VDC
Magnet set for 12VDC
operation as supplied
from factory.
Position a jumper over
the two middle pins for
24VDC operation.
24VDC
FIG. 3: Status
Sensor Output -
Connect to an alarm
panel or other
monitoring device.
Status SensorOutput — Monitors whether
the protected door is open or closed.
N.C. — Door opened, red LED on.
N.O. — Door closed, green LED on.
Relay — 3A @ 12VDC.
* Status LED — Indicates
whether the magnetic lock
is locked or unlocked.
Green — Locked
Red — Unlocked
Off — No power
Adjustable Timer Delay — For
1~78 seconds, turn clockwise
to increase time. Timer starts
when power is applied.
E-941SA-1K2PD
SECO-LARM

This manual suits for next models

8

Other SECO-LARM Lock manuals

SECO-LARM SLI ENFORCER 1200-lb Electromagnetic Lock... User manual

SECO-LARM

SECO-LARM SLI ENFORCER 1200-lb Electromagnetic Lock... User manual

SECO-LARM E-941S-600DPSQ Series User manual

SECO-LARM

SECO-LARM E-941S-600DPSQ Series User manual

SECO-LARM Enforcer E-941SA-300 User manual

SECO-LARM

SECO-LARM Enforcer E-941SA-300 User manual

SECO-LARM SD-231-ND1Q User manual

SECO-LARM

SECO-LARM SD-231-ND1Q User manual

SECO-LARM SD-996C-NUVQ User manual

SECO-LARM

SECO-LARM SD-996C-NUVQ User manual

SECO-LARM E-941SA-600 User manual

SECO-LARM

SECO-LARM E-941SA-600 User manual

SECO-LARM SD-997C-GCQ User manual

SECO-LARM

SECO-LARM SD-997C-GCQ User manual

SECO-LARM SD-962H-8LAQ User manual

SECO-LARM

SECO-LARM SD-962H-8LAQ User manual

SECO-LARM SD-993B-SS User manual

SECO-LARM

SECO-LARM SD-993B-SS User manual

SECO-LARM SLI E-942FC-1K3SQ User manual

SECO-LARM

SECO-LARM SLI E-942FC-1K3SQ User manual

SECO-LARM E-946FC-600Q User manual

SECO-LARM

SECO-LARM E-946FC-600Q User manual

SECO-LARM E-941SA-300RQ User manual

SECO-LARM

SECO-LARM E-941SA-300RQ User manual

SECO-LARM E-941SA-80Q User manual

SECO-LARM

SECO-LARM E-941SA-80Q User manual

SECO-LARM E-942FC-1300 User manual

SECO-LARM

SECO-LARM E-942FC-1300 User manual

SECO-LARM ENFORCER SD-961A-36 User manual

SECO-LARM

SECO-LARM ENFORCER SD-961A-36 User manual

SECO-LARM Enforcer E-941DA-1K2P User manual

SECO-LARM

SECO-LARM Enforcer E-941DA-1K2P User manual

SECO-LARM SD-997A-DQ User manual

SECO-LARM

SECO-LARM SD-997A-DQ User manual

SECO-LARM ENFORCER 600-lb Electromagnetic Lock Series User manual

SECO-LARM

SECO-LARM ENFORCER 600-lb Electromagnetic Lock Series User manual

SECO-LARM E-941S 600 Series User manual

SECO-LARM

SECO-LARM E-941S 600 Series User manual

SECO-LARM E-942FC-600AR User manual

SECO-LARM

SECO-LARM E-942FC-600AR User manual

SECO-LARM SLI E-941SA-600 User manual

SECO-LARM

SECO-LARM SLI E-941SA-600 User manual

SECO-LARM SD-994C User manual

SECO-LARM

SECO-LARM SD-994C User manual

SECO-LARM SD-991A-D1Q User manual

SECO-LARM

SECO-LARM SD-991A-D1Q User manual

SECO-LARM CL-210M-U3BQ User manual

SECO-LARM

SECO-LARM CL-210M-U3BQ User manual

Popular Lock manuals by other brands

PROMIX Promix-SM306 operating manual

PROMIX

PROMIX Promix-SM306 operating manual

Equip 245400 quick guide

Equip

Equip 245400 quick guide

hager XEVS500 Replacement manual

hager

hager XEVS500 Replacement manual

Siegenia KFV GENIUS 2.1 PANIC Assembly instructions

Siegenia

Siegenia KFV GENIUS 2.1 PANIC Assembly instructions

Kaba E-PLEX 2000 Operation manual

Kaba

Kaba E-PLEX 2000 Operation manual

Abloy EL402 installation manual

Abloy

Abloy EL402 installation manual

COMPX CB098-198 instruction sheet

COMPX

COMPX CB098-198 instruction sheet

Gianni GK800 Series Installation instruction

Gianni

Gianni GK800 Series Installation instruction

NAPCO Networx ArchiTech Mounting and installation instructions

NAPCO

NAPCO Networx ArchiTech Mounting and installation instructions

Marvin INFINITY Inswing Service instructions

Marvin

Marvin INFINITY Inswing Service instructions

Falcon MA12 Series installation instructions

Falcon

Falcon MA12 Series installation instructions

National Cabinet Lock C8410 Dimensional drawing

National Cabinet Lock

National Cabinet Lock C8410 Dimensional drawing

Sargent ASSA ABLOY Profile Series installation instructions

Sargent

Sargent ASSA ABLOY Profile Series installation instructions

OEZ S-P50U06 Instructions for use

OEZ

OEZ S-P50U06 Instructions for use

Yale 5300LN Grade 2 installation instructions

Yale

Yale 5300LN Grade 2 installation instructions

Kwikset Powerbolt 250 Installation and user guide

Kwikset

Kwikset Powerbolt 250 Installation and user guide

BMB Beschlaege NOKY SOLO P quick start guide

BMB Beschlaege

BMB Beschlaege NOKY SOLO P quick start guide

StarTech.com LTLOCK4D quick start guide

StarTech.com

StarTech.com LTLOCK4D quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.