Magnetic Gate Lock Installation Manual Magnetic Gate Lock Installation Manual
Page 4
LIFETIME LIMITED WARRANTY: This SECO-LARM product is warranted against defects in material
and workmanship while used in normal service for the lifetime of the product. SECO-LARM’s obligation is limited to the repair or
replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. Under no circumstances will
SECO-LARM be responsible for any costs or charges for removal, installation, or reinstallation.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or
alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is
not operating properly as a result of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to repair or replacement only, at SECO-LARM’s
option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages
of any kind to the purchaser or anyone else. This lifetime limited warranty is for products sold and installed in the United States and
Canada. For all other countries the warranty is 1 (one) year.
SECO-LARM U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
Website: www.seco-larm.com
E-mail: sales
@
seco-larm.com
UL CERTIFICATION
The E-942FC-1300 and E-942FC-600 electromagnetic locks conform to UL/10B “Fire Tests of Door Assemblies” and UL/10C “Positive
Pressure Fire Tests of Door Assemblies” for swinging door assemblies. They are also classied in accordance with the Uniform Building
Code standard 7-2.
PITGW1
®
• For use with nearly all types of outdoor sliding and swinging electric gates.
• Holding force: - E-942FC-1300 — 1,200 pounds (591kg).
- E-942FC-600 — 600 pounds (271kg).
• Can be mounted horizontally or vertically.
• Housing dimensions:
- E-942FC-1300 — 8” x 21/2” x 19/16” (203 x 63 x 40 mm).
- E-942FC-600 — 8” x 111/16” x 19/16” (203 x 43 x 40 mm).
• Armature plate dimensions:
- E-942FC-1300 — 71/4” x 23/8” x 5/8” (185 x 61 x 16 mm).
- E-942FC-600 — 71/4” x 15/8” x 9/16” (185 x 41 x 14 mm).
• Power — 12VDC or 24VDC, with current draw of 500mA at 12VDC (250mA @ 24VDC).
• Cable — 6.5’ (2 meters), with dual-threaded conduit connector. (3’ [90cm] for E-942FC-600)
MOUNTING
A. Determine type of gate:
1. Single-swing gate (g. 2) — Gate swings on one end, and comes to rest on a xed gate post when closed. In this case, a typical
installation has the electromagnet xed to the gate post, and the armature connected to the free end of the gate with a Z-bracket.
2. Double-swing gate (g. 3) — Two gates swing in the same direction when activated. The electromagnet is xed to the free end
of one gate, and the armature is xed to the free end of the other via a Z-bracket. IMPORTANT:
a. A cover piece should be added to the Z-bracket to cover the electromagnet. This will help prevent unauthorized users from
prying the armature and the electromagnet apart.
b. Because of the cover piece, it is important to coordinate the swing of the gates to prevent the electromagnet from catching on
the cover piece. In this case, the gate with the armature should open before the gate with the electromagnet.
3. Sliding gate (g. 4) — The gate slides instead of swings away from a xed gate post. In this case, use L-brackets to mount the
electromagnet and the armature perpendicular to each other.
B. Mount the electromagnet (g. 5) — In most cases, the position of the electromagnet will determine the location of the armature
plate. Make sure there is space to run the cable.
Note: For hollow door headers or gate posts using blind nuts (see gure 6):
1. Tape the template to the appropriate location.
2. Drill four (E-942FC-1300) or two (E-942FC-600) 9.5mm (3/8”) holes, one for each short hex screw. IMPORTANT: The holes must
be 9.5mm (3/8”). No smaller, no larger.
3. Insert a blind nut in one of the 9.5mm (3/8”) holes.
4. Put the washer on the M6x30 screw. Then put the hex tool on the screw. Then turn the screw by hand into the blind nut.
5. Use a wrench or vice-grip to tightly hold the hex tool. Then use the included Allen wrench to slowly tighten the screw until it does
not turn any further. This compresses the blind nut so that it remains permanently xed in the hole.
6. Remove the screw.
7. Repeat steps 3) through 6) for the other blind nuts.
8.
Push hex screws into each of the screw holes in the electromagnet. Use the Allen wrench to tighten the screws into the blind nuts.
Page 1
NOTICE
Copyright © 2011 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or
in part, without the written permission of SECO-LARM. This material is subject to change without notice. SECO-LARM is not
responsible for misprints.
REGULAR MAINTENANCE
• Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and non-abrasive, non-corrosive
cleaner.
• Apply a light coat of a silicon lubricant to both contact surfaces and wipe away the excess to prevent rust.
• Check that the armature plate is securely attached to the door, yet can pivot slightly around the armature screw.
• Check that the electromagnet is securely attached to the gate or post.
TROUBLESHOOTING
E-942FC-600&1300_Manual.indd
Problem Possible cause • Solutions
Gate does not lock No power • Check to make sure the wires are secure
• Check that the power supply is connected and
operating
Gate locks, but can
be easily forced open
Poor contact between
electromagnet and
armature plate
Incorrect volate setting
• Make sure the electromagnet and armature plate
are properly aligned
• Make sure the contact surfaces of the electromagnet
and armature plate are clean and free from rust
Delay in gate
releasing
A secondary diode was
installed across the
elctromagnet
• THe electromagnet is tted with a vetal oxide
varistor to prevent interference, so do not install a
secondary diode
Installation Manual
E-942FC-1300
E-942FC-600
Electromagnetic Gate Locks
Magnetic Gate Lock Installation Manual Magnetic Gate Lock Installation Manual
ACCESSORIES
E-942F-1300/ZQ - “Z” bracket for E-942FC-1300
E-942F-1300/L - “L” bracket set for E-942FC-1300
E-942F-600/Z - “Z” bracket for E-942FC-600
E-942F-600/L - “L” bracket set for E-942FC-600
C. Mount the armature (g. 5) — Once the electromagnet is mounted, determine the correct position of the armature. Use the appro-
priate L-bracket or Z-bracket to position the armature so that it will lay against the electromagnet when activated. However, leave a
slight gap between the two so that the armature does not slam against the electromagnet when the gate is closed.
1. Put one rubber washer between two steel washers, and place them over the armature screw between the armature and the
bracket. This will allow the armature to pivot slightly around the armature screw in order to compensate for gate misalignment.
2. Make sure the guide pins are inserted into guide holes to prevent the armature from spinning.
3. Tighten the sexnut enough so the armature can withstand the force of someone attempting to pry the gate open while the electro-
magnet is engaged.
4. Do not tighten the armature against the bracket. The armature must be able to pivot around the armature screw.
D. Cover the installation — Use a steel box to make the installation more attractive as well as prevent unauthorized users from prying
the armature and electromagnet apart when engaged.
E. Run the wires — The goal is to keep as little of the wires exposed as possible.
1. Run the wires into an out-of-sight location as close as possible to the electromagnet. Run them inside hollow gate posts if
possible.
2. Use standard armored cable to prevent the wires from being cut between the electromagnet and the out-of-sight location.
F. Connect the wires:
G. Test the unit.
H. Insert the tamper caps into the mounting screw access holes of the electromagnet. This should be the last step, as once the tamper
caps are in place, they are difcult to remove.
Page 2 Page 3
1 x Electromagnet
1 x Armature plate
1 x Armature screw
3 x Large steel washers*
2 x Rubber washers*
1 x Sexnut bolt
4 x Mounting screws*
4 x Small washers*
4 x Tamper caps*
2 x Guide pins
1 x Hex key (Allen wrench)
4 x Blind nuts*
1 x Blind nut assembly set
(M6x30 screw, blind
nut, washer)
1 x Door spacer (tube)*
List of Parts
Note — When using the optional
Z-bracket, do not use the door spacer and
the sexnut bolt. Also, replace the armature
screw with the short armature screw
included with the bracket, or cover the
exposed end of the long screw with the nut.
**
*
FIG. 1 - Parts
Door
Spacer*
**
Sexnut Bolt* Guide
Pins
Rubber
Washer*
Armature
Plate
Armature
Screw** Electromagnet
Tamper Caps*
Mounting Screws*
Blind
Nuts* (for
hollow
door or
gate post,
see fig. 6)
Steel
Washers*
Note
— E-942FC-600
comes with 2 steel washers,
1 rubber washer, 2 mounting
screws, no small washers,
2 tamper caps, 2 blind nuts,
and no door spacer. Also
includes a black collar for the
armature screw.
Red
White
Black
Green
Red
White
Black
Green
+ 24VDC
-
GND
+ 12VDC
-
GND
IMPORTANT: Damage caused
by improper connection will
void warranty.
Wires are non-polarity.
}
12VDC
operation
24VDC
operation
Black Collar*
(E-942FC-600)
FIG. 6: Mounting the blind nuts
in a hollow door or gate post
Allen wrench must be
firmly seated while
turning hex screw.
Washer
Hold with wrench or vice
grip while turning hex screw.
Blind nut - Press into
9.5mm hole as shown.
Hex screw
(M6 x 30 thread)
Hex tool
Allen wrench
φ9.5mm
Door
Header
Hex screw
M6x30 - thread
FIG. 2 - Installation on a
single-swing gate
FIG. 3 - Installation on a
double-swing gate
FIG. 4 - Installation on a
sliding gate
FIG. 5 - Basic Installation

This manual suits for next models

1

Other SECO-LARM Lock manuals

SECO-LARM ENFORCER SD-961A-36 User manual

SECO-LARM

SECO-LARM ENFORCER SD-961A-36 User manual

SECO-LARM E-941S 600DPSQ Series User manual

SECO-LARM

SECO-LARM E-941S 600DPSQ Series User manual

SECO-LARM E-941SA-300RQ User manual

SECO-LARM

SECO-LARM E-941SA-300RQ User manual

SECO-LARM Enforcer E-941SA-300 User manual

SECO-LARM

SECO-LARM Enforcer E-941SA-300 User manual

SECO-LARM E-941SA-1K2PD User manual

SECO-LARM

SECO-LARM E-941SA-1K2PD User manual

SECO-LARM SD-995A-D3Q User manual

SECO-LARM

SECO-LARM SD-995A-D3Q User manual

SECO-LARM E-941DA-600Q User manual

SECO-LARM

SECO-LARM E-941DA-600Q User manual

SECO-LARM SLI ENFORCER 1200-lb Electromagnetic Lock... User manual

SECO-LARM

SECO-LARM SLI ENFORCER 1200-lb Electromagnetic Lock... User manual

SECO-LARM E-942FC-600AR User manual

SECO-LARM

SECO-LARM E-942FC-600AR User manual

SECO-LARM SD-997B-1SQ User manual

SECO-LARM

SECO-LARM SD-997B-1SQ User manual

SECO-LARM CL-210M-U3BQ User manual

SECO-LARM

SECO-LARM CL-210M-U3BQ User manual

SECO-LARM SD-993B-SS User manual

SECO-LARM

SECO-LARM SD-993B-SS User manual

SECO-LARM SD-997A-DQ User manual

SECO-LARM

SECO-LARM SD-997A-DQ User manual

SECO-LARM SLI E-942FC-1K3SQ User manual

SECO-LARM

SECO-LARM SLI E-942FC-1K3SQ User manual

SECO-LARM E-941DA-600Q User manual

SECO-LARM

SECO-LARM E-941DA-600Q User manual

SECO-LARM E-941SA-80Q User manual

SECO-LARM

SECO-LARM E-941SA-80Q User manual

SECO-LARM E-941SA-600 User manual

SECO-LARM

SECO-LARM E-941SA-600 User manual

SECO-LARM E-941SA-1K2PD User manual

SECO-LARM

SECO-LARM E-941SA-1K2PD User manual

SECO-LARM E-941S-600DPSQ Series User manual

SECO-LARM

SECO-LARM E-941S-600DPSQ Series User manual

SECO-LARM SD-997A-GBQ User manual

SECO-LARM

SECO-LARM SD-997A-GBQ User manual

SECO-LARM SD-997C-GCQ User manual

SECO-LARM

SECO-LARM SD-997C-GCQ User manual

SECO-LARM SD-995C-D3Q User manual

SECO-LARM

SECO-LARM SD-995C-D3Q User manual

SECO-LARM SLI E-941SA-600 User manual

SECO-LARM

SECO-LARM SLI E-941SA-600 User manual

SECO-LARM ENFORCER 600-lb Electromagnetic Lock Series User manual

SECO-LARM

SECO-LARM ENFORCER 600-lb Electromagnetic Lock Series User manual

Popular Lock manuals by other brands

Tecnosicurezza Pulse T6430 installation instructions

Tecnosicurezza

Tecnosicurezza Pulse T6430 installation instructions

Kaba SIMPLEX 900 Series instructions

Kaba

Kaba SIMPLEX 900 Series instructions

Ilockey F1 user manual

Ilockey

Ilockey F1 user manual

D&D Technologies LokkLatch Magnetic installation instructions

D&D Technologies

D&D Technologies LokkLatch Magnetic installation instructions

HPC KEKAB Series instructions

HPC

HPC KEKAB Series instructions

OEZ OD-FH123-VU Instructions for use

OEZ

OEZ OD-FH123-VU Instructions for use

Stanley QET320 installation instructions

Stanley

Stanley QET320 installation instructions

LEHMANN M610 operating instructions

LEHMANN

LEHMANN M610 operating instructions

Lowe & Fletcher 3786 User instructions

Lowe & Fletcher

Lowe & Fletcher 3786 User instructions

SCM Doublelock operating instructions

SCM

SCM Doublelock operating instructions

Stanley GS3-MT PIN installation guide

Stanley

Stanley GS3-MT PIN installation guide

Satel SZW-02 manual

Satel

Satel SZW-02 manual

Dexel SPIDER PS0161 quick start guide

Dexel

Dexel SPIDER PS0161 quick start guide

KF-LOCK DB-BT-15 installation instructions

KF-LOCK

KF-LOCK DB-BT-15 installation instructions

Westfalia 83 69 66 Original instructions

Westfalia

Westfalia 83 69 66 Original instructions

S&G Comptronic 6124 user guide

S&G

S&G Comptronic 6124 user guide

Trine 4100 Electric Strike installation instructions

Trine

Trine 4100 Electric Strike installation instructions

urmet domus 1086 quick start guide

urmet domus

urmet domus 1086 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.