DEHUMIDIFIER
OPERATION MANUAL
抽濕機
使用說明書

CONTENTS
IMPORTANT SAFETY INSTRUCTIONS .................................................................... 1
PART NAMES ............................................................................................................. 3
PREPARATION........................................................................................................... 5
OPERATION
START/STOP.......................................................................................................... 5
DEHUMIDIFY OPERATION.................................................................................... 5
HUMIDITY SELECTION ........................................................................................ 5
LAUNDRY OPERATION ........................................................................................ 6
INTERNAL DRY OPERATION ............................................................................... 6
MOLD CONTROL OPERATION ............................................................................. 6
SWING LOUVER.................................................................................................... 7
TIMER OPERATION............................................................................................... 7
CHILD LOCK .......................................................................................................... 7
HOW TO CHANGE VARIOUS SETTING ............................................................... 8
HOW TO DRAIN ......................................................................................................... 9
CARE AND MAINTENANCE ..................................................................................... 10
TROUBLESHOOTING............................................................................................... 11
SPECIFICATIONS...................................................................................................... 12
Thank you for purchasing this SHARP Dehumidier.
Please read this manual carefully before using the product.
This manual should be kept in a safe place for handy reference.
ENGLISH
①
④
②
③
Dry air
Damp air
Water Tank
Evaporator
Condenser
Dehumidify
In accordance with the principle of generating water droplets
when warm air with much moisture gets contact with cold
items, wet air is blown in a evaporator to remove moisture.
In the following cases, the compressor will stop and will not
dehumidify.
• When the room temperature is lower than 4°C or higher than 38°C.
• The 3 minutes when the Main Unit operated again in the following
to protect the Main Unit.
* Immediately after the power plug is inserted.
* Immediately after the Laundry Drying/
Dehumidifying operation is stopped.
• When the room temperature falls below 18°C, the compressor will
stop and “HIGH” air ow mode will operate for about 12 minutes once every 45 minutes to prevent frost
damage inside the Main Unit. (DEFROST mode / The DEFROST Indicator Light is turned on. )

EN-1
ENGLISH
A powerful dehumidi er with a high concentration of
Plasmacluster ions for cleaning, quick drying, and
deodorizing room-dried laundry
MOLD CONTROL OPERATION
It prevents the propagation of the mold by releasing Plasmacluster and dehumidi ed air into the room.
LAUNDRY Drying
Wide angle louver swings to both top and bottom / left and right wards and provides wide-area air ow.
MOLD Filter
It collects airborne mold through Mold lter and Pre-
lter.
Large Tank 4.6L
It realizes continuous dehumidi cation.
(more than approximate 6 hours. )
It prevents the propagation of the mold by releasing Plasmacluster and dehumidi ed air into the room.
1 2 3
Circulate Room Air
With High Air Volume Dehumidi cation Air Puri cation
Air Purify in
fewer than 50%
of humidity
Dehumidify in
more than 60%
IMPORTANT SAFETY INSTRUCTIONS
Always follow basic safety precautions
when using electrical appliances, including
the following:
WARNING –Always observe the following
to reduce the risk of electrical shock, re, or
injury:
• Read all instructions before using the Main
Unit.
• Use only a 220-240 volt outlet.
• This appliance is not intended for use
by persons (including children) with
reduced physical, sensory or mental
capabilities, or lack of experience and
knowledge, unless they have been given
supervision or instruction concerning
use of the appliance by a person
responsible for their safety. Children
should be supervised to ensure they do
not play with the appliance.
• If the power cord is damaged, it must be
replaced by the manufacturer, its service
agent, a Sharp authorized Service
Center or similarly quali ed persons in
order to avoid a hazard.
• Be sure to remove the power plug when
draining the water, before performing
maintenance, when removing and
attaching and replacing the lter and
when not using for a long time. Failure
to do so can cause a short circuit
resulting in electrical shock or re.
• Do not use the Main Unit if the power cord
or plug is damaged or if the connection to
the wall outlet is loose.
• Periodically remove dust from the plug.
• Do not insert ngers or foreign objects into
the air intake or air outlet.
• When removing the power plug, always
hold the plug and never pull on the cord.
Failure to do so can cause a short circuit
resulting in electrical shock or re.
• When removing the Main Unit, do not
damage the power cord with the casters.
Failure to do so can cause electric shock,
heat generation, or re.
• Be careful not to damage the power cord,
it may cause electric shock, excess heat or
res.

EN-2
IMPORTANT SAFETY INSTRUCTIONS
• Always operate the Main Unit in an upright
position.
• When moving the Main Unit, use the
handles on both sides. Do not move the
Main Unit when it is in operation.
• If the Main Unit is on easily damaged
ooring, an uneven surface, or thick-piled
carpet, lift it up when moving.
• When moving the Main Unit by its casters,
move it slowly and in a horizontal direction.
• Turn the Main Unit o and remove the
Water Tank before moving, take care not to
catch your ngers.
• Do not operate the Main Unit without the
Water Tank properly installed.
• Clean the exterior with a soft cloth only.
Do not use volatile uids or detergents.
The Main Unit surface may be damaged
or cracked with Benzene paint thinner or
polishing powder. In addition, the sensors
may malfunction as a result.
• Keep the Main Unit away from water.
• Be sure to wipe o any excess water on the
outside of the Water Tank.
• Do not shake the Water Tank with holding
the carrying handle.
• Avoid spilling water when removing or
cleaning the Water Tank.
• Do not remove the Float.
• Do not use the detergents for maintenance
of the Water Tank and Tank Cover. If cause
deformation, tarnishing, cracking (water
leakage).
• Do not scrub the Back Panel hard during its
maintenance.
INSTALLATION GUIDELINES
• Avoid locations where the sensors are
exposed to direct wind. Doing so can cause
the Main Unit to malfunction.
• Avoid locations where furniture, fabrics, or
other objects can come in contact with the
Main Unit and interfere with the intake and
outtake of air.
• Avoid locations where the Main Unit
is exposed to condensation or drastic
changes in temperature. Appropriate room
temperature is between 4 - 38°C.
• Place the Main Unit on a level and stable
surface with sucient air circulation. When
placed on heavy carpet, the Main Unit may
vibrate slightly. Place the Main Unit on a
level surface to avoid water leakage from
the Water Tank.
• Avoid locations that generate grease or
oily smoke. Doing so can cause the Main
Unit exterior to crack and the sensors to
malfunction.
• Do not remove the plug when your hands
are wet.
• Do not place the Main Unit near gas
appliances or replaces.
• Only a Sharp Authorized Service Center
should service this dehumidier. Contact
the nearest Service Center for any
problems, adjustments, or repairs.
• Do not operate the Main Unit in rooms
where aerosol insecticides are present. Do
not operate the Main Unit in rooms where
there is oily residue, incense, sparks from
lit cigarettes, or chemical fumes in the air.
Do not operate the Main Unit in places
where it may get wet, such as a bathroom.
• Be cautious when cleaning the Main Unit.
Strong corrosive cleansers can damage the
exterior.
• When carrying the Main Unit, rst remove
the Water Tank, and then hold the Main
Unit by the handles on both sides.
• Do not drink the water in the Water Tank.
• Do not expose the Main Unit to water.
Doing so can cause a short circuit or
electrical shock.
• Clean the Water Tank regularly. When the
Main Unit is not in use, dispose of the water
in the Water Tank. Leaving water in the
Water Tank can cause mold, bacteria, and
bad odors. In rare cases, such bacteria can
be a health hazard.
• Check for bent hose/falling height when
you want to drain continuous, and place the
hose where it will securely drain.
• Keep the temperature around the hose
above freezing point when using the hose.
Inner water may leak in the room and
dampen the furniture or may cause electric
shock/leakage, re.
NOTE - What to do if the Main Unit interferes
with radio or TV reception.
If the Dehumidier interferes with radio or
television reception, try one or more of the
following measures:
• Adjust or reposition the receiving antenna.
• Increase the distance between the Main
Unit and the radio or TV.
• Connect the equipment into an outlet on a
circuit dierent from that of the radio or TV
receiver.
• Consult the dealer or a qualied radio or
TV technician.
CAUTIONS CONCERNING OPERATION
• Do not block the air intake or air outlet.
• Do not place the Main Unit near or on hot
objects, such as stoves or heaters, or where
it may come into contact with steam.

EN-3
ENGLISH
MAIN UNIT
PART NAMES
1
3
4
5
6
7
16
15
17 18
21
19
20
2
8
9
10
11
(FRONT)
(BACK)
12
13
14
1Operation Panel 12 Tank Cover
2Air Outlet 13 Water Level Window
3Vertical Louver 14 Tank Knob
4Horizontal Louver 15 Mold Filter
5Main Unit 16 Back Panel (Pre-Filter)
6Handle (2 Locations) 17 Air Inlet
7Front Display 18 Temperature/Humidity Sensor
8Water Tank 19 Drainage Hole, Rubber Cap
9Drain Outlet 20 Caster (4 Locations)
10 Float 21 Power Cord, Plug
11 Tank Handle

EN-4
FRONT DISPLAY
PART NAMES
1
Humidity Monitor
Indicates the approximate humidity level in the
room.
Timer Monitor
Indicates setting time or remaining time of ON/
OFF timer.
HUMIDITY SELECT Monitor
Indicates setting humidity of HUMIDITY
SELECT mode.
2Plasmacluster Ion Indicator Light (Blue)
3OFF Timer Indicator Light
4ON Timer Indicator Light
5Tank FULL Indicator Light (Red)
Blinking when the Water Tank is Full.
6
DEFROST Indicator Light
Indicates the Main Unit operates the
DEFROST mode.
7
MOLD CONTROL Sign
Indicates the operation mode of the MOLD
CONTROL operation.
16
910
23457
11
8
12345
67
Humidity 20% to 90% is displayed.
20%
or less
90%
or more
Press the button with " " to start.
OPERATION PANEL
1Power ON/OFF Button 7H.SWING Button, Indicator Light
2MOLD CONTROL Button, Indicator Light 8ON/OFF TIMER Button
3LAUNDRY Button, Indicator Light 9INTERNAL DRY Indicator Light
4DEHUMIDIFY Button, Indicator Light 10 Child-Lock Indicator Light
5HUMIDITY SELECT Button 11 Light Sensor
6V.SWING Button, Indicator Light

EN-5
ENGLISH
OPERATION
FILTER INSTALLATION
PREPARATION
1. Remove the Back Panel.
Back Panel
2. Remove the plastic bag from the
Mold lter.
Mold Filter
3. Install the Mold lter in the correct.
Mold Filter
4. Install the Back Panel.
Click
AUTO :
The humidity and the fan speed are automatically
controlled by the "temperature and humidity
sensor".
SELECT :
You can select your favorite humidity. (See below)
START / STOP
DEHUMIDIFY OPERATION
♪♪~
START STOP
♪
♪
♪
♪♪
Temperature 4-26oC 26-38oC
Humidity 60% 55%
AUTO OFF Function
The operation will stop automatically after 12
hours in case the Main Unit has been forgotten
to be turned o.
When you want to run the Main Unit for more
than 12 hours continuously or drain water
continuously, turn o the Auto O function.
(Page 8)
The operation is not stopped while operating with
"Deodorization operation".
♪♪ ♪ ♪
♪♪
HUMIDITY SELECTION
When you press the DEFUMIDIFY button to set
SELECT mode, target humidity level can be
changed to cycle among 60%, 70%, 80%, 40% and
50%RH in sequence.
* HUMIDITY SELECT can be works only when in
SELECT mode.

EN-6
OPERATION
DRY(AUTO) :
When you want to dry with less power
consumption, the Main Unit will repeat the
Dehumidifying operation and the Air Flow mode
to dry the laundry.
DEODORIZE :
When you want to deodorize your laundry, the
Main Unit operates at "HIGH" fan speed.
Make sure the air blowing out from air outlet is
directed to your laundry.
You cannot select the Plasmacluster Ion "OFF".
LAUNDRY OPERATION
♪
♪
♪
♪♪
MOLD CONTROL OPERATION
【for about 80 minutes】
(MOLD CONTROL Sign : blinking with Purple)
※Operating time depends on the room environment,
usage conditions, and location of the Main Unit.
NOTE
• When the humidity becomes low, the main unit
operates with “Low” air ow.
(
MOLD CONTROL Sign :
lighting in Blue)
If the humidity becomes high again, it will switch to
the above operation under the condition of “in a high
humidity”.
In a low humidity
In a high humidity
It operates in “HIGH” mode of dehumidication
until the humidity of the room decreases to
the level which the mold less likely appears.
Once the humidity in room becomes low, the
model switches the operation with maximum
airow.
This mode is used to suppress the mold through
strong air ow with Plasmacluster Ion.
When turned ON, it rstly starts ventilation for 10
minutes with maximum air ow, and then repeats
following operation.
(MOLD CONTROL Sign shows actual operating
mode. Purple: high air volume, Blue: low air
volume.)
It operates automatically the Plasmacluster Ion
“ON”.
INTERNAL DRY OPERATION
When you set the Internal Dry operation, the Main
Unit automatically operate the Air Flow mode for
approximate 90 minutes after stopping.
more 3 sec.
(with the Main Unit ON)

EN-7
ENGLISH
TIMER OPERATION
The Main Unit automatically starts once the
selected time passes.
The Main Unit automatically stops once the
selected time comes.
ON TIMER
OFF TIMER
(with the Main Unit OFF)
(with the Main Unit ON)
Front Display
Front Display
CHILD LOCK
SWING LOUVER
The operation of the operation panel will be locked.
more 3 sec. more 3 sec.
VERTICAL SWING
DRY, DEODORIZE DEHUMIDIFY
WIDE
UP
DOWN
♪
♪
♪
♪♪
♪
♪
♪
♪♪
DRY, DEODORIZE DEHUMIDIFY
ROUND
WIDE
SPOT
♪♪~
ON CANCELLATION
CANCEL(OFF)
CANCEL(OFF)
……
♪ ♪ ♪ ♪ ♪♪
1hour 2hour 3hour 12hour Cancel
……
♪ ♪ ♪ ♪ ♪♪
1hour 2hour 3hour 12hour Cancel
HORIZONTAL SWING
After 8 seconds, the beep sounds.
After 8 seconds, the beep sounds.

EN-8
ENGLISH
START/STOP
OPERATION
HOW TO CHANGE VARIOUS SETTING
Type of setting
Function Setting
Auto Restart
If the Main Unit is
unplugged or if there is a
power failure, the Main Unit
will resume operation with
the previous settings after
power is restored.
Cancellation
ON (default)
Sound Indicator Setting
You can turn o the
beeping sound when the
Main Unit stops operating
as follows.When the Main
Unit stops operating as the
following situation, you can
turn o the beeping sound.
Cancellation
ON(default)
Light Control
You can select the
brightness of the Front
Display.
Turn o
When set to “Turn o”, the
“Darker” light illuminates for 8
seconds after operation starts
and then the light turns o.
The FULL Light ashes darker
only when the Water Tank is
full.
Darker
Auto (default)
Light automatically switches
based on room brightness.
Room
Front Display
bright brighter
dark darker
* When "SLEEP" mode operate;
Room is bright : light is darker
Room is dark : light is OFF
PLASMACLUSTER ION
ON/OFF
OFF
ON (default)
Auto O
The operation will stop
automatically after 12 hours
in case the Main Unit has
been forgotten to be turned
o.
Cancellation
ON (default)
Adjusting Sensor
Sensitivity
Light Sensor
Low
Standard (default)
High
You can change the functions in the table "Type of setting".
1. Turn o the Main Unit power.
2.
more 3 sec.
♪
3. Select "Function number".
Forward Reverse
or
・・・・
Set ♪
4. Select "Setting number".
Forward Reverse
or
Set ♪
5. Press Power ON/OFF Button to
nish the setting mode.
♪~
Turn o
♪
♪
♪
♪

EN-9
ENGLISH
HOW TO DRAIN
1. Remove the Plug.
2. Remove the Water Tank and the
Rubber Cap.
Rubber Cap
3. Set the hose in the Back Hole.
Back Hole
Commercial hose :
inner diameter 15mm
(outer diameter up to
21mm)
4. Insert the hose rmly to bottom in the
Drain Hole.
HoseDrain OutletDrain Stopper
Back Hole
5. Install the Water Tank.
When you want to drain continuous
How to pipe the hose
♪♪・・・
When the Water Tank
is Full, the TANK FULL
Indicator Light is blinking.
Always have the tip slanted.
Do not bend.
Under cold weather,
do not put the hose
into the water.
1. Remove the Water Tank.
Tank knob
Water Tank
2. Dispose the water of the Water Tank.
▶
Drain Outlet
3. Install the Water Tank.
Drain Outlet
NOTE
• Clean the Water Tank about once a week. If you
do not clean the Water Tank, it can cause mold,
bacteria, and bad odors.

EN-10
ENGLISH
Water Tank (About once a week) BACK PANEL / SENSOR
(About once every 2 weeks)
MAIN UNIT (About once a month)
CARE AND MAINTENANCE
Remove the dust
gently with a
cleaning tool such as
a vacuum cleaner.
Wipe with a dry, soft cloth.
The lter is fragile, so be
careful not to give too much
pressure.
Remove the dust on
the Mold Filter.
CAUTION
Do not wash the lter. Do not expose to sunlight.
(Otherwise the lter may lose e cacy.)
MOLD FILTER
(About once a month)
LIFE OF FILTERS
Filter life varies depending on the room environment,
usage conditions, and location of the Main Unit.
We recommend replacing the lter more frequently
if the Main Unit is used in conditions signi cantly
more severe than a normal household.
•Mold Filter About 1 years after opening
Replacement Filter Model
Consult your dealer when purchasing
a replacement lter.
Mold Filter(1 unit)
FZ-J27KFE
Disposing of lter
Dispose of used lter according to
local laws and regulations.
Mold Filter material:
• Polypropylene • Polyethylene
FILTER REPLACEMENT
Do not wash with water.
1. Remove the Tank Cover, and dispose
of the water.
▶
Tank Cover
2. Wash the inside of the Water Tank.
NOTE
• If the dirt is heavy, please dissolve neutral
detergent in lukewarm water and wash.
3. Dry the tank with a soft cloth.
Check the oat.
4. Install the Tank Cover.
NOTE How to clean and remove a heavy dirt.
Back Panel
1.Add a small amount of neutral
detergent to water and soak for
about 10 minutes.
CAUTION
Do not give excessive pressure to
the back panel when scrubbing it.
2.Rinse o the neutral detergent with
clean water.
3.Completely dry the lter in
a well-ventilated area.

EN-11
ENGLISH
When storing for a long
period (not in use)
1. Operate the INTERNAL DRY
OPERATION.
①Start operation.
②Select the Internal
Dry Operation.
③Stop Operation.
*Start the Internal Dry Operation, and
stop automatically after approximate 90
minutes.
2. Dispose tank water and care the Main
Unit.
3. Store in a dry place away from direct
sunlight.
Plastic bag
♪
more 3 sec.
♪~
ERROR DISPLAY
TROUBLESHOOTING
Before contact for service, check the following points to
make sure that the problem is not a Main Unit malfunction.
If error occurs repeatedly, contact the Sharp authorized
Service Center.
The room becomes hot.
• The Main Unit generates heat during LAUNDRY DRY
operation and DEHUMIDIFY operation and the room
temperature will rise. Warm air will be come out from
the air outlet, but this is normal and does not indicate a
problem with the Main Unit.
The Main Unit does not dehumidify.
• The dehumidication level varies with the size, structure,
temperature and humidity level of the room. When room
temperature or humidity level is low, the dehumidication
level will be low in general.
• Check whether the Back Panel is clean.
• Check whether the air outlet or air inlet is not blocked.
Sounds
• The Main Unit may make clicking or ticking sounds
when it is generating ions.
• The Main Unit may seem rather loud for the rst 2 to
3 minutes when the Main Unit is turned on. This is the
sound of the compressor starting-up and is perfectly
normal.
• A soft, swishing noise can be heard immediately after
the Main Unit is turned on or o, and also during
operation. This is the sound of the refrigerant owing
inside the Main Unit.
The sound is too loud.
• The Main Unit will sound loudly for the rst few seconds
upon power-on when the room temperature is low.
• Check whether the Main Unit is placed on a stable and
level oor.
• Check whether the Back Panel is not clogged.
There is a discrepancy between the
Main Unit’s Humidity Monitor and
another hygrometer in the room.
• There is a dierence in the humidity level within the
same room.
• The sensor have dierent measurement parameters.
The water leaks.
• Check whether the main unit is placed horizontally.
• When draining continuous, check whether the hose is
inserted all the way seated.
• If the Water Tank is full, drain the water.
• If the Water Tank is not properly placed,
place the Water Tank correctly.
• The Main Unit is operating with the
DEFROST mode.
• Laundry DRY (Auto) operation has
completed, and the operation has
stopped.
• The operation has stopped with the
Auto O function.
• Unplug the Main Unit, wait one
minute, and then plug the Main Unit
in again.

EN-12
SPECIFICATIONS
Model DW-P22A
Power Supply 220V-240V/50Hz
Dehumidifying Capacity ※130°C/80%RH 22 L/day
26.7°C/60%RH 13 L/day
Power Consumption ※230°C/80%RH 290 W
26.7°C/60%RH 230 W
Standby Power ※30.7 W
Recommended Room Size for Dehumidifying ※427-54 m2
Recommended Room Size for High density Plasmacluster ion ※533 m2
Water Tank Capacity Approx. 4.6 L
Cord Length Approx. 2 m
Dimensions 359 mm(W) × 248 mm(D) × 665 mm(H)
Weight 16.0 kg
※1 The amount of humidity that a dehumidier removes from the air in a day when room temperature and relative humidity are
kept at 30°C/80%RH and 26.7°C/60%RH respectively.
※2 The consumption value when fan speed reaches the highest.
※3 When the Main Unit’s power plug is inserted in a wall outlet it consumes the standby power in order to operate electrical
circuits.
※4 Based on standards of JEMA.
※5 Recommended Room Size for High density Plasmacluster ion in which approximately 7000 ions per cubic centimeter can
be measured in the center of the room when the Main Unit is placed next to a wall, is running at LAUNDRY Operation
“DEODORIZE” mode settings, and is at a height of approximately 1.2 meters from the oor.

EN-13
ENGLISH

感謝購買 SHARP 抽濕機。
在使用本產品之前,請先詳細閱讀本使用說明書。
在閱讀後,請妥善保存本使用說明書,以便於日後有需要時查閱。
目錄
安全注意事項....................................................................................................
1
部件名稱 ...........................................................................................................
3
使用前...............................................................................................................
5
操作方法
運行開始 /停止.............................................................................................
5
除濕模式.......................................................................................................
5
濕度設定.......................................................................................................
5
乾衣除濕模式................................................................................................
6
內部除濕模式................................................................................................
6
抑菌防霉模式................................................................................................
6
搖擺送風.......................................................................................................
7
定時開 /關機 ................................................................................................
7
兒童安全鎖 ...................................................................................................
7
各種功能的變更設定.....................................................................................
8
排水方法 ...........................................................................................................
9
保養與清潔........................................................................................................
10
故障時的檢查事項.............................................................................................
11
規格 ..................................................................................................................
12
除濕
根據高濕度的溫暖空氣接觸冰冷物品時會產生水滴的原理,
將潮濕空氣吸入蒸發器中,去除水分。
在下列情況中,壓縮機將會停止,且不會除濕。
• 室溫低於 4°C 或高於 38°C。
• 在下列情況中,主機會再次運行 3 分鐘,以保護主機。
*插上電源插頭後立即運行。
*在乾衣除濕/除濕模式停止後立即進行。
• 當室溫低於 18°C 時,壓縮機將會停止,且每 45 分鐘,會運行
約12 分鐘「強」風量模式,以避免主機內部受到結霜的傷害
(除霜模式/除霜指示燈亮起)。
①
④
②
③
乾空氣
潮濕空氣
儲水箱
蒸發器
冷凝器
中文

ZH-1
中文
此款高效能的抽濕機配備高濃度 Plasmacluster ions,可淨化
空氣、快速乾燥以及為室內晾乾之衣物除臭。
抑菌防霉模式
在房間釋放Plasmacluster及除濕空氣,以防止霉菌擴散。
1 2 3
強風量送風 除濕 空氣淨化
濕度低於 50%RH,
啟動空氣淨化功能
濕度高於 60%RH,
啟動除濕功能
乾衣除濕
透過廣角導風板可以上下左右擺動,
促使大面積的空氣流動,迅速乾燥衣物。
霉菌過濾網
透過霉菌過濾網和前置過濾網收集空氣中的霉菌
4.6L 大容量儲水箱
可持續除濕。(超過大約6小時。)
*請參考封面的注釋。
安全注意事項
使用電器時,務必遵守以下各方面的基本安全
預防措施,包括:
警告 -請務必遵守下列事項,以降低觸電、
火災或受傷風險:
•在使用主機之前,請先閱讀所有注意事項。
•僅能使用220-240V插座。
• 除在監護人或負責其安全人士的適當監督或
指導下使用外,主機不適合身體機能或心智
能力退化者,或缺乏操作經驗和知識的人士
(包括兒童)使用。應適當監管兒童,確保
不會玩弄此機器。
• 如果電源線損壞時,必須由製造商或其代
理、SHARP 公司特約服務中心,或具有同
等資格的人員負責更換,以免發生危險。
• 在進行排水、維護、拆卸、安裝及更換過濾
網之前,以及長時間不使用時,請務必拔掉
電源插頭,以避免可能會因為短路而導致觸
電或引起火災。
•如果電源線或插頭已損壞,或牆上的電源插
座已鬆脫,請勿使用主機。
•定期清除電源插頭上的灰塵。
•請勿將手指或異物插入吸氣口或吹出口。
•在拔掉電源插頭時,請務必緊握插頭拔出,
絕不可拉扯電線,以避免可能會因短路而導
致觸電或引起火災。
•在移動主機時,請小心腳輪,勿損壞電源
線,以避免可能會導致觸電、發熱或火災。
•請小心不要損壞電源線,以免導致觸電、過
熱或發生火災。

ZH-2
安全注意事項
•請勿以潮濕的手拔除電源插頭。
•請勿在氣體設備或壁爐附近使用主機。
•此款抽濕機僅可由SHARP公司授權之服務
中心進行維修。若主機出現任何問題、需要
調校或修理,請聯絡客戶服務中心。
•請勿在噴灑噴霧殺蟲劑後使用主機。請勿在
有油性殘餘物、焚香、點燃香煙的火花、空
氣中有化學煙霧的空間內使用主機。
請勿在潮濕的環境(例如浴室)使用主機。
•請注意在清潔主機時,具強力腐蝕性的清潔
劑可能會損壞外殼。
•在搬運主機時,請先取出儲水箱,並握住主
機兩側的把手搬運。
•切勿飲用儲水箱內的水。
•切勿使主機接觸水源,以免可能會導致短路
或觸電。
•定期清潔儲水箱。在不使用主機時,請倒空
儲水箱中的水,若不倒空可能會發霉、滋生
細菌及產生惡臭,在少數情況下,此類細菌
可能會損害健康。
•如想要連續排水時,請先檢查彎曲軟管/排
水的高度,並將軟管設置在安全排放位置。
•在使用軟管時,請使軟管周圍的溫度保持在
冰點以上。內部的水可能會流出至室內及弄
濕家具,或導致觸電及火災。
注意-主機干擾收音機或電視接收時的相關
措施。
如果本抽濕機對收音機或電視接收造成干擾時,
請嘗試採取下列一項或多項措施修正干擾:
•調整或重新放置接收天線。
•增加主機與收音機或電視之間的距離。
•將主機與收音機或電視接收器連接至不同電
路的電源插座。
•若需要協助,請諮詢經銷商或合格的收音機
或電視技術人員。
操作注意事項
•請勿堵塞吸氣口或吹出口。
•請勿在熱源物體附近或在熱源物體上(例如
爐灶或暖爐,或可能會接觸到蒸汽的場所)
使用主機。
•主機僅能直立使用,切勿平放。
•在移動主機時,請緊握兩側的把手。切勿移
動正在運行中的主機。
•在易損、不平坦的地面及較厚的地毯上,
應將主機抬起移動。
•在推動腳輪,移動設備時,請以水平方向慢
慢移動。
•在移動之前,應先關閉主機及拆除儲水箱,
請小心,不要夾傷手指。
•在正確安裝儲水箱之前,切勿運行主機。
•僅可使用柔軟的布清潔主機外部,切勿使用
揮發性液體或清潔劑。
苯塗料稀釋劑或拋光粉可能會損壞主機表面
或使表面裂開,此外,亦可能會導致感測器
發生故障。
•請使主機保持遠離水源。
•請務必徹底抹掉儲水箱外面多餘的水。
•請勿握住把手搖晃儲水箱。
•在拆卸或清潔儲水箱時,應避免水溢出。
•請勿拆除浮板。
•在保養儲水箱和儲水箱蓋時,請勿使用清潔
劑,以免導致變形、變色、龜裂(漏水)。
•在保養時,請勿用力擦洗背板。
安裝指南
•請勿將主機(感測器)安裝在直接面對出風口
的位置,以免可能會影響主機正常工作。
•請避免在可能會與傢俱、織物或其他物品接
觸的位置使用主機,以免可能無法確保吸氣
口或吹出口暢通。
•請勿在溫差極大,或會導致主機直接暴露
於冷凝環境的位置使用。主機僅適合在4-
38°C之間的室溫下使用。
•安裝時必須穩固,且通風良好。將主機放置
於鋪設厚地毯的位置,可能會導致主機微微
震動。請將主機置於平整的表面,以避免儲
水箱漏水。
•請避免在會產生油脂或油煙的場所使用主
機,以免可能會導致主機表面裂開以及感測
器發生故障。

ENGLISH
ZH-3
中文
部件名稱
1
3
4
5
6
7
16
15
17 18
21
19
20
1操作面板 12 儲水箱蓋
2吹出口 13 水位窗
3上下導風板 14 儲水箱拉槽
4左右導風板 15 霉菌過濾網
5主機 16 背板(前置過濾網)
6把手(
左右兩處
)17 吸氣口
7顯示面板 18 溫度/濕度感測器
8儲水箱 19 排水孔、塞頭
9排水口 20 腳輪(4個)
10 浮板 21 電源線、電源插頭
11 儲水箱手柄
2
8
9
10
11
主機
(正面)
(背面)
12
13
14

ZH-4
顯示面板
部件名稱
1電源(開/關)按鍵 7左右擺風按鍵、指示燈
2抑菌防霉按鍵、指示燈 8定時(開/關)按鍵
3乾衣除濕按鍵、指示燈 9內部除濕指示燈
4除濕模式按鍵、指示燈 10 兒童安全鎖指示燈
5濕度設定按鍵 11 亮度感測器
6上下擺風按鍵、指示燈
1
濕度偵測指示燈
說明房間內之濕度數值的近似值。
定時(開/關)指示燈
顯示定時(開/關)的設定時間或剩餘時間。
濕度設定
顯示濕度設定模式所設置的濕度。
2Plasmacluster ion 指示燈(藍色)
3定時關機指示燈
4定時開機指示燈
5滿水指示燈(紅色)
當儲水箱滿水時會閃爍。
6除霜指示燈
顯示主機在除霜模式下運行。
7抑菌防霉指示燈
顯示主機在抑菌防霉模式下運行。
16
910
23457
11
8
12345
67
按一下「 」的按鍵,以開始。
顯示20%至90%的濕度。
20%
以下
90%
以上
操作面板
Table of contents
Other Sharp Dehumidifier manuals

Sharp
Sharp DW-209EX User manual

Sharp
Sharp UD-P16E-W User manual

Sharp
Sharp DW-R268A User manual

Sharp
Sharp DW-RN23A-W User manual

Sharp
Sharp Plasmacluster DW-J27FV User manual

Sharp
Sharp DW-E16FA User manual

Sharp
Sharp DW-J27A User manual

Sharp
Sharp DW-E16FA-W User manual

Sharp
Sharp DW-D20A User manual

Sharp
Sharp DW-71-H User manual
Popular Dehumidifier manuals by other brands

Drieaz
Drieaz F533-115V Operation and maintenance guide

Air Naturel
Air Naturel Dehumax user manual

Pro Breeze
Pro Breeze PB-02 instruction manual

Universal Blue
Universal Blue UCDH8002-20 instruction manual

Drieaz
Drieaz LGR1800 owner's manual

System air
System air Fantech GDC Series Installation, operation and maintenance manual