Sharp DW-R268A User manual


DW-R249A_HK
TINSJA103FBRZ4KK
SHARP CORPORATION

CONTENTS
ENGLISH
ENGLISH
Thank you very much for purchasing this SHARP dehumidifier.
Please read this manual carefully to ensure safe, effective use of your dehumidifier.
Please read carefully through ÒPrecautionsÓ before commencing to use this product.
Please keep this manual within easy reach so that you can refer to it at any time you need.
Precautions........................................
Proper Uses...........................................
Part Names and Functions...................
Preparations Before Using...................
Operation Procedure ............................
Dehumidifying auto operation
Continuous dehumidify operation
Dry clothes operation
E-2
E-5
E-6
E-8
E-9
Changing the air flow direction..........
How to Operate the Timer ..................
Emptying the Water Tank ..................
Continuous Drainage..........................
Maintenance ........................................
Things to remember............................
Defrosting ............................................
Before calling for Service...................
E-12
E-13
E-14
E-15
E-16
E-17
E-17
E-18

E-2
Failure to follow this instruction may
result in death or serious injury.
Warning
Cautions
Failure to follow this instruction may
result in injury or damage to property.
Precautions
Precautions
Warning
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Musts
Musts
DW-R249A_eng
Various symbols are used throughout this manual
and on the product to alert you to points relating
to safe use of this product.
These symbols are classified according to the
seriousness of the risk involved if they are
ignored and explained below.
Please read this section carefully and follow the
instructions.
Do not operate the unit at voltages
other than the rated voltage of 220V.
Using this product at any other voltage may
result in electric shock or fire.
Make sure that the power plug is not
covered with dust before inserting the
plug into the power socket.
Do not place the unit near any heat
sources.
Otherwise resin
material in the
product may melt
and catch fire.
Do not modify the unit. This unit should
not be disassembled or repaired by
persons other than a qualified
technician.
If repair is required, please consult
the SHARP Service Center.
Otherwise fire, electric shock or injury may
result.
Musts
If the supply cord is damaged, it must
be replaced by the manufacturer, its
service agent or similarly qualified
persons in order to avoid a hazard.
Prohibited
When any abnormality (e.g. a burning
smell) is noticed, turn the power off,
unplug the unit and consult the SHARP
Service Center.
Do not place any spray cans or other
hazardous materials near the unit.
Also make sure not to place any ignition
hazard materials (gasoline, thinner) near the
unit. Otherwise these materials could ignite
or explode, resulting in a fire.
Do not insert your finger or foreign
objects (pins, wire, sticks) into the air
outlet or air intake.
Do not try to take out the plug by pulling
the power cord in order to stop operation.
Otherwise electric shock or fire may result.
Do not modify or cause damage to
the power cord in any way.
Do not connect this product using
joined electric cords or extension
cords, or sharing a power socket with
other electrical appliances.
Otherwise there is a
risk of electric shock,
heat or fire.
Handle the power cord with care.
Avoid damaging it, bending it
sharply, pulling, twisting, bundling
or heating it, placing heavy
objects on it or getting it caught
between objects. Otherwise the
power cord may be damaged,
resulting in electric shock or fire.
Otherwise fire, electric
shock or injury may
result.
If the unit continues to
be operated despite
signs of abnormality,
a breakdown, electric
shock or fire may
result.
Regularly wipe off the power
plug with a dry cloth.
Dust on the plug will prevent
a proper connection, which
may result in electric shock
and fire.
A fan is rotating at
high speed inside
the unit. Do not put
your hands inside
the unit to avoid
injury, electric
shock and damage
to the unit.

E-3
Meaning of the Symbols
Actions that must be taken.
Musts
Actions that should be strictly avoided.
Prohibited
Cautions
Prohibited Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Do not move the unit on its casters on
an uneven surface.
Lift the unit up to move it on an uneven surface
to prevent damage to the casters or the floor.
This also applies to moving the unit on a thick-
piled carpet. The casters could leave marks on
floors and carpets.
Do not knock over the unit or drop it. Do
not store or move the unit on its side.
This could damage the unit or result in water
leakage and short circuit.
This product is for indoor use only. Do
not install in locations exposed to direct
sunlight or without shelter.
Otherwise this may lead to overheating, electric
shock, short circuits or fire.
Do not wash the unit
directly with water.
Otherwise electric shock may result.
Do not install the unit in
locations exposed to
splashing water.
Otherwise electric shock,
short circuits or fire may result.
Do not use the unit in an elevated
location, like on top of a table.
Otherwise the unit could fall down, resulting in
personal injury or damage to the unit.
Do not obstruct the air outlet or air intake
with clothing or any other materials.
Otherwise the air flow will be obstructed, resulting
in overheating, ignition or
malfunction.
When the unit is not in
use, the WIDE SWING
protects it from entry of
dust and dirt.
Take care to hold the plug firmly when
unplugging the unit.
Pulling the cord may cause the wire inside to
break, resulting in overheating.
Do not place a combustion
device (e.g. stove) near the
air outlet of the dehumidifier.
Otherwise incomplete combustion may result.
Do not stand on the unit or
lean against it.
Otherwise the unit could move or
fall over, resulting in personal injury.
Do not use the
drained water as
drinking water for
humans or pets.
The drained water may be
harmful to health.
Do not use this unit for storage of any
items that require strict
temperature control,
such as art works or
academic materials.
Otherwise the quality
of these items may actually deteriorate.
Do not install this unit in locations where
there is any risk of exposure to leaking oil
or combustible gas.
Leaking oil or gas near the the unit may cause fire.
Do not place any
vessels containing
water, e.g. a vase,
on the unit.
Do not operate the unit
in a closet or in a narrow,
confined space between
furniture.
Insufficient ventilation can result
in overheating or combustion.
Take care to read through the safety cautions before
commencing to use this product. Keep this manual within
easy reach so that you can refer to it at any time.
Water spilled on the unit
may impair electrical insula-
tion, resulting in electric
shock, short circuits or fire.
ENGLISH
Precautions
DW-R249A_eng

E-4
Cautions for use
Keep at least 2 m away
Do not bend
the drain hose.
Cautions
・・・
Precautions
・・・
Precautions
Keep
20cm min.
Keep
50cm min.
Keep
20cm min.
Lighting
Musts Musts
Musts
Musts
Musts
Musts
Musts
Musts
Musts
DW-R249A_eng
Before moving the unit make sure that
the power is turned off and that the
tank is emptied.
Otherwise spilled water may wet household appliances
resulting in electric shock, short circuits or fire.
Whenever the unit is to
be left unused for a
long period, make sure
to unplug the unit for
safety.
Otherwise, electric shock
or fire may result.
Do not operate this product with the power cord still wound onto the cord clamps.
Otherwise, overheating or fire may result.
Keep the unit at least 2 m away from a TV, radio or wave clock.
Otherwise the unit may cause radio interference.
Is the unit operating at a room temperature of more than 35¡C, with the unit's WIDE SWING louver blowing toward the
rear in DRY CLOTHES mode at "Low" air flow rate or in CONTINUOUS DEHUMIDIFY mode at "Low" air flow rate?
Is the air outlet or air intake covered with a cloth or the like?
Check whether the unit is operated in a location with inadequate ventilation such as a closet or a narrow space between furniture.
Check whether the unit is operated in an improper place under direct sunshine, near heating
sources or air outlet of hot wind emerging from air conditioners or oil fan heaters.
Check that the size of the room where you are operating the unit is not too small.
When the compressor for the cooling cycle becomes abnormally hot, operation is automatically
stopped for safety. If this happens, unplug the power cord from the wall outlet, eliminate the
problem, and restart operation after a waiting period of about 40 minutes. If the [ ] indicator
still remains on, consult the shop where you purchased the unit or your nearest SHARP
Service Center.
When [ ] lights on the LED display on the operation panel and operation stops,
the unit may be used under one of the following conditions and in one of the
following locations. This is normal and does not indicate a problem with the unit.
Operating the unit in DRY CLOTHES or CONTINUOUS DEHUMIDIFY mode for long
periods causes the room temperature to rise and the air to dry out. Do not operate
the unit for long periods in rooms where people are present.
When operating the unit for a prolonged
period in the same location, check for
dirt under and around the unit.
Move the unit occasionally and clean the
floor under it.
If the unit is continuously being used for a long
period of time, make sure to inspect it regularly.
Otherwise overheating or electrical short
circuits may result.
Make sure to operate this product
only on level, stable surfaces.
An uneven surface may cause stored water to spill
and to make household furniture or appliances wet,
or to cause electric shock, short circuits or fire.
When moving the unit, drain water first from
the tank. Move its caster
by grasping the carrying
handle firmly so that the
dehumidifier may not be
inclined.
Otherwise this can cause
injuries or damage to the floor.
Leave a clearance around the unit of at
least the size shown in the drawing below.
Insufficient ventilation can result in overheating
or combustion.
If a drain hose is used, take care that the
temperature around the hose does not fall
below 0¡C.
Otherwise, water in the hose may freeze causing
undrained water to leak from the unit and make
household furniture or appliances wet.
When water is to be drained
continuously, take care that
the hose is not bent and that
the hose outlet is positioned
below the unit.
Otherwise drained water may spill
and make household appliances or
furniture wet.

E-5
To ensure good operating efficiency, avoid
repeatedly opening doors and windows in the room
where the unit is operating.
Proper Uses
Dry bedding
It is efficient to dry the bedding etc.
Dry washing
Seen from the front of the unit, the air flow exits slightly
to the right. When drying clothes, use the WIDE SWING
louver to make sure the air flow is directed toward the
laundry and dries it quickly.
Living room or kitchen
Dehumidify while you rest.
Set timer before you leave. Come home and experience the
pleasant surroundings.
While you are away
In winter when the room temperature is low (below 10¡C), use the
dehumidifier in combination with a room heater to reduce the drying time.
Stand-type rack
for dring clothes
DRY CLOTHES
When you want to quickly dry clothes.
AUTO DEHUMIDITY
AUTO
MOLD ATTACK
Prevent condensation on ceilings, walls and windows.
AUTO PREVENT
CONDENSATION
CONTINUOUS
DEHUMIDIFY
To maintain room humidity at a comfortable level.
Preventing mold formation.
To reduce the humidity of rooms where no one is present.
Lowering room humidity
Drying washing
Effective uses
E-10
page
E-9
page
E-11
page
Plasmacluster ions (a large
quantity of plus and minus ions)
attach themselves to the
surface of floating mold spores.
The hydroxyl radical OH extracts
the hydrogen atom (H) from the
cell walls of the floating mold
spores, thus destroying the cell
walls.
Mold spores
with destroyed
cell walls
self-destroy.
The plasmacluster ions, composed of
plus ions (hydroger ions: H+) and
minus ions (oxygen ions: O2
-
), react
at the surface of floating mold spores
and change to highly active hydroxyl
radical OH.
Plasmacluster ions deactivate floating mold spores
・
Measuring method: In PLASMACLUSTER ION operation, the density of mold spores floating
in the air is measured by an air sampler.
Testing organization: Ishikawa Prefecture Preventive Medicine Organization
Disinfection method: Discharge of plasmacluster ions into the air.
Plasmacluster ions surround the mold spores floating in the room air and inactivate them.
This reduces the odor generated when mold propagates.
PLASMACLUSTER ION effect
Automatically maintain the room humidity in the range 55% to 60%.
For the rooms on the north side or store rooms where people are normally not present.
For drying carpet.
For drying the insides of cupboards and closets. (Open the closet door to dry out the closet)
*1
*1 They lose their ability to propagate.
Mold spores Mold sporesMold spores
Precautions / Proper Uses / PLASMACLUSTER ION effect
ENGLISH

DW-R249A_eng
Over-inclination
might cause
damage to the
floor and water
to leak.
Do not place
power supply
cord between
the caster.
Drain water from
the tank.
Lift the carrying
handle.
Incline the unit. Move
Do not take out the water tank immediately after operation has stopped to prevent water leakage.
Move the unit by lifting it up when the floor is easily damaged or at a rugged place. Do not use the
caster on a thick-piled carpet. This can cause damage to the surface of the carpet.
Incline the unit
at an angle of
30¡ to 40¡ degrees
by putting
your foot on the
back of the unit.
Caution
Front view
Rear view
Air Outlet
Continuous drainage hole
Power supply cord
Caster
Cord clamp
Band
Plug
Handle
PLASMACLUSTER
ION indicator
Air intake
Water tank
FULL TANK
Indicator
Tank handle
Tank lid
Float
Filter
Blinks (green) when
the tank is full.
Hanging power supply cord together.
Use to move the unit.
Part Names and Functions
E-6
WIDE SWING
Louver
E-14・E-16
page
E-16
page
E-12
page
E-4・E-16
page
E-16
page
E-15
page
1
2
34

DW-R249A_eng
OPERATION indicator
DRY CLOTHES button
PLASMACLUSTER ION indicator
TIMER SETTING button
TIMER OFF indicator
TIMER ON indicator
AUTO indicator
PREVENT CONDENSATION
indicator
MOLD ATTACK indicator
AUTO DEHUMIDIFY
(HUMIDITY/TIMER SETTING indicator)
Sets ON/OFF TIMER.
Turns the dehumidifier on/off.
Changes over between AUTO (DEHUMIDIFY) /
PREVENT CONDENSION / MOLD ATTACK.
Press to select CONTINUOUS DEHUMIDIFY
operation and the desired air flow rate.
Changes the air flow direction.
Turns PLASMACLUSTER ION operation on/off.
Starts drying clothes.
LED Display
HUMIDITY indicator
TIMER SETTING indicator
WIDE SWING button AUTO DEHUMIDIFY button
CONTINUOUS DEHUMIDIFY button
UP/REAR/WIDE Air Flow indicator
CONTINUOUS DEHUMIDIFY
air flow indicator
DRY CLOTHES air flow indicator
Control panel
Power consumption
corresponds to 80% of the
humidity value.
The dehumidification area is
based on Japanese Electrical
ManufacturersÕ Association
(JEMA) Standards.
*
The term Òstand-byÓ means
that the dehumidifier is kept
at ÒOFFÓ position even
though its plug has been
inserted into the power socket.
E-7
POWER ON/OFF button
Specifications
(For explanatory purposes, all of the LED indicators are shown.)
Elbow joint Printed matter
(1 unit)
Operation manual
Used for hose
connection for
continuous water
drainage.
(1)
Supplied
Accessories
PLASMACLUSTER ION button
E-13〜E-14
page
E-9〜E-11
page
page
E-12
page
E-10
page
E-11
page
E-8
page
E-9
page
The numbers inside refer to the page where a detailed
explanation of the item is given.
Rated voltage
Model
Water tank capacity
Length of power supply cord
Outside dimensions
Weight
L
m
mm
kg
50Hz
220V
DW-R268A
360
33
〜
67
Approx.6.7 (Automatic stop at 6.0)
(Wooden houses
〜
concrete houses)
16.0
380(W)
×
294(D)
×
597(H)
Available length approx. 1.8
Frequency
* Stand by mode
W
W
m2
Dehumidification area
1.0W and less than
Rated dehumidification capacity
Rated power consumption
L / Day
26.0
Part Names and Functions (Specifications / Supplied Accessories)
ENGLISH

DW-R249A_eng
Do not remove the blue part inside the float.
Digital display :
「 」
Lighting
AUTO OFF TIMER indicator : blinking
タイマー スイング
上 弱 自動
結露防止
入
湿度
時間後
切
強後
ドワイド
フルパワー
連続除湿 自動除湿
Before operating
There may occasionally be water in the water tank when
the unit is operated for the first time. This is the drain
water generated when the product was inspected at the
factory and does not indicate a problem with the unit.
Preparations Before Using
E-8
If the ÒFull Tank indicatorÓ blinks, empty the water tank and reinstall the tank
properly.
Insert the plug into the power socket.
TEMPERATURE indicator
Normally the room temperature
is not displayed, but when it
rises above 41¡C or drops below
0¡C, the display blinks as shown
at right, indicating that the
allowable operating temperature
range has been exceeded.
「」
Blinking
「」
Blinking
Room temperature more than 41¡C
Room temperature less than 0¡C
While in operation, the unit operates in PLASMACLUSTER ION
operation in all modes.
* PLASMACLUSTER ION operation alone is not possible.
To stop PLASMACLUSTER ION operation, press the PLASMACLUSTER
ION button. The PLASMACLUSTER (Clean) indicator will go off.
To resume operation, press the PLASMACLUSTER ION button again.
PLASMACLUSTER button
Pip
Blinking
AUTO OFF function
In the event that the user forgets to turn off the unit, the AUTO OFF function automatically turns it off 12 hours
after it has been turned on, regardless of the operating mode.
12 hours after the unit has been turned on, the following
notifications are issued and all operations stop.
A beep sounds for 1 second.
The OFF TIMER indicator blinks.
[ ] appears on the LED display.
Notifications after operation stop
To release operation stop
To resume operation, press the POWER ON/OFF button twice. After pressing once, the AUTO OFF
indicator goes off, and after pressing again, operation starts.
Press the POWER ON/OFF button.
A beep sounds, and the unit enters normal
operation standby mode.
Releasing AUTO OFF function to dehumidify for a long period
To dehumidify with continuous drainage, refer to .
Caution
HUMIDITY indicator
When ON of the POWER ON/OFF button
is pressed, the humidity is indicated.
After plugging the power plug into the wall outlet and pressing ON of the
POWER ON/OFF button, the humidity sensor activates for about 1 minute.
During this period, the HUMIDITY indicator will blink.
Displayed when the room
humidity exceeds 81%.
(The humidity in the indication example is 68%.)
Blinking
Blinking
Lighting
The displayed humidity is a
guideline value, and may differ
from the actual room humidity.
Displayed when the room
humidity is below 39%.
Lighting
Caution
When the OFF TIMER has been set, it has priority over the AUTO OFF TIMER.
The moment the OFF TIMER is released, the AUTO OFF TIMER is set automatically.
When operation starts, the 12-hour AUTO OFF TIMER is set automatically.
The AUTO OFF TIMER operates even when the TANK FULL indicator lights during operation and
the unit stops. After 12 hours, the TANK FULL indicator will go off and all operations stop.
E-15
page
Lighting

DW-R249A_eng
Stop
When operation stops, the WIDE SWING louver returns to "Close" position. Note that in stopped
condition, the humidity is not indicated.
* If the POWER ON/OFF button is pressed to restart the unit after a stop, the unit resumes
operation in the previous selected mode.
Press the POWER ON/OFF button again.
Press the POWER ON/OFF button.
Press the AUTO DEHUMIDIFY button and select operation mode.
The OPERATION indicator lights and AUTO DEHUMIDIFY operation starts.
Operation mode is switched in order.
With the start of operation, the WIDE SWING louver rotates
from "Close" to "Up" and stops in that position.
Set the direction of the WIDE SWING louver.
Choose the optimum setting.
(Indication example)
AUTO DEHUMIDIFY mode, slightly high humidity, WIDE SWING louver in air flow direction "Up".
AUTO
To prevent the formation of mold, use the unit in rooms where
mold tends to form such as rooms on the north side or store
rooms where people are normally not present.
When humidity drops to below 50%, the dehumidifying
operation stops and the unit changes to fan operation.
MOLD ATTACK
The unit stops dehumidifying and blows air only when
the humidity is about less than 60% at temperatures up
to 27¡C, and when the humidity is about less than 55%
at temperatures of 28¡C or higher.
(Right figure)
However, depending on the room size and construction,
the unit may not stop dehumidifying.
PREVENT
CONDENSATION
DEHUMIDIFY operation is continuously carried out by
controlling the volume of air flow: ÒMediumÓ at temperature
of about 15¡C or more and ÒHIGHÓ at about 15¡C or less.
Caution
Under the following conditions, PREVENT CONDENSATION operation
will stop and the unit will change to fan operation. (See figure at right.)
The room temperature is 35¡C or more and humidity is less than 40%.
The room temperature is above 28¡C and less than 35¡C, and
humidity is less than 30%.
WIDE SWING button
AUTO DEHUMIDIFY button
POWER ON/OFF button
Operation Procedure
AUTO DEHUMIDIFY operation
WIDE SWING louver
Pip
Pip
Pip
Lighting Lighting
E-9
25
3028 35
30
35
40
DEHUMIDIFY
operating range
55
27
Temperature ¡C
Humidity %
Temperature ¡C
Humidity %
28 29
60
65
DEHUMIDIFY AUTO
operating range
E-12
page
OPERATION
indicator
CLOSE
UP
1
2
3
Preparations Before Using / Operation Procedure
Lighting
3
Lighting
2 1
ENGLISH

DW-R249A_eng
When operation stops, the WIDE SWING louver returns to "Close" position. Note that in stopped
condition, the humidity is not indicated.
* If the POWER ON/OFF button is pressed to restart the unit after a stop, the unit resumes
operation in the previous selected mode.
Stop Press the POWER ON/OFF button again.
Press the POWER ON/OFF button.
Press the CONTINUOUS DEHUMIDIFY button.
The OPERATION indicator lights and AUTO DEHUMIDIFY operation starts.
The "Low" air flow indicator for CONTINUOUS DEHUMIDIFY lights, and the unit starts
CONTINUOUS DEHUMIDIFY operation at "Low" air flow.
With the start of operation, the WIDE SWING louver rotates from "Close" to "Up" and stops in that position.
Set the direction of the WIDE SWING louver.
Choose the optimum setting.
(Indication example)
CONTINUOUS DEHUMIDIFY mode, air flow rate "Low", slightly high humidity, WIDE SWING louver in air flow direction "Up".
Changing the air flow rate
Press the CONTINUOUS DEHUMIDIFY button again and select Air Flow mode. The CONTINUOUS
DEHUMIDIFY Air Flow indicator lights and the air flow rate changes in the sequence shown below.
WIDE SWING button
CONTINUOUS DEHUMIDIFY button
POWER ON/OFF button
OPERATION
indicator
Pip
Pip
Pip
E-10
CONTINUOUS DEHUMIDIFY operation
Lighting
Lighting
Caution
In the cases below, the unit stops dehumidifying and blows air only.
When the room humidity is below 40% at temperatures over 35¡C
When the room humidity is less than 30% at temperatures more than 28¡C but less than 35¡C
* At Full Power, the unit operates at a
dehumidifying rate equal to 26 liters/day.
*
This causes the room temperature to rise and the air to dry out. Do not operate the unit for long
periods in rooms where people are present.
E-12
page
E-9
page
1
2
3
3
Lighting Lighting
2 1

DW-R249A_eng
When operation stops, the WIDE SWING louver returns to "Close" position. Note that in stopped
condition, the humidity is not indicated.
* If the POWER ON/OFF button is pressed to restart the unit after a stop, the unit resumes
operation in the previous selected mode.
Stop Press the POWER ON/OFF button again.
Press the POWER ON/OFF button.
Press the DRY CLOTHES button.
The OPERATION indicator lights and AUTO DEHUMIDIFY operation starts.
The "Low" indicator for DRY CLOTHES mode lights, and the unit starts DRY CLOTHES operation at "Low" air flow.
With the start of operation, the WIDE SWING louver rotates from "Close" to "Up" and stops in that position.
(Indication example)
DRY CLOTHES mode, slightly high humidity, WIDE SWING louver in air flow direction "Up"
WIDE SWING button DRY CLOTHES button POWER ON/OFF button
Set the direction of the WIDE SWING louver.
Choose the optimum setting.
Changing the air flow rate
Press the DRY CLOTHES button again and select Air Flow mode.
The DRY CLOTHES Air Flow indicator lights and the air flow rate
changes in the sequence shown below.
Combining this with PLASMA CLUSTER ION (Clean) mode will deactivate the mold spores floating in
the air (see for CLUSTER ION effect) and help to make your clothes even cleaner.
E-11
・・・
Operation Procedure
DRY CLOTHES operation
Lighting Lighting Lighting
Lighting
Caution
In the cases below, the unit stops dehumidifying and blows air only.
Caution
At "High" air flow rate, your clothes will dry faster, but the unit will generate more noise.
When the room humidity is below 40% at temperatures over 35¡C
When the room humidity is less than 30% at temperatures more than 28¡C but less than 35¡C
E-12
page
E-5
page
E-9
page
OPERATION
indicator
Pip
Pip
2
Pip
1
2
3
Operation Procedure
13
ENGLISH

弱 弱 自動
結露防止 カビアタック
強 強
フルパワー
衣類乾燥 連続除湿 自動除湿 入/切
運転
DW-R249A_eng
E-12
The WIDE SWING button allows you to select "Up", "Rear" or "Wide" for the air flow direction, or
stopping (Off) it at a desired angle.
Changing the air flow direction
By repeatedly pressing the WIDE SWING button, the position of the WIDE SWING louver can be changed in
the sequence shown below. To stop the WIDE SWING louver at a desired angle, press the button again (Off)
when the louver has reached the desired angle.
Press the WIDE SWING button during operation.
Pip
(Indication example)
AUTO DEHUMIDIFY
Operation in Wide Air Flow position
UP REAR WIDE
When operation stops, the WIDE SWING louver returns to "Close" position. To restart operation,
press the WIDE SWING button again and select the air flow direction.
Do not expose the WIDE SWING louver to impact or rotate it by force. Otherwise the louver may
be damaged.
After a change in air flow direction, the WIDE SWING louver is determining its position, so it may
take a few seconds until it starts moving.
Any object touching the WIDE SWING louver may cause the air flow direction to change. In this
case, set the air flow direction again with the WIDE SWING button.
The sound produced by the air flow changes with the air flow direction.
Caution
(OFF)
WIDE SWING louver
Lighting
WIDE SWING button

DW-R249A_eng
How to Operate the Timer
To set on timer
E-13
It can be set only when the unit is shut down.
ススイング
上後
ワイド
TIMER ON
indicator TIMER SETTING
indicator
TIMER SETTING
button
Pip
Lighting
To release timer operation, either press the TIMER button until the ON TIMER and TIMER SETTING indicators
go off or press the POWER ON/OFF button.
Caution
When the TANK FULL indicator blinks, empty the drain tank.
The operating mode can be changed even after ON TIMER operation has been selected.
To change the mode, press the respective operation button.
Example
If you set ON TIMER operation as Òafter 5 hoursÓ
Press the TIMER button.
The ON TIMER indicator, [ ] on the LED display and the
TIMER SETTING indicator light. At the same time, the
indicator for the previously selected mode lights.
When the POWER ON/OFF button is pressed after the
power plug has been plugged in, or when the POWER ON /
OFF button is pressed after a power outage, the unit is
preset to start operation in AUTO DEHUMIDIFY mode.
When the TIMER button is kept pressed, the indication on the
LED display changes automatically. While pressing the TIMER
button, the timer setting time changes as shown below in
1-hour increments. Select the setting time.
No indication
(set release)
Select the desired operating mode by pressing the AUTO DEHUMIDIFY button, CONTINUOUS
DEHUMIDIFY button or DRY CLOTHES button.
Select the desired operating mode.
When AUTO DEHUMIDIFY is selected, the DEHUMIDIFY mode can be changed by pressing the AUTO DEHUMIDIFY button.
When CONTINUOUS DEHUMIDIFY or DRY CLOTHES is selected, the air flow mode can be
selected with the respective selector button.
Pressing the WIDE SWING button lets you select the air flow direction from the WIDE SWING louver.
Pressing the PLASMACLUSTER button turns PLASMACLUSTER ION operation on and off.
The following settings can be changed as desired.
Canceling ON TIMER operation
(
(
Lighting
E-9
page
E-10〜E-11
page
E-8
page
E-12
page
Confirm that the OPERATION indicator has gone out and operation has stopped.
The timer indication changes every hour from 5
→
4
→
3
→
2
→
1, and after 5 hours operation starts.
1
2
1
Changing the air flow direction / How to Operate the Timer
ENGLISH

DW-R249A_eng
上上
ワイド
To release the OFF TIMER, either press the TIMER button until the LED
display indicates the room humidity, say [ ], or press the POWER ON/OFF
button to stop operation.
Indications change simultaneously as follows: the OFF TIMER indicator lights, the
LED display changes to [ ], the HUMIDITY indicator goes off, and the TIMER
SETTING indicator lights. The OFF TIMER setting time is indicated as [Off after 1 hour].
To cancel Off Timer
TIMER SETTING button
TIMER OFF indicator
Pip
Lighting
Lighting
Blinking
Before moving the unit, make sure to turn it off and
drain the water from the tank.
Otherwise water may spill out onto the floor.
Do not touch anything inside the unit after
the water tank is removed.
Otherwise when the tank is full, the automatic stop function may not work properly.
Clean the inside of the water tank periodically
(about once a week).
The unit may be soiled if it is not cleaned for a long time.
At low temperatures, water may freeze in the unitÕs
cooling system instead of collecting in the water tank.
Note that this is not a sign of failure.
Caution
When taking out the water tank, the front full
tank green lamp will blink up and the unit stops
its operation.
Remove the water tank.
If the water tank fills to a level of approx. 6.0 liters, the operation stops automatically. Then an electronic beep sound will be emitted
for 8 seconds, and the ÒfullÓ indicator light will blink showing that the water tank is full. Empty the tank as shown below.
Pull out the tank by pushing up the tank handgrip a little and take the tank out
carefully by holding it with both hands. The tank weighs about 7.0 kg when it is
filled up to the limit. Be careful to avoid getting injured when taking it out.
Empty the water tank.
Reinstall the water tank in the unit.
(1) Make certain that the tank lid is installed securely on the exterior of the tank, and that the handle is
stowed in its stowage position.
(2) Push the tank into the unit until it comes into firm contact with the back of the unit.
Tank handle Tank lid
Water tank
Float
The drainage tank can be carried by holding the tank handle.
Empty the water tank, clean the tank and wipe off excess water outside the tank.
If water remains on the float, the automatic stop function of the dehumidifier
will not work properly. So make sure to wipe away the water from the float.
Emptying the Water Tank
・・・
How to Operate the Timer
Confirm that the OPERATION indicator is on and the unit is in operation.
When the OFF TIMER works (operation stops), a beep sounds for about 1 second.
You can change the time to stop operation after having set the OFF TIMER. Press the TIMER button again.
Press TIMER SETTING button
Example
If you set OFF TIMER operation as Òafter 5 hoursÓ
The timer indication changes every hour from 5
→
4
→
3
→
2
→
1,
and after 5 hours operation stops.
Room humidity
(set release)
To set off timer it can be set when the unit is in operation
Caution
E-14
Pull here to
remove tank
Indicating set-time of OFF TIMER as ÒOFF after 1 hourÓ.
Select set-time of TIMER since the TIMER shifts sequentially in order as follows. (one-hour interval)
Inside of the float a blue part is installed. Do not take off the
part, it is necessary for function of operating the dehumidifier.
The indication automatically shifts by continuously pressing TIMER SETTING button.
1
2
3
1
1

DW-R249A_eng
This dehumidifier is for home use. If you use it with continuous drainage, make sure to check the unit at least once every 2 weeks for
a dirty filter or clogged drain hose.
If you are using a drain hose, make sure that the temperature around the hose does not drop below 0¡C. Water in the hose might
freeze causing water to spill and wet the floor and the unit.
Cover the end of the hose with netting to prevent insects from entering.
The AUTO OFF function also works during CONTINUOUS DRAINAGE. 12 hours after the start of operation, the unit will automatically
stop. The AUTO OFF function can be canceled as described below.
Cautions when using the unit with continuous drainage
Drain hose hole
CONTINUOUS DRAINAGE is possible, if there is a place to drain water nearby. Make sure to stop
operation, disconnect the power plug from the wall outlet and carry out the following procedure.
Open a drain hose hole.
Canceling the AUTO OFF function
Remove the water tank. Using a screwdriver, punch a hole at the drain hose hole
located at the back of the unit. Smoothen the edge of the hole with a file etc.
Before using CONTINUOUS DRAINAGE
Insert the elbow joint into the drainage outlet of the unit.
Remove the drainage tank. Pull down the drain stopper located at the upper right inside the casing.
Put your finger behind the rubber packing on the drain stopper. Then pull the rubber packing off toward
the front and remove the drain seat at the same time.
* These are important parts you will need when not using CONTINUOUS DRAINAGE. Keep the rubber packing and drain seat in a safe place.
Attach the elbow joint to the other end of the hose inserted into the continuous drainage hole.
Insert the elbow joint into the drainage outlet of the unit all the way to the joint base.
* Before inserting the hose into the
continuous drainage hole, remove
the rubber packing and drain seat.
Pull the joint elbow toward you and pull it out of the continuous drainage hole together with the hose.
Align the rubber packing with the hole in the drain seat, then insert these two parts firmly into the hole
of the drain stopper.
Re-install the water tank.
To stop continuous drainage and return
the dehumidifier to its original state
The unit does not operate without the water tank in place.
(The unit is turned off with water-brimmed direction device in the unit.)
Elbow joint
Commercial hose, 15mm internal
diameter.
Insert more
than 10mm
into hose.
Drain hose hole
WIDE SWING button
POWER ON/OFF button
Rear view
Continuous Drainage
E-15
How to Operate the Timer / Continuous Drainage
Positioning of the
drainage hose for
continuous
dehumidification
The hose must
be below the
level of the
drainage hole.
Do not bend
the hose.
The end of the
hose should
not come in
direct contact
with water.
At least 10cm
As explained in "Preparations before use" ( ) the AUTO OFF function will shut down the unit
automatically after 12 hours of normal operation. If you do not wish this function to work during continuous
drainage, you can cancel it as described below.
Plug in the power plug.
While pressing the WIDE SWING button in stopped condition, keep
the POWER ON/OFF button pressed for at least 3 seconds.
When setting is completed, there will be a beep sound, the
LED display indicates [ ] and the FULL TANK indicator
lights for 5 seconds.
To reactivate the AUTO OFF function, disconnect the
power plug from the wall outlet and carry out the procedure
described in above. After 3 seconds, the beep sounds
to indicate that setting is completed.
Elbow joint
Front view
Drainage outlet
Elbow joint
Rubber packing
Drain stopper
Drain seat
E-8
page
Attach the elbow joint to the other end of the hose inserted into the continuous drainage hole.
1
2
3
4
Press together
for at least
3 seconds
ENGLISH

DW-R249A_eng
A clogged filter will result in reduced dehumidification efficiency and higher power
consumption. It can also cause odor.
If you operate the unit without the filter, dust will accumulate in the unit, which may result in malfunction.
Main body
Wipe off any dirt from the unit using a piece of soft cloth soaked in warm water (40¡C max.) or with detergent.
(About once a month)
If detergent is used, make sure to wipe off the detergent with a damp cloth.
The air intake and outlet become dirty easily, so make sure to clean them well.
If water is allowed to splash on the unit, electrical insulation may be affected and corrosion of the unit may eventually result.
Use a neutral detergent (e.g. for dish washing) for cleaning.
Do not use the following types of cleaning agents as they will damage plastic parts.
Thinners, benzine, alcohol, petrol, powder soap, powder polish, alkaline washing agents, hot water, acid or scrubbing brushes.
Do not scrub or expose the unit to chemically treated cloths for any prolonged period of time as this may damage the surface of the unit.
Caution
Maintenance
For safety purposes, turn off and unplug the unit
before carrying out any maintenance.
For clean, sanitary and pro-long use, regular
maintenance is recommended.
E-16
Power supply
cord
Band
Empty the water tank completely.
Wind the power supply cord around the clamp on the rear panel.
If the unit is not used for a long time
Storage
Dry the unit thoroughly and cover with a sheet for dust protection. Store the unit in a well ventilated
place that is not exposed to direct sunlight. If the unit is left uncovered without any protection, dust
will accumulate so that the air emitted by the unit will be dusty next time the dehumidifier is used.
1
1
2
2
3
3
Clean the filter.
See above
See above
(1) Detach the tank lid gradually from the left or right toward the opposite side.
(2) Drop the tank handle to the front position as shown in the illustration on the
right, and slightly spread out the left and right side arms of the handle so that
the shafts come out, and remove the handle from the water tank.
(3) Push the float in the direction shown in the diagram and remove
it from the hole. With the float in this state, pull it out in direction .
(4) To reinstall, follow the above procedure in reverse ( ).
Float
Lever
Water
tank
* After having reinstalled these parts, make sure to move the float lever up and down with your finger to confirm that it moves smoothly.
If the float sticks, the overflow protection device located behind the lever will not work and the tank may overflow.
Removing and installing the tank lid, tank handle, and tank float.
Wash the inside of the water tank.
Wipe the water tank with a soft cloth, and install the tank lid, tank handle, and tank float.
(About once a week)
Water tank
If you do not insert the tank float securely, the tank can overflow, and the unit
will not stop. Take due care.
After prolonged use, the drain water may cause the tank to go black.
If this happens, wash the tank with a sponge, warm water and a mild detergent.
Remove the tank lid, tank handle and tank float, and wipe off any
excess water in the tank.
Filter
Filter (About once 2 weeks) * This filter is not intended for air
purification.
Dirty side up
Cleaning the filter
Remove dust and dirt with the corner tool of your vacuum cleaner.
If the filter is very dirty, wash it with neutral detergent diluted in
warm water. Rinse it off and let it dry well in the shade.

Dehumidifying operation increases room temperature.
(The dehumidifier does not have a cooling function.)
The unit generates heat during operation and will become warm. It will blow out warm air, but this is
normal and does not indicate a problem with the unit.
Defrosting
Dehumidification capacity will vary
based on room temperature and
humidity.
The temperature at which the unit can be operated is 5¡C to 35¡C.
If the room temperature is over 35¡C, the built-in protection system will automatically turn off the unit.
Follow the steps below to disable the tank full alarm:
(Operation stopped by AUTO OFF function)
To return to the previous condition, either carry out the procedure described
in again or disconnect the power plug from the wall outlet and plug it in
again to cancel the setting.
Wait for 3 minutes before restarting the unit
Canceling the beeps indicating FULL TANK and
OFF TIMER end
If the unit is turned off, wait for at least 3 minutes before restarting operation.
If the unit is restarted immediately, the compressor will wait for 3 minutes to start up as part of the unitÕs
self-protection system.
Plug the power plug into the socket.
When the PLASMACLUSTER and WIDE SWING buttons are pressed
simultaneously during operation stop for at least 3 seconds, the setting
beep sounds.
Press the POWER ON/OFF button and remove the drain tank. If the
beep does not sound, the setting is completed.
Dehumidification capacity will increase as
temperature rises (as shown in the chart
on the right).
In winter when the room temperature is
low (below 10¡C), use the dehumidifier in
combination with a room heater to reduce
the drying time.
E-17
If the room temperature is below 16¡C, frost may form on the cooling device of the dehumidifier,
and the automatic defrosting function will automatically switch on.
During defrosting, air flow is stopped and the sound of operation will change.
The length of time that defrosting will operate will vary according to room temperature and humidity, but
will be carried out about 5 minutes at 45 minute intervals. (The duration of a defrost cycle will be longer
when the temperature is lower.)
In case of CONTINUOUS
DEHUMIDIFY operation at
Full power mode.
Room temperature (¡C)
In case of 80%
in humidity.
Dehumidifying capacity (L/day)
Things to remember
DW-R249A_eng
PLASMACLUSTER button
WIDE SWING button
Press together for 3 seconds
Maintenance / Things to remember / Defrosting
0
0
10
15
20
25
15 20 25 30
ENGLISH

DW-R249A_eng
E-18
Symptoms Check Points
Is the water tank installed properly?
Is the water tank full?
Is the unit plugged in properly?
Has there been a power failure?
Is the LED display displaying [ ]?
If it is, disconnect the power plug and contact the shop where you purchased the unit.
Unit does not operate
when power ON/OFF
button is pressed.
Water is leaking.
Error Codes
Has the unit been knocked over, or has it been tilted or dropped?
Is the pipe connection or hose connection for continuous drainage in place?
Is the humidity being automatically controlled using AUTO DEHUMIDIFY,
MOLD ATTACK, CONTINUOUS DEHUMIDIFY, or DRY CLOTHES mode?
(See pages E-9
~
E-11.)
If [ ] continues to appear after checking the problem based on page E-4,
"Cautions for Use", disconnect the power plug and contact the shop
where you purchased the product or your nearest SHARP Service Center.
Dehumidification
capacity has dropped.
Is the filter clogged?
Is the air outlet or intake obstructed?
Is the temperature and humidity of your room too low?
Humidity does not reduce
in any of the operating mode.
[]
lights on the LED
display and operation stops.
Is the room too large?
Are there much opening and closing of a window or an entrance?
Are there any appliances which make steam such as an oilstove?
This sound is generated during CLUSTER ION operation.
If the sound bothers you at bedtime, move the unit further away.
Depending on the humidity in the room, the operating noise may become
louder or less loud, or at times no sound may be heard at all. There is no
relationship with the CLUSTER ION effect.
Displayed humidity is
different from actual
humidity.
Intermittent
operating sound.
The unit repeats operating
and stopping.
Displayed humidity is changed suddenly by opening and closing of a window or
an entrance, changing the wind direction when operation is beginning. It is normal.
Displayed humidity indicates the ambient humidity around the unit.
This may be different to the humidity in a different location in the same room.
Operation is noisy.
Is the dehumidifier properly installed on a stable base?
Is the floor flat?
When the unit starts its operation at a low temperature, the sound might increase
for several seconds. (The time depends on the temperature condition.)
Before Calling for Service
LED Display Description Remedy
Defrosting exceeded 30 minutes
Defrosting thermistor defective
Room temperature sensor defective
Power clock abnormal
Gas leak detected
Compressor locked
Disconnect the power
plug and contact the
shop where you
purchased the product.
?
Table of contents
Other Sharp Dehumidifier manuals

Sharp
Sharp DW-E16FA-W User manual

Sharp
Sharp DW-E16FA User manual

Sharp
Sharp DW-P22A User manual

Sharp
Sharp DW-71-H User manual

Sharp
Sharp DW-J27A User manual

Sharp
Sharp DW-J27FA User manual

Sharp
Sharp DW-209EX User manual

Sharp
Sharp Plasmacluster DW-J27FV User manual

Sharp
Sharp DW-RN23A-W User manual

Sharp
Sharp DW-D20A User manual