SICK ES21 M12 contact User manual

OPERATING INSTRUCTIONS
ES21 M12 contact
Safety switches

Described product
ES21 M12 contact
Manufacturer
SICK AG
Erwin-Sick-Str. 1
79183 Waldkirch
Germany
Legal information
This work is protected by copyright. Any rights derived from the copyright shall be
reserved for SICK AG. Reproduction of this document or parts of this document is
only permissible within the limits of the legal determination of Copyright Law. Any modi‐
fication, abridgment or translation of this document is prohibited without the express
written permission of SICK AG.
The trademarks stated in this document are the property of their respective owner.
© SICK AG. All rights reserved.
Original document
This document is an original document of SICK AG.
2O P E R A T I N G I N S T R U C T I O N S | ES21 M12 contact 8027995/2023-07-28 | SICK
Subject to change without notice

Contents
1 About this document........................................................................ 4
2 On safety............................................................................................. 5
2.1 Area of use................................................................................................ 5
2.2 Qualified personnel.................................................................................. 5
3 Product description........................................................................... 6
3.1 Items supplied.......................................................................................... 6
3.2 Structure and function............................................................................. 6
4 Mounting and electrical installation............................................... 7
4.1 Mounting and connecting built-in version............................................... 7
5 Checks before initial commissioning............................................. 9
6 Recurring technical checks.............................................................. 10
7 Response to malfunctions............................................................... 11
8 Deinstallation..................................................................................... 12
9 Disposal.............................................................................................. 13
10 Technical specifications................................................................... 14
11 Dimensional drawings...................................................................... 16
12 Conformities and certificates.......................................................... 17
12.1 EU declaration of conformity.................................................................... 17
12.2 UK declaration of conformity................................................................... 17
13 Ordering information........................................................................ 18
CONTENTS
8027995/2023-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ES21 M12 contact 3
Subject to change without notice

1 About this document
These operating instructions are original operating instructions.
1 ABOUT THIS DOCUMENT
4O P E R A T I N G I N S T R U C T I O N S | ES21 M12 contact 8027995/2023-07-28 | SICK
Subject to change without notice

2 On safety
Read these operating instructions carefully and keep them in a safe place.
The operating instructions are to be provided to the person who is installing the emer‐
gency stop pushbutton.
DANGER
►Always note and follow the warnings below!
•Before starting the installation, electrically isolate system and device!
•Emergency stop pushbuttons provide a personnel protection function. Incorrect
installation or manipulation can result in serious injuries!
•Emergency stop pushbuttons are not allowed to be bypassed, removed or ren‐
dered ineffective in any other manner!
•The switching process is only allowed to be triggered by suitable pushbuttons that
are securely fastened to the switching element!
•Use suitable connections for the switching element!
•Incorrect installation or tampering can result in damage to the machine and
workpiece!
•The emergency stop function is not allowed to be used as a replacement for
protective measures or other safety functions, instead it should be designed as an
additional protective measure.
•The emergency stop function is not allowed to degrade the effectiveness of protec‐
tive devices or other devices with safety functions.
•Based on a risk analysis, the designer must ensure that the emergency stop
achieves the required level of safety (SIL, SILCL or PL) in combination with control
system.
2.1 Area of use
National and international legal specifications apply to the installation and use of the
emergency stop pushbutton, to its commissioning, and to recurring technical inspec‐
tions, in particular:
•The Machinery Directive
•The Low Voltage Directive
•The safety regulations
•The work safety regulations and safety regulations
The manufacturer and user of the machine on which the protective devices are used
are responsible for liaising with the relevant authorities about all applicable safety
regulations/rules and for ensuring compliance with these.
Intended use also includes regular monitoring of the protective device by qualified
safety personnel.
The product may be used in safety functions.
2.2 Qualified personnel
The emergency stop pushbutton may be mounted, put into operation, checked, main‐
tained, or used only by qualified safety personnel.
A person who satisfies all the following conditions is deemed properly qualified:
•Appropriate technical training
•Instruction of the machine operator in machine operation and the applicable
safety guidelines
•Access to these operating instructions
ON SAFETY 2
8027995/2023-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ES21 M12 contact 5
Subject to change without notice

3 Product description
3.1 Items supplied
•Complete set with pushbutton including switching element in one package
•Safety note
3.2 Structure and function
The emergency stop pushbutton consists of a pushbutton and an integrated switching
element. The emergency stop pushbutton is a pre-assembled complete device (built-in
version).
When the pushbutton is pressed, the switching element is actuated and the contacts
opened. This allows an emergency stop to be triggered.
The pushbutton engages when pressed and then has to be unlocked manually by
turning the pushbutton.
3 PRODUCT DESCRIPTION
6O P E R A T I N G I N S T R U C T I O N S | ES21 M12 contact 8027995/2023-07-28 | SICK
Subject to change without notice

4 Mounting and electrical installation
4.1 Mounting and connecting built-in version
Approach
1. Planning mounting location: The emergency stop pushbutton must be easily
accessible in the event of an emergency.
2. Drill mounting hole with Ø 22.3mm in the mounting plate.
3. Make sure the surface is smooth to ensure tightness.
4. Insert emergency stop pushbutton through the mounting hole and fasten with nut
(max. tightening torque 1.7Nm) (see table 3, page 14).
Figure 1: Mounting ES21 mini
5. Connect the connecting cable to the male connector (max. tightening torque
0.4Nm).
6. Protect the connecting cable with strain relief. The male connector must not be
strained. For device variants with cable, observe the specified bend radii (see
table 3, page 14).
7. Attach connecting cable to control unit ( see table 1, page 7 and see table 2,
page 8)
Table 1: Pin assignment ES21-MB16Sx
ES21-MB16Sx PIN Description
2 1
4
3
Figure 2: M12 4-pin A-
coded male connector
1 N/C contact
2
3 N/C contact
4
MOUNTING AND ELECTRICAL INSTALLATION 4
8027995/2023-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ES21 M12 contact 7
Subject to change without notice

Table 2: Pin assignment ES21-MB16R5
ES21-MB16R5 PIN Description
2 1
4
3
5
Figure 3: M12 male con‐
nector, 5-pin, A-coded
1 Normally closed contact
4
2 Normally closed contact
5
3 Normally open contact
5
4 MOUNTING AND ELECTRICAL INSTALLATION
8O P E R A T I N G I N S T R U C T I O N S | ES21 M12 contact 8027995/2023-07-28 | SICK
Subject to change without notice

5 Checks before initial commissioning
Mechanical function check-out
•The emergency stop pushbutton is fastened so that it cannot be turned.
•The nut is tightened so that no gap is detectable in the longitudinal direction.
•The pushbutton engages when actuated.
•The pushbutton can be unlocked by turning it.
Electrical function check-out
1. Start the machine.
2. Actuate the pushbutton.
DANGER
Check that the machine stops!
►Check whether the machine stops when the emergency stop pushbutton is
actuated.
CHECKS BEFORE INITIAL COMMISSIONING 5
8027995/2023-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ES21 M12 contact 9
Subject to change without notice

6 Recurring technical checks
Do regular monitoring to ensure smooth and permanent function. The inspection inter‐
val must be determined by the machine designer using the risk assessment. However,
we recommend having the emergency stop pushbutton triggered at least once a year
by the responsible safety representative for test purposes and checking for proper
function:
•Mechanical and electrical function test, see "Checks before initial commissioning",
page 9
•Safe mounting of components
•No manipulation and damage detectable
•Cable entry tightness
•No loose cable connections
6 RECURRING TECHNICAL CHECKS
10 O P E R A T I N G I N S T R U C T I O N S | ES21 M12 contact 8027995/2023-07-28 | SICK
Subject to change without notice

7 Response to malfunctions
DANGER
In the event of mechanical overload or external exertion of force, the emergency stop
pushbutton can be damaged and the function impaired.
►Perform a function test in this case, see "Checks before initial commissioning",
page 9.
RESPONSE TO MALFUNCTIONS 7
8027995/2023-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ES21 M12 contact 11
Subject to change without notice

8 Deinstallation
DANGER
►Disconnect the system and device from the mains before beginning disassembly!
8 DEINSTALLATION
12 O P E R A T I N G I N S T R U C T I O N S | ES21 M12 contact 8027995/2023-07-28 | SICK
Subject to change without notice

9 Disposal
Approach
►Always dispose of unusable devices in accordance with national waste disposal
regulations.
Complementary information
SICK will be glad to help you dispose of these devices on request.
DISPOSAL 9
8027995/2023-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ES21 M12 contact 13
Subject to change without notice

10 Technical specifications
Table 3: Technical data for ES21 M12 contact
ES21-MB16S2 ES21-MB16S4 ES21-MB16R5
Enclosure rating from front (EN
60529)
IP65/IP67
Enclosure rating from rear (EN
60529)
IP65/IP67 (with connected male connector)
Ambient operating temperature –25°C … +70°C
Storage temperature –40°C … +80°C
Switching elements 2 positive opening normally closed
contacts
2 positive open‐
ing normally
closed contacts
1 N/O contact
B10d value 250,000 switching operations 226,000 switch‐
ing operations
Electrical/Mechanical service life (at
+20°C)
50,000 switching operations (at nominal load)
Max. NC bounce time <10ms
Specific insulation resistance <100mOhm, typi‐
cally 50mOhm
<50mOhm <50mOhm
Utilization category: AC-15
DC-13
Rated insulation voltage Ui250V 50V
Rated voltage Ue35V
Rated current IeAC-15: 4A
DC-13:2A
AC-15: 2A
DC-13:2A
Switching capacity AC-15: 10le
DC-13: 1.1le
Thermal continuous current lth4A 2A
Short-circuit protection Fuse 4AgG Fuse 2AgG
Conditional rated short-circuit current 1,000A
Overvoltage category II
Degree of contamination 2
Rated impulse withstand voltage Uimp2,500V (contact element)
Max. nut torque 1.0Nm … 1.7Nm
Max. M12 male connector torque 0.4Nm
Installation diameter 22.3mm
Actuating force ~ 30N (20mm/min)
Connection M12 male connector, 4-pin, A-coded M12 male con‐
nector, 5-pin, A-
coded
Length of cable 25cm ±3cm – –
Cable material PUR – –
Cable diameter 4.7mm – –
Conductor cross section 0.34mm² (AWG22) – –
Bend radius (with fixed installation) >10 × cable diam‐
eter
– –
10 TECHNICAL SPECIFICATIONS
14 O P E R A T I N G I N S T R U C T I O N S | ES21 M12 contact 8027995/2023-07-28 | SICK
Subject to change without notice

ES21-MB16S2 ES21-MB16S4 ES21-MB16R5
Bend radius (for flexible use) >5 × cable diame‐
ter
– –
Contact material AgNi
Housing material PA (polyamide)
Weight 45g 20g 21g
Specifications according to UL/IEC 60947-5-5
Ratings 30V AC/DC 3A 35Vdc/2A,
35Vac/3A
Ith 3A, Ui 250V
35V AC/DC 2A
Ith 2A, Ui 50V
Torque 1.3 … 1.9 Nm
(Head Nut)
1.0 … 1.7 Nm (Head Nut)
Enclosure Type Type 4X (Indoor) front face
TECHNICAL SPECIFICATIONS 10
8027995/2023-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ES21 M12 contact 15
Subject to change without notice

11 Dimensional drawings
28Ø
15Ø
26
1...4,5
250±30
40,7 9
M12
M22
Figure 4: Dimensional drawing for the ES21-MB16S2
28
Ø
2627
1...4,5
M12
M22
Figure 5: Dimensional drawing for the ES21-MB16S4 and ES21-MB16R5
11 DIMENSIONAL DRAWINGS
16 O P E R A T I N G I N S T R U C T I O N S | ES21 M12 contact 8027995/2023-07-28 | SICK
Subject to change without notice

12 Conformities and certificates
You can obtain declarations of conformity, certificates, and the current operating
instructions for the product at www.sick.com. To do so, enter the product part number
in the search field (part number: see the entry in the “P/N” or “Ident. no.” field on the
type label).
12.1 EU declaration of conformity
Excerpt
The undersigned, representing the manufacturer, herewith declares that the product is
in conformity with the provisions of the following EU directive(s) (including all applicable
amendments), and that the standards and/or technical specifications stated in the EU
declaration of conformity have been used as a basis for this.
•ROHS DIRECTIVE 2011/65/EU
•MACHINERY DIRECTIVE 2006/42/EC
12.2 UK declaration of conformity
Excerpt
The undersigned, representing the following manufacturer herewith declares that this
declaration of conformity is issued under the sole responsibility of the manufacturer.
The product of this declaration is in conformity with the provisions of the following
relevant UK Statutory Instruments (including all applicable amendments), and the
respective standards and/or technical specifications have been used as a basis.
•Restriction of the Use of Certain Hazardous Substances in Electrical and Elec‐
tronic Equipment Regulations 2012
•Supply of Machinery (Safety) Regulations 2008
CONFORMITIES AND CERTIFICATES 12
8027995/2023-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ES21 M12 contact 17
Subject to change without notice

13 Ordering information
Table 4: ES21 M12 contact ordering information
Switching ele‐
ments
Connection Type code Part number
2 positive open‐
ing normally
closed contacts
M12 male connector, 4-pin,
A-coded, with cable
ES21-MB16S2 6082622
2 positive open‐
ing normally
closed contacts
M12 male connector, 4-pin,
A-coded
ES21-MB16S4 6082623
2 positive open‐
ing normally
closed contacts
1 N/O contact
M12 male connector, 5-pin,
A-coded
ES21-MB16R5 6083130
13 ORDERING INFORMATION
18 O P E R A T I N G I N S T R U C T I O N S | ES21 M12 contact 8027995/2023-07-28 | SICK
Subject to change without notice

ORDERING INFORMATION 13
8027995/2023-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ES21 M12 contact 19
Subject to change without notice

Detailed addresses and further locations at www.sick.com
Australia
Phone +61 (3) 9457 0600
1800 33 48 02 – tollfree
E-Mail [email protected]
Austria
Phone +43 (0) 2236 62288-0
E-Mail [email protected]
Belgium/Luxembourg
Phone +32 (0) 2 466 55 66
E-Mail info@sick.be
Brazil
Phone +55 11 3215-4900
E-Mail [email protected]
Canada
Phone +1 905.771.1444
E-Mail [email protected]
Czech Republic
Phone +420 234 719 500
E-Mail [email protected]
Chile
Phone +56 (2) 2274 7430
E-Mail [email protected]
China
Phone +86 20 2882 3600
E-Mail info[email protected]
Denmark
Phone +45 45 82 64 00
E-Mail [email protected]
Finland
Phone +358-9-25 15 800
E-Mail [email protected]
France
Phone +33 1 64 62 35 00
E-Mail info@sick.fr
Germany
Phone +49 (0) 2 11 53 010
E-Mail info@sick.de
Greece
Phone +30 210 6825100
E-Mail [email protected]
Hong Kong
Phone +852 2153 6300
E-Mail [email protected]
Hungary
Phone +36 1 371 2680
E-Mail ertek[email protected]
India
Phone +91-22-6119 8900
E-Mail info@sick-india.com
Israel
Phone +972 97110 11
E-Mail info@sick-sensors.com
Italy
Phone +39 02 27 43 41
E-Mail info@sick.it
Japan
Phone +81 3 5309 2112
E-Mail [email protected]
Malaysia
Phone +603-8080 7425
E-Mail enquiry[email protected]
Mexico
Phone +52 (472) 748 9451
E-Mail me[email protected]
Netherlands
Phone +31 (0) 30 204 40 00
E-Mail info@sick.nl
New Zealand
Phone +64 9 415 0459
0800 222 278 – tollfree
E-Mail [email protected]z
Norway
Phone +47 67 81 50 00
E-Mail [email protected]
Poland
Phone +48 22 539 41 00
E-Mail info@sick.pl
Romania
Phone +40 356-17 11 20
E-Mail [email protected]
Singapore
Phone +65 6744 3732
E-Mail [email protected]
Slovakia
Phone +421 482 901 201
E-Mail mail@sick-sk.sk
Slovenia
Phone +386 591 78849
E-Mail [email protected]
South Africa
Phone +27 10 060 0550
E-Mail info@sickautomation.co.za
South Korea
Phone +82 2 786 6321/4
Spain
Phone +34 93 480 31 00
E-Mail info@sick.es
Sweden
Phone +46 10 110 10 00
E-Mail info@sick.se
Switzerland
Phone +41 41 619 29 39
E-Mail [email protected]
Taiwan
Phone +886-2-2375-6288
E-Mail [email protected]
Thailand
Phone +66 2 645 0009
E-Mail marcom.th@sick.com
Turkey
Phone +90 (216) 528 50 00
E-Mail info@sick.com.tr
United Arab Emirates
Phone +971 (0) 4 88 65 878
E-Mail [email protected]
United Kingdom
Phone +44 (0)17278 31121
E-Mail info@sick.co.uk
USA
Phone +1 800.325.7425
E-Mail info@sick.com
Vietnam
Phone +65 6744 3732
E-Mail [email protected]
SICK AG|Waldkirch|Germany|www.sick.com
8027995/2023-07-28/en
Table of contents
Other SICK Switch manuals
Popular Switch manuals by other brands

Brocade Communications Systems
Brocade Communications Systems DCX 8510-4 quick start guide

ATTE
ATTE IPUPS-5-11-XL2 user manual

Safe Signal
Safe Signal EPS10 Series Installation and maintenance instructions

Philips
Philips SWS6813T Specifications

Magnetrol
Magnetrol Thermatel TD1 Installation and operating manual

Vivotek
Vivotek AW-GEV-104A Series User manual and warranty statement