
CP 443-5 Extended
Manual, 11/2018, C79000-G8976-C162-09 7
Preface ................................................................................................................................................... 3
1 Application and functions ........................................................................................................................ 9
1.1 Application ................................................................................................................................9
1.2 Communication services...........................................................................................................9
1.3 Requirements for use..............................................................................................................12
1.3.1 Use with the current CPU types..............................................................................................12
1.3.2 Converting older systems .......................................................................................................14
1.3.3 Project engineering .................................................................................................................15
1.3.4 Programming ..........................................................................................................................16
1.4 Performance data ...................................................................................................................17
1.4.1 Transmission speeds supported.............................................................................................17
1.4.2 Characteristic data of the DP interface ...................................................................................17
1.4.3 Characteristic data of open communications services (SEND/RECEIVE interface) over
FDL connections .....................................................................................................................19
1.4.4 Characteristics of S7 communication .....................................................................................19
1.4.5 Parallel use of communications services (multiprotocol mode)..............................................20
1.4.6 Time-of-day synchronization...................................................................................................21
1.4.7 Data record routing .................................................................................................................22
1.4.8 Use in faulttolerant systems....................................................................................................22
1.4.9 Other characteristics ...............................................................................................................23
1.5 Compatibility with previous product ........................................................................................24
1.5.1 Extended functionality compared with previous product ........................................................24
1.5.2 Replacing older modules / module replacement ....................................................................25
2 Displays and mode selector .................................................................................................................. 27
3 Installation and commissioning.............................................................................................................. 29
3.1 Important notes on using the device.......................................................................................29
3.1.1 Notes on use in hazardous areas ...........................................................................................29
3.1.2 Notes on use in hazardous areas according to ATEX / IECEx ..............................................30
3.1.3 Notes on use in hazardous areas according to UL HazLoc ...................................................31
3.2 Installation and commissioning...............................................................................................31
4 Notes on operation................................................................................................................................ 33
4.1 General operation on PROFIBUS...........................................................................................33
4.2 Display "Existing channel error" in the diagnostics interrupt OB (OB82) ...............................34
4.3 Display of the the DP slave history .........................................................................................34
4.4 Other information available about the CP...............................................................................34
5 Technical specifications ........................................................................................................................ 35
A Approvals.............................................................................................................................................. 37