manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Siemens
  6. •
  7. Industrial Equipment
  8. •
  9. Siemens Climatix ECO POL224.00 User manual

Siemens Climatix ECO POL224.00 User manual

Climatix ECO
POL224.00, POL224.05
Free cooling with sensors, actuators, thermostats, fans and compressors
●Free cooling based on single or dual dry bulb temperature, or combination
temperature + humidity sensors
●Automatic switch-over for different control modes
●Parameter settings based on climate zone, using GPS functionality in the Climatix
Mobile application
●LED indication for free cooling operation, sensor operation and damper operation
●Quick installation and easy commissioning with Climatix Mobile application
●User Interface for normal operation, parameter setup and alarm notifications with
an LCD display and three operation buttons
●RS485 port for BACnet MSTP slave or Modbus RTU slave communication
●USB interface for firmware updates and WLAN connection
●QR codes for quick access to download Climatix Mobile application and user
documentation
A6V11681604_enUS_b
Smart Infrastructure
2022-05-25
2
Siemens
A6V11681604_enUS_b
Smart Infrastructure
2022-05-25
Use The Economizer Controller works in combination with a range of sensors, damper actuators,
thermostat, fans and compressors to make use of unconditioned outside air to cool a
building and improve inside air quality.
Features
●Flexible sensor inputs accept Type II NTC 10K or 0-10 Vdc standard sensors, or
Siemens QFM2160U or QFR9530 combination temperature/humidity sensor for enthalpy
control
●Can be used with Siemens OpenAir® damper actuator GQD, GMA or GCA series
●24Vac digital inputs for indication of occupancy, 3-stage Cooling Stage input, Shutdown,
Heat Conventional, Heat Pump Changeover (HP(B)/HP(O)) or Preoccupancy
●24Vac relay outputs (digital) for 3-stage Cooling Stage output, Exhaust Fan, VFD On/Off
(Variable Speed Supply Fan Enable), System Alarm output (Title 24) or Energy
Recovery Ventilation (ERV)
●Anti-freeze protection
●Fault detection and alarming
●Brownout protection
Technical Design The Economizer Controller has 7 analog inputs, 2 analog outputs, 5 digital inputs, 4 digital
outputs, an RS485 port and a USB host interface. POL224.00 is additionally equipped with a
housing (front and rear, snap-on design), three LEDs, three operation buttons and inbuilt
HMI. Customers can operate on the device directly if no mobile application is connected.
3
Siemens
A6V11681604_enUS_b
Smart Infrastructure
2022-05-25
No.
Description
1
One-line LCD
2
Free cooling LED
3
Sensor LED
4
DAC (damper actuator) LED
5
Operation button (UP button) - Move to the previous value, step or category
6
Operation button (Down button)- Move to the next value, step or category
7
Operation button (Enter button):
●Press to edit the current value or option.
●Press to confirm a newly selected value or option.
●Press Enter + Up to jump up one entire category.
●Press Enter + Down to jump down one entire category.
8
Configurable I/Os (AUX1-I, AUX1-O and AUX2-I, AUX2-O) for additional stages of
cooling, shutdown, heat conventional (W1), heat pump changeover (reversing
valve O/B), or preoccupancy.
9
5 I/Os (Y1I, Y1O, Y2I, Y2O and OCC) for stages of cooling and occupancy for the
thermostat connections
10
●2 analog outputs (ACT 2-10 Vdc and VFD 0-10 Vdc) for 2-10 Vdc Damper
actuator and 0-10 Vdc VFD
●1 analog input for ACT-FB
11
●6 analog inputs (OAT, RAT, OAH, RAH, MAT and AUX-AI) for:
–Type II NTC 10K or 0-10 Vdc outside air sensor, return air sensor, mixed
air sensor or discharge air sensor
–0-10 Vdc or 4-20mA combo temperature and humidity sensor
–0-10 Vdc air quality sensor or pressure sensor
12
RS485 port
13
USB host interface for WLAN stick (POL903.00/100)
LED Indication
Status
Free Cooling LED
Sensor LED
DAC LED
Commissioning mode
Yellow Blinking
Yellow Blinking
Yellow Blinking
Power start-up
Yellow On
Yellow On
Yellow On
Free cooling is running
Green On
-
-
Free cooling is available but not
running
Green Blinking
-
-
Not economizing when it should
Red Blinking
-
-
Economizing when it should not
Red On
-
-
Sensors working ok
-
Green On
-
4
Siemens
A6V11681604_enUS_b
Smart Infrastructure
2022-05-25
Status
Free Cooling LED
Sensor LED
DAC LED
Humidity sensor error
-
Yellow On
-
CO2sensor error
-
LED Off
-
Air temperature failure/fault
-
Red On
-
Excess outdoor air
-
Red Blinking
-
Damper working ok
-
-
Green On
Damper stalled
-
-
Red On
Damper slippage
-
-
Red Blinking
Actuator alarm is reported
-
-
Fast Red Blinking
Terminal ACT-FB is configured
but no available feedback
signal (under-range or over-
range)
-
-
LED Off
NOTICE
If different faulty events occur at the same time, sensor/DAC LED lights up following the
priority below: Red (Fast Blinking) -> Red (On, Steady) -> Red (Blinking) -> Yellow -> Off ->
Green. For example, if there is a humidity sensor error and air temperature failure at the
same time, the sensor LED turns red rather than yellow.
After the Economizer controller enters the running state, it may take one minute for
peripheral devices to complete initialization. Before that, LED indication might be unstable.
Type Summary
Type
Order number
Description
POL224.00
S55392-C202-A100
POL224.00 Title24 Economizer Controller
POL224.05
S55392-C203-A100
POL224.05 Title24 Econ Cont, no housing
Order and Delivery
When ordering, provide both name and type reference, e.g. Economizer Controller,
POL224.00.
5
Siemens
A6V11681604_enUS_b
Smart Infrastructure
2022-05-25
Equipment Combinations
Type of Unit
Description
Specification
Part Number
Datasheet*
Damper
Actuator
Spring Return, 2 to
10 Vdc Signal, Plenum-
rated
20 lb.-in.
GQD series,
e.g.,
GQD151.1P
155-760
Spring Return, 2 to
10 Vdc Signal, Plenum-
rated
62 lb.-in.
GMA series,
e.g.,
GMA151.1P
155-315P25
Spring Return, 2 to
10 Vdc Signal, Plenum-
rated
160 lb.-in.
GCA series,
e.g.,
GCA151.1P
155-173P25
CO2 Sensor
0-2000 ppm, IP30
0-10 Vdc
QPA2000
CE1N1961
Combo Temp
+ Humidity
Sensor
5% Duct RH Temp
Sensor
0-10 Vdc
(temperature
and humidity
sensing)
QFM2160U
155-748
Duct sensor for
acquiring temperature,
relative humidity
Type II NTC 10K
(temperature
sensing)
0-10 Vdc
(humidity
sensing)
QFR9530
A6V11937911
Temperature
Sensor
4-inch, Duct Point
Temperature Sensor
Type II NTC 10K
QAM2030.010
149-915
Duct sensor for
acquiring temperature
Type II NTC 10K
QAR9530
A6V11937911
Humidity
Sensor
Duct sensor for
acquiring relative
humidity
0-10 Vdc
QFR9500
A6V11937911
Commercial
Thermostat
Programmable
Thermostat
24 Vac
RDS120
RDY2000
A6V10807603
149-200
* The documents can be downloaded from Siemens US Download Center or
http://siemens.com/bt/download by specifying the datasheet number or part number as
shown in the above table.
6
Siemens
A6V11681604_enUS_b
Smart Infrastructure
2022-05-25
Accessories
A WLAN stick needs to be connected to the product via the USB host interface during
commissioning with the Climatix Mobile application.
Type of unit
Product no.
Datasheet*
WLAN stick
POL903.00/100
S55803-Y130-A100
CC1N7219en
NOTE: Accessories are not included with the unit and should be ordered separately.
* The document can be downloaded from http://siemens.com/bt/download by specifying the
product number as shown in the above table. Relevant data such as SSID, password for the
terminal unit and web interface for configuration can be found in the document.
Product Documentation
Title
Document ID
Mounting instructions
A6V11997548
Application manual
A6V12031524
CE declaration
A5W00148475A
RCM conformity
A5W00148474A
Product environmental declaration
A5W00068298A
All documentation can be downloaded at Siemens US Download Center.
Notes
Security
CAUTION
National safety regulations
Failure to comply with national safety regulations may result in personal injury and property
damage.
●Observe national provisions and comply with the appropriate safety regulations.
Mounting The Economizer Controller can be mounted to sheet metal ductwork. When mounting, note
the following:
●Mount the controller in a position that allows clearance for wiring, servicing, and removal.
See Mounting Instructions for required mounting clearances.
●(For POL224.05) four spacers (M3.5 x L (L ≥10 mm) ) and four M3.5 screws are
required. Metal spacers are recommended.
●(For POL224.00) two No. 6 3/4” self-tapping screws are required.
●Siemens does not provide screws or spacers with the product. They must be obtained
separately.
7
Siemens
A6V11681604_enUS_b
Smart Infrastructure
2022-05-25
Wiring Use only class 2 rated power source with proper current limiting.
●Use only class 2 rated power source with proper current limiting.
●Disconnect power supply before beginning wiring, or making wiring connections, to
prevent electrical shock or equipment damage.
Commissioning Commissioning configures I/Os and tests the damper operation and any configured outputs.
It can only be done using the Climatix Mobile application or under Configuration State from
the controller. The three LEDs blink yellow if the controller enters Configuration State.
To Commission under the controller’s Configuration State
a)From the default HMI screen, press Enter + Up.
The '5CONFIG STATE' screen displays.
b)Press Enter, and then confirm the switch by pressing Enter again.
c) Configure I/Os and/or test connected devices.
d)If configurations are done, press Enter + Up or Down to switch to the '8RUN STATE'
screen, then press Enter twice to go back to Running State.
The '1FREECOOL' screen displays.
Commissioning is also possible from the mobile application. See Product Documentation
[▶6] for more information.
Don't interrupt damper test once it starts.
Operation Customers can download the mobile application by scanning the Mobile APP QR code on
the device and perform operations on their smartphones or tablets or directly on the device.
When performing operations from the mobile application, ensure that a WLAN stick is
plugged into the USB port and connection between the smartphone/tablet and the WLAN
network is established.
Operations that can be performed from the local device are as follows:
●Change basic settings like the following:
–Temperature shutoff setpoint
–Enthalpy shutoff setpoint if an RH input is detected
–Mixed-air temperature modulating setpoint
–The ppm value for DCV (Demand Control Ventilation)
–Damper minimum position
–Temperature unit
–Fan airflow or CFM value
–ERV (Energy Recovery Ventilation) outside air temperature setpoint if 'ERV' is
selected for AUX1-O or AUX2-O
–Exhaust fan startup setpoint if exhaust fan is chosen
–Etc.
●Change advanced settings like the following:
–Damper position anti-freeze protection settings
–Damper position during shutdown
–Highest stage cooling delay time
–Min. and max. leaving air temperature
8
Siemens
A6V11681604_enUS_b
Smart Infrastructure
2022-05-25
–Calibration values for sensors
–Anti-freeze protection
–Etc.
●Configure I/Os.
●Test the damper operation and any configured outputs.
NOTICE
Not all operations can be performed on the local device. Operations on the local device are
only recommended if operations from the mobile application are unavailable. See the
mobile commissioning guide for all operations that can be performed from the mobile
application end.
Operating System
Supported smartphone types are as follows:
OS
OS version
App Store
iOS
iOS 10 or above
App Store®
Android
AndroidTM 6.0 or above
Google PlayTM
Disposal
The device is considered an electronic device for disposal in accordance
with European Directive and may not be disposed of as domestic waste.
●Use only designated channels for disposing the devices.
●Comply with all local and currently applicable laws and regulations.
Open Source Software (OSS)
Software license overview
These devices use Open Source Software (OSS). All Open Source Software components
used in the product (to include copyrights and licensing agreement) are available at
http://siemens.com/bt/download.
Firmware version
OSS document
Device
Document ID
Title
0.1.23
A6V12190255
Readme OSS - Economizer RTU
Controller
POL224.00
POL224.05
9
Siemens
A6V11681604_enUS_b
Smart Infrastructure
2022-05-25
FCC
FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
●Reorient or relocate the receiving antenna.
●Increase the separation between the equipment and receiver.
●Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
●Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference, and
2. this device must accept any interference received, including interference that may cause
undesired operation
FCC Caution: Changes or modifications not expressly approved by Siemens Switzerland
Ltd. could void user authority to operate the equipment. United States representative
https://new.siemens.com/us/en/products/buildingtechnologies/home.html
ICES CAN ICES-3 (B)/NMB-3(B)
10
Siemens
A6V11681604_enUS_b
Smart Infrastructure
2022-05-25
Technical Data IMPORTANT All inputs and outputs must be Class 2 (100 VA) wiring.
Power supply
Power supply
Rated voltage
24Vac (20 Vac~30 Vac)
Frequency
50/60 Hz
Transformer
Max. 100 VA
Inputs
Sensors
Combination Temperature/Humidity
Sensor (e.g., QFM2160U)
5-wire (18, 20, or 22 AWG cable) connection
Dry Bulb Temperature Sensor Type II NTC
10K (e.g., QAM2030.010) or 0-10 Vdc
2-wire (18, 20, or 22 AWG cable) connection
Demand Control Ventilation (DCV) Sensor
(e.g., QPA2000)
3- wire (18, 20, or 22 AWG cable)
0 to 10 Vdc control signal
Detailed technical data are available in the documentation of the corresponding sensor.
Digital inputs
24 Vac power supply
24Vac (20 Vac~30 Vac)
Frequency
50/60 Hz
Wiring
1-wire 24 Vac + common GND
Outputs
Actuator (e.g., GCA151.1P)
4-wire (18 AWG)
Actuator Signal
2 to 10 Vdc
Actuator Input Resistance
100K ohm
VFD Signal
0 to 10 Vdc
Relay contact ratings
30 Vac (maximum power from class 2 input
only), 3A run, and 7.5A inrush
Detailed technical data are available in the documentation of the corresponding actuator.
11
Siemens
A6V11681604_enUS_b
Smart Infrastructure
2022-05-25
Connections
Interfaces
USB port
A service port limited for firmware updates and
commissioning from a smartphone or tablet
RS485 port
A service port for Modbus RTU (slave) or
BACnet MSTP communication (slave)
Wiring connections
Crimp Style connector
Solid wires or prepared stranded wires:
22 to 16 AWG (0.3...1.3 mm2)
Conformity
Ambient conditions and protection classification
Safety class as per EN60730
Class III
Degree of protection of housing as per
EN 60529
●POL224.00: IP20
●POL224.05: IP00
Classification as per EN 60730
Function of automatic control devices
Operation altitude
Degree of contamination
Overvoltage category
Type 1
< 3000 m
2
III
Climatic ambient conditions
Transport (packaged for transport) as per
EN 60721-3-2
Storage as per EN 60721-3-1
Operation as per EN 60721-3-3
Transport/Storage:
Temperature -40°F to 158°F (-40 °C to 70°C)
Air humidity 5...95% r.h. (non-condensing)
Operation (Comply to Class 3K5):
Temperature -40°F to 158°F (-40 °C to 70°C)
(excluding HMI)
Air humidity 5...95% r.h. (non-condensing)
Mechanical ambient conditions
Transport as per EN 60721-3-2
Operation as per EN 60721-3-3
Class 2M2
Class 3M2
12
Siemens
A6V11681604_enUS_b
Smart Infrastructure
2022-05-25
Standards, directives and approvals
EU conformity (CE)
A5W00148475A*)
RCM conformity
A5W00148474A*)
UL
UL 916, http://ul.com/database
Note: The exposed polymeric parts of these
devices have been investigated for use in air
plenums in accordance with Sec.18 of
UL 1995.
Environmental compatibility
The product environmental declaration
A5W00068298A*) contains data on
environmentally compatible product design
and assessments (RoHS compliance,
materials composition, packaging,
environmental benefit, disposal).
*) The documents can be downloaded from Siemens US Download Center.
General data
General
Dimension
See Dimensions [▶15]
Weight
POL224.00
POL224.05
0.64 lbs (288 g)
0.30 lbs (134 g)
Color (POL224.00)
Light grey RAL 7035
13
Siemens
A6V11681604_enUS_b
Smart Infrastructure
2022-05-25
Wiring Guide
Fig. 1: Single Dry-Bulb Switchover + Thermostat + Damper Actuator + OAT & MAT Sensors
K1
Relay 1, DPDT relay, dry contact, digital input 1 for fan high speed with W1 call
K2
Relay 2, SPST relay, dry contact, digital input 2 for fan low speed with Y1 call
K3
Relay 3, SPST relay, dry contact, digital input 3 for fan low speed with G call
K4
Relay 4, DPST relay, dry contact, digital input 4 for fan high speed with Y2 call
14
Siemens
A6V11681604_enUS_b
Smart Infrastructure
2022-05-25
Fig. 2: Single Enthalpy Switchover + VFD + Thermostat + Exhaust Fan + Damper Actuator + OAT &
MAT Sensors + OAH Sensor
15
Siemens
A6V11681604_enUS_b
Smart Infrastructure
2022-05-25
Dimensions (in inch (mm))
POL224.00
POL224.05
Issued by
Siemens Industry, Inc.
Smart Infrastructure
1000 Deerfield Pkwy
Buffalo Grove IL 60089
+1 847-215-1000
© Siemens Industry, Inc., 2022
Technical specifications and availability subject to change without notice.
Document ID
A6V11681604_enUS_b
Edition
2022-05-25

This manual suits for next models

1

Other Siemens Industrial Equipment manuals

Siemens SGT-750 Troubleshooting guide

Siemens

Siemens SGT-750 Troubleshooting guide

Siemens SIRIUS 3RA2711 Technical Document

Siemens

Siemens SIRIUS 3RA2711 Technical Document

Siemens SIMOGEAR BA 2030 Quick guide

Siemens

Siemens SIMOGEAR BA 2030 Quick guide

Siemens SIMATIC S7 300 PLC User manual

Siemens

Siemens SIMATIC S7 300 PLC User manual

Siemens 5SV8101-6KK User manual

Siemens

Siemens 5SV8101-6KK User manual

Siemens SGB2 User manual

Siemens

Siemens SGB2 User manual

Siemens SENTRON VL User manual

Siemens

Siemens SENTRON VL User manual

Siemens Synco-Gamma User guide

Siemens

Siemens Synco-Gamma User guide

Siemens MOBILETT XP User manual

Siemens

Siemens MOBILETT XP User manual

Siemens 3WN6 User manual

Siemens

Siemens 3WN6 User manual

Siemens 3VA9 1 0RL 0 Series User manual

Siemens

Siemens 3VA9 1 0RL 0 Series User manual

Siemens 3VW9011-0AE0 User manual

Siemens

Siemens 3VW9011-0AE0 User manual

Siemens 3VA9 72-0WA00 Series User manual

Siemens

Siemens 3VA9 72-0WA00 Series User manual

Siemens SIMOCODE pro 3UF70 0-1A 00-0 Series User manual

Siemens

Siemens SIMOCODE pro 3UF70 0-1A 00-0 Series User manual

Siemens FDM1101-R Series User manual

Siemens

Siemens FDM1101-R Series User manual

Siemens SINUMERIK ONE NCU 1750 Technical Document

Siemens

Siemens SINUMERIK ONE NCU 1750 Technical Document

Siemens Maxum II User manual

Siemens

Siemens Maxum II User manual

Siemens SIRIUS 3SK1 User manual

Siemens

Siemens SIRIUS 3SK1 User manual

Siemens SIPROTEC 5 Compact Guide

Siemens

Siemens SIPROTEC 5 Compact Guide

Siemens Sivacon S8 User manual

Siemens

Siemens Sivacon S8 User manual

Siemens 8MF1 Series User manual

Siemens

Siemens 8MF1 Series User manual

Siemens SIRIUS ACT 3SU19 User manual

Siemens

Siemens SIRIUS ACT 3SU19 User manual

Siemens SINAMICS S120 Application guide

Siemens

Siemens SINAMICS S120 Application guide

Siemens SIRIUS S00 User manual

Siemens

Siemens SIRIUS S00 User manual

Popular Industrial Equipment manuals by other brands

Henkel LOCTITE UVALOC 1000 operating manual

Henkel

Henkel LOCTITE UVALOC 1000 operating manual

ABB HT612032 Operation manual

ABB

ABB HT612032 Operation manual

Proluxe Doughpro DP2300PRE Operation manual

Proluxe

Proluxe Doughpro DP2300PRE Operation manual

Endress+Hauser Flowphant T ODTT31 operating instructions

Endress+Hauser

Endress+Hauser Flowphant T ODTT31 operating instructions

Eaton Cutler-Hammer TRU-START Operation and installation manual

Eaton

Eaton Cutler-Hammer TRU-START Operation and installation manual

Metallkraft AKM 130-3P operating instructions

Metallkraft

Metallkraft AKM 130-3P operating instructions

D+H VCD-0204-0 50-1-ACB-M Series Original instructions, Connection, Dimensions

D+H

D+H VCD-0204-0 50-1-ACB-M Series Original instructions, Connection, Dimensions

Grizzly T26472Z owner's manual

Grizzly

Grizzly T26472Z owner's manual

ABB TPS52-D Series Operation manual

ABB

ABB TPS52-D Series Operation manual

Dimac J06 installation manual

Dimac

Dimac J06 installation manual

ABB HT604182 Operation manual

ABB

ABB HT604182 Operation manual

HeatWork CliWi HC 300 user manual

HeatWork

HeatWork CliWi HC 300 user manual

Bosch BEA 750 Original instructions

Bosch

Bosch BEA 750 Original instructions

Carlisle BINKS E420 operating manual

Carlisle

Carlisle BINKS E420 operating manual

Samson 3930 Mounting and operating instructions

Samson

Samson 3930 Mounting and operating instructions

GÜDE GDH 330 Original instructions

GÜDE

GÜDE GDH 330 Original instructions

Wilo Yonos GIGA2.0-I Installation and operating instructions

Wilo

Wilo Yonos GIGA2.0-I Installation and operating instructions

Kadee Metal Whisker 451 Assembly instructions

Kadee

Kadee Metal Whisker 451 Assembly instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.