Close the control stop.
Using the supplied collar wrench, remove handle
from flushometer, if applicable.
NOTE: On some flushometers with
a faulty air vent, or recently flushed valve, be
prepared to collect a small amount of water with a
rag or sponge placed under the handle.
Place sleeve assembly with flat notch facing
upwards into collar nut and attach the Side Mount
unit where the handle was removed.
NOTE: Failure to install flat notch correctly can
result in damage to the unit.
Tighten collar nut with supplied collar wrench.
Open the control stop.
NOTE: Save the handle in the event you wish to
return to manual flushometer.
LIMITED WARRANTY
Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material
and workmanship for a period of three (3) years (one (1) year for special finishes, SF faucets, PWT electronics and 30 days for PWT software) from date of first
purchase. During this period, Sloan Valve Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this
warranty under normal use and service. This shall be the sole and exclusive remedy under this warranty. Products must be returned to Sloan Valve Company, at
customer’s cost. No claims will be allowed for labor, transportation or other costs. This warranty extends only to persons or organizations who purchase Sloan Valve
Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF
ANY MEASURE WHATSOEVER.
1 - INSTALLATION (FOR EITHER LEFT- OR RIGHT-HAND)
Optima Plus®Dual-Flush and Single-Flush
Side Mount Unit Installation Instructions
Code No. 9108310
Rev. 6 (08/13)
EBV-500-A
Single-Flush Side Mount
EBV-550-A
Dual-Flush Side Mount

Remove sticker from sensor window.
The Side Mount unit comes with batteries factory installed and will “wake up” when sticker is removed from sensor window. Please
ensure this is the last step in the installation process and unless the target is a permanent fixture in the sensor’s environment (i.e. a wall
or stall door) it must be removed from the view of the sensor. There is a three minute delay to calibration to allow the installer to clear
from the view of the sensor.
The Side Mount unit calibrates to the surrounding environment once sticker is removed (with three minute delay to allow installer to clear
from the view of the sensor). The unit will exhibit an LED flash pattern as follows:
• GREEN and RED LED flash once, GREEN LED flashes 5 times
• 150 seconds of slow GREEN double flashes
• 10 seconds of fast GREEN double flashes
• 12-15 seconds of fast GREEN flashes (calibration)
• 3 slow GREEN LED flashes indicates calibration is done
• Normal Operation with one flush activation
NOTE: For retrofit installation to Sloan GEM•2 flushometer (-G variation).
1. Thread EBV-157 adapter onto valve body.
2. Place EBV-576 GEM•2 gasket on top of sleeve assembly.
3. Mount side mount to valve body and tighten collar nut.
NOTE: For retrofit installation to Zurn flushometer make sure to
re-use the Zurn gasket and place on top of sleeve assembly before
mounting to valve. Contact Sloan Technical Support if the Zurn
gasket is not present or if another is required.
Units are preset at factory in water closet mode.
To change unit from water closet mode to urinal mode, complete the following:
Press and hold the True Mechanical Override (TMO) button for 20-30 seconds.
The unit will exhibit an LED flash pattern as follows:
• For approximately the first 10 seconds there will be no LED flashing.
• For approximately seconds 10-20, both the RED and GREEN LEDs will produce short simultaneous flashes.
• For approximately seconds 20-30, the GREEN LED will flash.
Release the TMO button during the 20-30 seconds when both the RED and GREEN LEDs produce LONG simultaneous flashes and
remove non-permanent items from view of the sensor. The Side Mount unit will now be in urinal mode* and begin calibration. See
Activation.
*Urinal mode provides a shorter sensor range and 1-2 second flush delay.
Press and hold the True Mechanical Override (BLACK) button for 10-20 seconds.
The unit will exhibit an LED flash pattern as follows:
• For approximately the first 10 seconds there will be no LED flashing.
• For approximately seconds 10-20, both the RED and GREEN LEDs will produce short simultaneous flashes.
Release the TMO button during the 10-20 seconds when both the RED and GREEN LEDs produce SHORT simultaneous flashes. The unit
will now ignore targets for 10 minutes to enable the toilet or urinal to be cleaned or serviced. Unit will resume normal operation after 10
minutes or if either button is pushed. Green button will generate a reduced flush and then resume normal operation, black button will
provide a full flush before resuming normal operation.
2 - ACTIVATION
1 - INSTALLATION (FOR EITHER LEFT- OR RIGHT-HAND) - CONTINUED
MODE CHANGE (SINGLE-FLUSH UNITS ONLY)
SERVICE MODE - DUAL-FLUSH AND SINGLE FLUSH UNITS
EBV-576
EBV-157

Using supplied battery compartment hex wrench, remove battery
compartment from the Side Mount unit.
Remove batteries from compartment tray.
Install 4 new C-cell batteries into compartment tray (note position of
batteries in tray), and reinstall compartment tray into the Side Mount
unit.
The Side Mount unit comes preset from the factory. If special
circumstances require adjustment of the activation distance, please
contact Sloan.
The Side Mount unit calibrates upon power up, GREEN and RED
LEDs flash once. The unit will actuate a flush followed by 5 flashes
of GREEN LED. The unit will then perform calibration, a 20 second
sequence, where the GREEN LED flashes quickly. Finally the unit
will start normal operation.
Manual flush button on Side Mount unit allows manual activation
when desired.
DO NOT USE abrasive or chemical cleaners (including chlorine bleach) to clean side mount unit or flushometer that may
dull the luster and attack the finish. Use ONLY mild soap and water, then wipe dry with clean cloth or towel.
While cleaning the bathroom tile, protect the side mount unit from any splattering of cleaner. Acids and cleaning fluids will
discolor or remove chrome plating.
DO NOT USE abrasive or chemical cleaners (including chlorine bleach) to clean sensor window that may distort or ruin
the sensor.
1. RED LED continuously flashes when target is present.
The battery is low. Refer to battery replacement instructions.
2. RED LED flashes 4 times after a target has been present for 8 seconds. RED LED flashes once when a target is not present.
The battery is low. Refer to battery replacement instructions.
3. RED LED flashes continuously after calibration.
The unit has failed to calibrate. The optics window is obscured. Remove power, clean window and remove any objects
(barrels, toolboxes, etc.) within close proximity of unit.
Repeat power-up sequence. If unit fails, consult Sloan Technical Support.
When assistance is required, please contact Sloan Technical Support at:
1-888-SLOAN-14 (1-888-756-2614)
- -
++
--
+ +
TOP VIEW
- - ++
--
+ +
TOP VIEW
BATTERY REPLACEMENT
TROUBLESHOOTING
CARE AND CLEANING

AIR DELIGHTS, INC. • 11170 SW 5TH ST. #100 • BEAVERTON, OR 97005
Phone: 1-800-440-5556 or 503-352-1201 • Fax: 1-866-243-5689 • www.airdelights.com
© 2013 SLOAN VALVE COMPANY Code No. 9108310 – Rev. 6 (08/13)
EBV-550-A
DUAL-FLUSH
SIDE MOUNT
BATTERY COMPARTMENT
HEX WRENCH
EBV-545
COLLAR WRENCH
4 C-CELL BATTERIES (FACTORY INSTALLED)
EBV-1014-A BATTERY TRAY ASSEMBLY
WES-46 WALL PLATE
EBV-576 GASKET
(FOR -G VARIATION ONLY)
EBV-157 ADAPTER
(FOR -G VARIATION ONLY)
EBV-505-A
SLEEVE ASSEMBLY
EBV-570-A
SLEEVE ASSEMBLY
EBV-500-A
SINGLE-FLUSH
SIDE MOUNT
PARTS LIST
Manufactured in China by Sloan Valve Company.
US Patents Patent Pending. OPTIMA PLUS®
The information contained in this document is subject to change without notice.
This manual suits for next models
1
Other Sloan Control Unit manuals

Sloan
Sloan G2 Optima Plus Operating manual

Sloan
Sloan Optima ETF-80 User manual

Sloan
Sloan TRUFLUSH TRF 8900-CP User manual

Sloan
Sloan NAVAL 110 User manual

Sloan
Sloan SOLIS 8100 Series User manual

Sloan
Sloan 152 ES-S TMO SWB User manual

Sloan
Sloan 152 ES-S TMO SWB User manual

Sloan
Sloan G2 Optima Plus Operating manual