Manual Override Operation
If the manual override is manipulated, since any connected
equipment will be activated, make sure to be done only after no
danger is confirmed.
Non-locking push type (Tool required)
Locking type (Tool required)
<
Option
>
Push-locking type (Tool required)
<
Latching type
>
Note) Ensure the locking type manual override is unlocked before
using.
Attaching and detaching connectors
앬To attach a connector, hold the lever and connector unit
between your fingers and insert straight onto the pins of the
solenoid valve so that the lever’s pawl is pushed into the
groove and locks.
앬To detach a connector, remove the pawl from the groove by
pushing the lever downward with your thumb, and pull the
connector straight out.
Note) GENTLY pull the lead wire, otherwise it may cause contact failure or
disconnection.
Crimping of lead wires and sockets
Peel 3.2 to 3.7 mm of the tip of lead wire, enter the core wires
neatly into a socket and crimp it with a special crimp tool. Be
careful so that the cover of lead wire does not enter into the
crimping part. (Crimping tool part no.: DXT170-75-1)
Lead wire 0.2 to 0.33 mm2
(Max. cover diameter: ø1.7 mm)
Socket
Crimping area
Core wire
crimping area
Hook Insulation
Core wire
Attaching and detaching lead wires with sockets
앬Attaching
Insert the sockets into the square holes of the connector (with
A, C, and B indication) and continue to push the sockets all the
way in until the lock by hooking into the seats in the connector.
(When they are pushed in, their hooks open and they are
locked automatically.) Then confirm that they are locked by
pulling lightly on the lead wires.
앬Detaching
Pull and detach the lead wire, pressing in on the end of the
hook of the socket through the side hole using a stick with thin
end (about 1 mm). To reuse the socket, extend the hook
outward.
Connector
Lead wire
Socket
Hook
When operating the lock with the driver, use a watchmakers’
screwdriver and turn lightly.
[Torque 0.1 N·m or less]
Caution
Lead wire
Socket
Part no. DXT170-71-1
0.2 to 0.33 mm2
(Max. cover diameter: ø1.7 mm)
Cover
Pin
Convex
part
Convex
part
Pin Connector
Part no. AXT661-12
Lever
Hook
ON
TURN PUSH
01
OFF
TURN
01
Set
TURN PUSH
01
Reset
TURN PUSH
01
Be sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page 4-18-2.
•It is turned ON by pushing the button in the
direction indicated by the arrow until it hits the
end and is turned OFF by releasing the button.
•If the manual override is turned clockwise and
the mark is adjusted to 1, it will be locked in
the ON state.
•If the manual override is turned,
counterclockwise and mark is adjusted to 0,
locking will be released and the manual
override will return.
•If the manual override is turned clockwise and
the mark is adjusted to 1, it will be backed to
the reset condition. (Passage P A)
•If the manual override is turned
counterclockwise and the mark is adjusted
to 0, it will be back to the reset condition.
(Passage A R) (Reset state at the time of
shipment.)
Warning
How to Use Plug Connector
Caution
Precautions