- 4 -
VP4*50*-OMC0001-B
Warning
Design / Selection
1. Confirm the specification
Products represented in this manual are designed only for use in
compressed air systems (including vacuum).
Do not operate at pressures or temperatures, etc., beyond the
range of specifications, as this can cause damage or malfunction.
(Refer to the specifications.)
Please contact SMC when using a fluid other than compressed
air (including vacuum).
We do not guarantee against any damage if the product is used
outside of the specification range.
2. Actuator drive
When an actuator, such as a cylinder, is to be driven using a
valve, take appropriate measures (cover installation or approach
prohibition) to prevent potential danger caused by actuator
operation.
3. Intermediate stopping
For 3-position closed center type, it is difficult to make a piston
stop at the required position accurately due to the compressibility
of air. Furthermore, since valves and cylinders are not
guaranteed for zero air leakage, it may not be possible to hold a
stopped position for an extended period of time. Please contact
SMC if it is necessary to hold a stopped position for an extended
period of time.
Refer to Specific Product Precautions for VP4350 Handling
Precautions.
4. Effect of back pressure when using a manifold
Use caution when valves are used on a manifold, because an
actuator may malfunction due to back-pressure. For 3-position
exhaust center valve or single acting cylinder, take appropriate
measures to prevent the malfunction by using it with an individual
exhaust manifold.
5. Holding of pressure
Since the valves are subject to air leakage, they cannot be used
for applications such as holding pressure in a pressure vessel.
6.
Not suitable for use as an emergency shut-off
valve, etc.
VP4*50, 4*70, VVP4*0 series are not designed for safety
applications such as an emergency shutoff valve. If the valves
are used for the mentioned applications, additional safety
measures should be adopted.
7. Release of residual pressure
For maintenance purposes install a system for releasing residual
pressure. Especially in the case of 3-position closed center valve,
ensure that the residual pressure between the valve and the
cylinder is released.
8. Double pilot type
When using the double pilot type for the first time, actuators may
travel in an unexpected direction depending on the switching
position of the valve. Implement measures to prevent any danger
from occurring when operation the actuator.
9. Ventilation
Provide ventilation when using a valve in a confined area, such
as in a closed control panel. For example, install a ventilation
opening, etc. in order to prevent pressure from increasing inside
of the confined area and to release the heat generated by the
valve.
10. Extended periods of continuous energization
If a valve will be continuously energized for an extended period of
time, the temperature of the valve will increase due to the heat
generated by the coil.
For applications such as mounting a valve on a control panel,
incorporate measure to limit the heat radiation so that it is within
the operating temperature range.
11.
Do not disassemble the product of make any
modifications, including additional machining.
It may cause human injury and/or an accident.
1. Momentary energization
If a double solenoid valve is operated with momentary energization,
it should be energized for at least 0.1 second. However,
depending on the condition of the secondary load, it should be
energized until the cylinder reaches the stroke end position,
since there is a possibility of malfunction.
2. Leakage voltage
Take note that the leakage voltage will increase when a resistor
is used in parallel with switching element or a C-R circuit (surge
voltage suppressor) is used for protecting a switching device
because of the passing leakage voltage through the CR circuit.
The suppressor residual leakage voltage should be
as follows.
DC coil 5% or less of rated voltage
AC coil 15% or less of rated voltage
3. Solenoid valve drive for AC with a solid state
output (SSR, TRIAC output,
etc.)
1) Current leakage
When using a snubber circuit (C-R element) for surge
protection of the output, a very small amount of electrical
current will continue to flow even during the OFF state. This
results in the valve not returning. In a situation where the
tolerance is exceeded, as in the above case, take measures to
install a bleeder resistor.
2) Minimum allowable load amount (Min. load current)
When the consumption current of a valve is less than the
output’s minimum allowable load volume or the margin is small,
the output may not switch normally. Please contact SMC.
4. Surge voltage suppressor
If
a surge protection circuit contains nonstandard diodes, such as
Zener diodes or varistor, a residual voltage that is in proportion to
the protective circuit and the rated voltage will remain.
Therefore, take into consideration the surge voltage protection of
the controller. In the case of diodes, the residual voltage is
approximately 1 V.
VP4*
**
*50/VP4*
**
*70/VVP4*
**
*0 Series
Precautions for 5 Port Air Operated Valve 1
11