S
SS0750 SDQ08 C4 N B
Voltage: 24 VDC
S07 1 0 5
Base mounted plug-in
Note) Not compatible with dual 3 port valves.
Refer to pages 1664 to 1679 for the details
of EX250 integrated type (for I/O) serial
transmission system.
S0700
Kit (Serial Transmission)
EX250 Integrated Type (For I/O) Serial Transmission System
How to Order Manifold
Cylinder port size
Symbol
C2
C3
C4
CM
N1
N3
NM
Port size
Metric
Inch
With one-touch fitting for ø2
With one-touch fitting for ø3.2
With one-touch fitting for ø4
Mixed size/with port plug Note)
With one-touch fitting for ø1/8"
With one-touch fitting for ø5/32"
Mixed size/with port plug Note)
Stations
Symbol
01
24
Stations
1 station
24 stations
Note) The maximum number of stations will be different
depending on the wiring specification.
···
···
Note)
Note) Specify “Mixed size/with port plug” in the mani-
fold specification sheet.
Symbol
Nil
0
1
8
Specification
SI unit/Input block: None (SD0)
Input block: None
Input block 1 pc.
Input block 8 pcs.
Input block
(for I/O unit only)
Note) Without SI unit (SD0), the symbol is nil.
Symbol
Nil
1
2
3
Specification
Input block: None
M12 2 inputs
M12 4 inputs
M8 4 inputs (3 pins)
Input block type
(for I/O unit only)
Note) Without SI unit (SD0), the symbol is nil.
···
···
Symbol
Nil
N
Specification
PNP sensor input (+COM) or without input block
NPN sensor input (–COM)
Input block COM
(for I/O unit only)
Note) Without SI unit (SD0), the symbol is nil.
Option
B
Note 2)
D
D0
D
Note 3)
K
Note 4)
N
R
Note 5)
S
Option
None
With back pressure check valve
(all stations)
With DIN rail (Rail length: Standard)
Without DIN rail (with bracket)
With DIN rail Designated length
(: station)
Special wiring specification (Except
double wiring)
With name plate
External pilot
Built-in silencer
Note 1) When two or more options are specified,
indicate them alphabetically. Example) -BRS
Note 2) When installing a back pressure check valve
on the required station, enter the part number
and specify the station position in the manifold
specification sheet.
Note 3) The available number of stations is larger than
the number of manifold stations.
Note 4) Indicate the wiring specification for mixed
single and double wirings.
Note 5) For details, refer to page 648.
∗
For manifold optional parts, refer to pages 648 to
652.
∗
For manifold exploded view, refer to page 654.
Symbol
Nil
Kit name
For I/O
serial
transmission
S kit
Kit name SpecificationSymbol
Without serial unit
DeviceNet
PROFIBUS DP
CC-Link
CANopen
ControlNet
EtherNet/IP
AS-Interface 31SLAVE 8 IN/8 OUT 2 power supply systems
AS-Interface 31SLAVE 4 IN/4 OUT 2 power supply systems
AS-Interface 31SLAVE 8 IN/8 OUT 1 power supply system
AS-Interface 31SLAVE 4 IN/4 OUT 1 power supply system
Standard
station
1 to 12
stations
Max. number of
stations for special
wiring specification
24
stations
Max. number
of solenoids
24
1 to 4 stations
1 to 2 stations
1 to 4 stations
1 to 2 stations
8
4
8
4
8
4
8
4
SD0
SDQ
SDN
SDV
SDY
SDZCN
SDZEN
SDTA
SDTB
SDTC
SDTD
Note 1) The maximum number of stations is determined by the total number of solenoids.
For mixed single and double wirings, enter “-K” to the order code options.
Note 2) For SI unit part number, refer to page 655.
SI unit COM.
Note) Without SI unit (SD0), the symbol is nil.
SI unit COM.
+COM.
–COM.
N
EX250
Nil
DeviceNet
—
PROFIBUS DP
—
CC-Link
—
AS-Interface
—
CANopen
—
ControlNet
—
EtherNet/IP
—
Single type
1
Double, Dual 3 port type
2
Type of actuation
Number of solenoids
Note 2)
SS0750-08C4SDQN13N
·····
∗S0710-5 ····················
∗S0720-5 ····················
∗S07A0-5 ····················
∗SS0700-10A-1 ··········
1 set – Manifold base part no.
3 sets – Valve part no. (Stations 1 to 3)
2 sets – Valve part no. (Stations 4 to 5)
2 sets – Valve part no. (Stations 6 to 7)
1 set – Blanking plate part no. (Station 8)
How to Order Manifold Assembly
<Example>
Serial transmission kit
Specify the part numbers for valves and
options together beneath the manifold base
part number.
Prefix the asterisk to
the part nos. of the
solenoid valve, etc.
Write sequentially from the
1st station on the D side.
When part nos. written
collectively are complicated,
specified by using the
manifold specification sheet.
1 2 3 ······ S
tations
Dside Uside
How to Order Valves
Type of actuation
Note) For JIS symbol, refer to page 616.
Symbol
1
2
A
B
C
Specification
2 position single
2 position double
4 position dual 3 port type (N.C. + N.O.)
4 position dual 3 port type (N.O. + N.O.)
[Pressure center]
4 position dual 3 port type (N.C. + N.C.)
[Exhaust center]
Specification
Standard
External pilot Note)
Symbol
Nil
R
Function
620
P0609-P0680-E080904.qxd 08.9.4 11:34 AM Page 620