SMC Networks SV Series User manual

Serial wiring
with input/output
unit
EX250
SV1000
2000
3000
DeviceNetTM
PROFIBUS-DP
CC-Link
AS-i
CANopen
ControlNetTM
EtherNet/IPTM
Applicable protocol
Applicable
manifold
Series
VQC1000
2000
4000
DeviceNetTM is a trademark of ODVA.
ControlNetTM is a trademark of ControlNet International.
EtherNet/IPTM is a trademark used under license by ODVA.
Information
Serial Wiring with Input/Output Unit
5 Port Solenoid Valve for EX250
Series SV/VQC
쎲Compatible with DHCP
쎲Communication speed: 10 M/100 Mbps
쎲Able to HOLD/CLEAR the output in case of
an error occurrence.
EtherNet/IP™compatible products
are now available.
Series SV
Series VQC
Akihabara UDX 15F,
4-14-1, Sotokanda, Chiyoda-ku,
Tokyo 101-0021, JAPAN
URL http://www.smcworld.com
©2006 SMC Corporation
All Rights Reserved
06-E532 Issued: September, 2006
D-DNP P-120 (DN)
1

W 10S1
1
2
3
SV1000
SV2000
SV3000
Series
Stations
Note
Double wiring
specification Note 1)
Specified layout Note 2)
(Up to 32
solenoids possible.)
Symbol
02
16
02
20
No. of stations
2 stations
16 stations
2 stations
20 stations
• When an AS-i compatible SI unit is used, the
maximum numbers of solenoids are as follows:
8in/8out specification: Maximum 8 solenoids
4in/4out specification: Maximum 4 solenoids
Note 1) Double wiring specifica-
tion: Single, double, 3
position and 4 position
solenoid valves can be
used on all manifold
stations.
Use of a single solenoid will result
in an unused control
signal. If this is not
desired, order with a
specified layout.
Note 2) Specified layout: Indicate
wiring specification in the
manifold specification
sheet. (Note that double, 3
position and 4 position valves
cannot be used where
single solenoid wiring has
been specified.)
쎲Tie-rod Base
SS5V D1
Input block common
specification
+COM. or without input block
–COM.
Nil
N
A, B port size (Inch)
A, B port
Symbol
N1
N3
N7
N3
N7
N9
N7
N9
N11
M
With one-touch fitting for ø1/8"
With one-touch fitting for ø5/32"
With one-touch fitting for ø1/4"
With one-touch fitting for ø5/32"
With one-touch fitting for ø1/4"
With one-touch fitting for ø5/16"
With one-touch fitting for ø1/4"
With one-touch fitting for ø5/16"
With one-touch fitting for ø3/8"
A, B ports mixed
With one-touch
fitting for
ø5/16"
P, E port
Applicable series
SV1000
SV2000
SV3000
With one-touch
fitting for
ø3/8"
With one-touch
fitting for
ø3/8"
A, B port size (Metric)
A, B port
Symbol
C3
C4
C6
C4
C6
C8
C6
C8
C10
M
With one-touch fitting for ø3.2
With one-touch fitting for ø4
With one-touch fitting for ø6
With one-touch fitting for ø4
With one-touch fitting for ø6
With one-touch fitting for ø8
With one-touch fitting for ø6
With one-touch fitting for ø8
With one-touch fitting for ø10
A, B ports mixed
With one-touch
fitting for
ø8
P, E port
Applicable series
SV1000
SV2000
SV3000
With one-touch
fitting for
ø10
With one-touch
fitting for
ø12
SI unit
DeviceNet
PROFIBUS-DP
CC-Link
AS-i 8in/8out 31Slave Mode , 2 power supply systems
AS-i 4in/4out 31Slave Mode , 2 power supply systems
AS-i 8in/8out 31Slave Mode, 1 power supply system
AS-i 4in/4out 31Slave Mode, 1 power supply system
CANopen
ControlNet (IP40)
EtherNet/IP
Without SI unit, Without end plate
QW
NW
VW
TAW
TBW
TCW
TDW
YW
ZCN
ZEN
0
• Input blocks cannot be mounted without SI unit.
• When the DIN rail is included without an SI unit, the DIN rail length will
accommodate an SI unit and one input block.
Note 1) There is a limit on the current supplied from an SI unit of AS-i
compatible 1 power supply system specification to an input block or
valve. For details, refer to page 13.
Note 2) IP40 when the SI unit spec is only compatible with ControlNet.
(Manifold model no. is “SS5V쏔-10S1ZCN쏔쏔쏔D”.)
Note 3) For SI unit part no., refer to page 3.
∗In the case of mixed specification (M), indicate separately in the manifold specification sheet.
∗Port sizes of X, PE port for external pilot specification (R, RS) are ø4 (metric), ø5/32" (inch) for the SV1000/2000 series and ø6
(metric) and ø1/4" (inch) for the SV3000 series.
Input block stations
None
1 station
8 stations
Nil
1
8
Note) Without SI unit, the
symbol is nil.
When an AS-i compatible
S kit is used, there is
a limit on the
maximum number of
stations. For details,
please refer to page
13.
How to Order
EX250 Serial Wiring
With Input/Output Unit
Series SV
05 U
P, E port position
U
D
B
U side (2 to 10 stations)
D side (2 to 10 stations)
Both sides (2 to 20 stations)
3 stations
20 stations
When a longer DIN rail is
desired than the specified
stations.
(Specify a longer rail than
the standard length.)
Mounting
Nil
D
D0 Note)
D3
D20
Note) In the case of D0, only DIN rail
brackets are attached.
SUP/EXH block assembly specification
Internal pilot
Internal pilot, Built-in silencer
External pilot
External pilot, Built-in silencer
Nil
SNote)
R
RS Note)
Note) When the built-in silencer type is used,
keep the exhaust port from coming in
direct contact with water or other liquids.
Enclosure
IP67 specification
QW
Without input block
M12 2 inputs
M12 4 inputs
M8 4 inputs
Input block type
Nil
1
2
3
Note) Without SI
unit, the
symbol is nil.
For details about certified products conforming to
international standards, visit us at www.smcworld.com.
Direct mounting
DIN rail mounting (with DIN rail)
DIN rail mounting (without DIN rail)
...
...
...
...
...
...
...
...
2

How to Order Valve Manifold Assembly (Example)
Example (SV1000)
Manifold
SS5V1-W10S1QW11ND-05B-C6 (1 set)
Double solenoid
SV1200-5FU (3 sets)
Single solenoid
SV1100-5FU (2 sets)
Input block
(M12: 2 inputs, 1 station)
321
Stations
SS5V1-W10S1QW11ND-05B-C6 ......... 1 set (Manifold base part no.)
∗ SV1100-5FU ......... 2 sets (Single solenoid part no.)
∗ SV1200-5FU ......... 2 sets (Double solenoid part no.)
SV 1 0 0 F5
Rated voltage
524 VDC
1
How to Order Solenoid Valves
Pilot
∗External pilot specification
is not applicable for 4
position dual 3 port valves.
Internal pilot
External pilot
Nil
RBack pressure check valve
∗Built-in back pressure
check valve type is
applicable to the SV1000
series only.
None
Built-in
Nil
K
Note)
• For solenoid valve specifications and dimensions, refer to the SV series in
the “Best Pneumatics 2004 Vol. 1” catalog.
• For SI unit dimensions, refer to page 12.
• For details on the SI unit, refer to the separate technical instruction manual.
Series
1
2
3
SV1000
SV2000
SV3000
Type of actuation
1
2
3
4
5
A
B
C
2 position single solenoid
2 position double solenoid
3 position closed center
3 position exhaust center
3 position pressure center
4 position dual 3 port valve: N.C./N.C.
4 position dual 3 port valve: N.O./N.O.
4 position dual 3 port valve: N.C./N.O.
∗4 position dual 3 port valves are applicable to the
SV1000 and SV2000 series only.
Light/surge voltage suppressor
With light/surge voltage suppressor
With surge voltage suppressor
U
R
Note) Available with manifold block
for station additions. Refer to
“Best Pneumatics 2004 Vol. 1”
catalog.
Manual override
Nil: Non-locking push
type
D: Push-turn locking
slotted type
QW
NW
VW
YW
ZCN
Symbol Protocol type
DeviceNet
PROFIBUS-DP
CC-Link
CANopen
ControlNet
EX250-SDN1
EX250-SPR1
EX250-SMJ2
EX250-SCA1
EX250-SCN1
SI unit part no.
SI Unit Part No.
TAW
TBW
TCW
TDW
ZEN
Symbol Protocol type
AS-i 8in/8out 31Slave Mode, 2 power supply systems
AS-i 4in/4out 31Slave Mode, 2 power supply systems
AS-i 8in/8out 31Slave Mode, 1 power supply system
AS-i 4in/4out 31Slave Mode, 1 power supply system
EtherNet/IP
EX250-SAS3
EX250-SAS5
EX250-SAS7
EX250-SAS9
EX250-SEN1
SI unit part no.
End plate
SI Unit Part No.
D side
U side
3
EX250 Serial Wiring with Input/Output Unit Series SV

01 1 station
The maximum number of
stations differs depending
on the kits.
B5
LM
C3
C4
C6
M5
CM
L3
L4
L6
L5
B3
B4
B6
With one-touch fitting for ø3.2
With one-touch fitting for ø4
With one-touch fitting for ø6
M5 thread
Mixed size/with port plug
Elbow top ported with one-
touch fitting for ø3.2
Elbow top ported with one-
touch fitting for ø4
Elbow top ported with one-
touch fitting for ø6
Elbow bottom ported with
one-touch fitting for ø3.2
Elbow bottom ported with
one-touch fitting for ø4
Elbow bottom ported with
one-touch fitting for ø6
M5 thread
Mixed size for elbow piping
M5 thread
Nil
B
D
D쏔
K
N
R
S
Note 1) When two or more options are specified, indicate
them alphabetically.
Example) -BRS
Note 2) When installing a back pressure check valve on the
required station, enter the part number and specify
the station position in the manifold specification
sheet.
Note 3) For special DIN rail length, indicate “D쏔”. (Enter the
number of stations inside 쏔.)
Example: -D08
In this case, stations will be mounted on a DIN rail for 8
stations regardless of the actual number of manifold
stations.
The specified number of stations must be larger than the
number of stations on the manifold.
Indicate “D0” for the option without DIN rail.
Note 4) Be sure to indicate the wiring specification in the
specification sheet.
Note 5) For external pilot option, “-R”, indicate the external
pilot specification “R” for the applicable valves as
well.
Note 6) The built-in silencer type does not satisfy the IP67
standard.
Nil PNP or without input block
NPN
N
Nil
1
2
3
Nil
0
1
8
1VQC1000
Series
Manifold
Stations
08 SDQ
VV5QC 1 1C6
Option
Input block COM.
Kit name
(For details on kits, refer to the next page.)
Number of input blocks
Input block type
Cylinder port size
SKit
B
Nil
SI unit COM.
+COM.
–COM.
N
SI unit COM.
Note) When an AS-i compatible S kit is
used, there is a limit on the
maximum number of stations.
For details, please refer to page 13.
1Plug-in manifold
Note 1) Indicate the size in the specification
sheet in the case of “CM” and “LM”.
Note 2) Symbols for inch sizes are as
follows:
• N1: ø1/8"
• N3: ø5/32"
• N7: ø1/4"
• NM: Mixed
The top ported elbow is LN쏔and the bottom
ported elbow is BN쏔.
None
With back pressure check valve (all stations) Note 2)
With DIN rail (Rail length: Standard)
With DIN rail (Rail length: Special) Note 3)
Special wiring specification (Except double wiring)
Note 4)
With name plate
External pilot Note 5)
Built-in silencer, Direct exhaust Note 6)
Without input block
M12 2 inputs
M12 4 inputs
M8 4 inputs
Without SI unit
Without input block
With 1-input block
With 8-input block
Note) Without SI unit, the symbol is nil.
DeviceNet PROFIBUS-DP CC-Link AS-i CANopen EtherNet/IPControlNet
EX250
Plug-in Manifold
Series VQC1000
Base Mounted
For details about certified products conforming to
international standards, visit us at www.smcworld.com.
How to Order Manifold
...
...
...
...
4

VQC 1 05
0
Series
1VQC1000
1
Seal
Metal seal
Rubber seal
0
1
Rated voltage
524 VDC
Function
Note 1) Metal seal type only.
Note 2) When two or more symbols are
specified, indicate them
alphabetically.
Note 3) It is not applicable to dual 3 port
valves.
Note 4) Use a low wattage type for
continuous energization (when
the totaled energized time per
day is longer than the
non-energized time.)
Standard (1 W)
High-pressure type (1.0 MPa)
Negative COM.
External pilot
Low-wattage type (0.5 W)
Nil
KNote 1)
N
RNote 3)
YNote 4)
With/Without light/surge
voltage suppressor
Ye s
Nil
Manual override
Nil: Non-locking
push type
(Tool required)
B: Locking type
(Tool required)
C: Locking type
(Manual)
D: Slide locking type
(Manual)
Type of actuation
2 position single
2 position double (Metal)
2 position double (Rubber)
3 position closed center
3 position exhaust center
3 position pressure center
1
4 position dual 3 port valve
(A)
4 position dual 3 port valve
(B)
4 position dual 3 port valve
(C)
ANote)
BNote)
CNote)
2
3
4
5
AB
PEBEA
AB
EA P EB
AB
P
EA EB
AB
EBPEA
1
53
42
N.C N.C
1
53
42
N.O N.O
1
53
42
N.C N.O
AB
PEA EB
AB
PEA EB
Note) Rubber seal type only.
Note) There is a limit on the current supplied from an SI unit of the SDTC or SDTD specification to an input block or valve. For details, refer to page 13.
• IP40 for the S kit only, which is compatible with ControlNet. (The other S kits are competible with IP67 ratings.)
Kit name
SD0
SDQ
SDN
SDV
SDTA
SDTB
SDTC Note)
SDTD Note)
SDY
SDZCN
SDZEN
Without SI unit, Without end plate
DeviceNet
PROFIBUS-DP
CC-Link
AS-i 8in/8out 31Slave Mode, 2 power supply systems
AS-i 4in/4out 31Slave Mode, 2 power supply systems
AS-i 8in/8out 31Slave Mode, 1 power supply system
AS-i 4in/4out 31Slave Mode, 1 power supply system
CANopen
ControlNet (IP40)
EtherNet/IP
EX250-SDN1
EX250-SPR1
EX250-SMJ2
EX250-SAS3
EX250-SAS5
EX250-SAS7
EX250-SAS9
EX250-SCA1
EX250-SCN1
EX250-SEN1
—
1 to 12 stations
(24 stations)
1 to 12 stations
(24 stations)
1 to 4 stations (8 stations)
1 to 2 stations (4 stations)
1 to 4 stations (8 stations)
1 to 2 stations (4 stations)
Symbol Protocol type No. of stations SI unit part no.
SKit
(Serial transmission kit for I/O)
IP67
IP40
SI unit: EX250
SI unit
Input block
End plate
• For solenoid valve specifications and dimensions, refer to the VQC series in the “Best Pneumatics 2004 Vol. 2” catalog.
• For SI unit dimensions, refer to page 12.
• For details on the SI unit, refer to the separate technical instruction manual.
How to Order Valves
5
Plug-in Manifold Series VQC

C4
C6
C8
CM
L4
L6
L8
B4
B6
B8
LM
With one-touch fitting for ø4
With one-touch fitting for ø6
With one-touch fitting for ø8
Mixed size/with port plug
Elbow top ported with one-
touch fitting for ø4
Elbow top ported with one-
touch fitting for ø6
Elbow top ported with one-
touch fitting for ø8
Elbow bottom ported with
one-touch fitting for ø4
Elbow bottom ported with
one-touch fitting for ø6
Elbow bottom ported with
one-touch fitting for ø8
Mixed size for elbow piping
08
VV5QC 2 1 C6 SDQ
Kit name
(For details on kits, refer to the next page.)
Cylinder port size
SKit
B
2VQC2000
Series
Manifold
1Plug-in manifold
01 1 station
The maximum number of
stations differs depending
on the kits.
Stations
Note 1) Indicate the size in the specification
sheet in the case of “CM” and “LM”.
Note 2) Symbols for inch sizes are as follows:
• N3: ø5/32"
• N7: ø1/4"
• N9: ø5/16"
• NM: Mixed
The top ported elbow is LN쏔and the bottom
ported elbow is BN쏔.
Nil
0
1
8
Number of input blocks
Note) When an AS-i compatible S kit is used, there
is a limit on the maximum number of stations.
For details, please refer to page 13.
Without SI unit
Without input block
With 1-input block
With 8-input block
Nil
1
2
3
Input block type
Without input block
M12 2 inputs
M12 4 inputs
M8 4 inputs
Nil PNP or without input block
NPN
N
Input block COM.
B
D
D쏔
K
N
R
S
T
Nil
Note 1) When two or more options are specified, indicate them
alphabetically.
Example) -BRS
Note 2) When installing a back pressure check valve on the
required station, enter the part number and specify the
station position in the manifold specification sheet.
Note 3) For special DIN rail length, indicate “D쏔”. (Enter the
number of stations inside 쏔.)
Example: -D08
In this case, stations will be mounted on a DIN rail for 8
stations regardless of the actual number of manifold
stations.
The specified number of stations must be larger than the
number of stations on the manifold.
Indicate “D0” for the option without DIN rail.
Note 4) Be sure to indicate the wiring specification in the
specification sheet.
Note 5) For external pilot option, “-R”, indicate the external
pilot specification “R” for the applicable valves as well.
Note 6) The built-in silencer type does not satisfy the IP67
standard.
Note 7) The SUP and EXH ports on U side are branched
(toward the cylinder port and coil) with ø12 one-touch
fittings for connection.
Option
None
With back pressure check valve (all stations) Note 2)
With DIN rail (Rail length: Standard)
With DIN rail (Rail length: Special) Note 3)
Special wiring specification (Except double wiring)
Note 4)
With name plate
External pilot Note 5)
Built-in silencer, Direct exhaust Note 6)
P, R port on U side, branched type Note 7)
Note) Without SI unit, the symbol is nil.
Nil
SI unit COM.
+COM.
–COM.
N
SI unit COM.
DeviceNet PROFIBUS-DP CC-Link AS-i CANopen EtherNet/IPControlNet
EX250
Plug-in Manifold
Series VQC2000
Base Mounted
For details about certified products conforming to
international standards, visit us at www.smcworld.com.
How to Order Manifold
...
...
...
...
6

Type of actuation
VQC 2 05
0
Manual override
Nil: Non-locking
push type
(Tool required)
B: Locking type
(Tool required)
C: Locking type
(Manual)
D: Slide locking type
(Manual)
Series
2VQC2000
1
2 position single
2 position double (Metal)
2 position double (Rubber)
3 position closed center
3 position exhaust center
3 position pressure center
1
4 position dual 3 port valve
(A)
4 position dual 3 port valve
(B)
4 position dual 3 port valve
(C)
ANote)
BNote)
CNote)
2
3
4
5
AB
PEBEA
AB
EA P EB
AB
P
EA EB
AB
EBPEA
AB
PEA EB
AB
PEA EB
Note) Rubber seal type only.
1
53
42
N.C N.C
1
53
42
N.O N.O
1
53
42
N.C N.O
Seal
Metal seal
Rubber seal
0
1
Rated voltage
524 VDC
Function
Standard (1 W)
High-pressure type (1.0 MPa)
Negative COM.
External pilot
Low-wattage type (0.5 W)
Nil
KNote 1)
N
RNote 3)
YNote 4)
With/Without light/surge
voltage suppressor
Yes
Nil
Note) There is a limit on the current supplied from an SI unit of the SDTC or SDTD specification to an input block or valve. For details, refer to page 13.
• IP40 for the S kit only, which is compatible with ControlNet. (The other S kits are competible with IP67 ratings.)
SKit
(Serial transmission kit for I/O)
Kit name
IP67
IP40
SI unit: EX250
SI unit
Input block
End plate
SD0
SDQ
SDN
SDV
SDTA
SDTB
SDTC Note)
SDTD Note)
SDY
SDZCN
SDZEN
Without SI unit, Without end plate
DeviceNet
PROFIBUS-DP
CC-Link
AS-i 8in/8out 31Slave Mode, 2 power supply systems
AS-i 4in/4out 31Slave Mode, 2 power supply systems
AS-i 8in/8out 31Slave Mode, 1 power supply system
AS-i 4in/4out 31Slave Mode, 1 power supply system
CANopen
ControlNet (IP40)
EtherNet/IP
1 to 4 stations (8 stations)
1 to 2 stations (4 stations)
1 to 4 stations (8 stations)
1 to 2 stations (4 stations)
1 to 12 stations
(24 stations)
1 to 12 stations
(24 stations)
EX250-SDN1
EX250-SPR1
EX250-SMJ2
EX250-SAS3
EX250-SAS5
EX250-SAS7
EX250-SAS9
EX250-SCA1
EX250-SCN1
EX250-SEN1
—
Symbol Protocol type No. of stations SI unit part no.
How to Order Valves
Note 1) Metal seal type only.
Note 2) When two or more symbols are
specified, indicate them
alphabetically.
Note 3) It is not applicable to dual 3 port
valves.
Note 4) Use a low wattage type for
continuous energization (when
the totaled energized time per
day is longer than the
non-energized time.)
• For solenoid valve specifications and dimensions, refer to the VQC series in the “Best Pneumatics 2004 Vol. 2” catalog.
• For SI unit dimensions, refer to page 12.
• For details on the SI unit, refer to the separate technical instruction manual.
7
Plug-in Manifold Series VQC

SDQ
VV5QC 4 1 16 03 SKit
4VQC4000
Series
Manifold
1Plug-in manifold
Stations
01 1 station
The maximum number of
stations differs depending
on the kits.
Cylinder port size
C8
C10
C12
02
03
B
CM
With one-touch fitting for ø8
With one-touch fitting for ø10
With one-touch fitting for ø12
Rc 1/4
Rc 3/8
Bottom ported Rc 1/4
Mixed size
Option
Nil None
Special wiring specification
(Except double wiring) Note)
K
Note) Be sure to indicate the wiring specification
in the specification sheet.
Nil PNP or without input block
NPN
N
Input block COM.
Nil
1
2
3
Input block type
Without input block
M12 2 inputs
M12 4 inputs
M8 4 inputs
Number of input blocks
Nil
0
1
8
Note) When an AS-i compatible S kit is used, there
is a limit on the maximum number of stations.
For details, please refer to page 13.
Without SI unit
Without input block
With 1-input block
With 8-input block
Nil
SI unit COM.
+COM.
–COM.
N
SI unit COM.
Note) Without SI unit, the symbol is nil.
DeviceNet PROFIBUS-DP CC-Link AS-i CANopen EtherNet/IPControlNet
EX250
Note 1) Indicate the size in the
specification sheet in the
case of “CM”.
Note 2) Symbols for inch sizes
are as follows:
<For one-touch fitting>
• N7: ø1/4"
• N9: ø5/16"
• N11: ø3/8"
• NM: Mixed
Kit name
Note) There is a limit on the current supplied from an SI unit of the SDTC or SDTD specification to an
input block or valve. For details, refer to page 13.
• IP40 for the S kit only, which is compatible with ControlNet. (The other S kits are competible with IP67
ratings.)
SD0
SDQ
SDN
SDV
SDY
SDTA
SDTB
SDTC Note)
SDTD Note)
SDZCN
SDZEN
Without SI unit, Without end plate
DeviceNet
PROFIBUS-DP
CC-Link
CANopen
AS-i 8in/8out 31Slave Mode, 2 power supply systems
AS-i 4in/4out 31Slave Mode, 2 power supply systems
AS-i 8in/8out 31Slave Mode, 1 power supply system
AS-i 4in/4out 31Slave Mode, 1 power supply system
ControlNet (IP40)
EtherNet/IP
EX250-SDN1
EX250-SPR1
EX250-SMJ2
EX250-SCA1
EX250-SAS3
EX250-SAS5
EX250-SAS7
EX250-SAS9
EX250-SCN1
EX250-SEN1
—
Symbol Protocol type No. of stations SI unit part no.
IP67
IP40
SKit
(Serial transmission kit for I/O)
SI unit: EX250
SI unit
Input block
End plate
Plug-in Manifold
Series VQC4000
Base Mounted
For details about certified products conforming to
international standards, visit us at www.smcworld.com.
How to Order Manifold
...
...
...
...
1 to 12 stations
(24 stations)
1 to 12 stations
(24 stations)
1 to 4 stations (8 stations)
1 to 2 stations (4 stations)
1 to 4 stations (8 stations)
1 to 2 stations (4 stations)
8

VQC 4 1 0 5
Manual override
Function
With/Without light/surge
voltage suppressor
Note 1) When two or more symbols are
specified, indicate them
alphabetically.
Note 2) Use a low wattage type for
continuous energization (when
the totaled energized time per
day is longer than the
non-energized time.)
Seal
Metal seal
Rubber seal
0
1
Ye s
Without light, with surge voltage
suppressor
Nil
E
Standard (1 W)
External pilot
Low-wattage type (0.5 W)
Nil
R
YNote 2)
Nil: Non-locking
push type
(Tool required)
B: Locking type
(Tool required)
0
Series
4VQC4000
Rated voltage
524 VDC
Type of actuation
2 position single
2 position double (Metal)
2 position double (Rubber)
3 position closed center
3 position exhaust center
3 position pressure center
3 position double check
1
2
3
4
5
6
AB
PEBEA
AB
EA P EB
AB
P
EA EB
AB
EBPEA
AB
PEA EB
AB
PEA EB
AB
EBPEA
How to Order Valves
• For solenoid valve specifications and dimensions, refer
to the VQC series in the “Best Pneumatics 2004 Vol.
2” catalog.
• For SI unit dimensions, refer to page 12.
• For details on the SI unit, refer to the separate
technical instruction manual.
9
Plug-in Manifold Series VQC

Serial Wiring with Input/Output Unit
Series EX250
Communication protocol
DN1
PR1
MJ2
AS3
AS5
AS7
AS9
CA1
CN1 Note)
EN1
DeviceNet
PROFIBUS-DP
CC-Link
AS-i (8in/8out 31Slave Mode, 2 power supply systems)
AS-i (4in/4out 31Slave Mode, 2 power supply systems)
AS-i (8in/8out 31Slave Mode, 1 power supply system)
AS-i (4in/4out 31Slave Mode, 1 power supply system)
CANopen
ControlNet
EtherNet/IP
DN1EX250 S
How to Order SI Unit
SI Unit
For options, refer to page 16.
Note) The enclosure rating is IP40 for the SI unit compatible with ControlNet.
Input block Output block
Power block
SI unit
Input block
SI unit
Output block
Integrated serial wiring • Ease of mounting, and space-savings are achievable, integrating wiring by connector.
Input/Output number • Compatible with 32-digital outputs/inputs.
Enclosure • IP67 compatible (IP40: compliant with ControlNet)
10

SI Unit Specifications
EX250-SAS7 ··· Max.250 mA, EX250-SAS9 ··· Max.120 mA
Model
EX250-SDN1
125 k/250 k/
500 kbps
9.6 k/19.2 k/
45.45 k/93.75 k/
187.5 k/500 kbps
1.5 M/3 M/
6 M/12 Mbps
156 k/
625 kbps
2.5 M/5 M/
10 Mbps
10 k/20 k/
50 k/125 k/
250 k/500 k/
800 kbps/
1 Mbps
5 Mbps
21.6 to 26.4 VDC
100 mA or less
22.8 to 26.4 VDC
26.5 to 31.6 VDC
—
26.5 to 31.6 VDC Note 2)
—
10 M/
100 Mbps 167 kbps
Applicable
system
Communication speed
Power supply
for input and
internal control
Power supply
for output
Power supply for
communication
Input
Output
Environmental
resistance
Standard
Weight
Accessory
11 to 25 VDC — 26.5 to 31.6 Vb Note 2)
SAS3: 100 mA or less
SAS5: 65 mA or less
SAS7: 100 mA or less
SAS9: 65 mA or less
SAS3: 8 points
SAS5: 4 points
SAS3: max. 240 mA
SAS5: max. 2120 mA
SAS7: 8 points
SAS9: 4 points
SAS7: 8 points
SAS9: 4 points
Note 3)
Note 3)
100 mA or less
PNP output (–COM.)
32 points
Max. 2.0 A
IP67
Operating: 5 to 45C Stored: –20 to 60C (with no freezing and condensation)
Operating, Stored: 35 to 85%RH (with no condensation)
500 VAC for 1 min. between whole charging part and case
10 M or more (500 VDC Mega) between whole charging part and case
10 to 150 Hz with a 0.7 mm amplitude or 50 m/s2in each X, Y, Z direction for 2 hrs (De-energized)
150 m/s2in each X, Y, Z direction, 3 times (De-energized)
CE marking (CSA)
250 g
2 pcs.
IP40 IP67
Solenoid valve (single, double), Output block, Power block Note 6)
24 VDC
—
32 points (Based on input block connection) Note 5)
24 VDC
Max. 1.0 A
EX250-SPR1
NPN output (+COM.)
PNP output (–COM.)
EX250-SMJ2 EX250-SCA1 EX250-SCN1 EX250-SEN1
EX250-SAS3/5 EX250-SAS7/9
Power supply voltage
Internal current
consumption
Power supply voltage
Power supply voltage
Protocol
Version Note 1)
Internal current
consumption
Number of inputs
Supply current
Supply current
Output type
Number of outputs
Connection block
Supply voltage
Supply voltage
Enclosure
Operating tempera-
ture range
Operating humidity
range
Withstand voltage
Insulation resistance
Vibration resistance
Impact resistance
Tie-rod Note 4)
SAS3: 8 points
SAS5: 4 points
SAS3: max. 500 mA
SAS5: max. 250 mA
DeviceNet
PROFIBUS-DP
CC-Link CANopen
CiA DS-301
V4.02 and
CiA DS-401
Version 2.0
Errata 3
adapter class
ControlNet EtherNet/IP
Release 2.0 V0 Ver.1.10 Release1.0
AS-Interface (AS-i)
Version 2.11
Standard Address Mode
Maximum Transmission Distance
Model Maximum transmission distance
EX250-SDN1
EX250-SPR1
EX250-SMJ2
EX250-SCA1
EX250-SCN1
EX250-SEN1
EX250-SAS3/5
EX250-SAS7/9
500 m (125 kbps), 250 m (250 kbps), 100 m (500 kbps)
23 km (Repeater required)
1200 m (156 kbps), 900 m (625 kbps), 400 m (2.5 Mbps), 160 m (5 Mbps), 100 m (10 Mbps)
5000 m (10 kbps), 2000 m (20 kbps), 1000 m (50 kbps), 500 m (125 kbps), 250 m (250 kbps), 100 m (500 kbps), 50 m (800 kbps), 25 m (1 Mbps)
1000 m (Tap number: 2)
100 m (10/100 Mbps)
300 m (when using a repeater)
Note 2)
Note 1) Please note that the version is subject to change.
Note 2) The EX250-SAS7/9 is powered by the single system spec., in which the communication power source is separeted into input, power supply for internal control, and/or for
output.
Note 3) The EX250-SAS7/9 is powered by the single system spec., that is separeted for use depending on the aggregated values of input/output supply power as shown below.
(For details, refer to page 13.)
Note 4) When the SI unit is integrated into manifold, its tie-rod is also incorporated at the time of shipping.
Note 5) For connected input equipment, refer to page 14.
Note 6) For connected output equipment, refer to page 21.
11
Serial Wiring with Input/Output Unit Series EX250

BUS
63
Communication connector
(M12, 4 pins, plug)
59.8
PWR
BUS
63 Ground terminal
Communication connector
(M12, 4 pins, plug)
Connector for output device connection
(M12, 4 pins, plug)
59.8
ADDRESS SETTING
SW
EX250
ADDR2ADDR1
HOLD
CLEAR
COM
-ERR
IN
AUX -ERR
PWR
SI
64.4
75.1
Position indicator LED
Switch protective cover
ADDRESS SETTING
SW
EX250
ADDR2ADDR1
HOLD
CLEAR
COM
-ERR
IN
AUX -ERR
PWR
SI
64.4
75.1
Position indicator LED
Switch protective cover
75.1
64.4
EX250
0
1
ADDRESS
PWR
CAN
PWR(V)
Switch protective cover
Position indicator LED
59.8
PWR
BUS
Ground terminal
Communication connector
(M12, 5 pins, plug)
Power supply connector
(M12, 5 pins, plug, reverse key)
63 63
59.8
-----
PWR
BUS
Ground terminal
Communication connector
(M12, 4 pins, socket, Type D)
Power supply connector
(M12, 5 pins, plug)
PWR
A
63
59.8
Ground terminal
Communication connector (BNC)
Power source connector
(M12, 5 pins, plug, reverse key)
AMS
X10 X1
SELECT ADDRESS
PWR(V)
PWR
64.4
77.6
SI UNIT
Position indicator LED
Switch protective cover
78.9
64.4
MS
0
1
SETTINGS
PWR
NS
SOL
Position indicator LED
Switch protective cover
PWR
BUS
Ground terminal
Communication connector
(M12, 5 pins, plug)
Power supply connector
(M12, 5 pins, plug, reverse key)
63
59.8
PWR
BUS
Ground terminal
Communication connector
(M12, 5 pins, socket, reverse key)
Power supply connector
(M12, 5 pins, plug)
63
59.8
MOD/NETPWR(V)
EX250
SI
PWR
SETTINGS
0
1
64.4
75.1
Position indicator LED
Switch protective cover
BF
DIA
L
H
ADDRESS
RUN
PWR(V)
EX250
SI
64.4
78.9
Position indicator LED
Switch protective cover
L ERR
L RUN
x1
x10
STATION NO.
B RATE
PW
PW(V)
EX250
SI
LINK IN
(M12, 4 pins, plug)
LINK OUT
(M12, 4 pins, socket)
Bus adapter
64.4
Max.118
Position indicator LED Switch protective cover
PWR
Ground terminal
63
59.8
Power supply connector
(M12, 5 pins, plug, reverse key)
SI Unit Dimensions / Parts Description
EX250-SDN1 (DeviceNet) EX250-SMJ2 (CC-Link)EX250-SPR1 (PROFIBUS-DP)
EX250-SCA1 (CANopen) EX250-SEN1 (EtherNet/IP)EX250-SCN1 (ControlNet)
AS-i
EX250-SAS7/9 (1 power supply system) EX250-SAS3/5 (2 power supply systems)
12
Series EX250

Be sure to read this before handling. Please consult with SMC for applications outside the specifications.
When one AS-i power supply system is used
Maximum number of AS-i compatible input blocks
Specific Product Precautions
EX250-SAS7 EX250-SAS9
Supplied from AS-i circuit, 26.5 to 31.6 VDC Note 1)
24 VDC
Max. 100 mA
8
8
Max. 240 mA
Max. 65 mA
4
4
Max. 120 mA
Power supply voltage
Internal current consumption
Number of inputs
Number of outputs
Supply voltage
Supply current Note 2)
Note 1) For communication power supply, use a power supply
dedicated to AS-i. For details, please refer to instruction
manuals provided by the respective manufacturers.
Note 2) The AS-i circuit provides current to the internal parts of
the SI unit and all connected equipment.
Since there is a limit on the possible supply current to all
connected equipment, select the equipment connected to
the input/output device to stay within the possible supply
current.
Example) When EX250-SAS9 is used
Valve: VQC1100NY – 5 (low-wattage type of 0.5 W) x 4 pcs.
0.5 [W] 24 [V] x 4 [pcs.] = 84 [mA] (4 outputs simultaneously ON)
The maximum possible supply current of EX250-SAS9 is 120 mA. Therefore, the possible supply current to the sensor is
120 [mA] – 84 [mA] = 36 [mA]
Use of low-wattage type valves by minimizing the maximum number of simultaneous outputs, and low current consumption
sensors (2-wire sensor, etc.) is recommended.
Caution
AS-i 8in/8out 31SlaveMode, 2 power supply systems
AS-i 4in/4out 31SlaveMode, 2 power supply systems
AS-i 8in/8out 31SlaveMode, 1 power supply system
AS-i 4in/4out 31SlaveMode, 1 power supply system
1
2
3
1
2
3
1
2
3
1
2
3
4 stations
2 stations
2 stations
2 stations
1 station
1 station
4 stations
2 stations
2 stations
2 stations
1 station
1 station
M12/2 inputs
M12/4 inputs
M8/4 inputs
M12/2 inputs
M12/4 inputs
M8/4 inputs
M12/2 inputs
M12/4 inputs
M8/4 inputs
M12/2 inputs
M12/4 inputs
M8/4 inputs
SI unit specifications
Input block maximum stations
Input block type
EX250-SAS3
EX250-SAS5
EX250-SAS7
EX250-SAS9
Input/output
specification
13
Serial Wiring with Input/Output Unit Series EX250

Input Block Specifications
How to Order Input Block
EX250 IE 1
Block type
1
2
3
M12 connector, 2 inputs
M12 connector, 4 inputs
M8 connector, 4 inputs
Note 1) When the maximum inputs to the SI unit is reached by adding an input block, pay attention not to exceed the supply current for the SI unit input.
Note 2) When the SI unit is integrated into manifold, its tie-rod is also incorporated at the time of shipping.
Model EX250-IE1
PNP/NPN input (switched using a switch)
24 VDC
Max. 30 mA/point Note 1)
Approx. 8 mA
Green LED (Illuminated when the power supply for the SI unit input is applied),
Yellow LED (Illuminated when the input signal is turned on.)
IP67
Operating: 5 to 45C Stored: –20 to 60C (with no freezing and condensation)
Operating, Stored: 35 to 85%RH (with no condensation)
500 VAC for 1 min. between whole charging part and case
10 M or more (500 VDC Mega) between whole charging part and case
10 to 150 Hz with a 0.7 mm amplitude or 50 m/s2in each X, Y, Z direction for 2 hrs (De-energized)
150 m/s2, in each X, Y, Z direction, 3 times (De-energized)
CE marking, UL (CSA)
90 g
2 pcs.
2 points
M12 connector (4 pins, plug or 5 pins, plug) M8 connector (3 pins, plug)
4 points
Input
specification
Environmental
resistance
Standard
Weight
Accessory
EX250-IE2 EX250-IE3
Input type
Number of inputs
Input device supply voltage
Input device supply current
Rated input current
Display
Connector on the input device side
Enclosure
Operating temperature range
Operating humidity range
Withstand voltage
Insulation resistance
Vibration resistance
Impact resistance
Tie-rod Note 2)
Input Block
Input block Output block
Power block
SI unit
Input block
SI unit
Output block
For options, refer to page 16.
14
Series EX250

Input Block Dimensions / Parts Description
EX250-IE1, EX250-IE2
EX250-IE3
Note) Fuse for overcurrent protection
If addressing the possible cause of a problem, even when the fuse is blown, it can be reinstated by replacing with a fuse as shown in options, page 19.
EX250-IE1 EX250-IE2
Fuse Note) NPN/PNP convertion switch
EX250
1
0
21
72.6
Position indicator LED
0
1
59.8
Connector for
input device connection
(M12, 5 pins, socket)
3
2
1
0
EX250
21
72.6
Position
indicator LED
Fuse Note) NPN/PNP convertion switch
3
2
1
0
EX250
67.4
21
Position indicator LED
3
2
1
0
59.8
Connector for
input device connection
(M8, 3 pins, socket)
PNP
NPN
SW
+24 V
Fuse
E
0 V
q
r
e
w
t
q
r
e
w
t
SW PNP
NPN
0 V E
+24 V
Fuse q
r
e
w
t
q
r
e
w
t
0 V
PNP
NPN
SW
+24 V
Fuse q
r
e
q
r
e
q
r
e
q
r
e
Circuit diagram: EX250-IE1
Circuit diagram: EX250-IE2
Circuit diagram: EX250-IE3
Connector’s pin assignment for the
input device connection
(M12, 5 pins, socket)
Connector’s pin assignment for the
input device connection
(M8, 3 pins, socket)
t
wq
re
r
q e
Internal circuit Internal circuit
Internal circuit
15
Serial Wiring with Input/Output Unit Series EX250

Options
uPower block
yOutput block yOutput block
SI unit
Input block
SI unit
Input block
tEnd plate (Input side)
eWaterproof
cap
eWaterproof
cap
oPower cable
with connector
qCommunication
connector
qCommunication connector
wPower cable with connector
(for SI unit) wPower cable with connector
(for SI unit)
iCable with connector
for output entry
SI unit
Input block
tEnd plate (Input side)
uPower block
yOutput block
eWaterproof cap
tEnd plate (Input side)
oPower cable with connector !0 AS-i power supply cable
SI unit
uPower block
yOutput block
eWaterproof
cap
!1 End plate
(Output side)
tEnd plate (Input side)
oPower cable with connector
wPower cable with connector
(for SI unit)
Connection example of the SI unit
compliant with EtherNet/IP
Connection example of the SI unit
compliant with PROFIBUS-DP
Connection example of the SI unit
compliant with DeviceNet
Connection example of the SI unit
compliant with AS-i
Example of connections
16
Series EX250

qCommunication connector
For DeviceNet type SI unit
For EtherNet/IP type SI unit
050EX500 AC DN
Cable length (l)
1000 [mm]
5000 [mm]
010
050
020EX9 AC EN
Cable length (l)
2000 [mm]
020
PSRJ
Connector specification
M12 plug (straight)⇔RJ-45 connector
PSRJ
2
43
5
Socket connector
pin arrangement
11
23
4
5
Red: V+
White: CAN H
: DRAIN
Black: V–
Blue: CAN L
Connections
Terminal no. Core wire colors
ø14.9
l
ø7
40.7
50
M12
1
34
2
Plug connector
pin arrangement
Terminal no.
1
2
3
4
1
2
3
4
5
6
7
8
Terminal
no.
Connections (Straight cable)
Shield
Core wire
colors
Pair
Pair
White
Orange
White
Green
ø6.7
47.3 45
l
M12 RJ45
1
2
3
4
5
6
7
8
Plug connector
pin arrangement
17
Serial Wiring with Input/Output Unit Series EX250

Options
wPower cable with connector (for SI unit)
EX500 AP
2
43
5
Socket connector
pin arrangement
1
1
2
3
4
5
White: 24 VDC +10%/–5% (Solenoid valve power supply)
Black: 24 VDC 10% (Input and control power supply)
Brown: 0 V (Solenoid valve power supply)
Blue: 0 V (Input and control power supply)
Gray: PE
Terminal no. Core wire colors
M12
ø14.9
48
34
18
l
ø6
30 5
50
Connections
Cable length (l)
1000 [mm]
5000 [mm]
010
050
S050
For PROFIBUS-DP, EtherNet/IP type SI unit
For the SI unit (except for PROFIBUS-DP, AS-i, EtherNet/IP) and power block
EX9 AC 1
Cable length (l)
1000 [mm]
3000 [mm]
5000 [mm]
010
030
050
050
eWaterproof cap: M8, M12 connector (for socket)
EX500 AW
Use this on ports that are not being used for M8 and M12 connectors (socket).
Use of this waterproof cap maintains the integrity of the IP65 enclosure.
Note) Tighten the waterproof cap with the prescribed tightening torque. (For M8: 0.05 N•m, For M12: 0.1 N•m)
ES
TS
Connector type
M8 connector (for socket), 10 pcs.
M12 connector (for socket), 10 pcs.
M8 connector (for socket) M12 connector (for socket)
M12 x 1
14
10.2
M8 x 1
6.6
10.8
14
11
2
43
51
Socket connector
pin arrangement
M12 48.1
l
30
50
5
ø6.4
Connections
1
2
3
4
5
Terminal no. Core wire colors
Brown: 24 VDC (Output power supply)
White: 0 V (Output power supply)
Blue: 24 VDC (Input and internal control power supply)
Black: 0 V (Input and internal control power supply)
Gray: PE
18
Series EX250

rReplacement fuse
Replacement fuse required when the fuse for the input block (EX250-IE쏔) overcurrent protection is blown.
EX9 FU05
tEnd plate (Input side)
Model EX9-FU05
Applicable model
Rated current
Rated insulation capacity
Fuse resistance value
EX250-IE쏔
0.5 A
48 VAC/DC 50 A
0.36
EX250 EX250-EA1
EX250-EA2
EA
1
2
Mounting specification
Direct mounting
DIN rail mounting
Accessory
Hexagon socket head cap screw (M3 x 10): 2 pcs.
Fuse
18
10
13.2
60
75
18
10
13.2
60
75
64.4
66
18
12.5
M4 clamp screw
64.4
66
18
12.5
Mounting hole for 2-M4
1
19
Serial Wiring with Input/Output Unit Series EX250

Features: • Able to retrofit to the valve manifold, using the unused points.
• 2-output (M12 connector)
• + common / – common are standardized.
• Able to drive by 0.5 A per point.
yOutput block / uPower block
How to Order Output Block
EX9 OE
Output specification
PNP output (–COM.)
NPN output (+COM.)
1
2
1T
How to Order Power Block
EX9 PE1
Power supply type
Option/Part No.
Description Part no. Note
Waterproof cap
Power cable with
connector
Cable with connector
for between SI unit
and power block
AS-i power supply
cable
EX500-AWTS
EX9-AC쏔-1
EX9-AC002-2
EX9-AC002-3
EX9-AC002-4
EX9-AC쏔-5
Refer to page 18.
Order separately: 10 pcs. included
Refer to page 18,
Order separately.
Refer to page 23,
Order separately.
Refer to page 24,
Order separately.
Output block Power block
SI Unit Part No.
SI unit part no. Output Applicable model
EX250-SDN1
EX250-SPR1
EX250-SAS쏔
EX250-SCA1
EX250-SCN1
EX250-SEN1
EX250-SMJ2
–COM.
+COM.
EX9-OET1
EX9-OEP1
EX9-OET2
EX9-OEP2
Option/Part No.
Description Part no. Applicable model
OET쏔OEP쏔Note
Waterproof cap
Power block
Cable with connector
for output entry
Refer to page 18.
Order separately: 10 pcs. included
Refer to page 23.
Order separately.
Refer to page 20.
Order separately.
EX500-AWTS
EX9-AC쏔-7
EX9-PE1
Input block Output block
Power block
SI unit
Input block
SI unit
Output block
Options
Internal power supply method
(for low-wattage load)
Integrated power supply method
(for high-wattage load) Note)
T
P
Note) Required to connect with a power block.
20
Series EX250
Other manuals for SV Series
3
This manual suits for next models
7
Table of contents