W 10S1
1
2
3
SV1000
SV2000
SV3000
Series
Stations
Note
Double wiring
specification Note 1)
Specified layout Note 2)
(Up to 32
solenoids possible.)
Symbol
02
16
02
20
No. of stations
2 stations
16 stations
2 stations
20 stations
• When an AS-i compatible SI unit is used, the
maximum numbers of solenoids are as follows:
8in/8out specification: Maximum 8 solenoids
4in/4out specification: Maximum 4 solenoids
Note 1) Double wiring specifica-
tion: Single, double, 3
position and 4 position
solenoid valves can be
used on all manifold
stations.
Use of a single solenoid will result
in an unused control
signal. If this is not
desired, order with a
specified layout.
Note 2) Specified layout: Indicate
wiring specification in the
manifold specification
sheet. (Note that double, 3
position and 4 position valves
cannot be used where
single solenoid wiring has
been specified.)
쎲Tie-rod Base
SS5V D1
Input block common
specification
+COM. or without input block
–COM.
Nil
N
A, B port size (Inch)
A, B port
Symbol
N1
N3
N7
N3
N7
N9
N7
N9
N11
M
With one-touch fitting for ø1/8"
With one-touch fitting for ø5/32"
With one-touch fitting for ø1/4"
With one-touch fitting for ø5/32"
With one-touch fitting for ø1/4"
With one-touch fitting for ø5/16"
With one-touch fitting for ø1/4"
With one-touch fitting for ø5/16"
With one-touch fitting for ø3/8"
A, B ports mixed
With one-touch
fitting for
ø5/16"
P, E port
Applicable series
SV1000
SV2000
SV3000
With one-touch
fitting for
ø3/8"
With one-touch
fitting for
ø3/8"
A, B port size (Metric)
A, B port
Symbol
C3
C4
C6
C4
C6
C8
C6
C8
C10
M
With one-touch fitting for ø3.2
With one-touch fitting for ø4
With one-touch fitting for ø6
With one-touch fitting for ø4
With one-touch fitting for ø6
With one-touch fitting for ø8
With one-touch fitting for ø6
With one-touch fitting for ø8
With one-touch fitting for ø10
A, B ports mixed
With one-touch
fitting for
ø8
P, E port
Applicable series
SV1000
SV2000
SV3000
With one-touch
fitting for
ø10
With one-touch
fitting for
ø12
SI unit
DeviceNet
PROFIBUS-DP
CC-Link
AS-i 8in/8out 31Slave Mode , 2 power supply systems
AS-i 4in/4out 31Slave Mode , 2 power supply systems
AS-i 8in/8out 31Slave Mode, 1 power supply system
AS-i 4in/4out 31Slave Mode, 1 power supply system
CANopen
ControlNet (IP40)
EtherNet/IP
Without SI unit, Without end plate
QW
NW
VW
TAW
TBW
TCW
TDW
YW
ZCN
ZEN
0
• Input blocks cannot be mounted without SI unit.
• When the DIN rail is included without an SI unit, the DIN rail length will
accommodate an SI unit and one input block.
Note 1) There is a limit on the current supplied from an SI unit of AS-i
compatible 1 power supply system specification to an input block or
valve. For details, refer to page 13.
Note 2) IP40 when the SI unit spec is only compatible with ControlNet.
(Manifold model no. is “SS5V쏔-10S1ZCN쏔쏔쏔D”.)
Note 3) For SI unit part no., refer to page 3.
∗In the case of mixed specification (M), indicate separately in the manifold specification sheet.
∗Port sizes of X, PE port for external pilot specification (R, RS) are ø4 (metric), ø5/32" (inch) for the SV1000/2000 series and ø6
(metric) and ø1/4" (inch) for the SV3000 series.
Input block stations
None
1 station
8 stations
Nil
1
8
Note) Without SI unit, the
symbol is nil.
When an AS-i compatible
S kit is used, there is
a limit on the
maximum number of
stations. For details,
please refer to page
13.
How to Order
EX250 Serial Wiring
With Input/Output Unit
Series SV
05 U
P, E port position
U
D
B
U side (2 to 10 stations)
D side (2 to 10 stations)
Both sides (2 to 20 stations)
3 stations
20 stations
When a longer DIN rail is
desired than the specified
stations.
(Specify a longer rail than
the standard length.)
Mounting
Nil
D
D0 Note)
D3
D20
Note) In the case of D0, only DIN rail
brackets are attached.
SUP/EXH block assembly specification
Internal pilot
Internal pilot, Built-in silencer
External pilot
External pilot, Built-in silencer
Nil
SNote)
R
RS Note)
Note) When the built-in silencer type is used,
keep the exhaust port from coming in
direct contact with water or other liquids.
Enclosure
IP67 specification
QW
Without input block
M12 2 inputs
M12 4 inputs
M8 4 inputs
Input block type
Nil
1
2
3
Note) Without SI
unit, the
symbol is nil.
For details about certified products conforming to
international standards, visit us at www.smcworld.com.
Direct mounting
DIN rail mounting (with DIN rail)
DIN rail mounting (without DIN rail)
...
...
...
...
...
...
...
...
2