.5..4.2. Safety Instructions2. Safety Instructions2.1 Safety Symbols Safety symbols used in this manual, which highlight potential safety risks and important safety information, are listed as follows:2.2 General Safety InstructionsCAUTION:Risk of electric shock from energy stored in capacitors of the Inverter. Do not remove cover for 5 minutes after disconnecting all power sources(service technician only). Warranty may be voided if the cover is removed without unauthorized.CAUTION:The surface temperature of the inverter can exceed 75℃ (167F).To avoid risk of burns, DO NOT touch the surface when inverter is operating.The inverter must be installed out of reach of children.CAUTION: CAUTION, RISK OF ELECTRIC SHOCK symbol indicates important safety instructions, which if not correctly followed, could result in electric shock.CAUTION: CAUTION, HOT SURFACE symbol indicates safety instructions, which if not correctly followed, could result in burns.NOTE: NOTE symbol indicates important safety instructions, which if not correctly followed, could result in some damage or the destruction of the inverter.WARNING: WARNING symbol indicates important safety instructions, which if not correctly followed, could result in serious injury or death.WARNING: Electrical installations must be done in accordance with the local and national electrical safety standards.WARNING:Please don’t connect PV array positive(+) or negative(-) to ground, it could cause serious damage to the inverter.CAUTION: The PV array (Solar panels) supplies a DC voltage when they are exposed to sunlight.WARNING: To reduce the risk of fire, over-current protective devices (OCPD) are required for circuits connected to the Inverter. The DC OCPD shall be installed per local requirements. All photovoltaic source and output circuit conductors shall have disconnects that comply with the NEC Article 690, Part II. All Solis three phase inverters feature an integrated DC switch. CAUTION: Risk of electric shock. Do not remove cover. There is no user serviceable parts inside. Refer servicing to qualified and accredited service technicians.2.3 Notice For UseThe inverter has been constructed according to the applicable safety and technical guidelines. Use the inverter in installations that meet the following specifications only:Permanent installation is required.The electrical installation must meet all the applicable regulations and standards. The inverter must be installed according to the instructions stated in this manual.The inverter must be installed according to the correct technical specifications.To startup the inverter, the Grid Supply Main Switch (AC) must be switched on, beforethe solar panel's DC isolator shall be switched on. To stop the inverter, the Grid Supply Main Switch (AC) must be switched off before the solar panel's DC isolator shall be switched off.2.4 Notice for DisposalThis product shall not be disposed of with household waste. They should be segregated and brought to an appropriate collection point to enable recycling and avoid potential impacts on the environment and human health. Local rules in waste management shall be respected .