Quick Installation Guide
ASW6000-S / ASW8000-S/ASW10000-S
1. The contents of this document may be updated due to product upgrades or other reasons. Unless
otherwise specified, this document only works as guide. All statements, information and
suggestions in this document do not constitute any guarantee.
2. This product can only be installed, commissioned, operated and maintained by technicians who
have carefully read and fully understood the user manual.
3. This product must only be connected with PV modules of protection class II (in accordance with
IEC 61730, application class A). PV modules with a high capacitance to ground must only be used
if their capacity does not exceed 1μF. Do not connect any sources of energy other than PV
modules to the product.
4. When exposed to sunlight, the PV modules generate dangerous high DC voltages which is present
in the DC cable conductors and live components. Touching live DC cable conductors and live
components can result in lethal injuries due to electric shock.
5. All components must remain within their permitted operating ranges at all times.
6. The product complies with Electromagnetic compatibility 2014/30/EU, Low Voltage Directive
2014/35/EU and Radio Equipment Directive 2014/53/EU.
1. Ensure that the inverter is installed out of the reach of children.
2. To ensure best operating status and prolonged service life, the
ambient temperature of the location should be ≤40°C.
3. To avoid direct sunlight, rain, snow, pooling of water on the inverter, it is
suggested to mount the inverter in places which are shaded during the majority of
the day or to install an external cover that provides shade for the inverter.
Do not place a cover directly on top of the inverter.
4. The mounting condition must be suitable for the weight and size of the inverter. The inverter is suitable
to be mounted on a solid wall that is vertical or tilted backwards (Max. 15°). It is not recommended to
install the inverter on walls made of plasterboards or similar materials. The inverter may emit noise
during operation.
5. To ensure adequate heat dissipation, the recommended clearances between the
inverter and other objects are shown in the image to the right:
1. Use a Φ10mm bit to drill 2 holes at a depth of about 70mm according to the location of the wall
mounting bracket. (Figure A)
2. Insert the wall plugs into the wall and fix the mounting bracket to the wall by inserting two Screws
(SW10). (Figure B)
3. Push the inverter to wall bracket and hook it. Ensure the two right- and left-hand keys on the outer ribs
of the inverter must be hooked into the respective keyways in the wall mounting bracket. (Figure C)
4. Ensure that the inverter is securely in place, then secure the inverter to the mounting bracket on both
sides using two M5 screws. Screwdrivertype:PH2, torque:2.5Nm. (Figure D)
1. Strip the AC cable as shown in the figure,and crimp the copper wire to the appropriate cord end
terminal (according to DIN 46228-4, provided by the customer).
Object
Description
Value
A
External diameter
14-20mm
B
Copper conductor cross-section
6-16mm2
C
Stripping length of the insulated conductors
16mm
D
Stripping length of the cable outer sheath
46mm
Note: the PE conductor is at least 5mm longer than the L and N conductors.
2. Insert the PE, N and L conductor into the cord end terminal, insert them into the corresponding
terminals of the AC connector in the order as shown, and tighten the screws by the hex key with a
suggested torque of 2.0 Nm.
3. Secure the connector body assemble to the connector, then tighten the nut cap to the connector
body.
4. Insert the AC connector plug into the output socket of AC connector corresponding to the inverter and
tighten them.
5. If required, you can connect a second protective conductor as equipotential bonding.
6. if required,you can use a slot type screwdriver to disassemble the AC connector plug from the inverter.
Object
Description
M5 screw
Screwdriver type: PH2, torque: 2.5Nm
OT terminal lug
Customer provided, type: M5
Grounding cable
Copper conductor cross-section: 6-16mm2
2
Figure A
Figure B
I. Safety Instruction
II. Mounting environment
IV. Inverter's mounting
Figure C
Figure D
V. AC connection
▪All electrical installations must be done in accordance with all local and national rules.
▪Ensure that all DC switches and AC circuit breakers have been disconnected and all power sources
have been electrically isolated before any electrical terminations have been made. High voltages
produced by the inverter may lead to electrical shock.
▪In accordance with safety regulations, the inverter needs be correctly grounded. When a poor
ground connection (PE) occurs, the inverter will report PE grounding error. Please check and ensure
that the inverter is grounded firmly or contact AISWEI service.
3
1
III. Scope of delivery
1. Please refer to “DC Connector Installation Guide”.
2. if do not connect DC connector plugs please keep the sealing plug staying
on the DC connector socket to ensure protection degree.
1. COM1&COM2: RS485
1) RS485 cable pin assignment as below, strip the wire as shown in the figure, and crimp the copper wire to
the appropriate OT terminal (according to DIN 46228-4, provided by the customer)
2) Unscrew the communication port cover cap in the following arrow sequence and insert the network cable
into the RS485 communication client attached.
3) Insert the network cable into the corresponding communication terminal of the inverter according to the
arrow sequence, tighten the thread sleeve, and then tighten the forcing nut at the tail.
2. COM3: WiFi/4G
Insert the WiFi stick plug and then tighten it to the WiFi connector socket as shown.
3. Meter
1) Loosen the swivel nut of the connector plug. Insert the crimped conductors into corresponding
terminals and tighten screws with the screwdriver as shown. Torque: 0.5-0.6 Nm
2) Remove the dust cap from the socket of the meter connector,and insert the meter plug for connecting
with meter cable.
1. Switch on AC circuit breaker between the inverter and the grid.
2. Switch on DC switch.
3. Please refer to the AiProfessional/Aiswei App manual for commissioning of the inverter via Wifi.
4. When there is sufficient DC power and the grid conditions are met, the inverter will start to
operate automatically.
Within the scope of the EU directives:
- Electromagnetic compatibility 2014/30/EU
(L 96/79-106 ,March 29, 2014)(EMC)
- Low voltage directive 2014/35/EU (L 96/357-374 ,March 29, 2014)(LVD)
- Radio equipment directive 2014/53/EU (L 153/62-106 ,May 22, 2014)(RED)
AISWEI New Energy Technology (Jiangsu) Co., Ltd. confirms herewith that the inverters
mentioned in this document are in compliance with the fundamental requirements and
other relevant provisions of the above mentioned directives.
The entire EU Declaration of Conformity can be found at www.aiswei-tech.com.
If you have any technical problems with our products, please contact our service.
Provide the following information to assist in providing you with the necessary
assistance:
- Inverter device type
- Inverter serial number
- Type and number of connected PV modules
- Error code
- Mounting location
- Warranty card
AISWEI New Energy Technology (Jiangsu)Co., Ltd.
Web: https://solplanet.net
Add.: No. 198 Xiangyang Road, Suzhou 215011, China
AISWEI Pty Ltd.
Hotline: +61 390 988 673
Service email: service.au@aiswei-tech.com
Add.: Level 40, 140 William Street, Melbourne VIC 3000, Australia
AISWEI B.V.
Hotline: +31 208 004 844 (Netherlands)
+48 134 926 109 (Poland)
Service email: service.eu@aiswei-tech.com
Add.: Barbara Strozzilaan 101, 5e etage, kantoornummer 5.12, 1083 HN, Amsterdam, The Netherlands
Rest of the world
Service email: service. row@aiswei-tech.com
6
VII. Communication setup
▪Separate communication cables from power cables and serious interference sources.
▪The communication cables must be CAT-5E or higher-level shield cables. Pin assignment complies with
EIA/TIA 568B standard. For outdoor use, the communication cables must be UV-resistant. The total
length of communication cable cannot exceed 1000m.
▪If only one communication cable is connected, insert a sealing plug into the unused hole of sealing
ring of the cable gland.
▪Before connecting communication cables, ensure the protective film or communication plate attached to the
communication opening on the inverter is sealed tightly.
4
▪Only applicable to the company's products, can’t be connected to other USB devices.
▪The connection refers to “4G/ WiFi-stick User Manual”.
5
VI.DC connection
▪Make sure PV modules have good insulation against ground.
▪On the coldest day based on statistical records, the Max. open-circuit voltage of the PV modules must
not exceed the Max. input voltage of the inverter.
▪Check the polarity of DC cables.
▪Ensure that DC switch has been disconnected.
▪Do not disconnect DC connectors under load.
VIII. Commissioning
▪Check that the inverter is grounded reliably.
▪Check that the ventilation condition surrounding the inverter is good.
▪Check that the grid voltage at the point of connection of the inverter is within the permitted range.
▪Check that the sealing plugs in DC connectors and the communication cable gland are sealed tightly.
▪Check that grid connection regulations and other parameter settings meet safety requirements.
IX. EU Declaration of Conformity
X. Contact
7

This manual suits for next models

2

Other Solplanet Inverter manuals

Solplanet ASW45K-LT-G3 User manual

Solplanet

Solplanet ASW45K-LT-G3 User manual

Solplanet ASW S-G2 Series User manual

Solplanet

Solplanet ASW S-G2 Series User manual

Solplanet ASW S Series User manual

Solplanet

Solplanet ASW S Series User manual

Solplanet ASW30K-LT-G2 User manual

Solplanet

Solplanet ASW30K-LT-G2 User manual

Solplanet ASW45K-LT-G3 User manual

Solplanet

Solplanet ASW45K-LT-G3 User manual

Solplanet LT Series User manual

Solplanet

Solplanet LT Series User manual

Solplanet ASW LT Series User manual

Solplanet

Solplanet ASW LT Series User manual

Solplanet ASW H-T1 Series User manual

Solplanet

Solplanet ASW H-T1 Series User manual

Solplanet ASW LT-G3 Series User manual

Solplanet

Solplanet ASW LT-G3 Series User manual

Solplanet ASW75K-LT User manual

Solplanet

Solplanet ASW75K-LT User manual

Solplanet ASW75K-LT User manual

Solplanet

Solplanet ASW75K-LT User manual

Solplanet ASW25K-LT-G3 User manual

Solplanet

Solplanet ASW25K-LT-G3 User manual

Solplanet ASW LT Series User manual

Solplanet

Solplanet ASW LT Series User manual

Solplanet ASW LT-G2 Pro Series User manual

Solplanet

Solplanet ASW LT-G2 Pro Series User manual

Solplanet ASW S-GW Series User manual

Solplanet

Solplanet ASW S-GW Series User manual

Solplanet ASW3000-T User manual

Solplanet

Solplanet ASW3000-T User manual

Solplanet ASW LT Series User manual

Solplanet

Solplanet ASW LT Series User manual

Solplanet ASW S Series User manual

Solplanet

Solplanet ASW S Series User manual

Solplanet ASW S-A Series User manual

Solplanet

Solplanet ASW S-A Series User manual

Solplanet ASW LT G2 Series User manual

Solplanet

Solplanet ASW LT G2 Series User manual

Solplanet ASW30K-LT-G2 User manual

Solplanet

Solplanet ASW30K-LT-G2 User manual

Solplanet ASW05kH-T2 User manual

Solplanet

Solplanet ASW05kH-T2 User manual

Solplanet ASW08KH-T1 User manual

Solplanet

Solplanet ASW08KH-T1 User manual

Solplanet ASW05kH-T2 User manual

Solplanet

Solplanet ASW05kH-T2 User manual

Popular Inverter manuals by other brands

ZONHAN CM30D series user manual

ZONHAN

ZONHAN CM30D series user manual

PrimeVOLT PV T U Series Installation & operation manual

PrimeVOLT

PrimeVOLT PV T U Series Installation & operation manual

Kaco blueplanet 29.0 TL3 Series manual

Kaco

Kaco blueplanet 29.0 TL3 Series manual

Mitsubishi Electric PV-PNS04ATL-IT Operation manual

Mitsubishi Electric

Mitsubishi Electric PV-PNS04ATL-IT Operation manual

Turbo Energy HYBRID 48V 5.0 Series instruction manual

Turbo Energy

Turbo Energy HYBRID 48V 5.0 Series instruction manual

Autarco XLX20000S Installation and operation manual

Autarco

Autarco XLX20000S Installation and operation manual

MasterPower OMEGA LV Series user manual

MasterPower

MasterPower OMEGA LV Series user manual

SMA 15000TL installation manual

SMA

SMA 15000TL installation manual

opti-solar Sp4000 Premium user manual

opti-solar

opti-solar Sp4000 Premium user manual

Hyundai power products 1500 quick start guide

Hyundai power products

Hyundai power products 1500 quick start guide

Generac Power Systems MEGA 2500 owner's manual

Generac Power Systems

Generac Power Systems MEGA 2500 owner's manual

Innova Filomuro SLW 400 Installation and user manual

Innova

Innova Filomuro SLW 400 Installation and user manual

Viadrus Regusol Series operating manual

Viadrus

Viadrus Regusol Series operating manual

Velleman Instruments PCG10 Reference manual

Velleman Instruments

Velleman Instruments PCG10 Reference manual

SMA Solar Technology STP 15000TL-30 Quick reference guide

SMA Solar Technology

SMA Solar Technology STP 15000TL-30 Quick reference guide

SolarEdge SE K Series installation guide

SolarEdge

SolarEdge SE K Series installation guide

Afore HNS1000TL-1 Installation and operation manual

Afore

Afore HNS1000TL-1 Installation and operation manual

Renogy 500W user manual

Renogy

Renogy 500W user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.