Soltech STL-FLK100PXYYZZ Service manual

INSTALLATION INSTRUCTION MANUAL
LED FLOOD LIGHT,100-277&277-480VAC
Rev AJuly 2017
MODELS:
TLFLK100PXYYZZ;TLFLK100PHXYYZZ;TLFLK150PXYYZZ;FLK150PHXYYZZ;
TLFLK200PXYYZZ;TLFLK230PXYYZZ;TLFLK230PHXYYZZ;TLFLK300PXYYZZ;
TLFLK300PHXYYZZ;TLFLK400PXYYZZ;TLFLK400PHXYYZZ
Model number parameter list:
1. Introduction
This LED Flood light uses the latest in solid state lighting technology for long life, low
maintenance, and high efficiency.
Item Model Input Voltage Power
Factor
Watt Input
Current
Weight
A TLFLK100PXYYZZ 100-277VAC
>0.9
100W 1.5A 5.9Kg
B TLFLK100PHXYYZZ 277-480VAC 100W 0.55A
5.9Kg
C TLFLK150PXYYZZ 100-277VAC 150W 1.8A 6.3Kg
D TLFLK150PHXYYZZ 277-480VAC 150W 0.88A 6.3Kg
E TLFLK200PXYYZZ 100-277VAC 200W 2.5A
6.3Kg
D TLFLK230PXYYZZ 100-277VAC 230W 2.5A 10.1Kg
F TLFLK230PHXYYZZ 277-480VAC 230W 1.4A 10.1Kg
G TLFLK300PXYYZZ 100-277VAC 300W 3.5A
10.1Kg
H TLFLK300PHXYYZZ 277-480VAC 300W 1.8A 10.1Kg
G TLFLK400PXYYZZ 100-277VAC 400W 5.0A 12.7Kg
I TLFLK400PHXYYZZ 277-480VAC 400W 2.8A 12.7Kg
BRACKET
+
+
+
SF
MA
TR
Rev B JAN 2019
13 LBS
13 LBS
13.9 LBS
13.9 LBS
13.9 LBS
22.3 LBS
22.3 LBS
22.3 LBS
22.3 LBS
28 LBS
28 LBS
STL-FLK100PXYYZZ
STL-FLK100PHXYYZZ
STL-FLK150PXYYZZ
STL-FLK150PHXYYZZ
STL-FLK200PXYYZZ
STL-FLK230PXYYZZ
STL-FLK230PHXYYZZ
STL-FLK300PXYYZZ
STL-FLK300PHXYYZZ
STL-FLK400PXYYZZ
STL-FLK400PHXYYZZ
STL-FLK100PXYYZZ; STL-FLK100PHXYYZZ; STL-FLK150PXYYZZ; STL-FLK150PHXYYZZ;
STL-FLK200PXYYZZ; STL-FLK230PXYYZZ; STL-FLK230PHXYYZZ; STL-FLK300PXYYZZ;
STL-FLK300PHXYYZZ; STL-FLK400PXYYZZ; STL-FLK400PHXYYZZ
100–277VAC
100–277VAC
100–277VAC
100–277VAC
100–277VAC
100–277VAC
277–480VAC
277–480VAC
277–480VAC
277–480VAC
277–480VAC
100W
150W
200W
230W
300W
400W
100W
150W
230W
300W
400W
1.5A
1.8A
2.5A
2.5A
3.5A
5.0A
0.55A
0.88A
1.4A
1.8A
2.8A
>0.9
LED Area Light/Flood Light, 100–277&277–480VAC
This LED Area Light/Flood Light uses the latest in solid state lighting technology for long,
life, low maintenance, and high efficiency.
FOR MORE LIGHTING INFO CALL
1460 PARK AVENUE, EMERYVILLE, CA 94608
510.891.1056
HELLO@SOLTECHLIGHTING.COM
SOLTECHLIGHTING.COM
Model number parameter list:
Model:
1. Instruction

The same as traditional HID lighting. There are two installation methods, suitable for various
occasion.
An internal power-factor-corrected switch-mode supply allows it to be used from
any nominal 100-277V&277-480V, 50~60Hz AC supply without any variation in light output.
Suitable for use in the following locations:
•
Ambient Temp: -40~+40°C
•
Wet Locations
Note: Save these instructions for future reference.
2. Installation
For supply connections use wire rated for at least 90°C
Installation Steps:
Refer to the following diagram when you install the fixture. Seven installation methods, directly fix to the
mounting surface or fix to a post with a knuckle.
1.Directly fix to mounting surface
Warning:
To avoid the risk of fire, explosion, or electric shock, this product should be installed,
inspected, and maintained by a qualified electrician only, in accordance with all applicable
electrical codes.
Warning:
To avoid electric shock:
•Be certain electrical power is OFF before and during installation and maintenance.
•Luminaire must be connected to a wiring system with an equipment-grounding conductor.
Warning:
To avoid explosion:
•Make sure the supply voltage is the same as the rated luminaire voltage.
•Do not install where the marked operating temperatures exceed the ignition temperature of
the hazardous atmosphere.
•Do not operate in ambient temperatures above those indicated on the luminaire nameplate.
•Keep lens tightly closed when in operation.
TLFLK100PXYYZZ/TLFLK100PHXYYZZ
TLFLK150PXYYZZ/TLFLK150PHXYYZZ
TLFLK200XYYZZ
TLFLK230PXYYZZ/TLFLK230PHXYYZZ
TLFLK300PXYYZZ/TLFLK300PHXYYZZ
TLFLK400PXYYZZ/TLFLK400PXYYZZ
STL-FLK100PXYYZZ/STL-FLK100PHXYYZZ
STL-FLK150PXYYZZ/STL-FLK150PHXYYZZ
STL-FLK200PXYYZZ
STL-FLK2300PXYYZZ/STL-FLK230PHXYYZZ
STL-FLK300PXYYZZ/STL-FLK300PHXYYZZ
STL-FLK400PXYYZZ/STL-FLK400PHXYYZZ
To avoid the rish of fire, explosion or electric shock, this product should be installed,
inspected, and maintained by a qualified electrician only, in accordance with all applicable
electrical codes.
To avoid electric shock:
- Be certain electrical power is OFF before and during installation and maintanence.
- Luminaire must be connected to a wiring system with an equipment-grounding conductor.
To avoid explosion:
- Make sure the supply voltage is the same as the rated luminaire voltage.
- Do no install where the marked operating temperatures exceed the ignition temperature
of the hazardous atmosphere.
- Do not operate in ambient temperatures above those indicated on the luminaire nameplate.
- Keep lens tightly closed when in operation.
For supply connections use wire rated for at least 90˚C
FOR MORE LIGHTING INFO CALL
1460 PARK AVENUE, EMERYVILLE, CA 94608
510.891.1056
HELLO@SOLTECHLIGHTING.COM
SOLTECHLIGHTING.COM
2. Installation

1.Use expansion bolts to secure the fixture on mounting surface.
2. Keep enough length wires to ensure adjusting angle unhindered.
Connect wires into wiring terminal; white wire to“Neutral”terminal, black wire to“Live”terminal, green wire
to “Ground”terminal; and fix them by screws.
2.Mounting with a Slipfitter for Models:
LFLK100PXYYZZ;TLFLK100PHXYYZZ;TLFL150PXYYZZ;TLFL150PHXYYZZ;TLFLK200PXYYZZ;TLFL230PXYYZZ;
TLFL230PHXYYZZ;TLFL300PXYYZZ;TLFL300PHXYYZZ;TLFL400PXYYZZ;TLFL400PHXYYZZ
Step 1
Adjust the fixture orientation by turning the bolt.In the
above photo for the rocker installation hole, for the sensor
installation hole in the bottom
Step 2
Please use a post of diameter 2.36” for mounting,
and tighten with screws.You can open the side
cover from the side connection
3.Mounting with Arm for Models
TLFLK100PXYYZZ;TLFLK100PHXYYZZ;TLFLK150PXYYZZ;TLFLK150PHXYYZZ;TLFLK200PXYYZZ;TLFLK230PXYYZZ;
TLFLK230PHXYYZZ;TLFLK300PXYYZZ;TLFLK300PHXYYZZ;TLFLK400PXYYZZ;TLFLK400PHXYYZZ.
Directly with the screw on the lamp post.In the above straight arm has a reserved light installation hole, for the sensor
installation hole in the bottom.You can open the side cover from the side connection
4.Wall mounted installation
L(Black)
N(White)
G(Green)
STL-FLK100PXYYZZ; STL-FLK100PHXYYZZ; STL-FLK150PXYYZZ; STL-FLK150PHXYYZZ; STL-FLK200PXYYZZ; STL-FLK230PXYYZZ;
STL-FLK230PHXYYZZ; STL-FLK300PXYYZZ; STL-FLK300PHXYYZZ; STL-FLK400PXYYZZ; STL-FLK400PHXYYZZ
STL-FLK100PXYYZZ; STL-FLK100PHXYYZZ; STL-FLK150PXYYZZ; STL-FLK150PHXYYZZ; STL-FLK200PXYYZZ; STL-FLK230PXYYZZ;
STL-FLK230PHXYYZZ; STL-FLK300PXYYZZ; STL-FLK300PHXYYZZ; STL-FLK400PXYYZZ; STL-FLK400PHXYYZZ
1. Use expansion bolts to secure the fixrure on mounting surface.
2. Keep enough length wires to ensure adjusting angle unhindered.
Connect wires into wiring terminal; white wire to “Neutral” terminal, black wire to “Live” terminal, green wire
to “Ground” terminal; and fix them by screws.
Adjust the fixture orientation by turning the bolt. In the
above photo for the rocker installation hole, for the sensor
installation hole in the bottom
Please use a post of diameter 2.36” for mounting,
and tighten with screws. You can open the side
cover from the side connection
Directly with the screw on the lamp post. In the above straight arm has a reserved light installation hole, for the sensor
installation hole in the bottom. You can open the side cover from the side connection
2. Mounting with a Slipfitter for Models:
3. Mounting with Arm for Models:
FOR MORE LIGHTING INFO CALL
1460 PARK AVENUE, EMERYVILLE, CA 94608
510.891.1056
HELLO@SOLTECHLIGHTING.COM
SOLTECHLIGHTING.COM

TLFLK100PXYYZZ;TLFLK100PHXYYZZ;TLFLK150PXYYZZ;TLFLK150PHXYYZZ; TLFLK200PXYYZZ; TLFLK230PXYYZZ;
TLFLK230PHXYYZZ;TLFLK300PXYYZZ; TLFLK300PHXYYZZ;TLFLK400PXYYZZ;TLFLK400PHXYYZZ.
The mounting method of the straight arm is added to a wall mounted fixing plate, and the fixing plate
is mounted on the wall, and the fixing plate is fixed by a nut.
After installation, please
¾check whether the lighting fixture is firmly fixed.
¾check whether wires are connected correctly.
¾At last, turn on the power, and check if the lighting fixture works well. If not, please turn off the
power and contact with local dealer.
STL-FLK100PXYYZZ; STL-FLK100PHXYYZZ; STL-FLK150PXYYZZ; STL-FLK150PHXYYZZ; STL-FLK200PXYYZZ; STL-FLK230PXYYZZ;
STL-FLK230PHXYYZZ; STL-FLK300PXYYZZ; STL-FLK300PHXYYZZ; STL-FLK400PXYYZZ; STL-FLK400PHXYYZZ
4. Wall Mounted Installation:
The mounting method of the straight arm is added to a wall mounted fixing plate, and the fixing plate is mounted on the wall, and the fixing
plate is fixed by a nut.
FOR MORE LIGHTING INFO CALL
1460 PARK AVENUE, EMERYVILLE, CA 94608
510.891.1056
HELLO@SOLTECHLIGHTING.COM
SOLTECHLIGHTING.COM
This manual suits for next models
10