Sota ZBB4 User manual

© 2000-2018 SOTA Instruments Inc. Page 1 of 13|www.sota.com
The Silver Pulser
Model ZBB4 Manual
CONTENTS
WELCOME TO SOTA..................................................................................................... 3
BEFORE USING ............................................................................................................... 3
LEARN MORE ................................................................................................................. 3
COMPLETE UNIT INCLUDES...................................................................................... 3
DO NOT USE.................................................................................................................... 4
MICROPULSING CAUTIONS ...................................................................................... 4
IONIC~COLLOIDAL SILVER CAUTIONS................................................................. 5
GENERAL CAUTION..................................................................................................... 5
SUMMARY OF LIGHTS ................................................................................................. 5
HOW TO USE THE MICROPULSING FUNCTION .................................................. 6
All Cotton Sleeves Option.......................................................................................... 6
Cotton Sleeves with Velcro®Option......................................................................... 7
Turning the Unit On ................................................................................................... 7
How Micropulsing Should Feel ............................................................................... 8
Sensitive Skin ............................................................................................................... 9
Typical Use .................................................................................................................. 9
HOW TO USE THE IONIC~COLLOIDAL SILVER FUNCTION ......................... 10
How to Assemble ...................................................................................................... 10
How to Make Ionic~Colloidal Silver...................................................................... 10
Typical Use................................................................................................................. 12

© 2000-2018 SOTA Instruments Inc. Page 2 of 13|www.sota.com
The Silver Pulser Model ZBB4 Manual
ELECTRICAL SPECIFICATIONS .............................................................................. 12
Power Requirements................................................................................................. 12
Optional Power Input............................................................................................... 12
Output Specications................................................................................................ 13
REPLACEMENT ACCESSORIES................................................................................ 13
WARRANTY................................................................................................................... 13
REPAIRS.......................................................................................................................... 13

© 2000-2018 SOTA Instruments Inc. Page 3 of 13|www.sota.com
The Silver Pulser Model ZBB4 Manual
WELCOME TO SOTA
Thank you for allowing us to be a part of your Wellness Team.
The Silver Pulser is a consumer product designed to be used as part of a Wellness
Lifestyle. A commitment to healthy lifestyle choices is an important factor in the
journey to Wellness.
The SOTA Silver Pulser offers the benets of gentle microcurrents of electricity and
also makes Ionic~Colloidal Silver. Microcurrent stimulation supports the body’s own
natural electricity for more energy, health and well-being. Ionic~Colloidal Silver
supports the body’s natural defenses.
The Silver Pulser is designed to be used independently, but can also be used together
with any of the SOTA Products.
With proper care, your Silver Pulser should provide you many years of trouble-free
use.
Please understand that results will vary.
BEFORE USING
Please read this manual thoroughly before using your Silver Pulser.
Please note information in this manual is subject to change.
For the most up-to-date manual, please visit our website www.sota.com/manuals.
LEARN MORE
To learn more about the Silver Pulser we invite
you to visit the SOTA website:
www.sota.com
The website offers How to Videos, Frequently
Asked Questions, The SOTA Products User
Guide, SOTA News ... and more.
COMPLETE UNIT INCLUDES
• One (1) Silver Pulser Unit
• One (1) 9-Volt Alkaline Battery
• One (1) Product Manual

© 2000-2018 SOTA Instruments Inc. Page 4 of 13|www.sota.com
The Silver Pulser Model ZBB4 Manual
FOR MICROPULSING APPLICATION:
• One (1) Micropulsing Cord
• One (1) Neoprene®Velcro®Wrist Strap
• One (1) 50 ml Dark Glass Dropper Bottle
ALL COTTON SLEEVES OPTION
• Three (3) Pair All Cotton Sleeves
COTTON SLEEVES WITH VELCRO® OPTION
• Six (6) Pair Cotton Sleeves with Velcro®
FOR MAKING IONIC~COLLOIDAL SILVER:
• One (1) Silver Wire Holder
• Two (2) Silver Wires of .9999 (4 Nine) Purity
• One (1) Green Scrub Pad
DO NOT USE
1.In the following situations as safety has not been explored using the Micropulsing
function:
a. In the case of pregnancy.
b. With an active implanted device such as a pacemaker, etc.
2.As with all electrical products do not use near water, when driving a car or when
operating heavy equipment.
MICROPULSING CAUTIONS
1.Do not place the Micropulsing Probes over skin lesions, abrasions, new scars, cuts,
eruptions or sunburn.
2.Caution is advised if using potentially harmful substances such as recreational and
prescription drugs, as it is not known if microcurrents will interact or if individual
reactions may occur.
3.Caution is required in the following situations as a burn may occur, which could
scar:
a. Do not apply the bare metal pins to the skin.
b. Allowing the Cotton Sleeves to dry out while Micropulsing.
c. Sleeping while Micropulsing, as the Cotton Sleeves may dry out.

© 2000-2018 SOTA Instruments Inc. Page 5 of 13|www.sota.com
The Silver Pulser Model ZBB4 Manual
IONIC~COLLOIDAL SILVER CAUTIONS
1.We recommend taking occasional breaks from consuming Ionic~Colloidal Silver for
the following two reasons:
a. Growth of healthy bacteria in the gut may be slowed. It may be wise to
supplement with a probiotic (friendly bacteria) to replenish the gut from time to
time.
b. A handful of people have experienced argyria after drinking large amounts of
Ionic~Colloidal Silver daily, over a long period of time. Argyria is a bluish tinge
of the skin. This occurs when excess silver is eliminated through the skin and
exposed to light. Darkening of the moons of the nger nails is usually an early
sign.
The risk of argyria is considered greater for those who are ingesting incorrectly
made Ionic~Colloidal Silver and to a lesser degree, those who are decient in
selenium or vitamin E.
When making and drinking Ionic~Colloidal Silver as currently recommended by
SOTA, the risk of argyria is extremely rare. Please see www.sota.com/manuals.
GENERAL CAUTION
While this technology is generally considered safe, there exists potential for rare
individual reactions that cannot reasonably be foreseen. Therefore, your use of the
SOTA Products constitutes your agreement that you are responsible for your decision
to use the technology.
SUMMARY OF LIGHTS
Left GREEN: Flashes alternately with left RED light to indicate Micropulsing function
is ready for use.
Left RED: Flashes alternately with left GREEN light to indicate Micropulsing function
is ready for use.
To save batteries, the GREEN and RED lights on the left will not ash when
Micropulsing cord is plugged into the unit. They will continue to ash, however,
when making Ionic~Colloidal Silver.
Right GREEN: Solid light indicates Ionic~Colloidal Silver function is working.
Right RED: Solid light indicates impurities in the water or that the wires are touching
when making Ionic~Colloidal Silver.

© 2000-2018 SOTA Instruments Inc. Page 6 of 13|www.sota.com
The Silver Pulser Model ZBB4 Manual
HOW TO USE THE MICROPULSING FUNCTION
1.Place the 9-Volt Alkaline battery in the unit.
a. On the back of the unit, slide off the battery cover.
b. Attach the positive (+) and negative (-) terminals on the 9-Volt Alkaline battery to
the positive (+) and negative (-) clips in the battery compartment.
c. Slide the 9-Volt Alkaline battery into the case and push down. Slide the cover back
onto the unit.
2.Clean the wrist area to remove oils from the skin. This will allow for better
conductivity.
3.Insert the Micropulsing Cord into the jack on the unit.
4.Slide the unit into the arm strap.
5. Slide the unit and the Cord up the arm to a comfortable position. Tighten the band to
secure it in place.
Option: If preferred, the unit can be placed in a pocket. A longer Micropulsing Cord
is needed for this option.
ALL COTTON SLEEVES OPTION
6.Prepare one pair of Cotton Sleeves. Each Cotton Sleeve is
sewn on three sides; to nd the open end of the Cotton
Sleeve, squeeze the long sides of the sleeve and the unsewn
end will pop open.
7.Insert one probe from the Micropulsing Cord into the open
end of each Cotton Sleeve. Use a gentle twisting motion to
work the probes into the Cotton Sleeves.
8.Wet the Cotton Sleeves with water.
9.Put the Wrist Strap on.
10. Position one of the covered probes over the pulse point on
the thumb side of the wrist, under the Wrist Strap.
11.Place the other covered probe in line with the pulse point on the little nger side of
the wrist. This pulse point is usually harder to feel. It is located in the soft hollow
on the wrist, in line with the little nger.
1

© 2000-2018 SOTA Instruments Inc. Page 7 of 13|www.sota.com
The Silver Pulser Model ZBB4 Manual
COTTON SLEEVES WITH VELCRO®OPTION
6. Put the Wrist Strap on with the Velcro®side of the Wrist
Strap face-out rather than towards the skin.
Prepare one pair of Cotton Sleeves. Each Cotton Sleeve
is sewn on three sides; to nd the open end of the Cotton
Sleeve, squeeze the long sides of the sleeve and the unsewn
end will pop open.
7. Attach one Cotton Sleeve to the Wrist Strap in line with
the pulse point on the thumb side of the wrist. The open end
of the Cotton Sleeve will point down toward the elbow. Press
the sleeve to the Wrist Strap to rmly adhere the sleeve in
place.
Place the other Cotton Sleeve, again with the open side
towards the elbow, in line with the pulse point on the little nger side of the wrist.
This pulse point is usually harder to feel. It is located in the soft hollow on the wrist,
in line with the little nger. Press the sleeve to the Wrist Strap to rmly adhere the
sleeve in place. See image 2.
Once in place, the Velcro®will hold the Cotton Sleeves in the right position for
repeated use.
8.Take the Wrist Strap off.
9.Insert one probe from the Micropulsing Cord into each of the Cotton Sleeves. Use a
gentle twisting motion to work the probes into the Cotton Sleeves.
10.Wet the Cotton Sleeves with water.
11.Put the Wrist Strap on so the damp Cotton Sleeves are against the skin over the
pulse points. See image 1.
TURNING THE UNIT ON
12.Turn the unit ON by rotating the thumbwheel switch clockwise. Turn the switch
slowly until you feel the current. If you do not feel the current, see Notes below.
When the Micropulsing Cord is plugged into the unit, the ashing GREEN and
RED lights will not be on. This helps conserve the battery.
13.When nished, turn unit OFF by rotating the thumbwheel switch fully counter-
clockwise until it clicks. Do not force the ON/OFF knob past its natural stopping
point.
2

© 2000-2018 SOTA Instruments Inc. Page 8 of 13|www.sota.com
The Silver Pulser Model ZBB4 Manual
14.Clean the wrist and apply a healing
lotion to avoid irritation.
Notes:
Suggestions for Feeling the Current: If
the current is not felt with wet Cotton
Sleeves, prepare a mild salt solution to
wet the sleeves. Add a few grains of salt
to the water in the 50 ml dropper bottle.
Alternatively, a conductive gel or aloe
vera gel may be used instead of a salt
solution. Drink enough water to keep
the body well hydrated. The level of
hydration may affect sensitivity.
Care of Micropulsing Cord: Discoloration of probes is normal. Buff occasionally to
remove stains to ensure good electrical contact.
Care of Cotton Sleeves: Wash or rinse sleeves occasionally. Discard and replace
Cotton Sleeves periodically.
Alternatives to Cotton Sleeves: The following items can be used in place of the
Cotton Sleeves:
a. Unbleached Paper Towel: Cut a small square of paper towel large enough to wrap
around the probe 2 or 3 times. Moisten prior to use.
b. Cotton Flannel: Cut a small square of cotton annel and wrap around the probe
with thread. Moisten prior to use.
Testing the Micropulsing Function: Unplug the Micropulsing Cord with the unit
on. The GREEN and RED lights on the left side of the unit should ash alternately. If
lights do not ash, check battery. If lights still do not ash, contact your supplier or
your closest repair depot. See ‘Repairs’ on page 13.
Power Supply: When Micropulsing, as a safety feature, the unit can only be powered
by a 9-Volt battery.
HOW MICROPULSING SHOULD FEEL
1. The sensation is a gentle pulsing. While the microcurrents should be felt, it is not
necessary to turn the intensity control up to an uncomfortable level.

© 2000-2018 SOTA Instruments Inc. Page 9 of 13|www.sota.com
The Silver Pulser Model ZBB4 Manual
2. With repeated use, the ability to feel the microcurrents may change. It may be
necessary to increase the intensity in order to feel the microcurrents.
3. Twitching of the ngers is normal at a higher intensity.
4. During the rst weeks of use, the skin may become irritated. Over time, irritation
usually decreases or disappears. Alternating wrists each session allows any
irritation to better heal.
SENSITIVE SKIN
Some individuals may be particularly sensitive to microcurrents and the irritation may
continue. To minimize irritation:
1. Wash wrists thoroughly after each session and apply a healing gel or lotion such
as aloe vera, vitamin E or MSM cream.
2. Micropulse for shorter periods of time until the irritation disappears.
3. Alternate wrists daily.
4. Wet the Cotton Sleeves with distilled water or Ionic~Colloidal Silver. The silver
electrolyte has a healing effect. If unable to feel the current, try a commercial saline
solution for the eyes. This is gentler than adding salt to the water.
5. A conductive gel or aloe vera gel added to the wet sleeves may help to reduce
irritation.
6. Another option is to wrap a small square of paper towel around the probes instead
of using Cotton Sleeves. Keep the paper well moistened. A small square of paper
towel may last for several applications. If available, use unbleached paper towel.
7. Set the intensity dial to a comfortable level.
TYPICAL USE
Alternate wrists daily.
Length of Session: Build up time gradually. It is best to start slowly. Start with 10 to
20 minutes a day. Increase gradually to a minimum of 2 hours each day.
Length of Use: Use daily for a minimum of 8 to 12 weeks. Once completed, setting a
schedule for ongoing use is benecial. Suggestions for a maintenance schedule are a)
1 to 3 times per week, b) 1 week per month, or as needed. The initial program can be
repeated at any time.

© 2000-2018 SOTA Instruments Inc. Page 10 of 13|www.sota.com
The Silver Pulser Model ZBB4 Manual
Drink Plenty of Water: It’s important to drink enough water when using the unit.
Drinking ozonated water is especially helpful.
Stop Gradually: Reduce the amount of time each day for the last week of use. If
using the 4-part SOTA Protocol, it is suggested to stop only one part of the protocol
at a time.
HOW TO USE THE IONIC~COLLOIDAL SILVER FUNCTION
HOW TO ASSEMBLE
1.The Silver Wires t into the two small holes in the Silver
Wire Holder.
2.To insert the Silver Wires, move the spring clip away
from the hole to allow the wire to slide in smoothly.
a. Insert as in the picture. Push the wire through. Most
of the wire should be below the holder. It may be
easier to insert from the underside of the holder.
b. Release the clip to hold the Silver Wire snuggly in
place.
3.Repeat the above steps for the second Silver Wire and plug the Silver Wire Holder
into the Silver Pulser.
HOW TO MAKE IONIC~COLLOIDAL SILVER
1.Heat 2 cups (500 ml) of distilled water to the boiling
point—preferably in a non–metal container. Do not
use a glass measuring cup on the stove top as it may
explode.
2.Use a heat-resistant glass container to make
Ionic~Colloidal Silver.
3.Place the Silver Wire Holder on the glass container
immersing the Silver Wires. Keep them at least 25 mm
or 1 inch from the bottom of the container.
4.Turn the unit ON by rotating the thumbwheel switch
clockwise, until it clicks. It is not necessary to turn up
the intensity.
When the Silver Wire Holder is plugged into the unit, the GREEN light on the

© 2000-2018 SOTA Instruments Inc. Page 11 of 13|www.sota.com
The Silver Pulser Model ZBB4 Manual
right side of the unit will come on steady. The lights on the left side of the unit
will continue to ash.
5.Stir occasionally with a non-metal utensil. Occasionally, wipe off the grey or black
silver oxide that builds up on the Silver Wires.
6.Two cups (16 ounces or 500 ml) for 15 minutes will produce a 3 to 5 ppm batch of
Ionic~Colloidal Silver, depending on the brand of distilled water. The concentration
of silver is measured in parts per million or ppm.
7.When nished, wipe the Silver Wires with paper towel to remove residue. Buff
lightly when needed to keep them free of sediment. Harsher bufng will wear away
the silver faster.
Notes:
Impurities: If the RED light on the right side of the unit comes on while making
Ionic~Colloidal Silver, it means there are too many impurities in the water. Try a
different brand of distilled water. The RED light also comes on if the two wires are
touching.
Color: Ionic~Colloidal Silver remains colorless to about 5 or 6 ppm. At a slightly
higher ppm it will be a pale gold color. Do not drink if it is darker than pale gold or
dark grey as this indicates a higher level of impurities or larger particle sizes.
Clarity: The electrolyte should be clear. Do not drink if it is cloudy.
Storage: Pour the Ionic~Colloidal Silver into a dark glass bottle—never metal—and
store in a dark, dry place. Over time, light will degrade Ionic~Colloidal Silver by
turning the electrolyte grey or black.
When made and stored properly, Ionic~Colloidal Silver retains freshness for many
weeks. It is suggested, however, that you use as soon as possible. If settling occurs, it
is losing potency. Do not drink any sediment.
Do not freeze, refrigerate, or expose Ionic~Colloidal Silver to extremes of
temperatures as its potency may be affected.
Save on Batteries: The unit can be powered by an AC-DC wall adaptor when
making Ionic~Colloidal Silver. See ‘Optional Power Input’ below.
Switch Silver Wire Positions: The silver ions only come off the wire in the positive
(+) or anode terminal into the water. To equalize the wearing of the Silver Wires,
exchange the position of the wires after each use. If left in the same position, only one

© 2000-2018 SOTA Instruments Inc. Page 12 of 13|www.sota.com
The Silver Pulser Model ZBB4 Manual
Silver Wire will gradually wear away.
Replacing the Silver Wires: The Silver Wires are of the highest grade .9999 or 99.99%
or 4 Nine pure ne silver. When the SOTA pure Silver Wires wear too thin, do not
replace with sterling silver, as it contains nickel, which can be toxic.
TYPICAL USE
Quantity: There is no denite amount to drink. When consumed on a regular basis—
daily or several times a week—it is best to drink no more than 1 to 2 ounces (30 to 60
ml) at a time.
Larger amounts of Ionic~Colloidal Silver—1 cup or more—can be consumed for
short periods of time, for example, a few weeks. It is better to take smaller amounts
throughout the day rather than all at once.
Length of Use: 1 to 2 ounces (30 to 60 ml) or more daily for 2 or 3 months.
Ionic~Colloidal Silver can be used as needed. The initial program can be repeated at
any time. If using for an extended period, it is wise to take breaks.
Strength: Laboratory testing indicates Ionic~Colloidal Silver is effective as low as 2
ppm. When ingesting on a regular basis, it is suggested to limit the strength to less
than 10 ppm.
ELECTRICAL SPECIFICATIONS
POWER REQUIREMENTS
Use a 9–Volt Alkaline battery for proper operation.
OPTIONAL POWER INPUT
Both functions of the Silver Pulser can also be operated using NiMH rechargeable
batteries. When purchasing rechargeable batteries, it is suggested to take the unit
with you to ensure the batteries will t the enclosure.
To use a wall adaptor for making Ionic~Colloidal Silver the output should be from
6 to 12 Volts DC with a Tip or Center Positive pin and a minimum of 500 mA
(milliamperes) of current. The wall adaptor that comes with other SOTA units can be
used for making Ionic~Colloidal Silver.
Caution: Exceeding the voltage rating or reverse connection may result in injury
or unit failure. This will void the warranty.
To operate the Ionic~Colloidal Silver Function from a 12 Volt DC source, such as an

• The SOTA units are consumer products designed to be used as part of a Wellness Lifestyle • The SOTA units are not medical devices nor are they
intended to diagnose, treat or cure any medical or health condition • The use, safety or effectiveness of the SOTA units has not been approved by any
government agency • Please consult a health practitioner for any medical or health condition • Results using the SOTA Products will vary for each
person • Please note that all purchases of SOTA Products are deemed to be made in Penticton, BC, Canada •
© 2000-2018 SOTA Instruments Inc. Page 13 of 13 |www.sota.com
Designed, Engineered and Made in Canada.
The Silver Pulser Model ZBB4 Manual
automobile battery or an appropriate Solar Panel, purchase a Universal Power Cord
with Tip or Center Positive.
OUTPUT SPECIFICATIONS
The output voltage is a nominal 31 Volts.
Micropulsing Application: Frequency through probes is ~3.92 Hz or ½ of the Earth
Schumann frequency of 7.83 Hz, (+/- 1 Hz) with a Bi-Phasic Square Wave @ 31 Volts
(+/- 1 Volt) peak per cycle.
Maximum current through the probes is ~8 milliamperes into 1,000 ohms, ~12
milliamperes into a short circuit at 31 Volts peak per cycle.
Ionic~Colloidal Silver Application: The maximum current through the Silver Wires
is 40 milliamperes (+/- 0.5 mA) at 31 VDC compliance voltage when the Silver Wires
are touched together to short the circuit.
REPLACEMENT ACCESSORIES
To replace your accessories, please contact your supplier.
WARRANTY
The Silver Pulser Model ZBB4 covered by a three (3) year limited warranty. Please
keep proof of purchase. Warranty is void if the failure is due to abuse or negligence.
SOTA reserves the right to make changes to the Silver Pulser without obligation.
REPAIRS
Please contact your supplier for return instructions. For information about your closest
USA) or 1.250.770.2023.
Table of contents
Other Sota Medical Equipment manuals

Sota
Sota Magnetic Pulser User manual

Sota
Sota Bio Tuner BT8 User manual

Sota
Sota Magnetic Pulser MP6 Operating instructions

Sota
Sota LightWorks LW1 Operating instructions

Sota
Sota SP5 User manual

Sota
Sota ZBB1 User manual

Sota
Sota BT6pro User manual

Sota
Sota Bio-Tuner BT7 User manual

Sota
Sota LightWorks LW2 User manual
Popular Medical Equipment manuals by other brands

Cognivue
Cognivue Thrive UM-420-T user manual

Bodypoint
Bodypoint Ankle Huggers Installation and user instructions

Omron
Omron Colin VP-1000 plus manual

Boston Scientific
Boston Scientific AMS 700 user guide

Teufel
Teufel TKS user manual

SSCOR
SSCOR S-SCORT III 74000 Operating Instructions & Maintenance Manual