SRM High Performance Ergometer How to use

Short Manual
SRM - Ergometer

Short Manual SRM –Ergometer
2
Table of Contents
1General preparation ........................................ 3
2Einstellung USB/Seriell Adapter im Active Port............. 3
3Settings Powercontrol IV ................................. 5
SRMWin-Software: On menu bar choose PC IV (Drop-
down)....................................................................................... 5
SRMWin-Software: Powercontrol –Setup ...................... 5
Verify slope (Slope of PowerMeter) ................................ 7
Verify Zero Offset ............................................................ 8
4SRM Online-Mode ......................................... 10
5Client / Test person ...................................... 11
6Settings SRM - Ergometer ............................. 12
Bike fitting: transfer settings of client’s own bike to the
sitting position....................................................................... 13
7Warm-up..................................................... 14
8Setup of test protocol ................................... 15
9Start performance diagnostics........................ 16
10 End of the test ............................................. 17
11 Service........................................................ 18
12 FAQ ............................................................ 18

Short Manual SRM –Ergometer
3
1 General preparation
•Power-on spiroergometry (30min before
beginning of test)
•Power-on ergometer’s power supply
•Preparation diagnostic devices (Lactate
analysis, etc.) 30min beginning of test
•Room temperature (18 –24°C) should
measured
•Relative air humidity should measure (30 –
60%) in room
•Check position of ventilator
2 Settings USB/Serial Converter
The installation of the of USB/Serial Converter
is mandatory for the data recording
Check the activation of the USB/Serial
Converter at the Active port ("SRM
Downloadcable USB")
We recommend the use of the following
USB/Serial Converter:
ATEN USB-to-Serial-(RS 232)Converter,
(Model: UC-232A), (Windows 7)
Plugable USB to RS-232 D89 Serial Adatper,
(Windows 8)

Short Manual SRM –Ergometer
4

Short Manual SRM –Ergometer
5
3 Settings Powercontrol IV
SRMWin-Software: On menu bar choose PC IV
(Drop-down)
SRMWin-Software: Powercontrol –Setup

Short Manual SRM –Ergometer
6
Interval of storage: 1 second
Slope of Powermeter: see ,,Verify Slop”
(page 5)
Circumference of tire: 1000 mm

Short Manual SRM –Ergometer
7
Verify slope (Slope of PowerMeter)
Verify the slope before every test-day.
The slope in the PowerControl and in the
SRMWin-Software should correspond to the slope
of the PowerMeter.
You can find the correct PowerMeter slope
located-at:
1. little sticker at the rear of the PowerMeter
2. on the handlebar or on the front of the
ergometer

Short Manual SRM –Ergometer
8
Verify Zero Offset
Push, simultaneously,
MODE and SET to
switch the
PowerMeter’s display
to calibration mode
For a manual
comparison turn the
unloaded crank in a
clockwise direction to
switch the PowerMeter
on.
Wait a few seconds
until the value
stabilizes on the right
side of the display.
Press SET to apply
the Zero Offset.
(MANU) Value of Pro
will be taken
automatically and is
important for the
measurement.

Short Manual SRM –Ergometer
9
Verify memory capacity and charge of
battery of the PowerControl
PowerControl: Push simultaneously MODE
and PRO
If the memory capacity is full clear
memory by:
SRMWin-Software –Powercontrol –
Setup –Clear memory

Short Manual SRM –Ergometer
10
4 SRM Online-Mode
Change to the online mode by clicking on
the icon ergometer

Short Manual SRM –Ergometer
11
•Data storing of the SRM to automatically
save test data at the end of the test
SRM –ergometer - software: Options –
Extra –At Testend –Save Data –on
Click on Apply to save your settings
5 Client / Test person
•Welcoming
•Clients prepare for test - put on the
heartrate strap
•Documentation of personal data of client
(height, weight, etc.)
•Completion questionnaire / exclusion of
liability
•Discussion of the data and test procedure

Short Manual SRM –Ergometer
12
6 Settings SRM - Ergometer
•Verify gear (gear 9 red point
corresponding)
•Mount client’s pedals
•Crank length set-up:
Recommendation: if possible use same
crank length as on client’s bicycle
Please consider maximum torque of the
crank 10Nm

Short Manual SRM –Ergometer
13
Bike fitting: transfer settings of client’s own
bike to the sitting position
Saddle height
The heel with the
extended leg
should reach the
lowest position in
the pedaling cycle.
Saddle setback
In the horizontal
position of the
crank the knee
(patella) should be
perpendicular to
the pedals axle.

Short Manual SRM –Ergometer
14
7 Warm-up
•Recommendation of at least 3 - 4 min with
a low workload (e.g. 75-100W)
predefined warm-up
•Check the correct settings for:
-Heartrate
-Cadence
-Power
-Speed

Short Manual SRM –Ergometer
15
8 Setup of test protocol
•Determine the test protocol
SRM –ergometer - software: Options -
Mode
Start Test by: Start Button or cadence
Ergometer Mode: Predefined File
Stop Test by: End Button or no cadence
Training File: Open –select the correct
test –OK

Short Manual SRM –Ergometer
16
9 Start performance diagnostics
•Start by beginning to pedal or pushing the
Start Button
•Check the values displayed on the
computer screen

Short Manual SRM –Ergometer
17
10 End of the test
•Stop the test
SRM - ergometer - software: hit “Brake is
on” button (continous recording of the
heartrate - client can continue pedaling
without resistance and cool down)
or
SRM –ergometer - software: End Button
Comment: entry file name then press Save
•Recommended cool –down - protocol with
lower workload
Clean the ergometer (!)

Short Manual SRM –Ergometer
18
11 Service
Recommendation:
crank: send in for service every two years
ergometer: send in for service every four
years
12 FAQ
1. Could not found PowerControl at Computer
check that the USB Driver is correctly
installed and working
make sure the correct USB cable is
selected (see page 3)
check PowerControl IV settings (see page
5)
2. No resistance from ergometer
check speed
check ‘Brake is on’
check PowerControl Cadence, Power
check slope, zero offset, circumference
(see page 6)
check power supply (green light)

Short Manual SRM –Ergometer
19
Contact person:
Mirco Smerecnik
Support SRM Ergometer
SRM Performance Center
Rudolf-Schulten-Str. 6
52428 Jülich
Germany
mobile: +49 (0)176 28 08 81 95
eMail: m[email protected]
skype: mirco.smerecnik
www.srm.de
Other manuals for High Performance Ergometer
1
Table of contents
Other SRM Measuring Instrument manuals