3
Siedle In-Home: Audio
„Single line“
Conguration
The In-Home bus: The Audio system
comprises a bus installation with a
two-core line permitting the con-
nection of up to 31 users, e.g.
bus telephones, handsfree bus
telephones, door stations or devices
for switching and control functions.
Technically speaking, one device can
occupy more than one user.
The line has its own bus line rectier
for central functions such as speech,
door release or light switching. The
two cores assume the dual func-
tions of power supply and also
transmission of audio, switching
and control signals. Junction points
and branches are admissible at any
optional position in the line. In order
to connect more than 31 users, sev-
eral Siedle In-Home: Audio lines can
be interconnected.
Installation and programming
In their as-delivered status, the
devices are initially unprogrammed.
After the bus line rectier is switched
on for the rst time, each of the
connected devices is assigned to a
unique address on the line.
Once installation is complete, a
mutual „teach-in“ process between
all the devices must be performed to
ensure that functions are correctly
executed (e.g. the bus telephone
rings as soon as the call button is
pressed).
Siedle In-Home: Audio
„Multiple line“
Conguration
In-Home: Audio „Single line“ is
restricted to 31 users; In order to
connect more than 31 users, up to
15 lines can be coupled together.
Each line requires its own bus
line rectier. Junction points and
branches are admissible at any
optional position in the line.
Installation and programming
To couple lines together, the bus line
rectiers are linked by means of two
separate cores. Different addresses
must be set at the bus line rectiers
using the “Adr.” rotary switch.
The bus supply unit accessory
ZBVG 650-... must be plugged into
one of the bus line rectiers within
the system.
Then proceed using the same
method as for the In-Home: Audio
single line system.
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualied
electrician. Failure to observe this
regulation could result in the risk of
serious damage to health or fatal
injury due to electric shocks.
When working at the device,
observe the remarks relating to
mains cut-off.
• Observe the DIN EN 60065
standard! When establishing the
electronic connection, observe the
requirements of VDE 0805 or
EN 60950.
• The building installation must
include an all-pole mains switch
with a contact separation of at least
3mm.
• Ensure maximum fusing of 16A for
the mains connection in the building
installation.
• When planning large-scale
(complex) systems, the distributor
space required for the switch panel
mounting devices must be taken
into consideration in the distributor
planning process.
• No external voltages >30 V AC/DC
may be applied to bus users.
Devices with 230 V connection
In accordance with DIN VDE 0100
part 410, section 411.1.3 atten-
tion must be paid to ensuring a
safe separation between bus lines
and the mains voltage; i.e. bus and
mains cores must not be permitted
to touch! The bus line cable (extra-
low safety voltage) must be stripped
back by the minimum possible.
1 In-Home bus: Audio
System description
2 Safety remarks
Danger