Application
Line rectier in switch panel housing
for 1+n technology, and for power
supply to supplementary compo-
nents. Inclusive of function LEDs.
Duplex speech operation between
the door loudspeaker and in-house
telephones. Power supply for call,
speech and door release operation
as well as illumination of call but-
tons.
Application
The line rectier may only be used
exclusively to supply Siedle appli-
ances. Any other application is
deemed not in accordance with its
intended use and exonerates the
manufacturer from any liability.
Electrical voltage
• Mounting, installation and ser-
vicing work on electrical devices may
only be performed by a suitably
qualied electrician.
Failure to observe this regulation
could result in the risk of serious
damage to health or fatal injury due
to electric shocks.
• Operation at an altitude of up to
2000m above sea level.
• Observe EN 62368-1!
In a building installation, an all-
pole mains switch with a contact
opening of at least 3mm must be
provided. The device must not be
exposed to water drops or sprayed
water! Sufcient ventilation must be
ensured. Pay particular attention to
ensure that ventilation slots are not
covered.
• When using stranded cores as
cable material, these must be tted
with wire end ferrules without fail.
Scope of supply
NG602-… comprising:
• Line rectier for top hat rail
mounting
• Siedle 1+n system manual
• This product information
English
Mounting
1 Clip the line rectier onto the top
hat rail.
Installation and commissioning
Installation and commissioning pro-
cedures are described in the system
manual 1+n technology (enclosed
with line rectier NG602-…).
Terminal assignment
N, L1 Power connection
+, - Voltage 23.3VDC
b, c Voltage 12VAC
Specications NG 602-01
Operating voltage:
230VAC, +/-10%, 50/60Hz
Operating current: 200mA
Output voltage: 23.3VDC, 12VAC
Output current: 0.3ADC, 1.6AAC
Fusing: primary Si1 T 200mAL,
secondary side with thermal fuse
Protection system: IP20
Ambient temperature:
0°Cto+40°C
Horizontal pitch (HP): 6
Dimensions (mm) WxHxD:
107x89x60
Specications NG 602-1
Operating voltage:
125VAC, +/-10%, 50/60Hz
Operating current: 370mA
Output voltage: 23.3VDC, 12VAC
Output current: 0.3ADC, 1.6AAC
Fusing: primary Si1 T 400mAL, sec-
ondary, Si2 T0,8AL, Si3 T1,6AL
Protection system: IP20
Ambient temperature:
0°Cto+40°C
Horizontal pitch (HP): 6
Dimensions (mm) WxHxD:
107x89x60
Remedying faults
After a short circuit or overload:
• Remedy the fault
• Check the primary fuse
• Restore the mains power
Application
Bloc d’alimentation pour montage
au tableau de distribution, pour la
technique 1+n, de même que pour
alimenter des composants complé-
mentaires. Avec LED de fonction.
Interphonie entre platine de rue et
combinés intérieurs. Alimentation
électrique pour le mode appeler,
parler et gâche, et éclairage des
touches d’appel.
Domaine d’application
Le bloc d’alimentation doit être
utilisé exclusivement pour alimenter
la technique de Siedle. Toute autre
utilisation est considérée comme
étant non conforme aux ns pour
lesquelles il a été conçu, la responsa-
bilité du fabricant ne pouvant alors
être engagée.
Tension électrique
• L’installation, le montage et l’en-
tretien d’appareils électriques ne
doivent être réalisés que par un spé-
cialiste en électricité.
Le fait de ne pas respecter cette
consigne expose à un risque de bles-
sures graves ou à un danger de mort
par décharges électriques.
• Exploitation à une altitude allant
jusqu’à 2000m au-dessus du
niveau de la mer.
• Respecter la norme EN 62368-1!
Un interrupteur général bipolaire,
avec une distance de contact ouvert
de 3mm au minimum, doit être pré-
sent dans l’installation du bâtiment.
L’appareil ne doit pas être exposé
aux gouttes d’eau ou aux projections
d’eau! Prévoir une ventilation suf-
sante et veiller en particulier à ne pas
masquer les fentes d’aération.
• Si l’on utilise des torons à titre de
câbles, ceux-ci doivent impérative-
ment être munis d’embouts.
Français