Stack Clubman ST200 User manual

Stack Clubman Tachometer
(Model ST200)
Important Note
Your Tachometer is delivered in demonstration mode.
If you have not set the cylinders the tachometer will
automatically start running when you connect the Power.
Mounting
Fits 80mm (2.25”) cut out. Insert in hole, fit
U bracket and tighten down Nyloc nuts.
Note this Tachometer does not require
any protection against vibration.
Connections
RedRed
RedRed
Red wire to a switched 12V supply.
e.g. Ignition switch (Kill Switch on competition vehicles).
BlackBlack
BlackBlack
Black wire to the battery negative or to the
same ground connection as the ignition
system.
OrangeOrange
OrangeOrange
Orange wire to the appropriate tachometer
signal pickup point.
Refer to table on following page
BlueBlue
BlueBlue
Blue wire to one terminal of the switch, and
the other side of the switch to a convenient
groundpoint(Black).
Black
Red
Blue
Orange
Black
Maintenance
The tachometer is sealed to IP67 and requires zero maintenance - there are no wearing
or consumable parts. Removal of the rear can will invalidate your warranty.
Please complete and fax us the enclosed warranty form to ensure you will enjoy a
fast and efficient service in the unlikely event you suffer problems with your unit.
Troubleshooting
If you have problems with the operation of the tachometer then please check the follow-
ing:
1. Recheck all electrical connections.
2. If the back-light doesn’t work check power and ground connections.
3. If the back-light is on but the tachometer doesn’t work check that the pickup wire is
connected correctly to the ignition system (see table on page 2).
Note that certain ignition systems provide a very low voltage Tacho output and
may require a signal amplifier (ST492)
4. Tell tale not working. Check switch wiring and ground connection.
5. If the tachometer shows a constant RPM, check the switch is not shorting out.
6. If the reading is erratic check the following:
That the pickup connection is OK.
Check for possible Points bounce, float or poor ignition grounding.
Check Tachometer ground is the same as ignition system.
7. Tachometer reading too high or too low.
Check the cylinders set up is correct
Specifications
Power: 8v to 18v DC 0.3A Max (Reverse Battery protected)
Operating Temperature: -20 to +70 deg C (0 to 160 Deg F)
Storage Temperature: -40 to +80 deg C (-20 to 175 Deg F
Vibration: 30G50to2000cps12Hr 3axis(36Hr)
Accuracy: +/- 0.45% of Full Scale
Resolution: 25rpm(onexpandedscale)
Shift Light Output 200mA maximum current sink (switched to battery negative)
PP
PP
Perer
erer
ermanent damage will result if this is exceededmanent damage will result if this is exceeded
manent damage will result if this is exceededmanent damage will result if this is exceeded
manent damage will result if this is exceeded
Stack Ltd
Wedgwood Road
Bicester
Oxon OX26 4UL
UK
Tel: ++(0)1869 240404
Fax: ++(0)1869 245500
Email:sales@stackltd.com
Web:www.stackltd.com
Stack Inc
Tel: 888 867 5183
Fax: 888 364 2609
Email: sales@stackinc.com
Web:www.stackinc.com
Part No. 542046-001
Negative (black) wire of the shift-light to the Blue switch
Tachometer wire and Positive (red) wire of the shift-light
to a switched 12 Volt supply - e.g. Master switch,
Ignition switch
WW
WW
Warar
arar
arning:ning:
ning:ning:
ning: If a non STACK shift light is used the maximum
permitted current draw is 0.2 Amps.0.2 Amps.
0.2 Amps.0.2 Amps.
0.2 Amps. Exceeding this willwill
willwill
will
perper
perper
permanently damage the Tmanently damage the T
manently damage the Tmanently damage the T
manently damage the Tacho.acho.
acho.acho.
acho.
Stack Shift Light connection (optional)
Red
Black
12V
Blue wire
from Tachometer
Setting Engine cylinders
(IMPORTANT please read)
The tachometer is factory set in
demonstration mode
..
..
.
If you power up the
Tachometer without setting the cylinders the pointer will automatically start
moving
.
Set the cylinders as follows:
1. Press & hold the switch
!!
!!
!
and apply power to the tachometer.
2. Release the switch
!!
!!
!
when the pointer has stopped resetting on the stop pin.
3. Press the switch immediately
!!
!!
!
to select the number of cylinders - the pointer
will move to show the number of cylinders selected.
e.g. Press 4 times for 4 cylinders (pointer will point to 4000 RPM)
4. When the desired number of cylinders have been selected wait
""
""
"
3 seconds
and the tachometer will resume normal operation with the new setting.
5. To check the setting repeat operations 1 & 2 above, the pointer will move to the
selected number of cylinders. After 3 seconds the unit will revert to normal mode.
X
Note: For 2 stroke ignition systems set the cylinders to double the actual number of
cylinders.
For multi-coil ignition systems use the tach output provided or connect to one coil only and
configure the tacho for the cylinders the coil fires.
When using a dedicated Tacho output check the number of pulses per engine
revolution :- 1 pulse per rev = 2 cylinders (4 stroke) = 1 cylinder (2 stroke)
Ignition system Connection point (Orange wire)
Coil & Points Coil Negative (Low tension)
HEI systems Coil Negative (Low tension)
Magneto (Ext. or Int) Ground switch terminal (magneto side)
MSD Tachometer output
Magneto CD (2 stroke) Use HT pick up (ST697)
Ignition connection table
Tell Tale Memory
The pointer will initially move to the highest RPM value, then
after 5 seconds the needle will move to the full scale of the dial
and sweep down to zero.
Only when the pointer reaches zero will the memory be
reset
.
Normal Operation
When power is applied to the tachometer, the pointer will reset moving backwards
against the stop before moving to the current RPM (Zero RPM if the engine is not
running). When power is removed, the pointer is held at its’ last position (it doesn’t
necessarily return to zero)
Press and hold the switch as if you were to reset the Tell Tale
memory (see section above).
When the pointer sweeps down to zero - resetting the Tell Tale
memory, continue holding the switch for a
further 5 seconds
.
The pointer will then move to the current setting for the Shift-
RPM.
X
!!
!!
!
To
Recall
the Tell Tale Memory
The pointer shows the highest RPM seen since the memory
was last reset.
Note: The Tell tale will be remembered even when the power is off.
""
""
"
To
Reset
the memory
!!
!!
!
Hold
5
seconds
Shift-Light set up (optional)
""
""
"
!!
!!
!
Hold
14
seconds
To AdjustAdjust
AdjustAdjust
Adjust the Shift-RPM setting
!!
!!
!
Release the switch. Now each time the switch is pressed or
held on the pointer will increment 50 RPM. If the pointer
reaches full scale it will return to zero and start to increase
again.
When the desired Shift-RPM has been reached, release the
switch and wait
3 seconds
. The pointer will then move to zero,
indicating that the Shift-RPM has been set.
Note: The Shift-RPM will be remembered even when the power is off.
""
""
"
!!
!!
!
Wait
3
seconds
X
Now the switch can be released .
Note: If the switch is released before the pointer reaches
zero the memory will NOT be reset.
!!
!!
!
2W Max

Other Stack Measuring Instrument manuals

Stack ST500 User manual

Stack

Stack ST500 User manual

Stack Clubman ST200 User manual

Stack

Stack Clubman ST200 User manual

Stack ST8382 Pro DVR User manual

Stack

Stack ST8382 Pro DVR User manual

Stack ST200 User manual

Stack

Stack ST200 User manual

Stack ST8120 User manual

Stack

Stack ST8120 User manual

Stack ST8956 Installation and operating instructions

Stack

Stack ST8956 Installation and operating instructions

Stack Dash-2 User manual

Stack

Stack Dash-2 User manual

Stack ST8150 Installation and operating instructions

Stack

Stack ST8150 Installation and operating instructions

Popular Measuring Instrument manuals by other brands

Carel mboss quick start guide

Carel

Carel mboss quick start guide

ENDA ETS762 manual

ENDA

ENDA ETS762 manual

Aranet 4 HOME user manual

Aranet

Aranet 4 HOME user manual

pyroscience Pico-pH manual

pyroscience

pyroscience Pico-pH manual

Swema SwemaAir 40 instructions

Swema

Swema SwemaAir 40 instructions

AssetLink AssetPack 3 user manual

AssetLink

AssetLink AssetPack 3 user manual

Tietzsch MegaSafe ISO 1Ex User instructions

Tietzsch

Tietzsch MegaSafe ISO 1Ex User instructions

SPX RADIODETECTION 1205CXB user guide

SPX

SPX RADIODETECTION 1205CXB user guide

Sig Sauer ROMEO-X COMPACT Operator's manual

Sig Sauer

Sig Sauer ROMEO-X COMPACT Operator's manual

FLS FLOWX3 F9.63 instruction manual

FLS

FLS FLOWX3 F9.63 instruction manual

Bushnell 20-2020 instruction manual

Bushnell

Bushnell 20-2020 instruction manual

HT HT22D user manual

HT

HT HT22D user manual

Satec expertmeter EM720 Operation manual

Satec

Satec expertmeter EM720 Operation manual

Vemer Energy-230 LC user manual

Vemer

Vemer Energy-230 LC user manual

Hach Ultra ORBISPHERE 29981 Operator's quick guide

Hach Ultra

Hach Ultra ORBISPHERE 29981 Operator's quick guide

Image Engineering GEOCAL user manual

Image Engineering

Image Engineering GEOCAL user manual

Hanna Instruments HI 96769C instruction manual

Hanna Instruments

Hanna Instruments HI 96769C instruction manual

Crowcon Sprint Pro 1 quick start guide

Crowcon

Crowcon Sprint Pro 1 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.