SHIRE BALANCED FLUE GAS STOVE
TECHNICAL DATA
Pressure Setting From Cold
Natural Gas Inlet Pressure = 8”wg / 20 mbar
Product Identification No.: 0063AU5289
Appliance Category: BIIBS
Country of Designation: I.E.,G.B.,F.R.,P.T.,I.T.
E.S., N.L.,& B.E.
Gas Type
N.G.: I2H, G20, 20mbar/8” wg (I.E. & G.B.)
I2E +, G20 20 mbar/8” wg & G25,
25 mbar/10” wg (F.R. & B.E.)
I2L, G25, 25mbar / 8” wg (N.L.)
Manifold Pressure Maximum Setting
Natural Gas = 7.4”/18.5 mbar
Manifold Pressure Minimum Setting
Natural Gas = 1.1”/2.7 mbar
Full Rate = 7”/17.5 mbar
The gas pressure of the stove must be measured at
the burner test nipple.
Gross Input
Max. Input Natural Gas G20 = 4.9kW/16,712 Btu’s/h
Max. Input Natural Gas G25= 4.5kW/15,358 Btu’s/h
Efficiency: = Class 2
Gas Flow Rates at 15°C, 1,013mbar in relation to
gross calorific value of gas.
Natural Gas gross
calorific value = 37.78 MJ/m3
Maximum flow rate = 0.490 m3/hr
Burner: CPD Gas Burner
Burner Injectors:
CAT 18 Bray 320 - N.G.
Pilot Injectors
Size 3.5 - N.G.
Ignition: Remote Control Ignition.
402
380
GENERAL
Thank you for buying a Stanley Shire Balanced Flue
Gas Stove. This room heater and special flue sys-
tem should be inspected before use and at least
annually. More frequent cleaning may be required
due to excessive lint from carpeting, matting materi-
al, etc. It is imperative that control compartments,
burners and circulating air passageways are kept
clean.
The Shire Balanced flue system is a combustion
system where the inlet air and exhaust gases enter
and exit through two separate concentric passage-
ways within the same vent system.
The Balanced Flue system allows this gas appliance
to be vented directly to the outside atmosphere.
NOTE: Before installation, check that the local dis-
tribution conditions, nature of gas and pressure, and
adjustment of the appliance are compatible.
When installing, operating and maintaining your
Stanley Shire Balanced Flue Gas Stove, respect
basic standards of safety. Read these instructions
carefully before commencing installation or attempt-
ing to operate your stove. Failure to do so may result
in damage to property or personal injury and may
void the product warranty.
It is important to note that once a type of gas has
been specified the stove cannot run off any
other type of gas. (i.e. Natural Gas only)
The burner units are not interchangeable
between Gas types.
Republic of Ireland Installation
Install in accordance with the:
*Building Regulations Part J.
*I.S. 813 - Domestic gas installations.
*I.S. 265 - Part 1 & 2 - Installation of gas ser-
vice pipes.
U.K. Installation
Install in accordance with the:
*The Gas Safety (Installation and Use)
Regulations 1994 (as amended).
WARNING:Installation, commissioning, repair
and maintenance should only be undertaken
by a qualified service technician and installer.
Any adjustments undertaken by unqualified
individuals will void the product warranty and
may result in property damage or injury.