sugar-valley OXILIFE OXI 0 User manual

Electronic unit
OXILIFE
QUICK INSTALATION GUIDE
Electrolysis
RCA flow detector
pH probe
Redox probe
Mains connection 220V.
3.15A fuse
250 mA fuse
On-off switch
Air vent
Acid pump connection
2
3
4
5
6
7
8
9
10
11
DESCRIPTION
1
Cell
Electrolysis cell
RCA flow detector
Cell connection
Flow/gas detector
1
2
3
Optional extras
pH probe Conductivity probeRedox probe
Cell housing
Probe
Probe casing
Connection housing
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
5
4
With the system that utilises LOW-SALINITY ELECTROLYSIS as the flow of water passes through the titanium cell,
oxidising agents such as OXYGEN, PEROXIDE, HYDROXYLS, OZONE, etc. are generated. This combats, oxidises
and eliminates the organic material present in the water.The generated oxidisers turn back into H2O2 when they reach
thepool.Thesalinityprovidedatstart-up(1.5-2.5g/l)keepsthewaterinperfectconditionwithafreechlorineresiduethat
isimperceptibletotheeyesandskin.
2
5
1
4
3
10
7
8
9
6
2
34
5
11
10
Probe
Probe casing
Connection housing
Probe
Probe casing
Connection housing

INSTALATION
2
System instalation diagram
Electrical housing
1
Filtration pump timer
ASand filter
BRecirculation pump
C
Electrolysis cell (always in vertical position)
3PH probe (Optional, for models with PH control)
4Redox probe (Optional, for models with redox control)
5Conductivity probe (Optional, for models with conductivity control)
6
Chlorine pump (Optional, for models with redox or free chlorine
control + auxiliary chlorine dosage)
11
Chlorine injector (Optional, for models with redox or free chlorine control)
12
Chlorine container (Optional, for models with redox or free chlorine control,
not supplied with unit)
13
10 Hydrochloric acid container (optional, for models with PH control,
not supplied with unit)
Acid pump (Optional, for models with PH control)
8Acid injector (Optional, for models with PH control)
9
Other pool equipment
(pool heating, heat exchanger, etc,)
15
Electrical consumption
OXILIFEsynchronizedwithFILTRATION
Ensure the electrolysis unit is synchronized with the pool filtration and stops
functioningwhenwatercirculationhasstopped.
TITANIUMCELLconnectionoverheating
Ensure all electrical connections are firmly fixed to avoid false contacts and
subsequent overheating of system components (Especially concerning the
electrolysiscellwithusageabove33A).
OXI 0
OXI 1
OXI 2
OXI 3
OXI 4
OXI 5
120W
180W
205W
228W
600W
1020W
Recommended
protection
Maximum
consumption 6A
10A
10A
16A
16A
25A
A
B
C
1
3
4
5
6
15
13 12
11
10
9
8
min. 1m

Electronic housing display
ALARM
Excessiveincrease ordecreasein parameters(+/-15%
fromtheselectedparameters).
CHECKLEVELSINACID/BASECONTAINERS
CHECKPROBECALIBRATION
InsufficientFLOWorcelldisconnected
Production halted due to lack of flow, or gas in the
titaniumcelldetector.
ONLY SYSTEMS WITH FREE CHLORINE CONTROL
(ppm's)
INSUFFICIENT FLOW in the CHLORINE detector. The
rotary sensor detects insufficient flow. CHECK the
rotameter pendel – and solve the system's hydraulic
problem (If there is a preceding filter this must be
cleaned).
Conductivity/Celllife
Lowconductivity(Seesection3)
Titanium cell incrusted (See cleaning process in section
5)
Cellsurfacecorroded(Seesection7)
ONLYSYSTEMSWITHREDOXORFREECHLORINE
The system has automatically stopped as Redox levels
areabovethechosenvalues(Seesection5)
Timedelay
Period of non-production of oxidant while system
changespolarity(0-120sec.)
Status led's
Electrolysis production
ENTER button
Right button
Right button
START UP
4
INITIAL ADJUSTMENTS
3
Water adjustments
1.Adjust the alkalinity between 90 and 110
ppm.
2.AdjustthePHbetween7,2and7,4
3.Adjust the chlorine between 1 and 1,5
ppm.
SHOULD the water be supplied from a well:
shock chlorinate with Tricloroisocyanuric
acid(2Kg./50m3ofwater)
Adding Salt to the Water
Start up
Add 1,5 to 2,5 Gramm Salt (without Yod) for each litre of water in your swimming pool
(1,5 to 2,5 kg NaCl per m3 Water). Open the bottom valve of your swimming pool and
add the Salt directly to your swimming pool water. Let the circulation pump run during
thefirst24 hoursyourOxilifesystemis workinginordertodissolve theSaltcompletely.
Your Oxilife System will operate without any problems with salt concentrations from
1,5gto50gSaltperlitre.
IN POOLS WHICH RECEIVE LARGEAMOUNTS OF STRONG SUNLIGHT 40gr/m3
OFSTABILYSER(Isocyanuricacid)MUSTBEADDED
Up button
Down button
PH probe
Conductivity probe/
water temperaturez
Free Chlorine/Redox
THEOXILIFESYSTEM CANBE USEDINSPA´STOPRODUCEBROMINE:Add0,12 Kgof SodiumBromineforeachm3 ofWater (inconjunctionwith
thenormalsaltconcentration-seeabove).OxilifewillgenerateenoughBrominetopurifyyourspa.

MAINTENANCE
6
1-Thepoolmustbevacuumedasusualandtheskimmersemptiedwhenevernecessary.
2-Filter backwashing: with Sugar Valley systems the filter requires only occasional backwashing; once every 20 days should be sufficient (providing the filter pressure does
notexceed1bar,inwhichcaseabackwashmaybenecessary).
3-ADDINGNEW WATER:Alwaysthrough theskimmerssothatthenewwater passesthroughtheOxilifebefore enteringthe pool.Remembertoaddthe necessarysalt:6gr.
peraddedlitreofwater.
4-InwinterCHANGINGTHEPOOLWATERISNOTRECOMMENDABLE.Werecommendthatthesystemruns2-3timesperweek(2-3hrs.perday).
DOSAGE PUMPS: Check regularly to ensure that the container contains liquid to prevent the dosage pump running dry. The dosage pump requires maintenance
(INSTRUCTIONSONBOX).
PH PROBES/REDOX/CONDUCTIVITY: Probes must be cleaned whenever necessary (check every 5-6 months). To clean the probe insert in distilled water (Clear liquid).
Aftereachcleaningtheprobesmustbecalibrated.
General maintenance
VERY IMPORTANT; Ensure that the system is turned off during filter backwashing.
FREE chlorine : 1.0 – 2.0 PPM
pH : 7,1 – 7,5
Fortnightly checks
TOTALalkalinity(TAC) :80-120ppm
Saltconcentration :1.500–2.000ppm
Cyanuricacid :30-50ppm
Titaniumcell :Visualinspectiontodetectincrustations.
Monthly checks
SYSTEMS WITH REDOX CONTROL
5
CleaningtheTitaniumcell:Maintenanceofthedisinfectionsystem(Electrolysis)consistsofcleaningthecellorelectrodeevery2-3monthsshoulditappearnecessary(carry
outavisualinspection)Tocleantheelectrode:
-Removethecellfromitssupport(afterturningoffthefiltrationsystemandclosingoffthenecessaryvalves).
-Placetheelectrodefornomorethan10min.in15%HYDROCHLORICACID(salfumant).1,5lofacidforeach8,5lofwater.
-Oncetheincrustationshavesoftenedremovewithahosetocompletecleaningthecell.
USE NO METALIC OR SHARP OBJECTS TO REMOVE INCRUSTATIONS. Scratching the edges or surface of the cell will make it vulnerable to chemicals, deteriorate the
cellandannultheguarantee.
Titanium cell maintenance
Duringthefirst10-15daysyourpoolsystemwillrequiremoreattentionandthefollowingcare:
1CHECK THE PH REMAINS BETWEEN THE IDEALLEVELS (7,2-7,4). If the PH is unusually unstable AND USESALOT OFACID check the alkalinity (Recommended
levelsbetween80and125ppm.).
2Thepoolmustbevacuumedandtheskimmerscleanedwhenevernecessarytoensureperfectwaterconditions.
REMEMBERthattheSugarValleysystemrequiresacertainamountoftimetoadapttoyourswimmingpoolandwillrequireadditionalchemicalsduringthefirst3-5days.
Initial days of maintenance
The Redox level advises us of the potential oxidization or reduction level and is used to determine the level of water sterilization. The parameters or Set Points are the
minimum/maximumacceptedREDOXlevelsbeforethetitaniumcellisconnected/disconnected.
AdjustingtheidealREDOXlevel(setpoint)isthelaststepintheOXILIFEstartupsequence.TofindtheoptimumREDOXlevelforyourpoolfollowthesesteps:
1. Connectthepoolfiltrationsystem(Thesaltinthepoolmustbeadequatelydissolved)
2. Addchlorinetothepooltillalevelof1-1,5ppm.Isachieved(Approx.1-1,5gr/m3ofwater).PHlevelsshouldbebetween7,2and7,5.
3. After 30 min. test the free chlorine levels in the pool (DPD1 manual test kit) If the free chlorine level is between 0,8-1,0ppm. Look at the REDOX screen and memorize
thislevelasthesetpointtoCONNECT/DISCONNECTthehydrolysiscell(Tomemorizethesetpointseesection8)
4. Thenextdaycheckfreechlorinelevels(manualDPD1testkit)and REDOX,Raise/lowersetpointifnecessary

MENU ACCESS
7
q
HOLD FOR 3 SECONDS TO ACCESS/EXIT
USER MENU
Menu access
User menu
pH SET POINTS
To modify parameters/maximum pH set point
To LOWER pH - maximum water pH - CONTROLS THE ACID PUMP (optional equipment)
CHLORINE PRODUCTION LEVEL
To modify level
To confirm and change menu
To modify parameters/minumum pH set point
To INCREASE pH - minimum water pH - CONTROLS THE BASE PUMP (optional equipment)
pH PROBE CALIBRATION
Insert probe in pH 7 sample,
wait till reading has stabilized
Clean probe in NEUTRAL.
Insert probe in pH 10
sample and wait till reading
is stable.
REDOX SET POINT
To modify parameters/Redox set point To confirm and change menu
REDOX PROBE CALIBRATION
Insert probe into 465mv sample, wait till
reading is stable..
CONDUCTIVITY SET POINT
To modify parameters/conductivity set point To confirm and change menu
CONDUCTIVITY PROBE CALIBRATION
Insert the probe in
sample, wait until reading
is stable.
Repeat calibration or change probe.
Displays
Conductivity control
5
Redox/Free chlorine control
pH control
Electrolysis level
4
3
2
1
q
Change conductivity
reading to match
sample
Calibration correct
Repeat calibration
or change probe.
Calibration correct
Repeat calibration
or change probe.
Calibration correct
Repeat calibration
or change probe
RECOMMENDED LEVEL: 6,8
RECOMMENDED LEVEL BETWEEN 7,2AND 7,5
RECOMMENDED LEVEL: MAXIMUM LEVELACCORDING TO MODEL
DISPLAY 1
DISPLAY 2
DISPLAY 3
DISPLAY 4
1
2
3
4

TROUBLESHOOTING
8
Display blank
*CheckOn/Offswitchisilluminated
*Checkexternal250mAfusehasnotfused.
*Checkelectricsupply:210-230V50Hz
*IfproblempersistscontactTECHNICALSERVICE
Electrolysis does not reach maximum intensity
*Checksodiumbromideorcommonsaltconcentrationinwater.
*Checkcellstatus(maybeincrustedorcalcified).
*Cleanelectrodefollowinginstructionsinsection6.
*Cleanflowdetectorsituatedinthecellcasing.
*Check titanium cell is not worn (remember that the cell is guaranteed for 5000-6000
hours(approx.2-3yearsofsummerusage)-seetroubleshootingformoreinformation).
Polarity 1 reaches max. intensity but polarity 2 (Auto clean) does not
*IFSALTLEVELISCORRECT(2,5kg./m3) cellisreachingendoflife.Asofthismomentcheckintensityevery15-30days
*Whenpolarity2does notreach 50%we recommendsubstituting cellforanewoneifduringthesummerormaximumusageperiod.Ifthisshouldhappeninwinterchangebefore
thenextseason(summer).
Free chlorine levels don't reach 0,2ppm. First thing in the morning
*INCREASEFILTRATIONINTERVAL.
*INCREASEelectrolysislevel.
*Checklevelsofsodiumbromideorcommonsaltinthepool(2gr.NaCl/L).
*Checklevelofisocyanuricacidinpool(30-50ppm.)ONLYifusingCOMMONSALT.
*CheckreactiveagentsintestkitarenotTOOOLD.
*Hasthetemperatureoramountofusersrisen(see3.1/3.2seechapter“Watermaintenance”).
*pHisabove7,8andmustbeadjusted.
Electrolysis display shows LO
*Waterlacksconductivity(seesection3“waterpreparation”).
*Checkforincrustationsoncell.
*Seetroubleshooting“Hydrolysisdoesnotreachmaximumintensity”.
White flakes in pool
*Thishappensinexcessivelyhardunbalancedwaters.
*Balancethewaterandcheckthecell,proceedingtocleanitifnecessary.
Electrolysis display shows FL
*Checkflowdetectorcable.
*Cleanincrustationsofflowdetectorattopofcellcasing.
*Checksystemisfreeofair(Probemustbealwayssubmerged).
RUST on metallic components in pool
*Metallicelements lackstandardized earthconnection.Contactanelectriciantosolve
problem.
*Rustedcomponentsarenotstainlesssteel:minimum304-recommended316.
EARTHING
All metallic components in the pool, such as lamps, ladders, heat exchangers, drains or similar elements within 3.00m. from pool (10feet) must be connected to an earth below
37Ohms.
WERECOMMENDHEATEXCHANGERSBEMADEOFTITANIUM.
CLEANINGFILTER
EnsureOXILIFEisNOTRUNNINGduringbackwash.
VERYIMPORTANT
REMEMBERthatthesystemneedssometimetoadapttoyourpoolandyouwillhavetoincreasechemicallevelsforthefirst5days.
WARNING
Keepchemicallevelsinpoolasinstructedinthismanual
SECURITY
Toavoidaccidentsthisproductshouldnotbehandledbychildrenunlesssupervisedbyanadult.Childrenshouldbesupervisedatalltimeswheninornearaspa,poolorJacuzzi.
HANDLINGANDDOSINGDANGEROUSCHEMICALS
Chemicalsshould behandledwith extremeprecaution.WhenpreparingACID,ALWAYSADDTHEACIDTOWATER,neveradd watertoacid!!!VERYdangerousgasses maybe
produced.
EXCESS CHLORINE in water
*Lowerelectrolysiscellintensity.
*If your system includesAUTOMATIC REDOX CONTROL check REDOX
SETPOINT.
*CheckREDOXprobeandcalibrateifnecessary.
Titanium cell incrusted in less than 1 month
*Veryhard waterswitha highpHandtotalalkalinity (Balancewateradjusting
pHandtotalalkalinity).
*Checktoensurethesystemautomaticallychangespolarity(LED'salternate
every300min.approx.).
*CONSULT with our technical service to consider ACCELERATING THE
polaritychange(Auto-cleaning)WARNING:acceleratingthepolaritychange
decreasesthecelllife(5000hours)proportionally.
This manual suits for next models
5
Table of contents
Other sugar-valley Swimming Pool Cleaner manuals
Popular Swimming Pool Cleaner manuals by other brands

GRE
GRE ABS3 instruction manual

AquaMAX
AquaMAX X2 Operating instructions and parts list

Pool Blaster
Pool Blaster iVAC AQUA BROOM quick start guide

ubbink
ubbink RobotClean 7 Operating instructions and parts list

Zodiac
Zodiac Alpha iQ Pro RA 6900iQ quick start guide

Maytronics
Maytronics Dolphin M600 Disassembly instructions