manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Sunlight Supply
  6. •
  7. Controllers
  8. •
  9. Sunlight Supply TITAN CONTROLS ZEPHYR 3 User manual

Sunlight Supply TITAN CONTROLS ZEPHYR 3 User manual

Other Sunlight Supply Controllers manuals

Sunlight Supply TITAN CONTROLS Helios 5 User manual

Sunlight Supply

Sunlight Supply TITAN CONTROLS Helios 5 User manual

Sunlight Supply TITAN CONTROLS HELIOS 8 Product information sheet

Sunlight Supply

Sunlight Supply TITAN CONTROLS HELIOS 8 Product information sheet

Sunlight Supply Titan Controls Helios 2 User manual

Sunlight Supply

Sunlight Supply Titan Controls Helios 2 User manual

Sunlight Supply TITAN CONTROLS HERCULES 2 User manual

Sunlight Supply

Sunlight Supply TITAN CONTROLS HERCULES 2 User manual

Sunlight Supply TITAN CONTROLS KRONUS 2 User manual

Sunlight Supply

Sunlight Supply TITAN CONTROLS KRONUS 2 User manual

Sunlight Supply Sun System 1 User manual

Sunlight Supply

Sunlight Supply Sun System 1 User manual

Sunlight Supply Titan Controls Atlas 4 User manual

Sunlight Supply

Sunlight Supply Titan Controls Atlas 4 User manual

Sunlight Supply TITAN Controls Saturn 4 User manual

Sunlight Supply

Sunlight Supply TITAN Controls Saturn 4 User manual

Sunlight Supply TITAN CONTROLS HELIOS 8 User manual

Sunlight Supply

Sunlight Supply TITAN CONTROLS HELIOS 8 User manual

Sunlight Supply Titan Controls Helios 1 User manual

Sunlight Supply

Sunlight Supply Titan Controls Helios 1 User manual

Sunlight Supply Titan Controls Helios 7 Product information sheet

Sunlight Supply

Sunlight Supply Titan Controls Helios 7 Product information sheet

Popular Controllers manuals by other brands

Sunricher SR-ZV9003T3-RGBW-US Installation

Sunricher

Sunricher SR-ZV9003T3-RGBW-US Installation

Ksenia intro Installation and configuration manual

Ksenia

Ksenia intro Installation and configuration manual

Inovance CAN200 Series manual

Inovance

Inovance CAN200 Series manual

Gauzy LC6 FLEX Controller Installation and operation guide

Gauzy

Gauzy LC6 FLEX Controller Installation and operation guide

Viking SLP-1 Technical practice

Viking

Viking SLP-1 Technical practice

CKD KBX-30E-U Series instruction manual

CKD

CKD KBX-30E-U Series instruction manual

Sharp Energy Sun Flux User manual & installation guide

Sharp Energy

Sharp Energy Sun Flux User manual & installation guide

Yamaha RCX40 user manual

Yamaha

Yamaha RCX40 user manual

AB Quality PowerFlex 400 Frames D-H Service bulletin

AB Quality

AB Quality PowerFlex 400 Frames D-H Service bulletin

Yamaha MJC8 owner's manual

Yamaha

Yamaha MJC8 owner's manual

AL-KO ATC operating instructions

AL-KO

AL-KO ATC operating instructions

Savant SmartControl 2 Deployment guide

Savant

Savant SmartControl 2 Deployment guide

GameSir T3S user manual

GameSir

GameSir T3S user manual

Kostal inveor operating manual

Kostal

Kostal inveor operating manual

Emerson Yarway 20-55 Operating and safety instructions

Emerson

Emerson Yarway 20-55 Operating and safety instructions

CoCo ACM-LV24 Quick installation guide

CoCo

CoCo ACM-LV24 Quick installation guide

Brooks SLA5810/20 Installation and operation manual

Brooks

Brooks SLA5810/20 Installation and operation manual

SIGMA TEK SR 011 Technical manual

SIGMA TEK

SIGMA TEK SR 011 Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

www.titancontrols.net
www.titancontrols.net
Notes:
_________________________________________________
_________________________________________________
_________________________________________________
_________________________________________________
_________________________________________________
_________________________________________________
________________________________________________
1 Square = ____ Foot/Feet
®
VANCOUVER, WASHINGTON U.S.A.
VANCOUVER, WASHINGTON U.S.A.
Revision C – 8/22/2012 © Titan Controls
Zephyr™3
• Warnings&Cautions
• Zephyr™3-Heating/CoolingController
• InstructionsforOperation
• TroubleshootingTips
• ControllerSpecications
• InstallationExample
• WarrantyInformation
• ServiceandRepairProgram
Warnings & Cautions
• Readallinstructionsbeforeoperatingcontroller.
• Donotputyourcontrollerinanareawhereitcangetwetorsprayed.
• Mountyourcontrollersecurelytothewallusinghardwareprovided.
• Whenusing“bugbombs”inarea,covercontrollercompletelytoavoidcorrosion.
• Therearenoserviceablepartsincontroller.Donotattempttorepairtheunit.
• Breakingtamperproofsealwillvoidyourwarranty.
• Donotputpaperclips,tools,etc.intounit.Possibleelectrocutionmayoccur.
• Plugcontrollerintosurgeprotectortoavoidpotentialdamagetotheunit.
• Conrmthatyourpowersourceis120Volts/15Ampspriortopluggingcontrollerinto
outlet.
• Checkthatallequipmentthatwillbeactivatedbythiscontrolleristhepropervoltage.
• Verifythattheequipmentyouarecontrollingdoesnotexceedatotalof15amps.
• Thiscontrollerisdesignedfor“insideuse”only.
• AvoidplacingthecontrollernearheatgeneratingsourcessuchasaCO2Generator.
• Usecautionifoperatingcontrollerinextremelyhumidenvironments(90%andabove).
• Donotusecontrollerforpurposesotherthantheunitwasdesignedtofunction
• Usecontrollerwithindenedenvironmentalspecications.
• AskyourDealerfortipsandtechniquesregardingtheuseofthiscontroller.
• Beconscientiouswhendisposingofanyproducts.
• EnjoyyourTitanControls®lightingcontrollerforyearstocome!
WARRANTY SERVICE: Please read warranty information first
Ifafterreviewingthetroubleshootingtipstheunitwillstillnotwork,youshouldreturnittothe
Dealerwhereyoupurchasedit.Theymaybeabletofurtherevaluatetheunitandtestitsvarious
componentsandquitepossiblywillbeabletoidentifyand/orxanyproblems.IftheDealeris
unabletoxtheunit,theywillreturnittousforfactoryrepair.
IftherearenoDealersinyourarea,youmaycontactusdirectlyfortechnicalsupport.Ifwe
cannothelpyouresolvetheproblemoverthephone,wewillissueyouaReturnMerchandise
Authorization(RMA)numberauthorizingyoutoreturntheunittousforfactoryreconditioning
(ifthecontrolleriscurrentlyunderwarranty).ContactthenumberbelowforaRMAnumberand
shippingaddress.Pleasecompletetheformbelowandincludeitwithyourunit,andwritethe
RMAnumberclearlyontheoutsideofthebox.
Pleasepackagetheunitinitsoriginalpackaging.Ifitisdamagedinshipmentwecannotbeheld
responsible.Insuringtheparcelisrecommended.
Oncewereceivetheunitback,wewillrepairitwithin48hours(business)andreturnittoyou
freightprepaidviaUPSgroundshipment.
Include the followingifreturningdirectlytoTitanControls®
•Copyofproofofpurchase•Thiscompletedform•RMA#ontheoutsideofthebox
ReturnMerchandiseAuthorizationNumber(Required):____________________________________________
Dealer/Customer’sName:___________________________________________________________________________
Dealer/Customer’sContactName:___________________________________________________________________
Address:____________________________________________________________________________________________
_____________________________________________________________________________________________________
Phone#:____________________________________________________________________________________________
Emailaddress:_______________________________________________________________________________
What is the nature of the problem? Please provide as much information as possible: _________
___________________________________________________________
___________________________________________________________
___________________________________________________________
___________________________________________________________
___________________________________________________________
___________________________________________________________
Sendtoyournearestlocation–shippingaddresswillbegivenwhentheRMA#isissued.
www.titancontrols.net
For technical assistance call us at 1-888-80-Titan or 1-888-808-4826.
®
Zephyr™3 – Heating/Cooling
Controller Overview
TheZephyr™3isusedtomaintainthetemperaturelevelinyourgrowingenvironment.
Thetemperaturecanbeadjustedbysettingthedialonthefrontofthecontrollertoyour
preferredsetting.WhentheZephyr™3isintheCOOLINGMODEandthetemperature
exceedsthepredeterminedsetting,thepiggybackcordsetisactivatedandwilloperatethe
exhaustfanuntilthetemperatureislowerthanthepreferredsetpoint.WhentheZephyr™
3isintheHEATINGMODEandthetemperatureisbelowthepredeterminedsetting,then
thepiggybackcordsetisactivatedandwilloperatetheheater(1500Wattsorless)untilthe
temperatureishigherthanthepreferredsetpoint.TheZephyr™3operatesupto15amps
maximumcapacityonastandard120Voltcircuit.Builtwiththehighestqualitycomponents,
theZephyr™3willprovidetheuserwithyearsoftroublefreeservice.Controllerscreatedfor
ourindustry,byourindustry!
Instructions for Operation
• SecurelymountyourZephyr™3inyourgrowareaandawayfromanymoisture,spray,
pesticides,etc.usingthehardwareprovided.
• SetgreenrockerswitchineitherCOOLINGorHEATINGmode.
• Plugtheexhaustfanorheaterintothepiggybackcordset.
• Turnthefan‘ON’tothefastestsettingpossible,ifadjustable.
• ORsettheheateratthehighestsettingpossible,ifadjustable.
• Setthe‘Temperature’dialatthepreferredtemperaturelevelforyourgarden.
• Finally,plugtheZephyr™3intoadedicated120Volt–15Amppowersource.
• UseofasurgeprotectiondeviceisrecommendedtoprotectyourZephyr™3from
potentialpowerdamageinareaswherethismaybeanissue.
• YourZephyr™3willnowcontrolyourequipmentatthedesiredsetting.
Troubleshooting Tips
IftheZephyr™3isnotperformingasexpected,trythefollowing:
a.Conrmthatyourpowerinputsourceisactivebyusingavoltagetestmeter,andverify
thatthepowerinputsourceisproviding120VoltsofpowertotheZephyr™3.
b.ValidatethatthepoweroutletoftheZephyr™3isactivebysettingtheswitchinthe
COOLmodeandputthetemperaturedialatthelowestsetting.Thenuseavoltagetest
metertoverifypowerisowingthroughthecontrollertothepoweroutlet.
Warranty Information
•TitanControls®warrantstheoriginalpurchaseofthisproductagainstdefectsinmaterial
andworkmanshipundernormaluseforve(5)yearsfromthedateofpurchase.
•Duringthewarrantyperiod,TitanControls®will,atouroption,andwithoutcharge,repairor
replacethisproductifthecontrolleroranyofitscomponentsfailormalfunction.
•AllreturnsorrepairsmustbeaccompaniedbyaReturnMerchandiseAuthorization(RMA)
numberpriortoanyserviceoftheproduct.
•Thiswarrantyisexpresslyinlieuofallotherwarranties,expressedorimplied,includingthe
warrantiesofmerchantabilityandtnessforuseandofallotherobligationsorliabilitieson
thepartoftheseller.
•Thiswarrantyshallnotapplytothisproductoranypartthereofwhichhadbeendamaged
byaccident,abuse,misuse,modication,negligence,alterationormisapplication.
•Controllerswithserialnumbersordatetagsthathavebeenremoved,alteredorobliterated;
brokensealsorthatshowevidenceoftampering;mismatchedboardserialnumbersor
nonconformingparts;areexcludedfromcoverage.
•TitanControls®makesnowarrantywhatsoeverinrespecttoaccessoriesorpartsnot
suppliedbyTitanControls®.
•Monetaryrefundsofthewarrantywillnotbegiven.
•TheBuyerassumesallresponsibilityregardingtheuse&installationofthiscontroller.
•Allwarrantyserviceisprovidedthroughthefactoryoranauthorizedservicerepresentative.
•ThiswarrantyshallapplyonlytotheUnitedStates,includingAlaska,Hawaiiandterritories
oftheUnitedStates.
•Defectivecontrollersneedtobereturnedwiththe“proofofpurchase”receipt.
•Foradditionalwarrantyinformation,contactaTitanControls®TechnicalService
RepresentativeoryourDealer.
•NOTE:TitanControls®isacontrollermanufacturer.Allsalesofferingstothepublicare
donethroughanationwidegroupofDealers.Nosalesofferingswillbemadedirectlytothe
generalpublic.
Service and Repair Program
•ForallserviceandrepairspleasecontactourTechnicalServiceRepresentativeforaReturn
MerchandiseAuthorization(RMA)number.
•Allfactoryservice&repairswillbecompletedwithin48hoursofreceiptofcontrollerand
afterauthorizationbycustomerforrepairs.
•TitanControls®will,atitsdiscretion,repairorreplacethecontroller.
•FactorycalibrationservicesareavailableforallTitanControls®.
•ReturningUnits:Pleasecontactyourretailstoreforreturns.
Troubleshooting Tips, Continued
c.Ensurethattheexhaustfanis‘ON’andsetatthefastestspeed,ifadjustableORtheheater
isatthehighestsettingpossible,ifadjustable.
d.VerifythattheZephyr™3issetatthepropertemperatureleveltoactivateanddeactivate
equipment.
e.Ifyourventilationequipmentdoesnotturnoff,verifythatyourexhaustfanisthecorrect
sizeforyourgrowarea.Increasethesizeofexhaustfan(ifnecessary)tocoolthegardenas
quicklyaspossible.
f. Ifyourheatingequipmentdoesnotturnoff,verifytheyourheateristhecorrectsizeforyour
growarea.Increasethesizeofheater(ifnecessary)towarmyourgardenasrequired.
g.IfyouarestillhavingproblemswithyourZephyr™3,pleasecontactourTechnicalService
Representativeat888-808-4826toassistyoufurther.
Controller Specifications:
• Size=8”Hx4”Wx2.5”D
• Weight=2lbs.
• InputVoltage=120Volts/AC
• OutputVoltage=120Volts/AC
• MaximumAmperage=15Amps
• OperatingHertz=60Hz
• Minimum/MaximumTemperatureControlLevels=40°to100°F(5°Cto38°C)
• TemperatureAccuracy=±3°Fofdesiredsetting
• Cordset=6feet-14/4SWJ
• StorageTemperature=32°to135°F(0°to58°C)
• OperatingTemperature=45°to95°F(7°to35°C)
Installation Example