INTRODUCTION 2
PRODUCT OVERVIEW 2
KEY FEATURES 3
SPECIFICATIONS 3
CHARGE THE GRAVITY : 3 WAYS 4
HOW TO USE THE GRAVITY 2232 5
STORAGE AND MAINTENANCE 6
DISCLAIMER 6
DESCRIPTION 6
FAULT CODE AND TROUBLE SHOOTING 6
OUR WARRANTIES 7
PRECAUTIONS 7

IN THE BOX
Geoffroy & Henri
COMPATIBLE WITH
INTRODUCTION
The Gravity 2232 is a very high capacity portable generator,
capable of providing high AC power and DC power for all your
devices.
It works just like a generator, but without emitting any noise nor
burning any fuels, unlike traditional diesel generators.
The Gravity 2232 solar power generator can be recharged via
wall outlet (the charger is provided) or via solar panels.
We recommend using the adequate Sunslice 150W solar panels
to charge your Gravity 2232 quickly and efficiently.
2 x AC/DC Adapter Charger plug
cigarette lighter
Gravity 2232
SMARTPHONE GoPro
TABLET
LAPTOP CAMERA DRONE
TV DESKTOP
PC FRIDGE TABLE LAMP ELECTRIC
BIKE
ELECTRIC
DRILL
1
2
V
/
1
0
A
P
D
6
0
W
P
D
6
0
W
Q
C
3
.
0
Q
C
3
.
0
Q
C
3
.
0
5
V
/
2
A
C1
OUT1 OUT 2
OUT3 OUT 4
C2
88 98 cha
time
USB-C Output
Port*2
USB-A Output
Port*4
AC Output Power
On/Off Switch
DC Output Power
On/Off Switch
Main Power On/Off
Switch
Car Charger
Output Port
DC 5521 Output
Port
LCD Screen
AC Output Port
PRODUCT OVERVIEW
LED Light
Power
On/Off Switch
Anderson
Recharging
Input Port*2
7909
Recharging
Input Port*2
LED Light
Weight : 20.7kg
420 mm
313 mm
270 mm
Press 3s

LCD SCREEN DESCRIPTION
KEY FEATURES
Æ2232 Wh / 603’200 mAh (3.7V)
Æ2 x USB-C PD OUTPUT 60W
Æ4 x USB-A QUALCOMM 3.0
ÆCHARGES MANY POWERFUL DEVICES
ÆHIGH SOLAR INPUT
ÆSTRONG LED Light
ÆROBUST DESIGN
ÆEASY TO CARRY
Æ20.7kg
Battery capacity
percentage
Fault warning
Charge&discharge
time display
AC port status
USB-A
USB-C High temperature
protection
Car charge port
status
DC5521 port status
Charging power
display
Discharging power
display
Battery capacity
circle
Low temperature
protection
Cooling fan
SPECIFICATIONS
CAPACITY 2232 Wh / 603’200 mAh (3.7V)
AC OUTPUT Universal AC Outlet : 4x 2400W (220V)
2400W MAX Peak Power : 5000W
Pure Sine Wave : 50Hz
DC OUTPUT 4 x USB-A QC3.0 (18W) : 5V/3A, 9V/2A,
12V/1.5A ,5V/2A
2 x USB-C PD (60W) : 5V/3A, 9V/2A,
15V/3A, 20V/3A
2 x DC 5521 : 12V/10A
1 x Cigarette Lighter : 12V/10A
AC INPUT 2 x DC7909 (AC/DC) : 200W
SOLAR PANEL 2 x Anderson : 12-45V/11A
INPUT (not included) (Single maximum input 500W)
2 x DC7909 : 12-45V/4.4A
(Single maximum input 200W)
BATTERY TYPE LiFePO4
IP GRADE IP21
WEIGHT 20.7kg
DIMENSIONS 420 x 270 x 313 mm
CHARGING STATUS LCD Screen
IN THE PLANE Not Allowed
WORKING 0~40°C
TEMPERATURE

STANDARD AC ADAPTER
CAR CHARGER
SOLAR PANELS
MC4 to
Anderson
Y DC6530
cable
DC6530 female
to MC4
CHARGE THE GRAVITY : 3 WAYS
Please connect the 200W AC adapter to the DC7909 input of
the Gravity 2232. In the meantime, you can also connect the
second 200W AC adapter to the other DC7909 input in order to
double the charging speed. It will take about 6 hours to charge
the Gravity 2232.
If your solar panel is equipped with an Anderson output, you may
connect it directly to the Gravity 2232. In most cases, an adapter
will be required. Sunslice can provide MC4 to Anderson adapters,
allowing you to easily connect your solar array to the Gravity 2232.
Once the solar panels are correctly connected to the battery, the
battery LCD screen will indicate the battery is charging and will
display the input power being delivered into the battery in real time.
ANDERSON Input: The Gravity 2232 is equipped with 2
ANDERSON inputs, which allow the battery to be charged with up
to 500W each. They can be used simultaneously, providing up to
1000W of solar power to the battery.
It is important to check the maximum voltage and current ratings
allowed on the Anderson inputs in order to safely connect the
solar panels to the battery and avoid material damage and
potential injury.
We recommend using Sunslice solar panels to ensure perfect
compatibility, but the battery is also compatible with other solar
panels. In case you are unsure of your set-up, or which panels to
choose, please contact Sunslice for support.
7909 Input: The 7909 DC inputs are mainly used to charge the
Gravity 2232 from the mains, but they also allow solar charging,
up to 300W each (maximum voltage of 45V). If your solar panel
respects the voltage and current limits, and is equipped with a
7909DC output cable or a 7909DC adapter, you may connect them
to the 7909 input of the battery.
The Anderson ports and DC7909 ports may NEVER be used at the
same time. Only one type of input may be used at any time.
Please connect the 7909 input charge port and the vehicle’s 12V
cigarette output port with our standard 7909 transfer cables. It
will take at least 23 hours to be fully charged.
DC OUTPUT:DC OUTPUT:
USB-C USB-A

C1
OUT1 OUT2
OUT3 OUT4
C2
88 98 cha
time
HOW TO USE THE GRAVITY 2232
AC OUTPUT
DC OUTPUT
LED LIGHT
FREQUENCY SWITCHING OPERATION
When the main power button is ON, gently press the AC output
button, the icon « AC» in the LCD screen will lit up. It means the
AC ports can be used properly. Press the button again and the
AC ports will be turned Off.
!! DON’T FORGET TO TURN IT OFF AFTER USING IT TO SAVE
BATTERY POWER !!
When the main power button is ON, press the power light button
on the other side. Press once, 50% brightness, press twice 100%
brightness. Press tird time , it will change to SOS flashing mode.
Press again to turn it off.
When the main power button is ON, press the DC button on
the left side of the function panell, USB-C and USB-A function
can be used normally, and the panel corresponding icons, on
the LCD screen will lit up. Press the DC button on the right
side of the function panel, DC 5521 and the car charger ports
can be used properly, and the corresponding icons will lit up.
Press the power button again, the corresponding icons and
the ports will be turned off.
DC OUTPUT:DC OUTPUT:
DC OUTPUT:
MAIN POWER
AC OUTPUT
USB-C USB-A
DC 5521 + Car
charger
POWER LIGHT
BUTTON
1. In the power - On state, turn off the AC output, and press
the Main Power button & the DC button ( USB) at the same
time to enter the switching frequency menu
2. Press the AC output button to switch the frequency, the
setting frequency will be flashing.
3. Long press the Main Power button to set the frequency,
SUC will be displayed if the setting is successful, and then
long press the main power button to exit the settings
menu.

• The Compagny is not responsible for any damage caused
by force ma jeure ( e.g. fire, typhon, flood, earthquake
or customer’s negligence, abuse or use in other unusual
circumstances)
• The compagny is not responsible for the loss caused by the
use of non-standard connector
• The compagny is not responsible for any damage caused by
the wrong operation which didn’t follow the instructions of user
manual
STORAGE AND MAINTENANCE
DISCLAIMER
FAULT CODE AND TROUBLE SHOOTING
• When the device is not in use , please turn off all switches to
reduce product power consumption and extend the product
battery lifetime.
• Please keep the surface of the product clean, ensure the the
product is not in contact witht gasoline, volatile oil, tinner,
kerosene, etc., to avoid corrosion of the product shell.
• Please store the product in a dry, ventilated and dustless
environment, in a 0-40° C temperature range and avoid direct
sunlight
• Please fully charged the battery before storage, and charge
it at least once every 3~6 months, to avoid dormancy of the
battery , which could affect the battery capacity progressively.
• If the product needs to be long-distance transported, please
keep the battery power between 40%~60%, otherwise there
could be a potential safety risk.
CODE DESCRIPTION PERFORMANCE TROUBLE SHOOTING
E000 AC Short Circuit
Protection
Flashing, no output
Press the AC Out put Power
ON/OFF button for recovery.
E001 Over Load
Production
Flashing, no output
Flashing icons indicate
with circuit overload. Press
corresponding button for
recorvery
E002
Battery low
Voltage
Protection
The function icon
blinks, and the
corresponding port
has no output
Press corresponding button
for recovery.
E003
AC&DC
Output run
simultaneously,
system
overload
Flashing, AC no
output
AC&DC Output run at the
same time, the total load
power is over 2400W. Shut
down the AC output, or lower
down the load of AC output,
priority support the DC output
E004 Inverter Fault
Flashing, no output
Inverteroutput voltage is
too high/ low ; Inverter over
temperature.
DC main line voltage too
high/ low ; Loaded current
abnormal.
E005 BMS FAULT
Flashing, other
function icons can’t
lit up, no output
• Charge over voltage
protection
• Discharge under voltage
protection
• High Temperature
Protection
• Low Temperature
Protection
• Short Circuit Protection.
AC
AC
AC
AC
DC
+ +
+
+

Sunslice SRL
Chemin du Cyclotron 6,
1348 Louvain-la-Neuve, Belgique
OUR WARRANTIES
The Gravity has a 2 year warranty. In case
something goes wrong, please contact us
directly by email at :
The Sunslice Gravity is equipped with
a voltage stabilizing circuit to avoid
damaging your devices.
We select the finest materials to insure a
high quality and durability for all of our
products.
RoHS
PREMIUM
QUALITY
PROTECTION
CIRCUIT
2 YEARS
WARRANTY
service@sunslice-solar.com
Before contacting us, please have a look at our FAQ at :
www.sunslice-solar.com/apps/help-center
PRECAUTIONS
www.sunslice-solar.com
You are welcome on our website to learn more
about our products.
• Please turn off all the switchs when it’s not used.
• If the Gravity does not charge your laptop or device, please
read this user manual again. If the problem lasts, please
contact us.
• The Gravity 2232 is not allowed in the plane.
• Do not puncture, throw, drop, bend or modify your Sunslice
Gravity.
• Do not leave the Sunslice Gravity out in the rain, keep away
from water. Do not expose the Gravity to fire or excessive heat.
• Do not short-circuit the battery with lead or any metal objects.
• Keep the battery ports free from dust, lint, etc that may
prevent proper connections.
• Please fully charge the powerbank after a long period of
storage as it may discharge slowly with time.
• If regularly used with solar panels, it is good to charge the
Gravity completely on the mains sometimes.
• Do not use excessive force when connecting or disconnecting
cables to/from the Gravity.
• Stop using the Sunslice Gravity if it generates unusual smell,
heating, distortion or any other abnormality.
• Keep away from children.
• Please use our standard solar panels and adapters to
charge the device, otherwise the device may not be charged
normally. In severe cases, the lifespan will be reduced, and the
device may be damaged due to short circuit.
• There will be efficiency loss of the input power which
displays on the LDC screen
• Please charge the product at the ambient temperature of
0~40°C
• Must make sure that the connection is in good contact, and
adapter work normally, otherwise, it may cause potential safty
hazards.
Table of contents
Other SUNSLICE Batteries Pack manuals