8. How To Bypass (Isolate) Zones
• Enter [User Code] [6] to get into isolate mode. The On-Line, Low Batt, AC Fail and On lights will come on.
• Any zone lights that are on indicate that the corresponding zone is bypassed.
• Enter the number of the zone to bypass to toggle it on / off.
• Press [∗] to exit isolate mode.
9. How To Clear Bypasses
• Bypasses are automatically cleared when the panel is disarmed.
• Alternatively enter bypass mode and manually toggle the bypasses for the required zones.
• Press [∗] to exit.
10. How To View Trouble
• If a low battery or AC fail occur then there corresponding lights will light on the keypad.
• If a fail to communicate occurs then the on-line light will flash.
• To see other events that may have occurred see “How To View Memory”
11. How To Clear Trouble
• If an AC fail has occurred check mains wiring / fuse.
• If a low battery fault occurs check the battery voltage and the battery fuse. If the AC has been off
recently, the battery may need to be recharged.
• If a fail to communicate occurs check the phone line wiring.
12. How To Exit From Trouble
• Press [∗] to exit review mode.
13. How To Recognise That The Chime Function (Home Beep) Is On
• When home-armed the keypad will give a beep every time a home-beep zone is tripped. If the home
squawk option is enabled the siren will also give a short burst each time a home-beep zone is
triggered.
14. How To Turn On Chime
• Home-beep zones are defined in the zone programming and can only be turned on / off by entering
programming.
• Enter [Installer Code] [7] [Address of zone for option group 2]. (Addresses start at 224 for zone 1 and
increase by 2 for each zone)
• Press [2] to toggle the home-beep option on / off for that zone.
• Enter the next zone address or press [∗] to exit programming.
15. How To Turn Off Chime
• Home-beep zones are defined in the zone programming and can only be turned on / off by entering
programming.
• Enter [Installer Code] [7] [Address of zone for option group 2]. (Addresses start at 224 for zone 1 and
increase by 2 for each zone)
• Press [2] to toggle the home-beep option on / off for that zone.
• Enter the next zone address or press [∗] to exit programming.
16. How To Send Keypad Panic Alarms
• Enter a user code followed by [1] (or press [#] [1]) to send a Panic signal.
• Enter a user code followed by [2] (or press [#] [2]) to send a Duress signal.
• These inputs need to be programmed at addresses 086 and 088. Also check that account codes,
phone numbers, and reporting codes have been programmed.
User Codes
17. How To Add User Codes
• User codes are added through programming. User code 0 is the master code, and user code 1 is the
installer code. User codes 2 through 7 have full access, and user codes 8 through 15 are arm/ disarm
only.
• Enter [installer code] [7] [Address of the user code] (User code addresses start at 000 for code 0, 004
for code 1, 008 for code 2, etc)
• If a code is already stored in that address it will be shown one digit at a time. The keypad will give a
beep.
• Enter the new code, or press [∗] to enter a new address.
• Press [∗] to exit programming.
18. How To Delete User Codes
• User codes are added through programming. User code 0 is the master code, and user code 1 is the
installer code. User codes 2 through 7 have full access, and user codes 8 through 15 are arm/ disarm
only.