Preface
Thank you very much for your purchase!
This manual covers safety precaution, technical specification, operation interface, installation&
connection, function&operation and so on. In order to make the product running at its best, please read this
manual in advance, and reserve it for the future reading.
The continuous technology update, function improvement and quality enhancement may lead to some
differences between this manual and the physical product, please understand.
Without our authorization, the contents of this manual are not allowed to be copied and reproduced.
Main Features:
Suitable for Ration Belt Weighfeeder with Ration Flow Feeding & Ration Weight Batch Control.
EMC design with high anti-jamming capability, suitable for industrial environment.
128×64 LCD display screen with 7 background colors for English/Chinese display.
Menu&Shortcut mode operation with key tone.
Optional English keypad, Simplified Chinese keypad and Complex Chinese keypad.
High-precision ∑-△A/D conversion technology and broad-range speed pulse input circuit.
Max. Connection Quantity: 8 Loadcells (350Ω).
Auto-locking, Key-locking, Key-unlocking, Digital Setting&Calibration and I/O Testing
functions available.
Auto Zero Tracking, Speed Calibration and Belt Length Calibration functions available.
One optional ‘Flow Setpoint’ analog signal input [AI: 4~20mA].
Max.3 definable ‘Flow/Control Current /…’analog signal outputs [AO: 4~20mA].
Quick and steady PID for ration feeding control available.
3 Definable normally open switch inputs [DI] and 4 definable normally open relay switch
outputs [DO].
The feeder and belt weigher can be started and stopped by DI&DO signal.
1 ‘Totalized Weight High-speed Pulse’output [PO].
2 Optional communication ports for linking to IPC/PLC, LED Remote Display, Serial Printer
and Wireless Module.
Weight Records per shift/day/month of a year can be queried and printed.
With the multitasking mode, the weighing&control process will not be interrupted by parameter
setting and the other operations.

2
Contents
1. SAFETY PRECAUTION.................................................................................................................4
2. TECHNICAL SPECIFICATION ....................................................................................................5
3. OPERATION INTERFACE ............................................................................................................7
3.1 OPERATION INTERFACE DIAGRAM.........................................................................................................7
3.2 KEYPAD OPERATION..............................................................................................................................8
3.3 STATE INDICATION.................................................................................................................................9
4. INSTALLATION&CONNECTION..............................................................................................10
4.1 INSTALLATION.....................................................................................................................................10
4.2 TERMINAL........................................................................................................................................... 11
5. OPERATION PROCEDURE ........................................................................................................15
6. FUNCTION&OPERATION..........................................................................................................16
6.1 MAIN DISPLAY INTERFACE ..................................................................................................................16
6.1.1 Totalized Weight, Flow & Belt Speed .......................................................................................16
6.1.2 Totalized Weight, Flow & Flow Setpoint ..................................................................................16
6.1.3 Totalized Weight, Flow & Control Current ...............................................................................17
6.1.4 Totalized Weight, Load & Load Setpoint ..................................................................................17
6.1.5 Totalized Weight, Date & Time .................................................................................................18
6.1.6 Totalized Weight, Batch Weight & Batch Weight Setpoint........................................................18
6.1.7 Alarm Items...............................................................................................................................19
6.1.8 DI&DO......................................................................................................................................20
6.1.9 AI&AO......................................................................................................................................20
6.1.10 AD Value, Totalized Weight Pulse, Total Weight of Present Shift...........................................20
6.2 MAIN MENU......................................................................................................................................21
6.3 F1 SETTING.........................................................................................................................................23
6.3.1 Basic Scale Parameters..............................................................................................................23
6.3.2 Extra Scale Parameters..............................................................................................................24
6.3.3 Basic Control Parameters..........................................................................................................25
6.3.4 Extra Control Parameters ..........................................................................................................26
6.3.5 Flow Parameters........................................................................................................................27
6.3.6 Speed Parameters ......................................................................................................................28
6.3.7 Load Parameters........................................................................................................................29

3
6.3.8 Weight Record Parameters ........................................................................................................29
6.3.9 Communication Parameters.......................................................................................................30
6.3.10 I/O Parameters.........................................................................................................................31
6.3.11 Display Parameters..................................................................................................................33
6.3.12 Date/Time Parameters .............................................................................................................33
6.3.13 ASample of Parameter Setting................................................................................................34
6.4 F2 SYSTEM CALIBRATION ...................................................................................................................35
6.4.1 Zero Calibration ........................................................................................................................35
6.4.2 Dynamic Span Calibration ........................................................................................................36
6.4.3 Static Span Calibration with Chain Weight ...............................................................................37
6.4.4 Static Span Calibration with Hanging Weight...........................................................................39
6.4.5 Segmenting Span Correction.....................................................................................................41
6.4.6 Speed Calibration......................................................................................................................43
6.4.7 Belt Length Calibration.............................................................................................................44
6.5 F3 WEIGHT RECORD FOR QUERYING&PRINTING ................................................................................45
6.6 F4 DATA CLEARING.............................................................................................................................46
6.7 F5 SECURITY.......................................................................................................................................47
6.7.1 Auto-locking..............................................................................................................................47
6.7.2 Key-locking...............................................................................................................................48
6.7.3 Key-unlocking...........................................................................................................................48
6.7.4 Password Set..............................................................................................................................49
6.7.5 RAM Reset................................................................................................................................50
7. RATION FLOWAUTO-FEEDING SYSTEM.............................................................................51
APPENDIXA. PRINT FORMATS ...................................................................................................52
APPENDIX B. COMMUNICATION PROTOCOLS......................................................................53

4
1. Safety Precaution
Lithium Battery Installation
A Lithium battery should be equipped in the product. If it is not allowed to be transported
together with the product because of embargo, please make a purchase according to the
model offered by us and install it by yourself.
Prohibit using the product under dangerous environment
Prohibit using the product under the dangerous environment with combustible gas and
explosive dust. If you have this need, please use our explosion-proof products.
Avoid using the product under overheated environment
Make sure that the product works under the environment with allowed temperature range to
get good performance and long working life.
Please keep the product away from direct sunlight. If it is installed in a cabinet, please install
cooling fans on the top of the cabinet.
Controller Grounding Protection
The product, as a low-voltage equipment, should be kept away from the high-voltage
equipments.
For avoiding bodily injury from electric shock accident and keeping the product separate from
strong interference, the shell of the product should be grounded directly and the ground
resistance should be less than 4Ω.
Scale Frame Grounding Protection
For avoiding bodily injury from electric shock accident and keeping the loadcells and speed
sensor separate from strong interference, the scale frame should be connected with the
electronic scale grounding net and the ground resistance should be less than 4Ω.
Cable Laying
Weighing signal, speed signal, analog signal and communication signal cables should be laid
in pipes, and do not lay them together with power cables.
Power Supply
Please make sure that the inputted voltage is correct before power-on.
Environmental Protection
Before the Lithium battery equipped in the product being discarded, please insulate its
positive or negative pole, do not put it into fire.
Although the product is made of the lead-free components, after used in the industrial
environments, it’s possible to be polluted. So, while being discarded as worthless, the product
should be processed lawfully as leady industrial waste for environment protection.
Other Notes
The installation, wiring and maintenance should be operated by the engineers with the
relevant professional knowledge and safety operation ability. Although being not described in
this manual, the relevant safety operating procedures and standards should be followed.

5
2. Technical Specification
Executing Standard
CMC GB/T 7724-2008《Electronic Weighing Meter》PRC National Standard.
OMIL R50:1997《Continuous Totalizing Automatic Weighing Instruments》International
Recommendation.
Accuracy Grade: 0.5.
Display
128×64 LCD display screen with 7 background colors for English/Chinese display.
Display Refreshing Time: Setting Range 0.1~2.0s.
Kaypad
Optional 16-key English keypad, Simplified Chinese keypad and Complex Chinese keypad.
Menu&Shortcut operation with key tone.
Loadcell Interface
Excitation Voltage/Max. Current: DC10V/250mA [8-350Ω loadcells].
Signal Input Range: 0~25mV.
∑-△ADC: 24-bit, 100,000 internal code used.
Sampling Frequency: 200Hz.
Zero Drift: ±0.1μV/℃RTI (Relative to Input).
Gain Drift: ±5ppm/℃.
Non-linearity: 0.005%FS.
Speed Sensor Interface
Output Voltage/Max. Current: DC12V/100mA.
Speed Pulse Input Range: 0.5~3000Hz.
Switch Signal Interface
3 Normally Open Switch Inputs [DI].
4 Normally Open Relay Switch Outputs [DO]: AC250V/DC24V, 1A.
1 ‘Totalized Weight High-speed Pulse’ Output [PO]: 100mA, DC5~24V; Weight per Pulse and
Pulse Width can be preset.
Analog Signal Interface
Max.3 Definable ‘Flow/Control Current /…’ Analog Signal Outputs [AO]: 4~20mA, Non-linearity:
0.05%FS; AO3 is optional.
1 Optional ‘Flow Setpoint’Analog Signal Input [AI]: 4~20mA, Non-linearity: 0.05%FS.
Digital Communication Interface
COM1: Optional RS232/RS485/RS422/Profibus-DP/Ethernet modules.
COM2: RS232.

6
Connectable: IPC/PLC, LED Remote Display, Serial Printer and Wireless Module.
Report Print
Weight Records per shift/day/month of a year can be queried and printed.
Operating Specification
Operating Voltage: DC24±20%.
Max. Power Consumption: 10W.
Outline Size: 288×95×189mm [W×H×D].
Panel Cut-out Size: 281×88mm [W×H].
Operating Temperature: -20℃to +40℃.
Storage Temperature: -30℃to +60℃.
Relative Humidity: Max. 85%RH.
Protection Level of Front Panel: IP65.
Weight: Approx. 1.4kg.

7
3. Operation Interface
3.1 Operation Interface Diagram
Flow:19.9t/h
Speed: 0.35m/s
4800000kg
RUN
AUTO
EXT
ALARM
LOCK
1
SET
2
ADJ-
3
ADJ+
4
AUTO F1 MENU
5
EXT
6
ZERO
7
CAL
▲
LOCK
8
CLS
9
REC
0
PRINT
▼
ENT

8
3.2 Keypad Operation
If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 Calibration’ & ‘F6 Factory
Adj.’, the controller will return to ‘Main Display Interface’ automatically.
Menu Operation
Key Name Description
【MENU】
(【ESC】)
Enter Main Menu.
Exit.
【ENT】Enter/Save.
【▲】Cursor shifts up or left.
Display the previous interface or option.
【▼】Cursor shifts down or right.
Display the next interface or option.
【0~9】Digit Input.
Quick Operation
【LOCK】Key-locking.
Key-unlocking.
【F1】Return to the initial display interface.
【SET】Flow Set Value Setting.
【ADJ-】Control Current -1mA.
【ADJ+】Control Current +1mA.
【AUTO】‘Manual/Auto’Control Mode Selection.
【EXT】‘Internal/External’ Flow Set Mode Selection.
【ZERO】Zero Calibration.
【CAL】Dynamic Span Calibration.
【CLS】Clear Screen: Clear display value of Totalized Weight.
【REC】Query and print Weight Record.
【PRINT】Print.

9
3.3 State Indication
LED Lamp Description
[RUN] ON: Weighing state.
OFF: Stopping state.
[AUTO]
Feeding control mode:
ON: Auto [PID].
OFF: Manual.
[EXT]
Flow Set Mode:
ON: External [AI: 4~20mA].
OFF: Internal.
[ALARM] Alarm.
[LOCK] ON: Key-locked.
OFF: Key-unlocked.

10
4. Installation&Connection
4.1 Installation
Outline Size
W×H×D[mm]
Front Panel Size
W×H[mm]
Box Body Size
W×H[mm]
Panel Cut-out Size
W×H[mm]
288×95×189 288×95 280×87 281×88
Installation Mode
Outline Size
189
Front Panel Size
288
95
(87)
(280)
Panel Cut-out Size
281
88

11
4.2 Terminal
DO/DI
DO1+
DO1-
DO2+
DO2-
DO3+
DO3-
DO4+
DO4-
COM
DI1
DI2
DI3
1 2
3 4
5 6
7 8
9 10
11
12
POWER SENSOR
SIG-
SIG+
EXC-
EXC+
SHD
VS-
SIN
DS+
SEN+
SEN-
B-/TXD-
A+/TXD+
RXD+
RXD-
GND
GND
RXD
TXD
+5V
AO/AI/PO
AO1+
AO1-
AO2+
AO2-
AO3+
AO3-
AI+
AI-
VIN
PO
DC-
DC+
COM1 COM2
1 2
1 2
3 4
5 6
7 8
9 10
1 2
3 4
5 6
7 8
9 1 2
3 4
5 6
7 8
9 10
ETHERNET
PROFIBUS-DP

12
No. Pin Description
SENSOR Loadcell / Speed Sensor Port
LOADCELL Loadcell
Connection Mode 6-Wire 4-Wire
[Default Set]
1 SEN+ Feedback Voltage +.
2 SEN- Feedback Voltage -.
3 SIG- Weighing Signal [mV]Input -. Weighing Signal [mV]Input -.
4 SIG+ Weighing Signal [mV]Input +. Weighing Signal [mV]Input +.
5 EXC- Excitation Voltage -. Excitation Voltage -.
6 EXC+ Excitation Voltage + [DC10V]. Excitation Voltage + [DC10V].
7 SHD Shield Ground. Shield Ground.
SPEED
Speed Sensor
3-Wire
[NPN Open-collector Output Type] 2-Wire Tachogenerator
8 VS- Voltage Output -. Pulse Signal Input -.
9 SIN Pulse Signal Input. Pulse Signal Input +. Sine Wave Signal Input
Terminal 1.
10 VS+ Voltage Output + [DC12V]. Sine Wave Signal Input
Terminal 2.
POWER DC24V[±20%] Power Input Port
1 DC- DC Input -.
2 DC+ DC Input +.
The shell should be grounded directly to avoid electric shock.

13
No. Pin Description
COM1/2 COM1/COM2 Digital Communication Port
COM2
[Wiring Terminal] RS232 Digital Communication Port
1
2
3
4
5
6 GND Signal Ground / Shield Ground.
7 RXD Receive Data.
8 TXD Transmit Data.
9 +5V +5V/100mAOutput.
COM1 RS232/RS485/RS422/Profibus-DP/Ethernet Digital Communication Port
[It's optional to configure one of them]
Wiring Terminal RS232 RS485 RS422
1 B- TXD-
2 RXD A+ TXD+
3 TXD RXD+
4 RXD-
5 GND GND GND
6
7
8
9
Profibus-DP
[DB9 Socket] Profibus-DP
1 DP- [B-] Data -.
3 DP+ [A+] Data +.
RJ45[DCE] Socket Ethernet
[T568B Wiring Mode]
1 RXD+ Orange-white
2 RXD- Orange
3 TXD+ Green-white
4
Unused
Blue
5 Unused Blue-white
6 TXD- Green
7 Unused Brown-white
8 Unused Brown

14
No. Pin Description
AO/AI/PO Analog Output / Analog Input / High-speed Pulse Output Port
AO Analog Output Port [Definable]
1 AO1+ 4~20mA Output 1 [+/-].
2 AO1-
3 AO2+ 4~20mA Output 2 [+/-].
4 AO2-
5 AO3+ 4~20mA Output 3 [+/-].
[It's optional to configure it].
6 AO3-
AI Analog Input Port
7 AI+ 4~20mAInput +.
8 AI- 4~20mAInput -.
PO Totalized Weight High-speed Pulse Output Port
9 VIN DC5~24V Input.
10 PO Totalized Weight High-speed Pulse Output.
No. Pin Description
DO/DI Relay Switch Signal Output / Switch Signal Input Port
DO Relay Switch Signal Output [Definable]
1 DO1+ Normally Open Contact Output 1 [+/-].
2 DO1-
3 DO2+ Normally Open Contact Output 2 [+/-].
4 DO2-
5 DO3+ Normally Open Contact Output 3 [+/-].
6 DO3-
7 DO4+ Normally Open Contact Output 4 [+/-].
8 DO4-
DI Switch Signal Input [Definable]
9 COM DI Common Terminal [GND].
10 DI1 Switch Signal Input 1.
11 DI2 Switch Signal Input 2.
12 DI3 Switch Signal Input 3.
Contact Capacity of Relay Switch: AC250V/DC24V, 1A.

15
5. Operation Procedure
Connection & Power on
Zero Calibration
I/O Setting
Serial Port Setting
Control Setting
(Used for belt feeder)
Other Settings
‘Weighing Dead Band’ Setting
(Scale Setting)
Key-Locking
‘Speed Coeff.’ & ‘Belt Length’
Setting (Scale Setting)
Dynamic Span Calibration
Or Static Span Calibration

16
6. Function&Operation
The following display&operation interfaces are described with ‘kg’ as the Internal Scale Unit. If the
parameter ‘[P107] Internal Scale Unit’is set to ‘g’, the actual Weight Display Unit will be different.
6.1 Main Display Interface
【▼】【 ▲】: Display the next/previous interface.
6.1.1 Totalized Weight, Flow & Belt Speed
Press【PRINT】key to print: 2009-05-20 23:59
4800000kg
6.1.2 Totalized Weight, Flow & Flow Setpoint
0020.00[t/h]
R: 0.00-5000.00
P200 Flow Set
Flow[↑↓]: 19.9t/h
Set: 20.0t/h
4800000kg
【ENT】: Set ‘Flow Setpoint’value
↑: Upper Limit
↓: Lower Limit
Flow[↑↓]: 19.9t/h
Speed[↑↓]:0.35m/s
4800000kg

17
6.1.3 Totalized Weight, Flow & Control Current
6.1.4 Totalized Weight, Load & Load Setpoint
Load=Flow / (3.6×Speed)
Load Setpoint=Flow Setpoint / (3.6×Speed)
Load: kg/m
Flow: t/h
Belt Speed: m/s
Load[↑↓]: 15.8kg/m
Set: 15.9kg/m
4800000kg
12.26[mA]
R: 4.00-20.00
Control Current
Flow[↑↓]: 19.9t/h
Ctrl[↑↓]: 12.26mA
4800000kg
【ENT】: Set ‘Control Current’value
【ADJ-】【 ADJ+】: Control Current ±1mA

18
6.1.5 Totalized Weight, Date & Time
6.1.6 Totalized Weight, Batch Weight & Batch Weight Setpoint
2009-05-20
23:59:45 Wed.
4800000kg
Month-Day-Year
Hour: Minute: Second Week
Batch[↑]: 0kg
Set: 0kg
4800000kg
00000000[kg]
R: 0-99999999
P217 Batch Set
【ENT】: Set ‘Batch Weight Setpoint’value
↑: Batch
End (Totalized Weight
reaches to Batch Weight Setpoint)

19
6.1.7 Alarm Items
Alarm Item Alarm Condition
Flow Upper Limit Flow ≥Flow Range × Flow Upper Limit(%)
Flow Lower Limit Flow ≤Flow Range × Flow Lower Limit(%)
Load Upper Limit Load ≥Load Range × Load Upper Limit(%)
Load Lower Limit Load ≤Load Range × Load Lower Limit(%)
Speed Upper Limit Speed ≥Speed Range × Speed Upper Limit(%)
Speed Lower Limit Speed ≤Speed Range × Speed Lower Limit(%)
Control Current Upper Limit Control Current ≥PID Control Current Upper Limit
Control Current Lower Limit Control Current ≥PID Control Current Lower Limit
Flow Positive Deviation Limit Flow Deviation [E%] > Flow Positive Deviation Limit
Flow Negative Deviation Limit Flow Deviation [E%] < Flow Negative Deviation Limit
Flow Deviation Value [E%]
XXX.X%
Flow Deviation [E%] = ((Flow -Flow Setpoint) / Flow
Setpoint) × 100%
OK: Normal
HI: Upper Limit / Positive Deviation Limit
LO: Lower Limit / Negative Deviation Limit
Flow:OK Load:OK
Speed:OK Ctrl: OK
Dev:OK -0.5%
Alarm Items
Table of contents
Other Supmeter Controllers manuals

Supmeter
Supmeter BST100-B11 User manual

Supmeter
Supmeter BST106-M10 User manual

Supmeter
Supmeter BST100-E11 User manual

Supmeter
Supmeter BST106-M10(GH) User manual

Supmeter
Supmeter BST106-F19 User manual
![Supmeter BST106-B60[A] User manual Supmeter BST106-B60[A] User manual](/data/manuals/1s/q/1sqb6/sources/supmeter-bst106-b60-a--manual.jpg)
Supmeter
Supmeter BST106-B60[A] User manual

Supmeter
Supmeter BST106-B60S(L) User manual

Supmeter
Supmeter BST106-M10 User manual
Popular Controllers manuals by other brands

Federal Signal Corporation
Federal Signal Corporation SS2000+ ? Series Operation manual

Loctite
Loctite 2257357 operating manual

Emerson
Emerson Level-Trol 2500 Series instruction manual

YASKAWA
YASKAWA YRC1000 instructions

Siemens
Siemens HydroRanger 200 HMI operating instructions

Alpha IP
Alpha IP TD 61001 Series manual