2021/03/11 15:37 1/2 How to Configure XPass D2
- http://kb.supremainc.com/knowledge/
System Configuration, BioStar 2, XPass D2
How to Configure XPass D2
XPass D2 is a new device introduced with BioStar 2.6.
It is a dummy reader for reading cards, which means it doesn’t perform data matching on the device.
The device can be used as slave device, or a Wiegand reader to send Wiegand output.
The device sends out a Wiegand signal with the default 26bit format and the Wiegand configuration
will be done with a separate tool Device manager.
Please refer to the article : How to use Suprema Device Manager App
Adding as a Slave Device
You will need a master device to add the slave D2 device.
Refer to the article below to learn how to search a slave device.
RS485 Mode (Master, Default, Slave)
Using the device as a Wiegand Reader
If you have already used the device as a slave device before, you must reset the device to use it as a
Wiegand reader (sending Wiegand output).
1. Delete the device from BioStar 2 client as a slave device.
2. Detach the metal bracket from the device.
3. Press the reset button.