suprema Xpass S2 User manual

Xpass S2
EN 101.00.XPS2 V1.11
www.supremainc.com
Installation Guide
Intelligent IP Access Control Reader

ⒸCopyright 2007Suprema Inc.
Xpass S2
2
Important Safety Information
Carefully review the information within the user manual before installing or operating the device.
Pay careful attention to the warning and cautions below as they are here to prevent any risk or damage
to any person(s) or property associated with the device.
Warning
Failure to heed these warnings may lead to serious
injury or even death!
Caution
Failure to heed these cautions may lead to minor injury
or damage the device.
Installation
Do not install the device near heat sources such as radiators,
heat registers, and stoves.
Do not install the device near areas of large electromagnetic
interference.
Installation
Do not leave cables (especially power cables) exposed to
the outer environment.
Do not install the device near objects with a strong magnetic
field such as magnets, computer monitors (especially CRT),
TV screens and speakers.
Use a separate power supply for Secure I/O 2, electric lock
and Xpass S2 respectively. If connecting and using the power
supply to these devices together, the devices may
malfunction.
Usage
Do not disassemble, repair or reconstruct the device.
Disassembling the device will void the warranty.
Only use the device its intended use.
Contact your nearest Suprema dealer for technical support.
Usage
Do not drop or apply any physical shock/impact to the device.
Regularly clean the product with a soft dry cloth; avoid
benzene or alcohol.

ⒸCopyright 2007Suprema Inc.
Xpass S2
‹#›
Product Components
Optional Accessories
Name of Each Part
LED Status
Reset Network Settings
Product Dimension
Cables and Connectors
Power Connection
LAN Connection
RS485 Connection
Relay Connection
Digital Input Connection
Wiegand Input/Output
Installation of Wall-mount Bracket
Installation of Extended Bracket
Installation Reference
Specification
Electrical Specification
FCC Rules
Contents
4
5
6
7
8
9
10
11
12
14
16
19
21
22
23
24
27
28
29

ⒸCopyright 2007Suprema Inc.
Xpass S2
4
Product Components
Xpass S2 Wall Bracket
Wall Mounting Screws
(2 ea)
Screw Anchors
(2 ea)
Shrinkable Tubes Software CD Diode
(1 ea)
Basic Components

ⒸCopyright 2007Suprema Inc.
Xpass S2
5
Optional Accessories
Secure I/O Plastic Stand
Extended Bracket 12VDC Adaptor

ⒸCopyright 2007Suprema Inc.
Xpass S2
6
Name of Each Part

ⒸCopyright 2007Suprema Inc.
Xpass S2
7
LED Status
LED Status by Color
Color Sound Description
Green Beep x 3 Authorization Success
Red Long Beep Authorization Fail
Pink Short Beep On Processing
Flicker Blue/Skyblue Color per 2 sec N/A Normal
Flicker Red/Pink Color per 2 sec N/A Locked
Flicker Blue/Red Color per 2 sec N/A Initialized Time due to the
Internal Battery Discharge
Flicker Blue/Yellow Color per 2 sec N/A IP address is not assigned when
terminal is set as Use in the
DHCP of TCP/IP setting
For first operation, red LED is blinking
by every 2 seconds. N/A Failed. Please contact to your
distributor or Suprema
For normal operation, red LED is
blinking by every 2 seconds. N/A Security Status
Yellow LED is blinking shortly. N/A
Terminal is used or received a
packet to get IP address when
terminal is set as Use in the Idle
status or TCP/IP Setting

ⒸCopyright 2007Suprema Inc.
Xpass S2
8
When you install the Xpass S2 or forget the network setting’s value of Xpass S2 in use, can initial the
network setting’s value (TCP/IP address, RS-485 setting) in the switch of Xpass S2’s back side as follows;
Reset Network Settings
Reset Network Settings
1. Press the Reset button located on the rear of the Xpass S2 for 3 seconds or more.
2. Use the BioStar (Ver. 1.8 or higher) to connect to the Xpass S2 using the default
settings.
Default Network Settings:
-IP Address (Static): 192.168.0.1
-Use Server: Disabled
-RS485: PC Connection, 115200bps
3. Enter the desired IP address or RS485 settings and save the new settings.
4. Remove the Xpass S2 from the device list and reconnect to the device using the
new network settings.
TCP/IP Status LED
Green LED blinks shortly: Displaying connection status by TCP/IP
Red LED blinks shortly: Displaying data transfer stauts by TCP/IP

ⒸCopyright 2007Suprema Inc.
Xpass S2
9
Product Dimension
(unit: mm)
< Extended bracket >< Front View > < Wall Bracket >< Side View >

ⒸCopyright 2007Suprema Inc.
Xpass S2
10
Cables and Connectors
Pin Pin Name Description Color
1WG GND Wiegand Ground
2TTL GND Switch Ground
3485 GND RS485 Ground
4WG D0 Wiegand Data 0
5WG D1 Wiegand Data 1
6TTL IN0 Switch Input 0
7TTL IN1 Switch Input 1
8485 TRXP RS485 TRX+
9485 TRXN RS485 TRX-
Pin Pin Name Description Color
10 ENET TXN ETH TXN (LAN)
11 ENET TXP ETH TXP (LAN)
12 ENET RXN ETH RXN (LAN)
13 ENET RXP ETH RXP (LAN)
14 PWR GND Power Ground
15 RLY NO Relay Normal Open
16 RLY COM Relay Common
17 RLY NC Relay Normal Close
18 PWR +VDC Power In
7
15
1 2 3 4 5
161718
6 8 9
10 11 12 13 14

ⒸCopyright 2007Suprema Inc.
Xpass S2
11
Power Connection
Pin Pin Name Color
18 PWR +VDC Red
14 PWR GND Black (White Stripe)
•12VDC ±10%, at least 1500mA.
•Comply with standard IEC/EN 60950-1.
•Use a separate power supply for Secure I/O, electric lock and Xpass S2 respectively. If connecting and using
the power supply to these devices together, the devices may malfunction.
Recommended power supply
Xpass S2
18
14

ⒸCopyright 2007Suprema Inc.
Xpass S2
12
LAN Connection
Ethernet Connection (Connection with HUB)
The device can be connected to a network using a regular Ethernet hub.

ⒸCopyright 2007Suprema Inc.
Xpass S2
13
LAN Connection (Direct connection with PC)
Ethernet Connection (Direct connection with PC)
Use a standard CAT-5 cable to connect the device directly to a PC.

ⒸCopyright 2007Suprema Inc.
Xpass S2
14
RS485 Connection for Host Communication
Pin Pin Name Color
8485 TRXP Blue (White Stripe)
9485 TRXN Yellow (Black Stripe)
3485 GND White (Black Stripe)
Xpass S2
Xpass S2
Notes
−Only the devices at the both ends of the bus should be terminated. To enable termination on the RS232-485 converter,
refer to the converter’s manual.
−Adjust the communication speed as needed. The signal quality vary depending on wiring conditions, and it may be
necessary to lower the Baud rate.
−The GND signal may be omitted if and only if the GND potential difference is less than ±5V.
8
9
3

ⒸCopyright 2007Suprema Inc.
Xpass S2
15
RS485 Connection for Secure I/O
Pin Pin Name Color
8485 TRXP Blue (White Stripe)
9485 TRXN Yellow (Black Stripe)
3485 GND White (Black Stripe)
Max number of devices
Maximum eight (8) devices (including Master) interworks in an RS485 loop.
8
9
3
8
9
3

ⒸCopyright 2007Suprema Inc.
Xpass S2
16
Relay Connection –Fail safe lock
Pin Pin Name Color
16 RLY COM Green (White Stripe)
17 RLY NC Orange (White Stripe)
Xpass S2
Take care of the direction of the diode.
Make sure to install the diode near to the door lock.
Make sure to use different power supplies for the Xpass S2 and the door lock.
Make sure to install the diode at both ends of the circuit as shown in the figure left in order
to protect the relay contact from the reverse current that occurs when the door lock works.
16
17

ⒸCopyright 2007Suprema Inc.
Xpass S2
17
Relay Connection –Fail secure lock
Pin Pin Name Color
15 RLY NO Gray (White Stripe)
16 RLY COM Green (White Stripe)
Take care of the direction of the diode.
Make sure to install the diode near to the door lock.
Make sure to use different power supplies for the Xpass S2 and the door lock.
Make sure to install the diode at both ends of the circuit as shown in the figure left in order
to protect the relay contact from the reverse current that occurs when the door lock works.
Xpass S2
15
16

ⒸCopyright 2007Suprema Inc.
Xpass S2
18
Relay Connection –Automatic Door
Pin Pin Name Color
15 RLY NO Gray (White Stripe)
16 RLY COM Green (White Stripe)
Xpass S2
15
16

ⒸCopyright 2007Suprema Inc.
Xpass S2
19
Digital Input Connection (Alarm, Emergency S/W)
Pin Pin Name Color
7TTL IN1 Brown
2TTL GND Gray
6TTL IN0 Purple
Xpass S2
7
2
6

ⒸCopyright 2007Suprema Inc.
Xpass S2
20
Digital Input Connection (RTE, Door Sensor)
Pin Pin Name Color
7TTL IN1 Brown
2TTL GND Gray
6TTL IN0 Purple
Xpass S2
7
2
6
Other manuals for Xpass S2
1
Table of contents
Other suprema Card Reader manuals

suprema
suprema bioentry PLUS User manual

suprema
suprema XPass D2 User manual

suprema
suprema WEBtec-4X Installation guide

suprema
suprema Xpass User manual

suprema
suprema XPass D2 User manual

suprema
suprema Xpass User manual

suprema
suprema X-station User manual

suprema
suprema XPass D2 User manual

suprema
suprema RealPass-F User manual