6. MOUNTING
Important! Before mountint the regulator, make sure that all fixing elements durable fastened
to the wall!
• For securely wall mounting it is necessary to determine the type of wall material (wood, brick,
concrete, drywall, and etc.) for corresponding fastener selection.
• Mounting stabilizer location should be close to the wall outlet, considering the stabilizer power
cord length (1.25 m ± 3%).
• Next, make a mounting fasteners (not included) to the wall, considering the wall mounting holes
location f on the stabilizer rear panel (see Fig. 3).
• Then hang the stabilizer on xing elements.
7 INSTALLATION
Attention! Before connecting the regulator, make sure that all consuming devices connect-
ed to the regulator are switched off and the switch iis in OFF position. The maximum cur-
rent of the circuit breaker must be not less, than the current of the circuit breaker of AVR.
For the VR-S3000 electrical connection should only be performed by a qualied technician.
Before installing the AVR, please make sure that total power of all consumers is lower than AVR output
power. Taking into account the starting loads and power factor of consumers, it is necessary to apply
power margin factor with the coefficient 1.2–1.5; but for such equipment as air conditioners, fridges,
etc., it should be 1.5–2.
Attention! When choosing an AVR, it is necessary to know that reduction of input voltage
increases an input current value, consequently, the maximum power of AVR is reduced too!
Such dependence is shown in the graph below:
Note. Adhere strictly to such dependence. If the condition stated above is not adhered to,
warranty servicing becomes void!
• Turn o the pre-using equipment and connect it to the stabilizer sockets.
• Plug the stabilizer power cord jin the wall outlet.
• Turn on stabilizer with switch i.
• The green indicator will light up, the red indicator will ash (load connection delay). At the same
time the digital indicator dwill display the expiration of the delay. The total delay makes 6 or 180
seconds depending on the "Pause" button (ON/ OFF) hposition.
• When the mains voltage exceeds the allowable rate (lower threshold is 140 V, upper threshold is
275 V) the LED c illuminates, the AVR disconnects the load automatically and the LED ddisplays
“L” or “H”.