2MS-12-38
Revision 2 10-03-CP
Components (Unit with Die Heads and Base)
Use safety glasses when setting up and
operating the AHSU.
Do not tamper with or alter any
components of the AHSU.
Return the AHSU to your independent
Swagelok sales and service representative
if any signs of hydraulic fluid leakage or
malfunction occur.
Safety Precautions
3. Select the proper size die head (reference the
size marked on each die head).
4. Remove the screw located in the bore of the
die head previously installed in the hydraulic
housing by turning counter clockwise with the
hex key.
5. Depress the nut retainer to remove the die head.
6. Depress the nut retainer and install the selected
die head. Tighten the shaft screw sufficiently to
keep the die tight, being careful not to break the
screw by overtightening it.
7. For 1/4 and 3/8 in. and 6, 8, and 10 mm sizes,
insert the appropriate adapter plate into the nut
retainer. Refer to the mark on the plate for size
information.
Safety glasses
Gap
inspection
gauge
Hex key
Nut retainer
Base Air input
decal
Air inlet
valve
Air pump
Indicator knob
set lever
Operating
instructions
Indicator knob
Die heads
Air input
Hydraulic housing
Adapter plates
Setup
1. Connect the appropriate air source to the AHSU
air inlet valve.
2. Adjust the source pressure to the value shown in
the table or on the air input decal for the tubing
material and size.
Air inlet pressure should be limited to less
than 90 psig (6.2 bar). If the inlet pressure
exceeds 90 psig, there is a pressure relief
valve in the unit that will activate.
Required Air Inlet Working Pressure, psig (bar)
Size Stainless Steel or
Steel Tubing
Brass or Soft
Copper Tubing
Fractional Series
400 40 (2.8) 35 (2.4)
600 60 (4.2) 35 (2.4)
810 70 (4.9) 45 (3.1)
Metric Series
6M0 40 (2.8) 35 (2.4)
8M0 50 (3.5) 35 (2.4)
10M0 60 (4.2) 40 (2.8)
12M0 70 (4.9) 45 (3.1)