SS-450-001 4 I56-3392-008R
©2012 System Sensor
System Sensor warrants its enclosed smoke detector base to be free from defects in mate-
rials and workmanship under normal use and service for a period of three years from date
of manufacture. System Sensor makes no other express warranty for this smoke detector
base. No agent, representative, dealer, or employee of the Company has the authority to
increase or alter the obligations or limitations of this Warranty. The Company’s obligation
of this Warranty shall be limited to the repair or replacement of any part of the smoke
detector base which is found to be defective in materials or workmanship under normal
use and service during the three year period commencing with the date of manufacture.
After phoning System Sensor’s toll free number 800-SENSOR2 (736-7672) for a Return
Authorization number, send defective units postage prepaid to: System Sensor, Returns
SS-450-001 1 I56-3392-008R
B200SR
Intelligent Sounder Base
INSTALLATION AND MAINTENANCE INSTRUCTIONS
3825 Ohio Avenue, St. Charles, Illinois 60174
1-800-SENSOR2, FAX: 630-377-6495
www.systemsensor.com
BEFORE INSTALLING
Please read the System Sensor Smoke Detector Application Guide, which pro-
vides detailed information on sensor spacing, placement, zoning, wiring, and
special applications. Copies of this manual are available from System Sensor.
NFPA 72 and NEMA guidelines should be observed.
NOTICE: This manual should be left with the owner/user of this equipment.
IMPORTANT: The detector used with this base must be tested and maintained
regularly following NFPA 72 requirements. The detector should be cleaned at
least once a year.
GENERAL DESCRIPTION
The B200SR sounder base is used with System Sensor 200-Series sensor heads
or equivalent. For a list of compatible sensors, refer to the System Sensor web-
site at www.systemsensor.com. Refer to the appropriate manual for more infor-
mation on sensors.
The B200SR sounder base was designed specifically to meet the needs of
dwelling unit applications. It offers maximum flexibility in configuration and
operation to meet or exceed the requirements of UL268 and UL464.
The sounder base is capable of producing either the distinctive three-pulse
temporal pattern (ANSI Temporal 3) fire alarm signal now required by NFPA
72 for commercial and residential applications or a continuous tone by simply
removing the included jumper from the device. Additionally, the B200SR is
designed to be compatible with existing installations of B501-Series sounder
bases.
The sounder base is intended for use with intelligent systems. The sounder
base requires an external 24 VDC power supply. The connections for the
external power supply and the communication loop are isolated to prevent
electrical interaction between them. Refer to the panel manual for maximum
allowable number of units per loop.
NOTE: For NFPA72 Installations, the Temporal 3 tone should be used for public
mode evacuation.
NOTE: When not used as a supplementary evacuation system, the external 24
VDC supply shall be treated as a component of the main power supply system
and shall fall under the requirements of the main power supply system per
NFPA 72.
Specifications
Base Diameter: 6.875” (17.46 cm)
Base Height (less sensor): 2.0” (5.08 cm)
Weight: 0.50 lb. (227 gm)
Operating Temperature Range: Refer to applicable sensor Operating Temperature Range using the Base/Sensor Cross Reference Chart at systemsensor.com
Operating Humidity Range: 10% to 93% relative humidity (non-condensing)
External Supply Electrical Ratings
External Supply Voltage: 16 to 33 VDC (VFWR)
Standby Current: 500 μA maximum
Alarm Current: 35 mA maximum
SLC Electrical Ratings
SLC Operating Voltage: 15 to 32 VDC
SLC Standby Current: 300 μA maximum
Sound Output Greater than 85 dBA minimum measured in a UL reverberant room at 10 feet, 24 Volts (in continuous tone)
WIRING GUIDELINES
All wiring must be installed in compliance with the National Electrical Code
and the local codes having jurisdiction and must not be of such length or wire
size which would cause the base to operate outside of its published specifica-
tions. The conductors used to connect smoke sensors to control panels and
accessory devices should be color coded to reduce the likelihood of wiring
errors. Improper connections can prevent a system from responding properly
in the event of a fire.
Wire sizes up to 12 AWG (2.5 mm2) may be used with the base. The sounder
base will be shipped with the screw terminals set for 14 AWG wiring. If 12
AWG wire is to be used, back out the screws to allow the wire to fit beneath
the clamping plates. For best system performance, the power (+ and -) wires
and the communication circuit wires should be twisted pair or shielded cable
installed in a separate grounded conduit to protect the communication loop
from electrical interference.
Make wire connections by stripping about 3/8” of insulation from the end of
the wire. Then, slide the bare end of the wire under the appropriate clamping
plate (See Figure 1), and tighten the clamping plate screw. Do NOT loop the
wire under the clamping plate (See Figure 2) The wiring diagram for a typical
2-wire intelligent system is shown in Figure 4.
CAUTION
For system monitoring - for terminals 4 and 5, do not use looped wire under termi-
nals. Break wire run as shown in Figure 2 to provide monitoring of connections.
THREE-YEAR LIMITED WARRANTY
Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174. Please include a
note describing the malfunction and suspected cause of failure. The Company shall not
be obligated to repair or replace units which are found to be defective because of damage,
unreasonable use, modifications, or alterations occurring after the date of manufacture.
In no case shall the Company be liable for any consequential or incidental damages for
breach of this or any other Warranty, expressed or implied whatsoever, even if the loss
or damage is caused by the Company’s negligence or fault. Some states do not allow the
exclusion or limitation of incidental or consequential damages, so the above limitation
or exclusion may not apply to you. This Warranty gives you specific legal rights, and you
may also have other rights which vary from state to state.
Please refer to insert for the Limitations of Fire Alarm Systems
I56-3392-008R
PLASTIC LEVER
BREAK TAB AT
DOTTED LINE BY
TWISTING TOWARD
CENTER OF BASE.
USE SMALL-BLADED
SCREWDRIVER TO
PUSH PLASTIC LEVER
IN DIRECTION OF
ARROW.
SLOT
C0144-00
C1082-00
FIGURE 6A:
FIGURE 6B:
(+) SLC
(+) SLC
NO 1
NO 2
NC 2
COMM 2
COMM 1
NC 1
(–) SLC
(–) SLC
(–) POWER
(+) POWER
U.L. LISTED COMPATIBLE
CONTROL PANEL
OPTIONAL SOUNDER INTERCONNECT*
NOT
USED
SLC +
EXT –
EXT +
RA
SLC –
NOT
USED
SLC +
EXT –
EXT +
RA
SLC –
(+) SLC
(–) SLC
SUP (–)
SUP (+)
* GROUPING OF UP TO 6 MODEL B200SR SOUNDER BASES
INTELLIGENT
MONITOR MODULE
INTELLIGENT
RELAY MODULE†
FIRST
SOUNDER
BASE
LAST
SOUNDER
BASE
†THIS IS A STANDARD RELAY
MODULE CONFIGURED TO
REVERSE THE POWER
UL LISTED
EOL
RESISTOR
47k
UL LISTED 24V
POWER SUPPLY
END OF LINE RELAY
(EOLR-1 OR EQUIV
ALENT)
TO OPTIONAL REMOTE
ANNUNCIATOR
MODEL RA400Z/100Z
SS-450-001 2 I56-3392-008R
B200SR TERMINALS
No. Function
1. Not Used
2. Positive (+) Comm. Line In and Out
3. Negative (-) Comm. Line In and Out
4. External Supply Positive (+)
5. External Supply Negative (-)
6. Sounder Base Interconnect
MOUNTING
Mount the B200SR mounting plate directly to an electrical box. The plate will
mount directly to 4˝ square (with and without plaster ring), 4˝ octagon, 3 1
/2˝
octagon, single gang or double gang junction boxes.
1. Connect field wiring to terminals, as shown in Figure 1 and 2.
2. Attach the mounting plate to the junction box as shown in Figure 3.
3. To mount the sounder base, hook the tab on the sounder base to the groove
on the mounting plate.
4. Then, swing the sounder base into position to engage the pins on the
product with the terminals on the mounting plate.
5. Secure the sounder base by tightening the mounting screws.
6. Install a compatible smoke sensor as described in the installation manual
for the sensor.
TAMPER RESISTANT FEATURE
NOTE: Do not use the tamper-resist feature if the removal tool is to be used.
This detector base includes a tamper-resist feature that prevents its removal
from the base without the use of a tool. To activate this feature, break the tab
from the detector base as shown in Figure 6A. Then, install the detector. To
remove the detector from the base once the tamper-resist feature has been
activated, insert a small-bladed screwdriver into the slot from the top and
press down on the lever (see Figure 6B). This allows the detector to be rotated
counterclockwise for removal. The tamper-resist feature can be defeated by
breaking and removing the plastic lever from the base. However, this prevents
the feature from being used again.
TESTING AND MAINTENANCE
Sensors and bases must be tested after installation and as an integral part of a
periodic maintenance program. Test the B200SR as follows:
NOTE: Before testing, notify the proper authorities that the smoke sensor
system is undergoing maintenance and, therefore, will be temporarily out of
service. Disable the system undergoing maintenance to prevent unwanted
alarms.
1. If configured as in Figure 4 and 5, reverse the polarity of the external 24VDC
supply. If configured as in Figure 5, turn on the Intelligent Relay Module.
All B200SR bases on the loop should sound.
2. Latch the sensor LED on from the control panel. That individual sensor’s
B200SR should sound.
When performing maintenance on connected smoke sensors, carefully note
the location and address of each removed sensor.
FIGURE 4: WIRING DIAGRAM
FIGURE 5: WIRING DIAGRAM
FIGURE 3: MOUNTING
SS-450-001 3 I56-3392-008R
FIGURE 2:
Location of jumper–
remove to enable
continuous tone
(+) SLC
(–) SLC
(–) POWER
(+) POWER
U.L. LISTED COMPATIBLE
CONTROL PANEL
OPTIONAL SOUNDER INTERCONNECT*
TO OPTIONAL REMOTE
ANNUNCIATOR
MODEL RA400Z/100Z
CLASS A OPTIONAL WIRING
CLASS A OPTIONAL WIRING
NOT
USED
SLC +
EXT –
EXT +
RA
SLC –
NOT
USED
SLC +
EXT –
EXT +
RA
SLC –
(+) SLC
(–) SLC
SUP (–)
SUP (+)
* GROUPING OF UP TO 6 MODEL B200SR SOUNDER BASES
INTELLIGENT
MONITOR MODULE
FIRST
SOUNDER
BASE
SECOND
SOUNDER
BASE
LAST
SOUNDER
BASE
UL LISTED
EOL
RESISTOR
47k
NOT
USED
SLC +
EXT –
EXT +
RA
SLC –
UL LISTED 24V
POWER SUPPLY
END OF LINE RELAY
(EOLR-1 OR EQUIVALENT)
C0471-07
C0473-00
C0891-08
C0970-09
C0970-10
FIGURE 1:
1
2
34
5
6
DETECTOR ACTIVATES SOUNDER BASE(S) - (COMPLIES WITH UL268)
UL has approved grouping for up to six B200SR sounder bases. When wired as a group, any detector in the group that has been activated by the panel will cause
other B200SR units in the group to sound. This type of “local” grouping is accomplished by wiring the grouped devices together using terminal 6, Sounder Base
Interconnect, as shown in the diagram. This interconnect can also be used to attach B200SR devices to System Sensor B501-Series sounder bases. Some Fire
Alarm Control Panels (FACP) support the grouping of sounder bases via software in lieu of the Sounder Base Interconnect.
NOTE: A local grouping of horns via the sounder base interconnect is not supervised, therefore the groups can only be used as a supplementary evacuation
system. It is not acceptable to group horns via the sounder base interconnect for primary alarm signaling. Sounder bases which are grouped via software are not
subject to this limitation and may be used as part of the primary alarm signaling.
DETECTOR ACTIVATES SOUNDER BASE(S);
INTELLIGENT RELAY MODULE ACTIVATES ALL SOUNDER BASES - (COMPLIES WITH UL 268 AND UL 464)
UL has approved grouping for up to six B200SR sounder bases. When wired as a group, any detector in the group that has been activated by the panel will
cause other B200SR units in the group to sound. This type of “local” grouping is accomplished by wiring the grouped devices together using terminal 6, Sounder
Base Interconnect, as shown in the diagram. Some Fire Alarm Control Panels support the grouping of sounder bases via software in lieu of the Sounder Base
Interconnect.
NOTE: A local grouping of horns via the sounder base interconnect is not supervised, therefore the groups can only be used as a supplementary evacuation
system. It is not acceptable to group horns via the sounder base interconnect for primary alarm signaling. Sounder bases which are grouped via software
are not subject to this limitation and may be used as part of the primary alarm signaling.

Other System Sensor Security Sensor manuals

System Sensor B501A User manual

System Sensor

System Sensor B501A User manual

System Sensor 4451HTA User manual

System Sensor

System Sensor 4451HTA User manual

System Sensor WFDN Series User manual

System Sensor

System Sensor WFDN Series User manual

System Sensor DUCTSD240 User manual

System Sensor

System Sensor DUCTSD240 User manual

System Sensor L-Series User manual

System Sensor

System Sensor L-Series User manual

System Sensor L-Series User manual

System Sensor

System Sensor L-Series User manual

System Sensor B110LP User manual

System Sensor

System Sensor B110LP User manual

System Sensor 22051TLE-RF User manual

System Sensor

System Sensor 22051TLE-RF User manual

System Sensor B401BR User manual

System Sensor

System Sensor B401BR User manual

System Sensor B114LP User manual

System Sensor

System Sensor B114LP User manual

System Sensor 2112LP User manual

System Sensor

System Sensor 2112LP User manual

System Sensor WFDNA Series Technical specifications

System Sensor

System Sensor WFDNA Series Technical specifications

System Sensor B404B User manual

System Sensor

System Sensor B404B User manual

System Sensor WFDE Series User manual

System Sensor

System Sensor WFDE Series User manual

System Sensor B110LP User manual

System Sensor

System Sensor B110LP User manual

System Sensor B210LP User manual

System Sensor

System Sensor B210LP User manual

System Sensor 8100A FAAST User manual

System Sensor

System Sensor 8100A FAAST User manual

System Sensor WFD20 User manual

System Sensor

System Sensor WFD20 User manual

System Sensor 4451HT User manual

System Sensor

System Sensor 4451HT User manual

System Sensor 885-WP User manual

System Sensor

System Sensor 885-WP User manual

System Sensor B110RLP User manual

System Sensor

System Sensor B110RLP User manual

System Sensor SpectrAlert MP120K User manual

System Sensor

System Sensor SpectrAlert MP120K User manual

System Sensor CO1224T Instruction Manual

System Sensor

System Sensor CO1224T Instruction Manual

System Sensor B401R User manual

System Sensor

System Sensor B401R User manual

Popular Security Sensor manuals by other brands

Buckingham 60007 instructions

Buckingham

Buckingham 60007 instructions

PCB Piezotronics 1203-15A Installation and operating manual

PCB Piezotronics

PCB Piezotronics 1203-15A Installation and operating manual

Vega VEGAPULS C 21 operating instructions

Vega

Vega VEGAPULS C 21 operating instructions

Zircon StudSensor L70 OneStep user manual

Zircon

Zircon StudSensor L70 OneStep user manual

BRITBE G3 PRO instruction manual

BRITBE

BRITBE G3 PRO instruction manual

Transmitter Solutions iGAZER50LR instruction manual

Transmitter Solutions

Transmitter Solutions iGAZER50LR instruction manual

Dynalog C-SCAN 2000 Series Operator's manual

Dynalog

Dynalog C-SCAN 2000 Series Operator's manual

Dräger X-plore 5500 Instructions for use

Dräger

Dräger X-plore 5500 Instructions for use

Bosch DS1103i installation instructions

Bosch

Bosch DS1103i installation instructions

GE Motion Sensor user manual

GE

GE Motion Sensor user manual

X4-Life 701445 user manual

X4-Life

X4-Life 701445 user manual

Aqara TH-S02D user manual

Aqara

Aqara TH-S02D user manual

Weco CDZ Series user manual

Weco

Weco CDZ Series user manual

Olympus EPOCH 6LT user manual

Olympus

Olympus EPOCH 6LT user manual

Heiman HM-807DWP manual

Heiman

Heiman HM-807DWP manual

suprema BioEntry Series installation guide

suprema

suprema BioEntry Series installation guide

iProTech Protect 1207i user manual

iProTech

iProTech Protect 1207i user manual

EVE 20EBG8701 Get started

EVE

EVE 20EBG8701 Get started

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.