manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. System Sensor
  6. •
  7. Security Sensor
  8. •
  9. System Sensor B300A-6 User manual

System Sensor B300A-6 User manual

This manual suits for next models

1

Other System Sensor Security Sensor manuals

System Sensor B110LPA User manual

System Sensor

System Sensor B110LPA User manual

System Sensor 2300TB User manual

System Sensor

System Sensor 2300TB User manual

System Sensor B210LP User manual

System Sensor

System Sensor B210LP User manual

System Sensor WFDNA Series Technical specifications

System Sensor

System Sensor WFDNA Series Technical specifications

System Sensor B224RB User manual

System Sensor

System Sensor B224RB User manual

System Sensor SPECTRAlert H12/24K User manual

System Sensor

System Sensor SPECTRAlert H12/24K User manual

System Sensor 5451EIS User manual

System Sensor

System Sensor 5451EIS User manual

System Sensor B501AUS User manual

System Sensor

System Sensor B501AUS User manual

System Sensor OSI-RIE Series User manual

System Sensor

System Sensor OSI-RIE Series User manual

System Sensor L-Series User manual

System Sensor

System Sensor L-Series User manual

System Sensor WFDTNRN User manual

System Sensor

System Sensor WFDTNRN User manual

System Sensor L-Series User manual

System Sensor

System Sensor L-Series User manual

System Sensor DH400 User manual

System Sensor

System Sensor DH400 User manual

System Sensor WFDN Series User manual

System Sensor

System Sensor WFDN Series User manual

System Sensor B501-WHITE User manual

System Sensor

System Sensor B501-WHITE User manual

System Sensor SPECTRAlert CH24 Series User manual

System Sensor

System Sensor SPECTRAlert CH24 Series User manual

System Sensor B224RB User manual

System Sensor

System Sensor B224RB User manual

System Sensor B501A User manual

System Sensor

System Sensor B501A User manual

System Sensor SpectrAlert DS2475WAR User manual

System Sensor

System Sensor SpectrAlert DS2475WAR User manual

System Sensor Innovair SSK451 User manual

System Sensor

System Sensor Innovair SSK451 User manual

System Sensor B200SR User manual

System Sensor

System Sensor B200SR User manual

System Sensor DH400ACDC User manual

System Sensor

System Sensor DH400ACDC User manual

System Sensor B501AP User manual

System Sensor

System Sensor B501AP User manual

System Sensor Smoke Detector Spacing on Level Ceilings with Beams and... Quick reference guide

System Sensor

System Sensor Smoke Detector Spacing on Level Ceilings with Beams and... Quick reference guide

Popular Security Sensor manuals by other brands

Honeywell Home PROSiXCOCN Installation and setup guide

Honeywell Home

Honeywell Home PROSiXCOCN Installation and setup guide

Duevi SIRPZ-RB-868 Operation

Duevi

Duevi SIRPZ-RB-868 Operation

RKI 65-2483RK Operator's manual

RKI

RKI 65-2483RK Operator's manual

Nortech PD160 Enhanced Series user manual

Nortech

Nortech PD160 Enhanced Series user manual

Omron K8AC-H2 manual

Omron

Omron K8AC-H2 manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

Shinko SE2EA-1-0-0 instruction manual

Shinko

Shinko SE2EA-1-0-0 instruction manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

ACR Electronics COBHAM RCL-300A Product support manual

ACR Electronics

ACR Electronics COBHAM RCL-300A Product support manual

TOOLCRAFT 1712612 operating instructions

TOOLCRAFT

TOOLCRAFT 1712612 operating instructions

Elkron IM600 Installation, programming and functions manual

Elkron

Elkron IM600 Installation, programming and functions manual

Bosch WEU PDO 6 Original instructions

Bosch

Bosch WEU PDO 6 Original instructions

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

INSTALLATION AND MAINTENANCE INSTRUCTIONS
BEFORE INSTALLING
Please read the System Smoke Detectors Application Guide, which provides
detailed information on detector spacing, placement, zoning, wiring, and spe-
cial applications. Copies of this application guide are available from System
Sensor. CAN/ULC S524 guidelines should be observed.
NOTICE: This manual should be left with the owner/user of this equipment.
IMPORTANT: The detector used with this base must be tested and main-
tained regularly following CAN/ULC S536 requirements. The detector should
be cleaned at least once a year.
GENERAL DESCRIPTION
The B300A-6 and B300A-6-IV are plug-in detector bases intended for use in an
intelligent system, with screw terminals provided for power (+ and –), and
remote annunciator connections. Communication takes place over the power
lines (+ and –).
BASE TERMINALS
NO. FUNCTION
1 Power (–), Remote Annunciator (–)
2 Power (+)
3 Remote Annunciator (+)
FIGURE 1. TERMINAL LAYOUT
TERMINAL 1
TERMINAL 2
TERMINAL 3
C0127-07
MOUNTING
This detector base mounts directly to 4-inch square (with and without plaster
rings), 4-inch octagon, 31/2-inch octagon, and single gang junction boxes. To
mount, remove the decorative ring by turning it in either direction to unhook
the snaps, then separate the ring from the base. Install the base on the box
using the screws supplied with the junction box and the appropriate mounting
slots in the base.
Place the decorative trim ring on the base and rotate it in either direction until
it snaps into place. (See Figure 2.)
SPECIFICATIONS
Base Diameter: 6.1 inches (155 mm)
Base Height: 0.76 inches (19 mm)
Operating Temperature: Refer to applicable sensor Operating Temperature Range using the Base/Sensor Cross Reference Chart at systemsensor.com.
Electrical Ratings:
Operating Voltage: 15 to 32 VDC
Standby Current: 170 µA
Listings: ULC S529
I56-9127-001
FIGURE 2. MOUNTING DETECTOR TO BOX
SNAP ON
DECORATIVE
RING
SCREWS
(NOT SUPPLIED)
DETECTOR
BASE
BOX
(NOT SUPPLIED)
C2036-01
INSTALLATION AND WIRING GUIDELINES (SEE FIGURE 3)
All wiring must be installed in compliance with all applicable local codes
and any special requirements of the authority having jurisdiction. Proper wire
gauges should be used. The conductors used to connect smoke detectors to
control panels and accessory devices should be color-coded to reduce the like-
lihood of wiring errors. Improper connections can prevent a system from re-
sponding properly in the event of a fire.
For signal wiring (the wiring between interconnected detectors), it is recom-
mended that the wire be no smaller than 18 AWG (0.823 mm²). Wire sizes up
to 12 AWG (3.31 mm²) may be used with the base.
Make electrical connections by stripping about 3/8inch (10 mm) of insulation
from the end of the wire (use strip gauge molded in base). Then slide the wire
under the clamping plate and tighten the clamping plate screw. Do not loop
the wire under the clamping plate. (See Figure 4.)
Check the zone wiring of all bases in the system before installing the detec-
tors. This includes checking the wiring for continuity, correct polarity, ground
fault testing and performing a dielectric test.
The base includes an area for recording the zone, address, and type of detec-
tor being installed. This information is useful for setting the detector head
address and for verification of the detector type required for that location.
Once all detector bases have been wired and mounted, and the loop wiring
has been checked, the detector heads may be installed in the bases.
B300A-6 and B300A-6-IV
6" Plug-in Detector Bases
6581 Kitimat Road, Unit 6, Mississauga, Ontario L5N-3T5
800/736-7672, FAX: 905-812-0771
www.systemsensor.ca
1 I56-9127-001
11/17/2017
System Sensor warrants its enclosed smoke detector base to be free from defects in ma-
terials and workmanship under normal use and service for a period of three years from
date of manufacture. System Sensor makes no other express warranty for this smoke
detector base. No agent, representative, dealer, or employee of the Company has the au-
thority to increase or alter the obligations or limitations of this Warranty. The Company’s
obligation of this Warranty shall be limited to the repair or replacement of any part of the
smoke detector base which is found to be defective in materials or workmanship under
normal use and service during the three year period commencing with the date of manu-
facture. After phoning System Sensor’s toll free number 800-SENSOR2 (736-7672) for a
Return Authorization number, send defective units postage prepaid to: System Sensor,
Repair Department, RA #__________, 6581 Kitimat Road, Unit 6, Mississauga, Ontario
L5N-3T5. Please include a note describing the malfunction and suspected cause of fail-
ure. The Company shall not be obligated to repair or replace units which are found to be
defective because of damage, unreasonable use, modifications, or alterations occurring
after the date of manufacture. In no case shall the Company be liable for any consequen-
tial or incidental damages for breach of this or any other Warranty, expressed or implied
whatsoever, even if the loss or damage is caused by the Company’s negligence or fault.
Some states do not allow the exclusion or limitation of incidental or consequential dam-
ages, so the above limitation or exclusion may not apply to you. This Warranty gives you
specific legal rights, and you may also have other rights which vary from state to state
Please refer to insert for the Limitations of Fire Alarm Systems
THREE-YEAR LIMITED WARRANTY
System Sensor®is a registered trademark of Honeywell International, Inc.
FIGURE 5A. ACTIVATE TAMPER-RESIST FEATURE
PLASTIC LEVER
BREAK TAB AT DOTTED LINE BY
TWISTING TOWARD CENTER OF BASE
USE SMALL-BLADED SCREWDRIVER TO PUSH
PLASTIC LEVER IN DIRECTION OF ARROW
C0130-00
FIGURE 5B. DETECTOR REMOVAL
PLASTIC LEVER
BREAK TAB AT DOTTED LINE BY
TWISTING TOWARD CENTER OF BASE
USE SMALL-BLADED SCREWDRIVER TO PUSH
PLASTIC LEVER IN DIRECTION OF ARROW
C0130-00
FIGURE 6. CONNECTION TO REMOTE ANNUNCIATOR TERMINAL
STRIPPED WIRE
WIRE WITH SPADE LUG
C0116-00
TAMPER-RESIST FEATURE
NOTE: Do not use the tamper-resist feature if the removal tool will be used.
The detector base includes a tamper-resist feature that prevents removal of the
detector without using a small screwdriver or similar tool.
To activate this feature, use needle-nose pliers to break the tab on the detector
base as shown in Figure 5A. Then, install the detector.
To remove the detector from the base once the tamper-resist feature has been
activated, remove the decorative ring by rotating it in either direction and
pulling it away from the base. Then, insert a small screwdriver into the notch,
as indicated in Figure 5B, and press the plastic lever toward the mounting
surface before rotating the detector counterclockwise for removal.
The tamper-resist feature can be defeated by breaking and removing the plas-
tic lever from the base. However, this prevents the feature from being used
again.
REMOTE ANNUNCIATOR (RA100ZA)
Connect the remote annunciator between terminals 1 and 3 using the spade
lug terminal included. The spade lug terminal is connected to the base termi-
nal as shown in Figure 6.
It is not acceptable to have three stripped wires under the same wiring ter-
minal unless they are separated by a washer or equivalent means. The spade
lug supplied with the model RA100ZA is considered an equivalent means. See
Figure 3 for proper installation.
FIGURE 3. TYPICAL WIRING DIAGRAM FOR 2-WIRE LOOP
2
31
2
33
1
2
1
(–)
(+)
+-
ULC LISTED COMPATIBLE
CONTROL PA NEL
CAUTION: DO NOT LOOP WIRE
UNDER TERMINAL 1 OR 2.
BREAK WIRE RUN TO PROVIDE
SUPERVISION OF CONNECTIONS.
CLASS A OPTIONAL WIRING
REMOTE
ANNUNCIATOR
(–)
(+)
C0129-02CDN
FIGURE 4. TERMINAL WIRE INSTALLATION
C0473-00
2 I56-9127-001
©2017 System Sensor. 11/17/2017