Contents
1. BEFORE USING------------------------------------------------------------------------------------------------------------- 5
2. COMPONENTS -------------------------------------------------------------------------------------------------------------- 6
3. PRODUCT -------------------------------------------------------------------------------------------------------------------- 7
4. HOW TO USE ---------------------------------------------------------------------------------------------------------------- 9
5. GET STARTED -------------------------------------------------------------------------------------------------------------11
6. HOW TO CONNECT ------------------------------------------------------------------------------------------------------11
7. SETTINGS ------------------------------------------------------------------------------------------------------------------ 13
8. SETTINGS USING UTILITY -------------------------------------------------------------------------------------------- 19
----------------------------------------------------------------Appendix--------------------------------------------------------------
1. DIMENSION ---------------------------------------------------------------------------------------------------------- 20
2. SERIAL PORT PIN ------------------------------------------------------------------------------------------------- 21
3. RJ-45 PORT(W/POE PD FUNCTION) ------------------------------------------------------------------------- 22
5. RESET SWITCH (TACT) ------------------------------------------------------------------------------------------ 23
6. SPECIFICATION ---------------------------------------------------------------------------------------------------- 24
7. TROUBLE SHOOTING -------------------------------------------------------------------------------------------- 26
8. CERTIFICATION ---------------------------------------------------------------------------------------------------- 27

sLAN/all-PoE User Manual
4
Please be sure to read this manual before using and use the product safely and accurately.
• Pictures and photos in the manual may be different from the physical, and the document is subject to change
without notice to improve performance. For the last information, please visit our website (www.sysbas.com).
• To view frequently asked questions and answers, please visit our website and find Support –Technical Support –
FAQ section.
• Documents can be downloaded from the product page or Download section.
• Sellers or users should be aware of the fact that this device is intended for industrial use(Class A), not for
residential use.
• This device has a potential for radio interference during use and may receive harmful interference from other
devices.
• Warranty policy is included in the product packaging.
• This product is domestic (Korea) and cannot be used overseas with different power/frequency.

sLAN/all-PoE User Manual
5
1. Before Using
sLAN/all PoE is a small Ethernet converter which provides Ethernet wired communication and Power over Ethernet
(PoE) for serial equipment supporting RS232/422/485. The communication standard supports IEEE 802.3 10/100
Base-TX, IEEE 802.3af. It is equipped with serial standard DB9 connector, providing easy-to-apply gateway function
to RS232/422/485 compliant equipment. Maximum communication speed is 921.6Kbps for serial and 100Mbps for
Ethernet.
sLAN/all-PoE is a device that connects various serial equipment to the network and remote controls, monitors over
the network.
● Communication Speed up to 921.6Kbps
● RS/232/422/485 Serial 1 port
● 10/100Mbps Ethernet: 1port
● IEEE 802.3af PoE(Power over Ethernet)
● Industrial Grade Operating Temperature: -40 to 85℃(-40 to 185℉)
● Provides COM Port Redirector
● Provides Web Browser, SGConfig for Management
● ±15KV IEC ESD Protection

sLAN/all-PoE User Manual
6
2. Components
Components
Ordering Information
sLAN/all-PoE, LAN Cable, Ejector Pin,
Product Warranty & Download Guide
sLAN/all-PoE (Micro-USB B type)

sLAN/all-PoE User Manual
7
3. Product
LED
LED State Operation
1
RDY(Yellow) Blink Turns ON briefly and then OFF when Power ON.
Flashes when Booting is complete.
2
TXD (Green) Blink Flashes when serial data is transmitted.
3
RXD (Red) Blink Flashes when serial data is received.

sLAN/all-PoE User Manual
8
Connector
Front Back (Micro USB Type )
Front:
• Serial Port(DB9 Male): RS232/RS422/RS485 (Please refer to the APPENDIX for pin specifications)
Back:
• PWR: Micro USB Type B
• LAN Port: This port(RJ45) is used to connect sLAN/all PoE to Ethernet card, hub, router and other wired network-
connected equipment.
• RST: By pressing and releasing the button, sLAN/all PoE restarts.

sLAN/all-PoE User Manual
9
4. How to Use
Please refer to “Chapter 6. Get Started” for instructions on how to set up.
① PC – Serial Equipment Connection
For the most common example, the PC and sLAN/all PoE are connected to the network, allowing the PC to use serial
devices connected to the sLAN/all-PoE.
② Serial Communication Tunneling
By extending the serial cable between the PC and the serial equipment via the network, it can be used like a serial
cable with no distance limit. To use this feature, set it to TCP Server – TCP Client mode or UDP Server – UDP
Client mode(please refer to Chapter 7. Settings). For these two modes, only data can be sent and received.

sLAN/all-PoE User Manual
10
③ COM Port Redirection
By using Redirection, users can use the serial port of sLAN/all PoE connected to the network as if it were a PC-
mounted serial port.
Factory / Industrial Automation
PLC, Robot Arm, Human-Machine Interface, Logistics Warehouse Rail
Medical devices, Examination Equipment Controllers
Alarm Device
Home Appliances / Electronics
Power Management Devices, Game Consoles
Instruments, Gas Detectors, Water Quality and Pollution Measuring Instruments
Data Collection and Distribution Equipment
Finance / Building Automation
Card Reader, Barcode Scanner, Kiosk, POS related equipment
Serial Printers, ATMs, Credit Card Reader
Biometrics, Security Equipment

sLAN/all-PoE User Manual
11
5. Get Started
An Ethernet port is required to connect sLAN/all PoE to the network. Ethernet supports 10Mbps and 100Mbps Ethernet
connections. The LAN port on sLAN/all PoE supports MDIX feature, which automatically recognizes Cross Ethernet Cable
and Direct Ethernet Cable, so it does not matter which cable users connect. Connect one end of the cable to the sLAN/all
PoE and the other to the network equipment.
6. How to Connect
The following methods are used to connect sLAN/all-PoE to devices and networks:
Power On for the First Time
First, check if the input voltage supplied to sLAN/all PoE matches the specification of the model and supply the correct voltage.
sLAN/all POE turns on and starts booting only when the power is normally supplied.
There are RDY, TXD/RXD LED for checking operation status.
(Please refer to Chapter 3. Product for LED status)
To access the web of sLAN/all PoE, an IP address is required. A static IP is assigned to the sLAN/all PoE as default. You can
manually enter other IP address after the initial access, or set up sLAN/all PoE to automatically assign an IP address from
DHCP server. This depends on your network environment or policy, but it is strongly recommended to assign your own static
IP to sLAN/all PoE.
Access
To view or set up the environment of sLAN/all PoE, you should access to Web browser or use setup utility. This manual is
based on how to set it up through the Web browser.
(Please refer to the SGConfig manual for instructions on how to use the setup utility)
You should first know the IP address, the network address where sLAN/all PoE is operating.
In case the LAN port of sLAN/all PoE is in use with an IP assigned by DHCP server, or it is set to a static IP address, or if you
do not know the IP address, sLAN/all PoE provides the following methods:
Default IP Address: 192.168.0.223
The default IP address of sLAN/all PoE is set to 192.168.0.223. To connect to this address, you should change your network
settings so that your PC can access 192.168.0.223. Please refer to the following example for settings:

sLAN/all-PoE User Manual
12

sLAN/all-PoE User Manual
13
7. Settings
Precaution for Web Access
Web setting is not supported in the network environment below 10Mbps as shown below:
Therefore, if you use the Web to change the settings, you must be in 100Mbps network environment or connect the integrated
device to a PC as shown below. If it is difficult to set the environment, please use the SGConfig utility to set up the device.
Please refer to the ‘Access’ part of the previous page when directly connecting and setting with the PC.
Connection
When you open a Web browser and enter the IP address of sLAN/all PoE, an authentication window appears on first time
connection. With the default ID “slan” and the password “99999999”, the Web setting page appears.

sLAN/all-PoE User Manual
14
Network Setting
Network Setting page will be displayed in the initial screen of the Web setting, which shows the Network information of the
equipment as below:
You can set network environments and network management in the Networking Setting page. Once you have changed the
settings, you must press the [Submit] button to save the changed value and restart it through the [Reboot] menu to apply
them to actual equipment operation. If you exist without saving the changes, the changed value will be lost.
If you have not saved the modified value by the [Submit] button, you can return to the value before changing with the [Cancel]
button.
The main features of Networking Setting page are as follows:
Menu Default Description
Device Name sLAN/all Set the name of the device
MAC Address Own Address Show MAC Address
Connection Type Static Select whether to use Static IP to use fixed IP or Dynamic IP to use
assigned IP using DHCP
IP Address 192.168.0.223
Set the current IP address
(If the Connection Type is Static IP, enter the IP address directly. If
DHCP, the current IP is displayed and cannot be changed.)
Subnet Mask 255.255.255.0
Set the current Subnet Mask address
(If the Connection Type is Static IP, enter the subnet mask address
directly. If DHCP, the current subnet mask address is displayed and
cannot be changed.)
Gateway 192.168.0.254
Set the current Gateway address
(If the Connection Type is Static IP, enter the gateway address
directly. If DHCP, the current gateway is displayed and cannot be
changed.)
DNS 168.126.63.1 Set the IP address of the DNS(Domain Name Service)

sLAN/all-PoE User Manual
15
Operation Setting
You can set the operating mode and network socket options in the Operation Settings page. Once you have changed the
settings, you must press the [Submit] button to save the changed value and restart it through the [Reboot] menu to apply
them to actual equipment operation. If you exist without saving the changes, the changed value will be lost.
If you have not saved the modified value by the [Submit] button, you can return to the value before changing with the [Cancel]
button.
The main features of Setup Menu are as follows:
Menu Default Description
Operation
Mode
COM
Redirector
Set the operation protocol to use on the serial port
COM Redirector
Enables the serial port of sLAN/all PoE to be used as a virtual COM port on a PC
in Windows 7 or above OS environment. When this mode is selected, all settings
in the serial follow the virtual COM Port settings.
TCP Server
sLAN/all PoE acts as a socket server and waits for connection from Client on the
network. The socket number waiting for a connection is set at [Local Port]. When
the socket connection is complete, sends the data that occurs between the socket
and the serial port.
TCP Client
When a particular server on the network waits for a connection, sLAN/all PoE
acts as a socket Client and attempts to connect to the IP address and socket
number of the set server. When socket connection is complete, sends the data
that occurs between the socket and the serial port. Set the IP and port number of
the server which you want to request access at [Target IP/Port].
UDP Server
sLAN/all PoE acts as a UDP server and waits for UDP connection from Client on
the network. Set the socket number that waits for a connection at [Local Port].

sLAN/all-PoE User Manual
16
Menu Default Description
When UDP packets are received to the socket number waiting for a connection,
data is sent to the serial port, and data entered into the serial port is made into
UDP packets and sent to the Client.
UDP Client
When data is entered into the serial port, sends UDP packets to the IP and socket
number of the set server. Set the IP and port number of the server to which you
want to request access at [Target IP/Port].
Local Port 4001 Specify the socket number assigned to the port. Use this port to wait for network
socket connection in TCP Server and UDP Server mode.
Target IP 0.0.0.0 Specify the IP address of the destination to connect to in TCP Client and UDP
Client mode.
Target Port 4001 Specify the port of the destination to connect to in TCP Client and UDP Client
mode.
Latency
Time
0
Set if you want to send continuous incoming data from the serial port to the
socket at once.
For example, if a serial device sends 100 bytes of text and the socket is sent to
the server via sLAN/all PoE, with this value set to 0, data entered in bytes at a
time is immediately passed to the server via the socket. This guarantees real-time
performance but causes a lot of traffic to the network, sending lots of packets to
the server.
If this value is set to a non-zero value, the data received several bytes at a time is
buffered, waited for a set amount of time, and read again. If any data is received,
it is re-buffered, otherwise it is considered all received and sent in batches to the
socket. There are no traffic problems caused by many packets, but real-time
performance is not guaranteed.
TCP Alive
Check Time 60
After the socket connection is complete, check the network status at the set time
interval to terminate or reset the socket connection if a network abnormality is
determined.
(If set to 0, this feature is not used. Value can be set from 0 to 65535 sec)
If the initial value is set to 0, this feature is not performed and keep the socket
connection.
TCP No-
delay Disable
When TCP communication, it decides whether to collect the data sent and
received over Ethernet fist and process it together or process it immediately.
When set to Disable, TCP send/receive data will be collected and processed,
which results in a delay between Ethernet and serial transmission. But it is
beneficial for high speed data transmission and packet-unit data transmission.
When set to Enable, TCP send/receive data will be processed immediately. This
minimizes the delay between Ethernet and serial transmissions, but
disadvantages high speed communication and packet-unit data transmission.

sLAN/all-PoE User Manual
17
Serial Setting
You can set the operating environment for serial ports in the Serial Settings page. Once you have changed the settings, you
must press the [Submit] button to save the changed value and restart it through the [Reboot] menu to apply them to actual
equipment operation. If you exist without saving the changes, the changed value will be lost.
If you have not saved the modified value by the [Submit] button, you can return to the value before changing with the [Cancel]
button.
If Operation Mode is COM Redirector in the Operation Settings, the current serial settings are ignored and changed to the
settings when the virtual COM Port is connected.
The main features of the Setup Menu are as follows:
Menu Default Description
Interface RS-232 Set the interface of the serial port(Option: RS-422/485)
Termination
Register Disable Set the termination resister when the serial is RS-422 or RS-485.
RS-422 Multi-
Drop Mode Master
Set the operation mode when serial communication is made in RS-422
interface. Set Master to Master, Slave to Slave in RS-422 Multi-Drop
configuration. For 1:1 connection other than RS-422 Multi-Drop mode, set both
connecting equipment to Master.
Baud Rate 9600 bps
Set the communication speed of the serial port
(Option: 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200,
230400, 460800, 921600bps)
Data Bits 8 Set the number of bits which make up the byte
(Option: 5, 6,7,8)

sLAN/all-PoE User Manual
18
Menu Default Description
Stop Bits 1 Set the number of stop bit
(Option: 1, 2)
Parity No Set the parity check method
(Option: No, Odd, Even)
Flow Control None
Set the flow control method
When the RTS/CTS option is selected, the RTS signal line is automatically
controlled according to the incoming serial data flow, and the serial data
transmission is automatically controlled according to the CTS signal line status.
This function only works in RS-232 interface.
(Option: None, RTS/CTS).
Change ID/PW
An ID and password is required to access the Web settings page, which you can change on the screen below. Please note
that the setting is applied simultaneously with saving without rebooting.
Reboot
The device will be restarted.
If you changed the settings and saved the setting values through [Submit] button, the changes will be reflected and the
sLAN/all PoE will restarts.

sLAN/all-PoE User Manual
19
8. Settings Using Utility
Search
When you run SGConfig and click Search, it will discover the sLAN/all PoE connected to the network.
When you select the list of devices discovered in the list that you want to set up and click Configure, a window
appears to set up sLAN/all-PoE as shown below.
Setting
Select the device you want to set up among the discovered devices and click [Configure]. Then a window for sLAN/all
PoE setting will appears as shown below:
(Please refer to SGConfig Manual for detailed options and setup methods)

sLAN/all-PoE User Manual
20
------------------------------- APPENDIX ----------------------------
1. Dimension
Table of contents
Other SystemBase Media Converter manuals

SystemBase
SystemBase CS-LAN User manual

SystemBase
SystemBase Multi-4U Ver1.7 User manual

SystemBase
SystemBase SerialGate 2000 Series User manual

SystemBase
SystemBase TALUS User manual

SystemBase
SystemBase SWIFIALLV10 User manual

SystemBase
SystemBase BT-232 User manual

SystemBase
SystemBase SerieslGate SG-1010/232 User manual

SystemBase
SystemBase WCS-232 v4.0 User manual