Taco ZVC404-EXP-4 User manual

1234
ZONE 1
1234
ZONE 2
1234
ZONE 3
1234
ZONE 4
PRIORITY
ZONE
2 WIRE
ZONE VALVE
(NO END SWITCH)
MUST USE JUMPER
TACO
3 WIRE
ZONE VALVE
1
2
3
JUMPER
3 & 4
MOTOR END
SWITCH
4 WIRE
ZONE VALVE
(POWER OPEN,
SELF CLOSING)
JUMPER
3 & 4
POWER
CONTROLS
SEE NOTE
ZVC 404-EXP-4
FOUR ZONE EXPANDABLE
ZONE VALVE CONTROL
24 VAC
FACTORY
INSTALLED
TRANSFORMER
120 VAC
INPUT
WHITE
BLACK
POWER IN
24 VAC
24 VAC
FACTORY
INSTALLED
TRANSFORMER
120 VAC
INPUT
WHITE
BLACK
TO
CIRCULATOR
DRY
CONTACTS
N/O COM N/C
PUMP END
SWITCH
ZONE 4 PUMP
END SWITCH
SLAVE
PRIORITY ON
RESET
POST PURGE ON
PRIORITY PROTECTION ON
PUMP EXERCISE ON
30 SEC/2 WK
MASTER
OFF
NORMAL
OFF
OFF
OFF
4 MIN/24 HOUR
NOTE: When a circulator is used
on the priority zone instead of a
zone valve, jumper 3 and 4 of
the priority zone.
THERMOSTATS (24 VAC)
INDIRECT
WATER HEATER
AQUASTAT OR
THERMOSTAT
T STAT 1 VALVE 1
T STAT 2 VALVE 2
T STAT 3 VALVE 3
T STAT 4 VALVE 4
POWER
LED
INDICATORS
TO: "TT" ON BOILER
TO: "TT" ON BOILER WITH
DHW "TT" INPUT
ZONE 1
ZONE 2 ZONE 3 ZONE 4 NET
EXPANSION
MAIN
PRIORITY
XX XX ABCRW
CRW
CRW
CRW
C12
END SWITCH THERMOSTATS (24 VAC) PRIORITY
24 VAC ZONE VALVES
ACCESSORY
PORT
PRIORITY
XX
FUSE
5 AMP
FUSE
5 AMP
Powered from Transformer APowered from Transformer B
A
B
Powered from Transformer APowered from Transformer B
Operation/External Diagnostics: When any thermostat calls for heat,
the appropriate zone valve is energized and the yellow light goes on.
When the zone valve is fully open, the red light goes on and energizes
the end switch relay. The green light should always be on, indicating
that power is connected.
Priority Operation: When the priority dip switch is set to ON and the
priority zone is actuated, all other zones will stop operation until pri-
ority zone is satisfied. When not switched to priority, all zones will
operate independently.
Mode Operation: When the dip switch is set to NORMAL, the end
switch relay will be energized if any zone is in operation. When the switch
is set to RESET, the end switch relay will only be energized if the priority
zone is in operation, or through the operation of a plug-in reset control.
Post Purge Operation: When the dip switch is set to ON, the priori-
ty zone output will stay energized for 2 minutes after its thermostat or
aquastat is satisfied, but not operate the boiler.
Priority Protection Operation: When the dip switch is set to ON, and
if the priority zone calls continuously for more than one hour, power
is returned to all the other zones, allowing each zone to function inde-
pendently. Once the priority zone is satisfied, the control's auto-reset is
activated and the priority zone is again allowed to have priority for up
to one hour starting from when it calls next.
Pump Exercise Operation: When the dip switch is set to ON, the solid
state timer cycles all the zone valves and circulating pumps that are
attached to the Expandable Zone Valve Control at the selected time
interval. The time interval can be set for the valves and pumps to run
for either 30 seconds every 2 weeks or for 4 minutes every 24 hours.
End Switches (Dry Contacts): The main end switch closes when any
zone thermostat calls for heat and the mode switch is set to NORMAL.
The main end switch also closes when the mode switch is set to RESET
and a PC Series boiler reset power control is calling for heat. The priori-
ty end switch closes only when the priority zone thermostat or aquastat
is calling for heat.
Expansion Connections: Set the expansion switch to MASTER on the
switching relay that has the designated priority zone or is utilizing the
PC Series plug-in option. Set all other daisy chained controls to SLAVE.
Using thermostat wire (18-22 gauge) connect between terminals A, B,
C on the master control to the corresponding A, B, C on the SLAVE con-
trol(s). Controls may be daisy chained up to 20 zoning panels using any
combination of -EXP controls (120 zones if all are 6 zone panels).
Thermostat Input (24 vac):
RHot side of transformer. Connect to Ron thermostat.
WSwitched R signal from thermostat. Connect to W on
thermostat.
CCommon side of transformer. Connect to COM on
thermostat (optional).
NET Network terminals 1 & 2 are tied together for wiring convenience
when using communicating style thermostats (optional).
Power Input (120 vac):
Connect neutral (white) leads on transformers to 120 volts ac
neutral power supply.
Connect hot (black) leads on transformers to 120 volts ac
hot power supply.
Pump End Switch (Dry Contacts):
Connect hot power supply to the right side of the pump end switch
terminal on board.
Connect hot input lead of the circulator to the left side of the pump
end switch terminal on board.
Zone 4 Pump End Switches (Dry Contacts): See Diagram.
N/O Normally open terminal of the priority zone relay.
COM Common terminal of the priority zone relay.
N/C Normally closed terminal of the priority zone relay.
End Switch Pump Neutral Connections:
Connect neutral power supply directly to neutral lead on circulator(s).
WARNING: Wiring connections must be made in accordance with all
applicable electrical codes. Use copper wire only. 120 VAC wiring must have
a minimum temperature rating of 75°C. Failure to follow this instruction
can result in personal injury or death and/or property damage. 12-18 gauge
wire recommended for 120 VAC connections, 14-22 gauge wire for thermo-
stat connections, and 14-22 gauge wire for 24 VAC source connections.
Wiring Diagram
Instruction Sheet
ZVC404-EXP-4 Zone Valve Control
102-399
SUPERSEDES: New EFFECTIVE: May 1, 2010
Plant ID# 9300-2880
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that
may cause undesired operation.
N/O
COM
N/C
PUMP END
SWITCH
ZONE 4 PUMP
END SWITCH
XX
DHW
PUMP
SYSTEM PUMP AND BOILER TURN ON WHEN ANY ZONE VALVE OPENS.
DHW PUMP TURNS ON ONLY WHEN PRIORITY ZONE CALLS.
SECONDARY PUMP COMES ON WHEN ANY ZONE CALLS EXCEPT PRIORITY ZONE.
SYSTEM
PUMP SECONDARY
PUMP
120
VAC
HOT
NEUTRAL
Optional System
and/or DHW and/or
Secondary Circulators
Specifications:
PRODUCT NUMBER INPUT MAX 24 VAC TYPE 1 ENCLOSURE
NUMBER OF ZONES VOLTAGE OUTPUT @ 25°C WIDTH HEIGHT DEPTH
ZVC404-EXP-4 4 with Priority 120/60/1 VAC, 3A 24 VA per Zone 121⁄4"8" 3"
40 VA per Transformer
The pump end switches are rated 1⁄6hp, 5 amps at 120 VAC. The main and priority end switch connections
are rated 24 VAC, 1 amp. All thermostat and zone valve connections supply a 24 VAC class 2 output.

24 VAC
FACTORY
INSTALLED
TRANSFORMER
120 VAC
INPUT
WHITE
BLACK
H
N
BOILER
24 VAC
FACTORY
INSTALLED
TRANSFORMER
120 VAC
INPUT
WHITE
BLACK
24 VAC
FACTORY
INSTALLED
TRANSFORMER
120 VAC
INPUT
WHITE
BLACK
24 VAC
FACTORY
INSTALLED
TRANSFORMER
120 VAC
INPUT
WHITE
BLACK
Note: When a circulator is used on the
priority zone instead of a zone valve,
jumper 3 and 4 of the priority zone.
SWITCH SETTINGS
Master/Slave: Master
Reset/Normal: Normal
Priority Zone: On
SWITCH SETTINGS
Master/Slave: Slave
Reset/Normal: Normal
Priority Zone: Off
120 VAC
INPUT
MASTER
SLAVE
SYSTEM PUMP AND BOILER TURN ON
WHEN ANY ZONE VALVE OPENS.
SYSTEM
PUMP
DRY
CONTACTS
DRY
CONTACTS
TO: "TT" ON BOILER
TO: "TT" ON BOILER WITH
DHW "TT" INPUT
1234
ZONE 1
1234
ZONE 2
1234
ZONE 3
1234
ZONE 4
1234
ZONE 5
1234
ZONE 6
PRIORITY
ZONE
2 WIRE ZONE VALVE
(NO END SWITCH)
MUST USE JUMPER
TACO
3 WIRE
ZONE VALVE
1
2
3
JUMPER
3 & 4
MOTOR END
SWITCH
4 WIRE ZONE VALVE
(POWER OPEN,
SELF CLOSING)
JUMPER
3 & 4
SEE NOTE
ZVC 406-EXP-4
SIX ZONE EXPANDABLE
ZONE VALVE CONTROL
POWER IN
24 VAC
N/O COM N/C
ZONE 6 PUMP
END SWITCH
SLAVE
PRIORITY ON
RESET
POST PURGE ON
PRIORITY PROTECTION ON
PUMP EXERCISE ON
30 SEC/2 WK
MASTER
OFF
NORMAL
OFF
OFF
OFF
4 MIN/24 HOUR
THERMOSTATS
24 VAC
T STAT 1 VALVE 1
T STAT 2 VALVE 2
T STAT 3 VALVE 3
T STAT 4 VALVE 4
VALVE 5
T STAT 6 VALVE 6
POWER
LED
INDICATORS
T STAT 5
ZONE 1 ZONE 2
ZONE 3
ZONE 4 ZONE 5 ZONE 6 NET
EXPANSION
MAIN
PRIORITY
XX XX ABCRW
CRW
CRW
CRW
CRW
CRW
C12
END SWITCH THERMOSTATS (24 VAC) PRIORITY
24 VAC ZONE VALVES
1234
ZONE 1
1234
ZONE 2
1234
ZONE 3
1234
ZONE 4
1234
ZONE 5
1234
ZONE 6
PRIORITY
ZONE
2 WIRE ZONE VALVE
(NO END SWITCH)
MUST USE JUMPER
TACO
3 WIRE
ZONE VALVE
1
2
3
JUMPER
3 & 4
MOTOR END
SWITCH
4 WIRE ZONE VALVE
(POWER OPEN,
SELF CLOSING)
JUMPER
3 & 4
SEE NOTE
ZVC 406-EXP-4
SIX ZONE EXPANDABLE
ZONE VALVE CONTROL
POWER IN
24 VAC
N/O COM N/C
PUMP END
SWITCH
ZONE 6 PUMP
END SWITCH
SLAVE
PRIORITY ON
RESET
POST PURGE ON
PRIORITY PROTECTION ON
PUMP EXERCISE ON
30 SEC/2 WK
MASTER
OFF
NORMAL
OFF
OFF
OFF
4 MIN/24 HOUR
THERMOSTATS
24 VAC
INDIRECT
WATER HEATER
AQUASTAT OR
THERMOSTAT
T STAT 1 VALVE 1
T STAT 2 VALVE 2
T STAT 3 VALVE 3
T STAT 4 VALVE 4
VALVE 5
T STAT 6 VALVE 6
POWER
LED
INDICATORS
T STAT 5
ZONE 1 ZONE 2
ZONE 3
ZONE 4 ZONE 5 ZONE 6 NET
EXPANSION
MAIN
PRIORITY
XX XX ABCRW
CRW
CRW
CRW
CRW
CRW
C12
END SWITCH THERMOSTATS (24 VAC) PRIORITY
24 VAC ZONE VALVES
PRIORITY
PRIORITY
XX
PUMP END
SWITCH
XX
POWER
CONTROLS
ACCESSORY
PORT
FUSE
5 AMP
FUSE
5 AMP
POWER
CONTROLS
ACCESSORY
PORT
FUSE
5 AMP
FUSE
5 AMP
SLAVE
PRIORITY ON
RESET
POST PURGE ON
PRIORITY PROTECTION ON
PUMP EXERCISE ON
30 SEC/2 WK
MASTER
OFF
NORMAL
OFF
OFF
OFF
4 MIN/24 HOUR
Operation/External Diagnostics:
When any thermostat calls for heat, the
appropriate zone valve is energized and the
yellow light goes on. When the zone valve
is fully open, the red light goes on and
energizes the end switch relay. The green
light should always be on, indicating that
power is connected.
CONTROLS MADE EASY.®
TACO, INC., 1160 Cranston Street, Cranston, RI 02920 Telephone: (401) 942-8000 FAX: (401) 942-2360.
TACO (Canada), Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8. Telephone: 905/564-9422. FAX: 905/564-9436.
Visit our web site at: http://www.taco-hvac.com
Printed in USA
Copyright 2010
TACO, Inc.
Taco, Inc. will repair or replace without charge
(at the company’s option) any product or part
which is proven defective under normal use
within three (3) years from the date of start-up or
three (3) years and six (6) months from date of
shipment (whichever occurs first).
In order to obtain service under this warranty, it
is the responsibility of the purchaser to promptly
notify the local Taco stocking distributor or Taco
in writing and promptly deliver the subject prod-
uct or part, delivery prepaid, to the stocking dis-
tributor. For assistance on warranty returns, the
purchaser may either contact the local Taco
stocking distributor or Taco. If the subject prod-
uct or part contains no defect as covered in this
warranty, the purchaser will be billed for parts
and labor charges in effect at time of factory
examination and repair.
Any Taco product or part not installed or operat-
ed in conformity with Taco instructions or which
has been subject to misuse, misapplication, the
addition of petroleum-based fluids or certain
chemical additives to the systems, or other
abuse, will not be covered by this warranty.
If in doubt as to whether a particular substance
is suitable for use with a Taco product or part, or
for any application restrictions, consult the
applicable Taco instruction sheets or contact
Taco at [401-942-8000].
Taco reserves the right to provide replacement
products and parts which are substantially sim-
ilar in design and functionally equivalent to the
defective product or part. Taco reserves the
right to make changes in details of design, con-
struction, or arrangement of materials of its
products without notification.
TACO OFFERS THIS WARRANTY IN LIEU OF
ALL OTHER EXPRESS WARRANTIES. ANY
WARRANTY IMPLIED BY LAW INCLUDING
WARRANTIES OF MERCHANTABILITY OR FIT-
NESS IS IN EFFECT ONLY FOR THE DURATION
OF THE EXPRESS WARRANTY SET FORTH IN
THE FIRST PARAGRAPH ABOVE.
THE ABOVE WARRANTIES ARE IN LIEU OF
ALL OTHER WARRANTIES, EXPRESS OR
STATUTORY, OR ANY OTHER WARRANTY
OBLIGATION ON THE PART OF TACO.
TACO WILL NOT BE LIABLE FOR ANY SPE-
CIAL, INCIDENTAL, INDIRECT OR CONSE-
QUENTIAL DAMAGES RESULTING FROM THE
USE OF ITS PRODUCTS OR ANY INCIDENTAL
COSTS OF REMOVING OR REPLACING
DEFECTIVE PRODUCTS.
This warranty gives the purchaser specific
rights, and the purchaser may have other rights
which vary from state to state. Some states do
not allow limitations on how long an implied
warranty lasts or on the exclusion of incidental
or consequential damages, so these limitations
or exclusions may not apply to you.
LIMITED WARRANTY STATEMENT
Features:
External Indicator Lights
Plug-In PowerPort Cards
Switchable Priority
Simplified Wiring
Add-On Power Controls
Works with 2, 3, or 4-Wire Zone Valves
Compact Design
Fuse Protected
100% Factory Tested
Isolated End Switch
Expandable to 20 Zones
Extra Set of Dry Contacts
Contractor Friendly PC Board Layout
Universal Thermostat Compatibility
Sturdy Screw Connections
Extended 3 Year Warranty
Made in the USA
2 EXP Zone Valve Controls Connected Together
with System Pump
Dip Switch Settings
Table of contents
Other Taco Control Unit manuals

Taco
Taco Comfort Solutions 5000-3 Series User manual

Taco
Taco 102-111 User manual

Taco
Taco Zone Sentry Series User manual

Taco
Taco i Series User manual

Taco
Taco Zone Sentry User manual

Taco
Taco 5000-2 User manual

Taco
Taco HR Series Specifications

Taco
Taco SR501 User manual

Taco
Taco 5000-HX Series User manual

Taco
Taco 5123-WH-N User manual
Popular Control Unit manuals by other brands

Helvex
Helvex V. D. 1176 installation guide

Marathon
Marathon DVR 2000E Installation, operation and maintenance manual

StepperOnline
StepperOnline CL57T user manual

BRÖTJE
BRÖTJE VGU 86 S installation instructions

FARFISA INTERCOMS
FARFISA INTERCOMS PL10PED manual

STIEBEL ELTRON
STIEBEL ELTRON HM Trend Operation and installation