manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Taylor
  6. •
  7. Thermometer
  8. •
  9. Taylor 5296652 User manual

Taylor 5296652 User manual

Other Taylor Thermometer manuals

Taylor 5925N User manual

Taylor

Taylor 5925N User manual

Taylor 5341N User manual

Taylor

Taylor 5341N User manual

Taylor OMG 812 User manual

Taylor

Taylor OMG 812 User manual

Taylor 9842FDA User manual

Taylor

Taylor 9842FDA User manual

Taylor 1488 User manual

Taylor

Taylor 1488 User manual

Taylor TruTemp Manual

Taylor

Taylor TruTemp Manual

Taylor 522 User manual

Taylor

Taylor 522 User manual

Taylor Digital Folding Probe Thermometer User manual

Taylor

Taylor Digital Folding Probe Thermometer User manual

Taylor 9306 User manual

Taylor

Taylor 9306 User manual

Taylor 9877FDA User manual

Taylor

Taylor 9877FDA User manual

Taylor 518 User manual

Taylor

Taylor 518 User manual

Taylor 5458 User manual

Taylor

Taylor 5458 User manual

Taylor 1442 User manual

Taylor

Taylor 1442 User manual

Taylor 9526 User manual

Taylor

Taylor 9526 User manual

Taylor 1700 User manual

Taylor

Taylor 1700 User manual

Taylor 1479 User manual

Taylor

Taylor 1479 User manual

Taylor 3504 Owner's manual

Taylor

Taylor 3504 Owner's manual

Taylor 1497 User manual

Taylor

Taylor 1497 User manual

Taylor 9715L User manual

Taylor

Taylor 9715L User manual

Taylor SmarTemp Operating manual

Taylor

Taylor SmarTemp Operating manual

Taylor 505 User manual

Taylor

Taylor 505 User manual

Taylor Five Star 1479 User manual

Taylor

Taylor Five Star 1479 User manual

Taylor WeatherGuide 1521 User manual

Taylor

Taylor WeatherGuide 1521 User manual

Taylor 5535E User manual

Taylor

Taylor 5535E User manual

Popular Thermometer manuals by other brands

Benetech GM900 instruction manual

Benetech

Benetech GM900 instruction manual

Parton PTD-400 manual

Parton

Parton PTD-400 manual

GAME 15900 owner's manual

GAME

GAME 15900 owner's manual

scigiene FP-180 instruction manual

scigiene

scigiene FP-180 instruction manual

Ametek Land UNO U1 600/1600C-L user guide

Ametek Land

Ametek Land UNO U1 600/1600C-L user guide

Delton 981A instruction manual

Delton

Delton 981A instruction manual

Baker MM2P instruction manual

Baker

Baker MM2P instruction manual

Chino IR-FA Series instructions

Chino

Chino IR-FA Series instructions

Vive DMD1010 user manual

Vive

Vive DMD1010 user manual

Tarmo 320281 manual

Tarmo

Tarmo 320281 manual

Citizen CTD 504 instruction manual

Citizen

Citizen CTD 504 instruction manual

TFA 14.1500 instruction manual

TFA

TFA 14.1500 instruction manual

Gotemp THB4002 user guide

Gotemp

Gotemp THB4002 user guide

GREISINGER G 1202 Quick reference guide

GREISINGER

GREISINGER G 1202 Quick reference guide

Amprobe TMD-53W user manual

Amprobe

Amprobe TMD-53W user manual

Trotec BP10 operating manual

Trotec

Trotec BP10 operating manual

Radiance instruments RT616 Series product manual

Radiance instruments

Radiance instruments RT616 Series product manual

Eurolec IR151 operating instructions

Eurolec

Eurolec IR151 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

5296652
Digital Folding K-Type Thermocouple with Replaceable Probe
Thank you for purchasing a Taylor® Digital Folding K-Type Thermocouple. Please read this
instruction manual carefully before use. Keep these instructions handy for future reference.
Please remember to keep the unit away from children and do not use it for safety related
applications.
THERMOCOUPLE PROBE REPLACEMENT
To replace the K-type thermocouple probe, unfold the probe to open position. Turn screw
cap counterclockwise to loosen and remove. Gently pull probe in an outward direction to
remove. Insert new probe, aligning the "+" and "-" polarity symbols. Replace screw cap,
turn clockwise to tighten.
DIGITAL FOLDING THERMOCOUPLE PROBE FUNCTION
To turn the unit on, unfold the probe to an open position (between a 45° -180° degree angle).
A motion sensor within the unit will re-illuminate the back-light, pick up or gently shake the
thermometer to activate. The unit will continuously display temperatures for up to 10
minutes. After that, the unit will automatically shut off to preserve battery life. Or, to turn off
manually, fold the probe to a closed position.
1. Placing stress on the probe may cause breakage.
2. After measuring high temperatures, the probe may remain HOT for a while. Allow the
probe to cool before touching.
3. Use caution while handling the probe to avoid injury. Keep probe out of reach of
children.
The probe may be damaged if used to measure a temperature that exceeds the
specification of the measurement temperature range.
To avoid electric shock and thermometer damage, do not measure a live circuit where
the voltage exceeds 24V AC RMS or 60V CD with the thermocouple probe.
°F OR °C MODE
To switch between ‘°F’ and ‘°C’, unfold probe to open position, rotate unit left to right three
times in a row. Or, loosen screws on the battery compartment cover, remove the cover and
press ºF/ºC button
BACKLIGHT FEATURE
The backlight will activate for 15 seconds when the unit is in the open position.
LCD ERROR MESSAGES
The thermocouple incorporates visual diagnostic messages as follows:
‘Hi’ or ’Lo’
is displayed when the temperature being measured is outside of
the measurement range.
‘bAt’
indicates a low battery warning. Replace both batteries at the same
time.
‘
"Er3" is displayed when the entire unit has been exposed to ambient
temperature below 32ºF (0ºC) or above 122ºF (50ºC). Allow
approximately 30 minutes for the unit to stabilize back to working room
temperature.
BATTERY INSTALLATION
The thermocouple operates on 2 AAA batteries (included).
1. Remove any plastic wrap from the batteries before proceeding.
2. Loosen the screws on the battery compartment cover on the back of the
thermocouple and remove the cover.
3. Install 2 “AAA” batteries into the battery compartment according to the “+” and “-”
polarity symbols in the battery compartment.
4. Replace the battery compartment cover and tighten the screws.
CAUTION: When batteries of different brand or type are used together, or new and old
batteries are used together, some batteries may be over-discharged due to
difference of voltage or capacity. This can result in venting, leakage, and rupture
and may cause personal injury.
NOTE: Please recycle or dispose of batteries correctly per local regulations.
WARNING: Batteries may pose a choking hazard. Do not let children hand batteries. Keep
batteries away from children. If swallowed, seek medical attention immediately
PRECAUTION: Do not dispose of the unit or batteries in fire, as the batteries inside this unit
may explode or leak. Remove the batteries if the product will not be used for along period of
time. Remove used batteries promptly. Clean the battery contacts and also those of the
device prior to battery installation.
STORAGE & CLEANING
Take care when cleaning the thermocouple, using only a soft cloth or cotton swab with
water or medical alcohol, and allow the thermocouple to fully dry before using it. Do not
submerge any part of the thermocouple. The thermocouple should be stored at room
temperature between -4 to +140°F (-20 to +60°C).
SPECIFICATIONS
Item
Digital Folding K-Type Thermocouple
Probe Measurement Range
-40°F to 500°F (-40°C to 260°C)
Operating Range
32 to122°F (0 to 50°C)
Resolution
0.1°F (0.1°C)
Probe Accuracy
±1% of reading or 1°F (1°C)
Battery Life
Typically 40 hours, minimum 30 hours continuous use
Batteries
2 AAA batteries
Display
LCD 1.57x0.75 inch (40x19mm)
Dimensions
6.42x1.93x1.06 inch (163x49x26.9mm)
Probe length
3.3” (8.382cm)
IPX7 Waterproof Rating
IPX7 when the battery door is properly closed and the
probe is properly attached
EMC/RFI
Readings may be affected if the unit is operated within a radio frequency electromagnetic
field strength of approximately 3 volts per meter, but the performance of the instrument will
not be permanently affected.
DO NOT keep the unit too close to objects that continuously generate high heat (such as
a hot plate) for long periods of time. This may cause the unit to overheat.
CARE AND PRECAUTIONS
1. Always read instructions thoroughly to ensure that you have the full benefit of all
the unit's features.
2. Keep thermometer and probe out of reach of all children.
3. DO NOT immerse unit in water, as doing so will cause damage to internal components
and void the warranty. If you spill liquid on it, dry it immediately with a soft, lint-free
cloth. The unit is not dishwasher safe. Damage will void warranty.
4. DO NOT clean the unit with an abrasive or corrosive material. This may scratch the
plastic parts and corrode the electronic circuits.
5. DO NOT subject the units to excessive force, shock, dust, temperature or humidity.
This may result in malfunction, shorter electronic life span, damaged battery and
distorted parts.
6. DO NOT operate or store the unit in high temperature or humidity conditions. The
heat or moisture may interfere with the unit’s internal components. Store the unit at
temperatures between -4 and +140°F (–20 and +60°C).
7. DO NOT tamper with the unit's internal components. Doing so will invalidate the
warranty on the unit and may cause damage. The unit contains no user-serviceable
parts.
8. This unit operates on 2 AAA batteries. Always purchase the correct size and grade of
battery most suitable for the intended use. Always replace both batteries at the
same time; do not combine old and new batteries. Do not mix Alkaline, carbon-zinc
(standard) or Nickel-Cadmium (rechargeable) batteries.
Two Year Limited Warranty
Taylor warrants this product to be free from defects in materials or workmanship for two (2) years
(excluding batteries) for the original purchaser from date of original purchase. It does not cover
damages or wear resulting from accident, misuse, abuse, commercial use, or unauthorized adjustment
and/or repair. If service is required, do not return to distributor. For service, call between 7:30 AM and
4:30 PM, Mountain Standard Time, Monday through Friday. To assist us in servicing you, please have the
model number and date of purchase available. Should this product require service (or replacement at
our option), please pack the item carefully and return it prepaid, along with receipt showing date of
purchase and a note explaining reason for return to:
Taylor, a division of Lifetime Brands, Inc.
2220 Entrada del Sol, Suite A
Las Cruces, New Mexico 88001
Customer Service Phone: 1-800-225-4834
Customer Service Fax: 1-575-526-4347
www.taylorusa.com
There are no expressed warranties except as listed above. This warranty gives you specific legal rights,
and you may have other rights which vary from state to state.
For additional product information, or warranty information outside the USA, please contact us through
www.taylorusa.com.
© 2022 Taylor, a division of Lifetime Brands, Inc. All rights reserved.
Made to our exact specifications in China.
5296652 8.22 WC