Thank you for purchasing a Taylor® infrared thermometer. Please read this instruction manual carefully before use.
Keeptheseinstructionshandyforfuturereference.
Thethermometerisanoncontactinfraredthermometer.Simplyaimthethermometeratthetargetandpressthe‘Scan
key’ todisplaythesurfacetemperature.
Temperature Reading Operation
Press the ‘Scan key’ to take a temperature
reading. The unit will display the
temperature of the target for 10 seconds
then turn off automatically.
CAUTION!
1. WHEN DEVICE IS IN USE, DO NOT
LOOK DIRECTLY INTO THE LASER
BEAM–PERMANENT EYE DAMAGE
MAY RESULT.
2. USE EXTREME CAUTION WHEN
OPERATING THE LASER.
3. NEVER POINT THE DEVICE TOWARDS
ANYONE’S EYES.
4. KEEP OUT OF REACH OF ALL CHILDREN.
Continuous Temperature Reading Operation
1.Press andholddown the “Scan”key.
2. Theunitwilldisplaycontinuallyupdatedrealtime temperature readingswhilethe “Scan” keyishelddown.Whenthe
keyisreleased,thelasttemperaturewilldisplayfor10seconds,and thentheunitwillturnoffautomatically.
HACCP CHECK
The “HACCP CHECK” feature is incorporated in our thermometer
temperaturetographicallyindicatecriticaltemperaturezone.Theiconsand
LED indicators located above the display indicate if a food product is ina
safeorunsafeHACCP “DangerZone”temperature.ThegreenandredLED
lightwillalwaysbelitbefore the power isturned off.
A Green LED light with a ” ” icon indicates a safe cool or frozen
condition below 40
o
F (4
o
C), while a ” ” icon indicates a safe holding
temperatureabove 140
o
F (60
o
C).
When the temperature is between 40
o
F (4
o
C) and 140
o
F (60
o
C), the red
LEDwith a” ”iconwillappearandindicatethatthetemperatureisfallenwithintheHACCP“DangerZone”from40
o
to 140
o
F (4~60
o
C).
°C OR °F MODE
Tochangethethermometerfrom‘°C’to‘°F’orfrom‘°F’to‘°C’,firstturntheinstrumentonbypressingthe‘Scankey’,
thenpressthe ‘Modekey’onetime. The‘°C’ or ‘°F’ symbolwillflash. Pressthe ‘Scankey’ tochangetoscale.
EMISSIVITY RANGE
The infrared thermometer is supplied with a default emissivity of 0.95. The emissivity of the thermometer can be
changed from 0.05 (5E) to 1 (100E). Changesshould only be carried out by experienced personnel.To change the
emissivity, firstly turn the instrument on by pressing the ‘Scan’ button, then press the ‘Mode’ button two times for
emissivityfunction.The95EwillflashontheLCDscreen,thenpressthe‘Meas.’buttontoadjusttheemissivityvalue,
pressthe ‘Mode’button again to exit theset upscreen. Forinformation relating tothe emissivity ofspecific materials,
pleasecontactthenearestretailer.Note:noncontactinfraredthermometersarenotrecommendedforuseinmeasuring
the temperatureofshinyorpolishedmetals.
BAR DISPLAY: The fixed setting range for bar display is 68428°F (20~220°C) and Center=248°F (120°C).
Thebardisplaywillbeupdatedcomplywiththemeasurementreadingchanged.
LCD ERROR MESSAGES
Thethermometerincorporatesvisualdiagnosticmessagesasfollows:
「 」
「 」
‘Hi’ or ’Lo’ is displayed when the temperature being measured is outside of the range of the
instrument, ‘Hi’ whenhigherthan+662°F (+350°C)and ‘Lo’ whenlowerthan 67°F (–55°C).
「 」
「 」
‘Er2’isdisplayedwhenthethermometerisexposedtorapidchangesintheambienttemperature.
‘Er3’ is displayed whentheambient temperature ofthe thermometer EXCEEDS 32°F (0°C) OR
+122°F (+50°C). In both cases you should allow plenty of time (minimum 30 minutes) for the
thermometerto stabilize totheworking/roomtemperature.
「 」
Forallothererrormessagesit is necessarytoresetthethermometer.Toresetthethermometer,
turnthe instrument off, remove the battery and wait for aminimum ofone minute, reinsert the
battery and turn on. Ifthe error messageremains, please contact CustomerService for further
assistance.
BATTERIES
Thethermometerincorporatesvisuallowbatteryindicationasfollows:
‘BatteryOK’:
measurements
arepossible
‘BatteryLow’:batteryneedsto
bereplaced,measurements
arepossible
‘BatteryExhausted’:
measurementsare
notpossible
Whenthe ‘LowBattery’ iconindicatesthebatteryislow,thebatteryshouldbereplacedimmediately
with 2 AAA,1.5Vbatteries.Pleasenote:Itisimportanttoturntheinstrumentoffbeforereplacingthe
batteries, otherwisethethermometermaymalfunction.
Whenreplacingthebatteries,donotmixoldandnewbatteries.Donotmixalkalinestandard
(carbonzinc)orrechargeable(nickelcadmium)batteries. Disposeofbatteriesproperly.Donotdisposeof
unitorbatteriesinfire,asbatteriesinsidethisunitmayexplodeorleak.Keepawayfromchildren.
STORAGE & CLEANING
Thesensorlensisthemostdelicatepartofthethermometer.Thelensshouldbekeptcleanatalltimes.Takecare when
cleaning the lens, using only asoft cloth or cotton swab with wateror medical alcohol, and allowthe lens to fully dry
beforeusingit.Donotsubmergeanypartofthethermometer.Thethermometershouldbestoredatroomtemperature
between 4to+149°F (20 to+65°C).
SPECIFICATIONS
MeasurementRange 67~662°F (55to+350°C)
OperatingRange 32~122°F(0~50°C)
Accuracy(Tobj=1535°C,Tamb=25°C) +/1.8°F (1.0°C)
Accuracy(Tobj=33~350o
C,Tamb=23±3o
C) ±2%ofreadingor4°F (2°C) whicheverisgreater
Resolution67.0~390.0°F) (55.0~199.9°C) 0.1°F / 0.1°C (switchable)
ResponseTime(90%) 1second
Distance:Spot 6:1opticsratio
EmissivityRange 0.95default –adjustable0.05to1.00emissivity
BatteryLife Typically40hr,minimum30hr (autopoweroffafter15seconds)
Battery 2 AAA
Dimensions 24.5 x43.5 x 113.5mm(1.0×1.7×4.5inch)
Weight 3.2oz(90grams) including batteries
EMC/RFI
Readingsmaybeaffectediftheunitisoperatedwithina radio frequencyelectromagneticfieldstrengthofapproximately
3voltsper meter,buttheperformanceoftheinstrumentwillnotbepermanentlyaffected.
OneYearLimitedWarranty
Taylorwarrantsthisproducttobefreefromdefectsinmaterialsorworkmanshipforone(1)year
fromdateof original purchase.Itdoesnotcoverdamagesorwearresultingfromaccident,misuse,
abuse,commercialuse,orunauthorizedadjustmentand/orrepair.
Ifserviceisrequired,donotreturntodistributor.Forservice,callbetween7:30AMand4:30PM,
MountainStandardTime, Mondaythrough Friday. To assist usin service you, please have the
modelnumberanddateofpurchase available.Shouldthisproductrequireservice(orreplacement
atouroption),pleasepacktheitemcarefullyandreturnitprepaid,alongwithreceiptshowingdate
ofpurchaseandanote explainingreasonforreturnto:
Taylor Precision Products
2220 Entrada del Sol, Suite A
Las Cruces, New Mexico 88001
Customer Service Phone: 18002254834
Customer Service Fax: 15755264347
www.taylorusa.com
Therearenoexpressedwarrantiesexceptaslistedabove.Thiswarrantygivesyouspecificlegal
rights,andyoumayhaveotherrightswhichvaryfromstatetostate.
.
© 2006 Taylor Precision Products and its affiliated companies, all rights reserved. Taylor® and
Leading the Way in Accuracy® are registered trademarks of Taylor Precision Products and its
affiliatedcompanies.Allrightsreserved.
MadetoourexactspecificationsinChina.

Other manuals for 9715L

1

Other Taylor Thermometer manuals

Taylor 9848FDA / 806 User manual

Taylor

Taylor 9848FDA / 806 User manual

Taylor 3504 Owner's manual

Taylor

Taylor 3504 Owner's manual

Taylor 9526 User manual

Taylor

Taylor 9526 User manual

Taylor 5341N User manual

Taylor

Taylor 5341N User manual

Taylor SmarTemp Operating manual

Taylor

Taylor SmarTemp Operating manual

Taylor 1442 User manual

Taylor

Taylor 1442 User manual

Taylor 5535E User manual

Taylor

Taylor 5535E User manual

Taylor 9867S User manual

Taylor

Taylor 9867S User manual

Taylor 518 User manual

Taylor

Taylor 518 User manual

Taylor 519 User manual

Taylor

Taylor 519 User manual

Taylor Digital Folding Probe Thermometer User manual

Taylor

Taylor Digital Folding Probe Thermometer User manual

Taylor 9842FDA User manual

Taylor

Taylor 9842FDA User manual

Taylor 519 User manual

Taylor

Taylor 519 User manual

Taylor Weekend Warrior 805 Owner's manual

Taylor

Taylor Weekend Warrior 805 Owner's manual

Taylor WeatherGuide User manual

Taylor

Taylor WeatherGuide User manual

Taylor OMG 808 User manual

Taylor

Taylor OMG 808 User manual

Taylor 1497 User manual

Taylor

Taylor 1497 User manual

Taylor 1488 User manual

Taylor

Taylor 1488 User manual

Taylor WeatherGuide 1520 User manual

Taylor

Taylor WeatherGuide 1520 User manual

Taylor 147921 User manual

Taylor

Taylor 147921 User manual

Taylor Five Star 1479 User manual

Taylor

Taylor Five Star 1479 User manual

Taylor 505 User manual

Taylor

Taylor 505 User manual

Taylor 1431 User manual

Taylor

Taylor 1431 User manual

Taylor 9842 User manual

Taylor

Taylor 9842 User manual

Popular Thermometer manuals by other brands

Braun ThermoScan Calibration manual

Braun

Braun ThermoScan Calibration manual

Vital Baby PROTECT HTD8216C quick start guide

Vital Baby

Vital Baby PROTECT HTD8216C quick start guide

Gurin TS-110 user manual

Gurin

Gurin TS-110 user manual

Center 318 instruction manual

Center

Center 318 instruction manual

Medisana 48618 manual

Medisana

Medisana 48618 manual

Vega Technologies SC 25 manual

Vega Technologies

Vega Technologies SC 25 manual

BabyOno 613 manual

BabyOno

BabyOno 613 manual

PACOM PC868 user manual

PACOM

PACOM PC868 user manual

Avita TS21 instruction manual

Avita

Avita TS21 instruction manual

Domotherm OT Instructions for use

Domotherm

Domotherm OT Instructions for use

Huato HE2 A Series Operation manual

Huato

Huato HE2 A Series Operation manual

Hanna Instruments HI 9061 instruction manual

Hanna Instruments

Hanna Instruments HI 9061 instruction manual

Chauvin Arnoux C.A 1860 user manual

Chauvin Arnoux

Chauvin Arnoux C.A 1860 user manual

Value HT11 Series manual

Value

Value HT11 Series manual

Westfalia KT203I instruction manual

Westfalia

Westfalia KT203I instruction manual

PCE Health and Fitness PCE-TC 24 user manual

PCE Health and Fitness

PCE Health and Fitness PCE-TC 24 user manual

Fluke 1620A-H user guide

Fluke

Fluke 1620A-H user guide

Safe and Sound Products SA8097 quick guide

Safe and Sound Products

Safe and Sound Products SA8097 quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.