manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Taylor
  6. •
  7. Thermometer
  8. •
  9. Taylor 9715L User manual

Taylor 9715L User manual

Other manuals for 9715L

1

Other Taylor Thermometer manuals

Taylor 9523 User manual

Taylor

Taylor 9523 User manual

Taylor 5109 User manual

Taylor

Taylor 5109 User manual

Taylor 5286498 User manual

Taylor

Taylor 5286498 User manual

Taylor 1488 User manual

Taylor

Taylor 1488 User manual

Taylor 519 User manual

Taylor

Taylor 519 User manual

Taylor 519 User manual

Taylor

Taylor 519 User manual

Taylor 5458 User manual

Taylor

Taylor 5458 User manual

Taylor OMG 808 User manual

Taylor

Taylor OMG 808 User manual

Taylor 806E User manual

Taylor

Taylor 806E User manual

Taylor 9842FDA User manual

Taylor

Taylor 9842FDA User manual

Taylor 5296652 User manual

Taylor

Taylor 5296652 User manual

Taylor 505 User manual

Taylor

Taylor 505 User manual

Taylor 9526 User manual

Taylor

Taylor 9526 User manual

Taylor 522 User manual

Taylor

Taylor 522 User manual

Taylor WeatherGuide System User manual

Taylor

Taylor WeatherGuide System User manual

Taylor 1497 User manual

Taylor

Taylor 1497 User manual

Taylor 518 User manual

Taylor

Taylor 518 User manual

Taylor WeatherGuide 1520 User manual

Taylor

Taylor WeatherGuide 1520 User manual

Taylor 6700 User manual

Taylor

Taylor 6700 User manual

Taylor 9842 User manual

Taylor

Taylor 9842 User manual

Taylor 1431 User manual

Taylor

Taylor 1431 User manual

Taylor 1730 User manual

Taylor

Taylor 1730 User manual

Taylor WeatherGuide User manual

Taylor

Taylor WeatherGuide User manual

Taylor 1542 User manual

Taylor

Taylor 1542 User manual

Popular Thermometer manuals by other brands

Benetech GM900 instruction manual

Benetech

Benetech GM900 instruction manual

Parton PTD-400 manual

Parton

Parton PTD-400 manual

GAME 15900 owner's manual

GAME

GAME 15900 owner's manual

scigiene FP-180 instruction manual

scigiene

scigiene FP-180 instruction manual

Ametek Land UNO U1 600/1600C-L user guide

Ametek Land

Ametek Land UNO U1 600/1600C-L user guide

Delton 981A instruction manual

Delton

Delton 981A instruction manual

Baker MM2P instruction manual

Baker

Baker MM2P instruction manual

Chino IR-FA Series instructions

Chino

Chino IR-FA Series instructions

Vive DMD1010 user manual

Vive

Vive DMD1010 user manual

Tarmo 320281 manual

Tarmo

Tarmo 320281 manual

Citizen CTD 504 instruction manual

Citizen

Citizen CTD 504 instruction manual

TFA 14.1500 instruction manual

TFA

TFA 14.1500 instruction manual

Gotemp THB4002 user guide

Gotemp

Gotemp THB4002 user guide

GREISINGER G 1202 Quick reference guide

GREISINGER

GREISINGER G 1202 Quick reference guide

Amprobe TMD-53W user manual

Amprobe

Amprobe TMD-53W user manual

Trotec BP10 operating manual

Trotec

Trotec BP10 operating manual

Radiance instruments RT616 Series product manual

Radiance instruments

Radiance instruments RT616 Series product manual

Eurolec IR151 operating instructions

Eurolec

Eurolec IR151 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

T
Ta
ay
yl
lo
or
r®
® 9
97
71
15
5L
L T
Th
he
er
rm
mo
om
me
et
te
er
r O
Op
pe
er
ra
at
ti
in
ng
g I
In
ns
st
tr
ru
uc
ct
ti
io
on
ns
s
Thank you for purchasing a Taylor® infrared thermometer. Please read this instruction manual carefully before use.
Keeptheseinstructionshandyforfuturereference.
Thethermometerisanoncontactinfraredthermometer.Simplyaimthethermometeratthetargetandpressthe‘Scan
key’ todisplaythesurfacetemperature.
Temperature Reading Operation
Press the ‘Scan key’ to take a temperature
reading. The unit will display the
temperature of the target for 10 seconds
then turn off automatically.
CAUTION!
1. WHEN DEVICE IS IN USE, DO NOT
LOOK DIRECTLY INTO THE LASER
BEAM–PERMANENT EYE DAMAGE
MAY RESULT.
2. USE EXTREME CAUTION WHEN
OPERATING THE LASER.
3. NEVER POINT THE DEVICE TOWARDS
ANYONE’S EYES.
4. KEEP OUT OF REACH OF ALL CHILDREN.
Continuous Temperature Reading Operation
1.Press andholddown the “Scan”key.
2. Theunitwilldisplaycontinuallyupdatedrealtime temperature readingswhilethe “Scan” keyishelddown.Whenthe
keyisreleased,thelasttemperaturewilldisplayfor10seconds,and thentheunitwillturnoffautomatically.
HACCP CHECK
The “HACCP CHECK” feature is incorporated in our thermometer
temperaturetographicallyindicatecriticaltemperaturezone.Theiconsand
LED indicators located above the display indicate if a food product is ina
safeorunsafeHACCP “DangerZone”temperature.ThegreenandredLED
lightwillalwaysbelitbefore the power isturned off.
A Green LED light with a ” ” icon indicates a safe cool or frozen
condition below 40
o
F (4
o
C), while a ” ” icon indicates a safe holding
temperatureabove 140
o
F (60
o
C).
When the temperature is between 40
o
F (4
o
C) and 140
o
F (60
o
C), the red
LEDwith a” ”iconwillappearandindicatethatthetemperatureisfallenwithintheHACCP“DangerZone”from40
o
to 140
o
F (4~60
o
C).
°C OR °F MODE
Tochangethethermometerfrom‘°C’to‘°F’orfrom‘°F’to‘°C’,firstturntheinstrumentonbypressingthe‘Scankey’,
thenpressthe ‘Modekey’onetime. The‘°C’ or ‘°F’ symbolwillflash. Pressthe ‘Scankey’ tochangetoscale.
EMISSIVITY RANGE
The infrared thermometer is supplied with a default emissivity of 0.95. The emissivity of the thermometer can be
changed from 0.05 (5E) to 1 (100E). Changesshould only be carried out by experienced personnel.To change the
emissivity, firstly turn the instrument on by pressing the ‘Scan’ button, then press the ‘Mode’ button two times for
emissivityfunction.The95EwillflashontheLCDscreen,thenpressthe‘Meas.’buttontoadjusttheemissivityvalue,
pressthe ‘Mode’button again to exit theset upscreen. Forinformation relating tothe emissivity ofspecific materials,
pleasecontactthenearestretailer.Note:noncontactinfraredthermometersarenotrecommendedforuseinmeasuring
the temperatureofshinyorpolishedmetals.
BAR DISPLAY: The fixed setting range for bar display is 68428°F (20~220°C) and Center=248°F (120°C).
Thebardisplaywillbeupdatedcomplywiththemeasurementreadingchanged.
LCD ERROR MESSAGES
Thethermometerincorporatesvisualdiagnosticmessagesasfollows:
「 」
「 」
‘Hi’ or ’Lo’ is displayed when the temperature being measured is outside of the range of the
instrument, ‘Hi’ whenhigherthan+662°F (+350°C)and ‘Lo’ whenlowerthan 67°F (–55°C).
「 」
「 」
‘Er2’isdisplayedwhenthethermometerisexposedtorapidchangesintheambienttemperature.
‘Er3’ is displayed whentheambient temperature ofthe thermometer EXCEEDS 32°F (0°C) OR
+122°F (+50°C). In both cases you should allow plenty of time (minimum 30 minutes) for the
thermometerto stabilize totheworking/roomtemperature.
「 」
Forallothererrormessagesit is necessarytoresetthethermometer.Toresetthethermometer,
turnthe instrument off, remove the battery and wait for aminimum ofone minute, reinsert the
battery and turn on. Ifthe error messageremains, please contact CustomerService for further
assistance.
BATTERIES
Thethermometerincorporatesvisuallowbatteryindicationasfollows:
‘BatteryOK’:
measurements
arepossible
‘BatteryLow’:batteryneedsto
bereplaced,measurements
arepossible
‘BatteryExhausted’:
measurementsare
notpossible
Whenthe ‘LowBattery’ iconindicatesthebatteryislow,thebatteryshouldbereplacedimmediately
with 2 AAA,1.5Vbatteries.Pleasenote:Itisimportanttoturntheinstrumentoffbeforereplacingthe
batteries, otherwisethethermometermaymalfunction.
Whenreplacingthebatteries,donotmixoldandnewbatteries.Donotmixalkalinestandard
(carbonzinc)orrechargeable(nickelcadmium)batteries. Disposeofbatteriesproperly.Donotdisposeof
unitorbatteriesinfire,asbatteriesinsidethisunitmayexplodeorleak.Keepawayfromchildren.
STORAGE & CLEANING
Thesensorlensisthemostdelicatepartofthethermometer.Thelensshouldbekeptcleanatalltimes.Takecare when
cleaning the lens, using only asoft cloth or cotton swab with wateror medical alcohol, and allowthe lens to fully dry
beforeusingit.Donotsubmergeanypartofthethermometer.Thethermometershouldbestoredatroomtemperature
between 4to+149°F (20 to+65°C).
SPECIFICATIONS
MeasurementRange 67~662°F (55to+350°C)
OperatingRange 32~122°F(0~50°C)
Accuracy(Tobj=1535°C,Tamb=25°C) +/1.8°F (1.0°C)
Accuracy(Tobj=33~350o
C,Tamb=23±3o
C) ±2%ofreadingor4°F (2°C) whicheverisgreater
Resolution67.0~390.0°F) (55.0~199.9°C) 0.1°F / 0.1°C (switchable)
ResponseTime(90%) 1second
Distance:Spot 6:1opticsratio
EmissivityRange 0.95default –adjustable0.05to1.00emissivity
BatteryLife Typically40hr,minimum30hr (autopoweroffafter15seconds)
Battery 2 AAA
Dimensions 24.5 x43.5 x 113.5mm(1.0×1.7×4.5inch)
Weight 3.2oz(90grams) including batteries
EMC/RFI
Readingsmaybeaffectediftheunitisoperatedwithina radio frequencyelectromagneticfieldstrengthofapproximately
3voltsper meter,buttheperformanceoftheinstrumentwillnotbepermanentlyaffected.
OneYearLimitedWarranty
Taylorwarrantsthisproducttobefreefromdefectsinmaterialsorworkmanshipforone(1)year
fromdateof original purchase.Itdoesnotcoverdamagesorwearresultingfromaccident,misuse,
abuse,commercialuse,orunauthorizedadjustmentand/orrepair.
Ifserviceisrequired,donotreturntodistributor.Forservice,callbetween7:30AMand4:30PM,
MountainStandardTime, Mondaythrough Friday. To assist usin service you, please have the
modelnumberanddateofpurchase available.Shouldthisproductrequireservice(orreplacement
atouroption),pleasepacktheitemcarefullyandreturnitprepaid,alongwithreceiptshowingdate
ofpurchaseandanote explainingreasonforreturnto:
Taylor Precision Products
2220 Entrada del Sol, Suite A
Las Cruces, New Mexico 88001
Customer Service Phone: 18002254834
Customer Service Fax: 15755264347
www.taylorusa.com
Therearenoexpressedwarrantiesexceptaslistedabove.Thiswarrantygivesyouspecificlegal
rights,andyoumayhaveotherrightswhichvaryfromstatetostate.
.
© 2006 Taylor Precision Products and its affiliated companies, all rights reserved. Taylor® and
Leading the Way in Accuracy® are registered trademarks of Taylor Precision Products and its
affiliatedcompanies.Allrightsreserved.
MadetoourexactspecificationsinChina.