THERMOMETER 931A, 932A, 1031A, 1032A
Data Thermometer Quick Start Guide
To access the TEGAM Cloud
and view saved measurement data:
1. Go to tegamcloud.com;
2. Click Login on the home page; This opens a user/password window;
3. Click Login to accept the pre-filled user name and password,
and access the default TEGAMUser account;
If a personalized user account has already been created for your
organization, enter the appropriate username and password to access
that account.
4. Click View Data to access your saved measurement data;
5. Click Select Device and choose your Data Thermometer’s serial number
from the drop-down list;
6. Click Create Chart to display your saved measurement data.
CONGRATULATIONS!
YOU’RE READY to make and record accurate temperature
measurements, wherever and whenever you may need to.
We know you are eager to begin using your new thermometer, but this quick
start guide is just the beginning. Please take a moment to familiarize yourself
with the Operation Manual to learn about all the features and benefits of your
new TEGAM Data Thermometer.
10 TEGAM Way •Geneva, Ohio 44041
Phone: 440-466-6100 •Fax: 440-466-6110 •E-mail: [email protected]
www.tegam.com
1. Install batteries.
Battery Installation
Remove the two (2) battery compartment
retaining screws and the battery compartment
cover on the back of the instrument. Install
three (3) AA 1.5 V batteries (supplied with new
instrument). Be sure the battery compartment
gasket is properly installed and replace the
battery cover.
2. Press to turn the instrument on.
3. Connect a compatible temperature probe to the Channel 1 and/or
Channel 2 input connector located at the top of the instrument.
4. Set the desired thermocouple type and temperature units as follows:
a. Enter Setup Menu by pressing – hold key down for approximately
1.5 seconds, and then release it;
b. The Active Thermocouple Type will flash on the display. Use to
select the thermocouple type of the connected temperature probe
(E, J, K, or T);
c. Press (do not hold) to save selection and move to next parameter;
d. The Active Temperature Unit will flash on the display. Use to select
the desired temperature unit (°C, °F, or K);
e. Press (do not hold) to save selection and exit Setup Menu.
5. To begin collecting temperature data that will be stored in the thermometer’s
onboard memory, press .
Retaining Screws
Battery
Compartment
Gasket
Recording Temperature Data
The TEGAM Mobile App provides convenient two-way
communication between your TEGAM Data Thermometer
and compatible Bluetooth®low energy technology / version
4.0 mobile devices. The TEGAM Mobile App duplicates
the Data Thermometer display for easy monitoring from
up to 30 feet away, and provides real-time measurement
charting for both channels. See Figure 1 below for a
description of the mobile app user interface.
The TEGAM Mobile App is also the gateway to the TEGAM Cloud™
(tegamcloud.com), where you can save, store, review, analyze, and
download, all your measurement data. Once created, your account on the
TEGAM Cloud can be personalized to meet your organization’s needs with
user-created locations, custom data filtering, and measurement charting.
Both the TEGAM Mobile App and TEGAM Cloud are provided free to TEGAM
customers for use with TEGAM Data Thermometers. If your organization
has specific or unique data storage, interface, or security requirements,
please contact TEGAM to discuss TEGAM Cloud customization options.
Open or close the mobile app menu
Interface View real-time measurement data
Control most Data Thermometer features
Logging View instrument connection state, model,
serial number, and the active user account
and location
Manually record a temperature measurement
Chart Real-time chart of current temperature
measurement for each active channel
Clock View instrument connection state and
current mobile device date and time
Manually set instrument date and time
from user-input date and time
Automatically set instrument date and time
from mobile device time
Pairing View available Data Thermometers
Pair mobile device to Data Thermometer
Clear pairing to a paired Data Thermometer
Account View or change current account information
Create
Account
Create a new user account on the
TEGAM Cloud
Figure 1: TEGAM Mobile App User Interface Description
To connect to the TEGAM Mobile App
using the default account:
The TEGAM Mobile App is initially set to save data to a default TEGAM Cloud
account, the TEGAMUser account. This is a public account accessible by
all TEGAM Data Thermometer users, and should not be used for production
measurement data. Before saving critical or sensitive temperature data,
create a personalized account with a strong password through the mobile
app or TEGAM Cloud.
1. Before beginning, ensure your mobile device is Bluetooth low energy
technology / version 4.0 compatible and has an active internet
connection;
2. Visit the Google Play™ store or iTunes and search for TEGAM to
download the TEGAM Mobile App;
3. Install the mobile app to your device and accept the license
agreement and permissions requests;
4. Verify that Bluetooth communication is active on your mobile device;
5. On your Data Thermometer, press to turn Bluetooth communication on;
The display Bluetooth icon will flash, indicating the instrument is in
pairing mode.
6. On the mobile app, touch and select Pairing;
7. In the displayed list of available instruments, touch the entry that
corresponds to your Data Thermometer’s MAC address (located
on back of instrument) and touch Yes in the resulting dialogue box;
The display Bluetooth icon will steadily illuminate, indicating the
instrument is paired to the mobile device.
8. Touch and select Interface to monitor real-time temperature
measurements and to remotely control your Data Thermometer;
9. Touch on the mobile app, or press on your Data Thermometer,
to begin automatic data collection at the programmed measurement
acquisition interval (default is 10 S).
TEGAM Cloud™ is a trademark of TEGAM. The Bluetooth®word, mark, and logos are registered
trademarks owned by Bluetooth SIG, Inc. and use of such marks by TEGAM, Inc. is under license.
Google Play™ is a trademark of Google Inc. iTunes is a trademark of Apple Inc.
Thermometer Link

Other manuals for 932A

1

This manual suits for next models

3

Other Tegam Thermometer manuals

Tegam WG311 v3 User manual

Tegam

Tegam WG311 v3 User manual

Tegam 921B User manual

Tegam

Tegam 921B User manual

Tegam 911A User manual

Tegam

Tegam 911A User manual

Tegam 911A User manual

Tegam

Tegam 911A User manual

Tegam 921B User manual

Tegam

Tegam 921B User manual

Tegam 868 User manual

Tegam

Tegam 868 User manual

Tegam 865 User manual

Tegam

Tegam 865 User manual

Tegam 819A User manual

Tegam

Tegam 819A User manual

Tegam 940A User manual

Tegam

Tegam 940A User manual

Tegam 911A User manual

Tegam

Tegam 911A User manual

Tegam 840A User manual

Tegam

Tegam 840A User manual

Tegam 911B User manual

Tegam

Tegam 911B User manual

Tegam Budget 874F User manual

Tegam

Tegam Budget 874F User manual

Tegam 932A User manual

Tegam

Tegam 932A User manual

Tegam 931A User manual

Tegam

Tegam 931A User manual

Tegam 940A User manual

Tegam

Tegam 940A User manual

Popular Thermometer manuals by other brands

Microlife MT 1931 instruction manual

Microlife

Microlife MT 1931 instruction manual

Microlife IR210 manual

Microlife

Microlife IR210 manual

Philips DL8740 manual

Philips

Philips DL8740 manual

RS 53 II Operator's manual

RS

RS 53 II Operator's manual

Talktech MyDegrees manual

Talktech

Talktech MyDegrees manual

Conair CARE ITH94F user manual

Conair

Conair CARE ITH94F user manual

JOYTECH DMT-4735b owner's manual

JOYTECH

JOYTECH DMT-4735b owner's manual

iProven DMT-489 quick start guide

iProven

iProven DMT-489 quick start guide

Microlife NC150 BT manual

Microlife

Microlife NC150 BT manual

General IRT205 user manual

General

General IRT205 user manual

Milwaukee MI 805 user manual

Milwaukee

Milwaukee MI 805 user manual

Sea-Bird Electronics SBE 38 user manual

Sea-Bird Electronics

Sea-Bird Electronics SBE 38 user manual

BIOS Diagnostics 192DC quick start guide

BIOS Diagnostics

BIOS Diagnostics 192DC quick start guide

iHealth PT2L user manual

iHealth

iHealth PT2L user manual

Rossmax RA600 manual

Rossmax

Rossmax RA600 manual

Fluke VT04A Quick reference guide

Fluke

Fluke VT04A Quick reference guide

Omron EcoTemp instruction manual

Omron

Omron EcoTemp instruction manual

kENDALL FILAC 3000 AD operating manual

kENDALL

kENDALL FILAC 3000 AD operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.