Tema Telecomunicazioni AD638 User manual

AD638
2-way VoIP SIP 2 x 20W PoE Speaker
Serie Audio Over IP Network
PRODUCT MANUAL
Version HW 1.0 - Version SW 1.10
Revision
Date
Revision reason
Prepared
Checked/Approved
0 11/03/2018 First release MM, DP DP, FL
TEMA TELECOMUNICAZIONI
“IP COMMUNICATION AND SECURITY COMPANY”
WWW.TEMATLC.IT
Products for VoIP SIP LAN networking Communications, Paging Amplifiers Systems and
Audio Applications. Zone Announcements, Night Ringer, Multicast general call,
Background music, Standard SIP call or Emergency call, SD memory with pre-recorded
messages, Relays for LAN drives.

TEMA TELECOMUNICAZIONI
AD638 VoIP SIP Speaker 2x20W PoE
MAS-AD638-REV00EN Page 2 of 52
We, TEMA TELECOMUNICAZIONI SRL Via C. Girardengo, 1/4 - 20161 MILANO
declare under our sole responsibility that the product:
Product name
Diffusore a 2 vie VoIP SIP 2x20W PoE
Trade name TEMA TELECOMUNICAZIONI Srl
Type or model AD638
and accessories --
to which this declaration relates is in conformity with the essential requirements and other
relevant requirements of the R&TTE Directive ( 1999/5/EC, 2006/95/EC, 2004/108/EC ).
The product is in conformity with the followings standards and/or other normative documents:
HEALT & SAFETY EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011
EMC EN 55022:2010, EN 55024:2010, EN 61000-3-2:2006
EN 61000-3-3 :2008
MILANO, 11 March 2019 TEMA TELECOMUNICAZIONI SRL
D. Pontillo
I.
IMPORTANT INFORMATIONS REGARDING THE RECOVERY AND RECYCLING OF THIS
ELECTRONIC DEVICE
DICHIARAZIONE DI CONFORMITÀ CE
DECLARATION OF CONFORMITY CE
The crossed
-
out wheeled bin symbol below indicates that this electronic equipment is
intended to be disposed in a separate collection and not in an unsorted municipal
waste, in order to provide for the treatment of WEEE (Waste Electrical and Electronic
Equipment) using best available recovery and recycling techniques. Specific treatment
for WEEE is indispensable in order to avoid the dispersion of pollutants and other
hazardous substances into the waste stream, while recycling leads to reduction of
disposal of waste and the negative impacts on environment and human health. That is,
priority is given to reuse of WEEE in its components, subassemblies and
consumables. As the final holder, the user has an important role in contributing to
reuse, recycling and other forms of recovery of WEEE and is responsible to return this
waste in the collection facilities set up by EC Member States and to fulfill other duties
in compliance with Directive 2002/96/EC and local laws.
UNI EN ISO 9001:2015
TEMA TELECOMUNICAZIONI is a certified company

TEMA TELECOMUNICAZIONI
AD638 VoIP SIP Speaker 2x20W PoE
MAS-AD638-REV00EN Page 3 of 52
RECOMMENDATIONS
1. It is recommended to read this entire manual before proceeding to the installation of the device.
2. The installation and commissioning of the device can only be performed by specialized technicians.
3. The device is accurately manufactured and tested. In any case, the product is not recommended for use
where an error of operations can cause property damage and/or injury to persons.
4. It is expressly not recommended maintenance inside the device which must be carried out by Tema
Telecomunicazioni, the removal of the closures will invalidate the warranty and makes accessible internal
parts with risk of electric shock.
5. Tema Telecomunicazioni accepts no responsibility for damage to property and/or persons resulting from
incorrect use of the equipment or by procedures that do not comply with the instructions in this manual.
Tema Telecomunicazioni reserves the right to make modification to the technical and functional
specifications at any time and without any notice.
6. Products powered via PoE (Power over Ethernet) may only be connected with cables coming from the
internal network company (inside the building), are not allowed connections LAN cables coming from outside
the building.
7. Use for this device only and exclusively original spare parts and consumables supplied by Tema
Telecomunicazioni. The company is not responsible for damage caused by the use of materials not supplied
by the same.
8. Do not expose the unit to direct sunlight, protect from heat, dust, humidity and chemicals.
9. Tema Telecomunicazioni reserves the right to vary the product characteristics for improvement without prior
notice. Check the WWW.TEMATLC.IT website for any updates to the latest firmware, manuals, and
technical documentation.
10. This document is property of Tema Telecomunicazioni, It is forbidden any duplication and reproduction, even
partial, as well as storage on any medium without written permission of Tema Telecomunicazioni.
This symbol in the descriptions indicates a general warning or a damage danger
to equipment or people.
This symbol in the descriptions indicates useful information or a
suggestion for
the optimization of the device functionality.

TEMA TELECOMUNICAZIONI
AD638 VoIP SIP Speaker 2x20W PoE
MAS-AD638-REV00EN Page 4 of 52
1. PRESENTATION ........................................................................................................................................ 5
2. FEATURES.................................................................................................................................................. 8
3. PACKING LIST ........................................................................................................................................... 8
4. TECHNICAL SPECIFICATIONS ............................................................................................................... 9
5. OPERATION.............................................................................................................................................. 10
5.1.
D
EVICE CONNECTION DIAGRAMS
........................................................................................................................10
6. OPERATING MODES............................................................................................................................... 11
6.1.
C
ALLS TO DEVICES
...........................................................................................................................................11
6.2.
RELAY
FUNCTION
...........................................................................................................................................11
6.3.
A
LARM
I
NPUT
IN1:
CALLS GENERATED FOR ACQUISITION OF EXTERNAL CONTACTS FOR SPECIAL SIGNALINGS
.............11
6.4.
S
TREAMING
A
UDIO
M
ULTICAST
.........................................................................................................................12
7. COMMANDS AND CODES...................................................................................................................... 12
8. INSTALLATION OF THE DEVICE .......................................................................................................... 13
8.1.
M
OUNTING AND POSITIONING OF THE
AD638
SYSTEM
..........................................................................................13
8.2.
A
CCESSO TO THE REAR CONNECTORS
...............................................................................................................13
8.3.
C
ONNECTING THE
AD638
SPEAKER
...................................................................................................................14
8.4.
C
ORRECT CONNECTION OF AN ADDITIONAL PASSIVE SPEAKER
..............................................................................16
8.5.
100V
AUDIO LINE FOR ADDITIONAL SPEAKERS AWAY FROM
AD638
IP
S
PEAKER
.....................................................17
9. PROGRAMMING ...................................................................................................................................... 18
9.1.
P
REPARATION FOR THE SYSTEM PARAMETERS PROGRAMMING
..............................................................................18
9.2.
A
CCESS TO PROGRAMMING
...............................................................................................................................20
9.3.
N
ETWORK PARAMETERS
...................................................................................................................................21
9.4.
SIP
P
ARAMETERS
...........................................................................................................................................22
9.5.
G
ENERAL PARAMETERS
....................................................................................................................................23
9.6.
S
ET OF THE OPERATING MODE
..........................................................................................................................24
9.7.
R
ELAY AND ALARM INPUT SETTINGS
...................................................................................................................25
9.8.
C
AMERA
(
ONLY FOR
AA-500
IP
D
OORPHONES SERIES
) .......................................................................................27
9.9.
C
ALL BUTTONS
................................................................................................................................................28
9.10.
M
ESSAGES MANAGEMENT
...........................................................................................................................29
9.11.
A
UTOMATIC
A
NNOUNCEMENTS
.....................................................................................................................31
9.12.
C
ALLS
R
EPORT
..........................................................................................................................................33
10. MAINTENANCE........................................................................................................................................ 34
10.1.
S
YSTEM
....................................................................................................................................................34
10.2.
L
OGIN CREDENTIALS
...................................................................................................................................35
10.3.
D
IAGNOSTIC LOGS
......................................................................................................................................35
11. PRESENTATION AND USE OF THE "AA Video Console" SOFTWARE ........................................ 36
11.1.
P
RESENTATION
..........................................................................................................................................36
11.2.
S
OFTWARE CONFIGURATION FOR
SIP
S
ERVER MODE
.....................................................................................37
11.3.
S
OFTWARE CONFIGURATION FOR
P
EER
-T
O
-P
EER MODE
.................................................................................38
12. Introduction to AA-Video Console APP version for operating systems iOS............................... 39
12.1.
D
OWNLOADING AND INSTALLING THE APP
......................................................................................................39
12.2.
U
SING THE APPLICATION
.............................................................................................................................41
13. Introduction to AA-Video Console APP version for ANDROID systems ...................................... 41
13.1.
D
OWNLOADING AND INSTALLING THE APP
......................................................................................................41
13.2.
U
SING THE APPLICATION
.............................................................................................................................43
14. APPENDIXES............................................................................................................................................ 45
14.1.
A
PPENDIX
1:
O
THER EXAMPLES OF
M
ULTICAST
A
UDIO
S
TREAMING APPLICATIONS
.............................................45
14.2.
A
PPENDIX
2:
S
CENARIO OF A COMPLETE SYSTEM WITH
T
EMA
ADAM
MANAGEMENT SOFTWARE
..........................47
14.3.
A
PPENDIX
3:
U
SE OF THE
AUDACITY
SOFTWARE FOR AUDIO FILES RECORDING
...............................................50
14.4.
A
PPENDIX
4:
C
ABLING OF A
UTP
RJ45
NETWORK CABLE ACCORDING TO THE STANDARD
EIA568B.....................51
INDE
X
PAGE

TEMA TELECOMUNICAZIONI
AD638 VoIP SIP Speaker 2x20W PoE
MAS-AD638-REV00EN Page 5 of 52
1. PRESENTATION
AD638 allows to realize Paging Amplification Audio Sound Systems in a standard LAN network completely
integrating with IP-PBX SIP in order to be able to play announcements from any telephone in the internal network
and any technologies: analog, SIP, Smartphones and Softphones.
Access can be authorized by Password with code to be typed before starting the announcement. Two internal
relays can be programmed to be automatically activated when it is called or to be controlled from the phone via
LAN that originated the call to the AD638 speaker, eg. to report the event to any auxiliary devices connected
downstream.
The system programming is done remotely via LAN thanks to the integrated Web server. AD638 incorporates an
efficient Class-D 10W (2x5W) amplifier.
2nd SIP Account – Night Ringer. AD638 can be registered on the PBX with a second telephone number, different
from the one used for ads and inserted in the night ring group. To the arrival of an incoming call, the system plays a
sound (user selectable) to all the network speakers. The volume can be adjusted independently of the others
managed audio channels.
Inputs from external contact with a variety of functions, for example: provide to make a SIP call to a
preprogrammed number and inform the operator of the event with an appropriate voice message. The signaling
can be repeated a number of programmable times, the operator can interrupt the sequence with a keyboard code.
Other examples of use will follow in this manual.
Multicast Audio Streaming for music and announcements diffusion. AD638 handles up to 16 multicast channels
in LAN with priority levels to allow the background music broadcasting on loudspeakers network. The generation of
musical programs in streaming audio can be managed from a PC of the LAN/WAN network with special software or
special TEMA Encoder.
Service "SIP Security Info Call" - Emergency SIP Call. By connecting a button or an external contact, AD638 can
call a phone number programmed to alert the event with a specific warning message. It is a security service for
emergencies or simple request for help and information, and allows a one-way phone call.
Total remote management via LAN, integrated Web Server. Programming, configuration, loading and listening to
audio files, firmware release update, audio volume adjustment, backup and restore the configuration, device
reboot.
Possibility to connect one or more external passive loudspeakers on the 2nd amplifier to expand audio coverage
of the served area. High output power of 40W (2x20W) when powered by an external power supply, automatic
adjustment of power with 10W limitation in case of power supply by LAN cable via PoE only.
Tested with most popular P X brands:
SIEMENS - AVAYA - ALCATEL – PANASONIC – SAMSUNG - NEC - 3CX
LG - WILDIX - AASTRA - ASCOM - NITSUKO - SELTA – PHILIPS
MITEL – ASTERISK-BASED SYSTEMS

TEMA TELECOMUNICAZIONI
AD638 VoIP SIP Speaker 2x20W PoE
MAS-AD638-REV00EN Page 6 of 52
VoIP SIP Amplifiers-Speakers and accessories of the AD600 series
AD610
2X2W PoE IP-SIP Amplifier Module,
External Amplifier Adapter with Sound Isolation
Transformer. irectly pilot external power amplifiers
or 8 Ohm external passive speakers.
AD611
IP-
SIP PoE 10W Amplifier Module
(2X5W). irectly pilot 8 Ohm external passive
speakers.
AD633
IP-
SIP speaker 12W PoE ceiling mount
version. Same design
AD333/12TP
passive 12W-
8Ohm speaker with transformer.
AD63
IP-SIP 12W PoE Speaker, wall mounting.
Same design
AD33 /06TP
passive speaker 6W-
8Ohm with transformer.
AD612
IP-
SIP PoE 40W (2x20W) Amplifier Module
when powered with an external power supply.
irectly pilot 8 Ohm external passive speakers.
AA
-
699/xxx
Flash lights with Xeon
lamp or high brightness LE s. Ideal to be
controlled by the relay of the IP-SIP speakers
of the A 630 series or by the IP-SIP amplifier
A 610, A 611, A 612 modules, with a call in
progress add a light signal to the acoustic
signal.
AD61 /S
Audio Encoder Module from
analog to digital on LAN Network in
Multicast/Broadcast Channels.
AD630
IP-
SIP PoE 25W Horn Speaker with 40W
internal amplifier (2x20W) IP65 protection. Same
design
AD330/30T
passive horn 30W-8Ohm
with
transformer.
AD633C
IP-SIP 12W PoE Speaker ceiling mount
version with IP54 flameproof cover. Same design
AD333/12XTP
passive 12W-8Ohm speaker with
transformer.
AD634
IP-SIP 2x20W PoE IP65 Speaker in vandal-
proof aluminum. Same design
AD334/20TP
passive 20W-8Ohm speaker with transformer.
ADAM
Audio omain & Access Management
Management software and microphone
console from 3 to 256 zones
AD696/AA
External Microphone Base
with "Talk" button specific for PC with A AM
software
AA
-
39DL
Plug Power Supply 220Vac/12Vdc-1,0A.
AA
-
39D1A
IN Power Supply 220Vac/15Vdc-1,0A.
A
A
-
39P4
PoE injector 230Vac/48Vdc 0,5A.
AA
-
39E3
IN Power Supply 220Vac/24Vdc-1,5A
AA
-
39
E6V
IN Power Supply 220Vac/24Vdc-2,5A.
AD639
IP-SIP 2x20W PoE IP56 Speaker. Same
design
AD339
passive speaker 15W-8Ohm.
AD639R
Telephone call repeater and IP SIP
Announcer/Alarm 30W , in
tegrated PoE power
supply 802.af, IP56.
AD696/BM
External microphone base
with "Talk" button and 7 selectable Chime for
A 615/S RJ45 plug. Version
AD696/B
without chime.
AD696/AC
Handset microphone and
earphone with PC-specific 4-pole jack with
A AM software
AD630/SMS
Special device for security
and Man own applications, IP system in LAN
network with SMS activation
AD638
IP-SIP 2x20W PoE IP65 speaker two-way
low-medium and high. Same design
AD338
passive
speaker 30W-8Ohm.

TEMA TELECOMUNICAZIONI
AD638 VoIP SIP Speaker 2x20W PoE
MAS-AD638-REV00EN Page 7 of 52
AD320/30
PA 100V audio li
ne transformer
30W, constant voltage, high efficiency toroidal type
with low magnetic flux leakage.
AD32
Isolation transformer, balanced, mixer,
attenuator, audio signal filter, low impedance
output. Ideal for decoupling devices of audio
sources to other amplifiers to eliminate noises.
AD301R
30W analog amplifier, 2
channels, Volume-High-Low +/-
12dB
controls
AA
-
36
Protected Power Relay Actuator
250Vac/16A/4KVA, command in AC/ C 12V/24V, 1
contact, Led, contacts protected by electric ar
cs.
Ideal for driving loads up to 4.000W.
AD330/xx
Are available Speakers of different
power, Horns and Loudspeakers for flush and
ceiling mount, indoor and outdoor, IP54-65.
AA
-
39D2
IN Power Supply 220Vac/15Vdc-2A-30W
ANALOG COMPONENTS
•
INTEGRA LE WITH ANY KIND OF IP
-
P X AND SOFTCLIENT
• INTEGRATION WITH EVERY SAFETY SYSTEM
• LAUNCH OF ADS AND COMMANDS VIA GSM/UMTS
• ACTIVATION VIA SMS
• 2-WAY COMMUNICATIONS - INTEGRATED MICROPHONE
• PROTECTION FROM IP54 TO IP67
• VANDALPROOF VERSIONS FOR INDUSTRIAL ENVIRONMENTS
• CONTINUED UPDATES AND INNOVATIONS
• CURRENT ADVANCED TECHNOLOGY
Unique features of the "SipComStage" AD600 Audio over IP line
• SCALA ILITY
• RELIA ILITY
• FLEXI ILITY
• EASY TO USE
• EASY TO MANAGE
• REMOTE CONTROL
• HIGH SOUND QUALITY
• INTEGRATED POE POWER SUPPLY
• TERMINAL INTERCHANGEA ILITY
• UNIQUE AND EXCLUSIVE PERFORMANCES
• EASY SOFTWARE UPGRADE
• CE CERTIFICATION
• LOW COSTS
Tested with the most popular P X brands:
SIEMENS - AVAYA - ALCATEL - PANASONIC - SAMSUNG - NEC - 3CX
LG - WILDIX - AASTRA - ASCOM - NITSUKO - SELTA - PHILIPS
ASTERISK BASED SYSTEMS
MADE
IN
ITALY
: all the products are designed an
d manufactured in Italy by TEMA which guarantees
their support and technical assistance over time with a 24 months warranty.

TEMA TELECOMUNICAZIONI
AD638 VoIP SIP Speaker 2x20W PoE
MAS-AD638-REV00EN Page 8 of 52
2. FEATURES
•
IP 2x20W PoE Speaker for indoor / outdoor installation, IP65 protection degree
•
Audio power output 40W (2x20W) with external power supply, 10W (2x5W) with PoE power supply
•
Possibility to register a second SIP account for the "Night Ringer" feature
•
16 RX Multicast Channels for Music/Ads/Messages diffusion with 16 priority levels
•
2 remote controlled relays via LAN
•
1 multifunction input from external contact (free from voltage)
•
Possibility of playing a pre-recorded announcement, associated with the available input, or up to 6
announcements by making a call and sending the respective code via telephone
•
• Notification service with dedicated messages following external event
•
1 button inputs for direct call to SIP numbers differentiated by communication/alert
•
“SIP Security Info Call” warning/emergency telephone call, sending of pre-recorded messages on
loudspeakers and on the called
•
"Push to Talk" function to control the direction of communication from an external button (Not included)
•
Independent adjustment of audio volumes: communications, multicast, night ringtone, alert tones
•
SD memory card with audio files from 60sec. customizable by the user (opt. up to 960min. - 16h audio)
•
Great versatility with ease of use and programming
•
VoIP connection with standard SIP Proxy Server protocol
•
Compatibility with all IP-PBX of the most prestigious brands
•
P2P (Peer to Peer) for operation also without IP-PBX
•
Power supply via PoE (Power over Ethernet) with a single UTP cable or external power supply, also at the
same time
•
Free APP developed for smartphones/tablets with iOS and Android operating systems
•
AA-Videoconsole software for Windows XP/7/10 PC for management of TEMA IP terminals included
•
Programming via dedicated Web Interface with password protection
•
Possibility of software / firmware update via LAN
•
Integration with the local LAN, 100BaseT Ethernet LAN port with RJ45 connector
•
Dimensions 190 x 195 x 290mm
•
Montaggio a parete, soffitto, in interno/esterno, uffici, magazzini, capannoni, ecc..
•
Possibility of receiving and sending MULTICAST RTP audio streaming, for paging audio announcements, up
to 16 priority levels (in reception) and with different volumes for each channel
•
Audio streaming with high quality codecs
•
Possibility of diffusing pre-recorded announcements at pre-established times (up to 5 for each day of the
week)
•
Possibility of diffusing a pre-recorded daily announcement, at a set time or manually controlled, with
programmable interval and repetitions
3. PACKING LIST
The systems are supplied with the parts included in the following list:
•
One speaker device code AD638
•
A printed system documentation, installation, programming, use manual
•
A CD-ROM with complete documentation

TEMA TELECOMUNICAZIONI
AD638 VoIP SIP Speaker 2x20W PoE
MAS-AD638-REV00EN Page 9 of 52
4. TECHNICAL SPECIFICATIONS
LAN
TCP/IP Network 10/100BaseTx
Protocols
SIP 2.0, RFC 3261
RTP Multicast audio Streaming
G711µ, G711a, G722, L16 from
16
to
44 kHz
Connection
SIP Server (IP
-
PBX) o
r
P2P (Pe
er To Peer)
Power Supply
PoE, PoE Injector and/or
external
Ac/Dc
power supply
PoE
IEEE802.3af class
0 12,95W
External Power Supply
(Op
t
.)
230Vac / 12Vdc
-
1A, 24Vdc
-
2A
Technology
I
MX25 400MHz
Microprocessor
Memory
256MB Ram, Micro
-
SD Flash 2GB
Programming
practical Web interface and password
APP
for Smartphones
iOS, Android
Messagges/S
o
unds
prerecorded in the internal SD memory card
Audio File Format
Windows .w
av
–
8K
–
16 bit
Duration
6
0
sec each
. Standard (Option up to 960 min.
16H audio)
Larghezza di banda
50Hz
–
20.000
Hz
Power
Class
-
D
Amplifier
10W (PoE), 40W (
external power supply
)
Sound pressure (SPL 1W
-
1mt)
93dB A
Dispersion angle
170° x 170° @ 2K
Hz
Audio communication
Unidirectional / Bidirectio
nal / Push to Talk
Internal Microphone
Omni
-
directional electret 30Hz
-
18KHz
A
dditional speaker output
1 output for external speaker, passive
,
impedance 8 Ohm
A
utomatic
c
heck mode
Through self audio feed
back
Inputs from buttons
or external contacts
1
for
button + 1 for warning
/alarm
Integrated relays
,
contacts capacity
2
,
Max 30Vdc 1,5
A
Signalings
Active call Led, call tone,
chime
Installa
t
ion
Wall mount
Housing M
aterial
ABS
Degre
e of protection, Relative humidity
IP65, weather resistant, Up to 100%
Storage/operating temperature
From
-
20° to +65°C
-
From
-
20° to +55°C
Dimensions,
Weight
190 x 195 x 290mm
-
3,3
Kg
W
arrant
y
2
years, possibility of extension (
O
ption)
Compatibility
CE, ROHS

TEMA TELECOMUNICAZIONI
AD638 VoIP SIP Speaker 2x20W PoE
MAS-AD638-REV00EN Page 10 of 52
5. OPERATION
In stand-by and correctly configured, the system waits for incoming calls.
The device allows also the “streaming” Multicast sound diffusion. In this case the RTP audio diffused in LAN will be
played amplified by AD638. Differing from the announce mode on direct call, with multicast mode, more devices
can diffuse the same message at the same time, useful for general pre-recorded ads or for music sound diffusion.
The operator who want to make an announcement on the device will make a call, from any extension of the PBX, to
the number to which the device is registered or to its IP address in the case of Peer-to-Peer connection.
It is always monitored the change status of an alarm input to which it is possible to associate a number to call and a
message to be played to the called party answer. It is possible to make common adjustment of the level output of
the speakers to better suit the acoustic characteristics of the served area.
The system can activate a relay contact for signaling to external devices.
5.1. Device connection diagrams
Access
Point
ZON
E
3
A 638 SIP with
additional A 338 passive
speaker for doubling power
and directionality.
ZONE
2
A 638 SIP with
other passive loudspeakers
on a 100V line made by
adding an A 320 / 30
transformer
ZONE
1
A 638 SIP with
relay remote control and
call button
“Push To Talk”
call button
Application with
IP
-
PBX o
r
Peer to Peer
Each A 638 can be reached from SIP phones, Smart-phone
and other registered terminals in the IP-PBX that can launch
ads. The integrated relay can be operated from the SIP phone
that originated the call. With a Network PC with installed the
free software TEMA "Videoconsole" it is possible to make
calls to IP speakers. If the free software "VLC" is also
installed, it will possible to send on Streaming Audio speakers
multicast channels, interrupted by ads as background music.
In each A 600 series speaker, it is possible to independently
adjust the audio volume reproduced via LAN thanks to the
integrated web server..
IP SIP
Phone
Network PC with A AM software
Audio omain & Access Management
and microphone base for complete
system management
Smartphone with
TEMA APP
IP PBX
A 638B
A 338/40B
Passive
Speaker 8 Ohm
A 638W
A 638W
Soft
Client
Flash
PoE
LAN Switch
IP SIP
Phone
ZONE
1
ZONE
2
ZON
E
3
ZON
E
4
P2P (Peer to P
e
er)
Application
The application does not require the presence of an IP-PBX
and the presence of the 220V network on site (Within 100
meters from the switch). Each A 638 SIP can be reached by
SIP phones that can launch an announcement. The speaker
power supply travels on the same UTP cable from the PoE
switch. Thanks to the integrated microphone it is possible to
hear the sound of the area of the respective speaker. The 2
integrated relays can be activated by the IP phone that
originated the call to operate additional services.
UTP cat5/6
A 638W
A 638W
A 638B
A 638B

TEMA TELECOMUNICAZIONI
AD638 VoIP SIP Speaker 2x20W PoE
MAS-AD638-REV00EN Page 11 of 52
6. OPERATING MODES
6.1. Calls to devices
Call from the PBX phones, of any technology, to the AD638 system allows to make announcements to the network
speaker. However, it is a normal telephone call, typically unidirectional although AD638 makes possible to hear the
sound present in its vicinity, being equipped with an internal microphone. Calling the extension number connected
to the systems, they will answer after a set time. It is also possible to have an appropriate code to protect the
function from unauthorized access. Hang up to end the announcement. Any background music will be automatically
restored after some seconds.
6.2. RELAY function
The relays are typically used to signal to any auxiliary external devices that the announce is played, automatic
activation call per call. If not used for the function described above it is available and can be controlled with an
appropriate code from the caller's telephone.
6.3. Alarm Input IN1: calls generated for acquisition of external contacts for special signalings
Are the calls that the system generates on the VoIP line, after the activation of the IN1 input, to a number (or IP
address) set for the warning. When the operator answers, a pre-recorded message is sent to him. It is possible to
associate a phone number or an IP address that will be called when the input is activated. It is possible to establish
the activation condition of the same. It is the closure of the external contact that triggers the signaling sequence but
it is also possible to invert this logic, so that the triggering of the signaling can occur following the opening of the
contact connected to the input. AD638 continuously monitors the status of the contact in the event of the condition
of the activation stored on non-volatile memory card. As soon as possible it will begin to call the person who will
manage the situation found at the telephone number programmed reproducing the message associated with the
event. It is also possible to choose to play on a local speaker and on any connected audio output a pre-recorded
message, which will be played prior to the call to alert the present persons in the area served by the system
detected event. It is possible to define an acquisition/silencing code of alarm signaling that the called must type to
inform the device of the alarm acknowledgment. If the called number is busy or does not reply, or in any other case
where AD638 does not receive the capture/acknowledgment code, at the end of each call attempt return in standby
and prepares itself for a new alarm notification
When the systems receive the correct acquisition/acknowledgment code related to the alarm in progress, the alter
signaling will stop and will not be carried out further alarm notification calls. In order to be ready again, it is
necessary that the condition which had triggered the previous notification returns in standby. Only at the
occurrence of a new activation of the contact condition the calls cycle with the alert notification will start again. In
practice: if a connected contact is closed and it is detected its activation, AD638 starts to make warning calls.
In the event that the person called by the system answers and successfully enter the acknowledge code, the alert
calls will be terminated. If the contact that had triggered the alert, however, remained closed (this obviously
depends by the external device that controls the contact) will NOT be triggered another warning cycle! To have new
alerts for this contact, it is necessary that come back in standby before (reopening) and then to its new next
possible closure will be detected from AD638 system with new telephone alerts.

TEMA TELECOMUNICAZIONI
AD638 VoIP SIP Speaker 2x20W PoE
MAS-AD638-REV00EN Page 12 of 52
6.4. Streaming Audio Multicast
In a LAN network, the Multicast term indicates the possibility to distribute an information like data, audio or video, to
a group of IP terminals of the Ethernet network. For Multicast are used class D IP addresses and they range from
224.x.x.x to 239.x.x.x. In our case the AD638 system is able to receive audio in Multicast into the specific IP
channel and play it amplified. The audio can be generated from a PC software application (for example VLC) or by
a IP SIP phone. The received audio stream is played without the intervention of any operator, this function is useful
for playing back voice messages and information or emergency announcements (also called "Paging" mode).
Obviously the Multicast audio streaming is unidirectional, the audio stream is sent from source to destination, but
not vice-versa. The audio stream can be sent simultaneously to multiple terminals (same IP Multicast), or only to
distinct terminals (each provided with its own IP address). It is possible to program up to 16 audio receive
addresses, each with its own priority and its playback volume, so that the same terminal, if it is already playing
audio (eg music) can be interrupted by a higher priority stream (for example an announcement) and with a different
volume (typically an announcement must be played at a higher volume than background music). The audio
supported by this mode is in the G.711 format (aLaw or μLaw), G722 or linear high quality 16 bit (proprietary
format, diffused through the AD615 device, another AA-540 and finally from the ADAM Tema software).
Example 1
In a plant, there are two systems, connected to the same network switch. From a suitable phone, it
is possible to make a voice announcement via multicast address 239.255.12.42:
Both systems will play the announcement audio message. Many more devices than those given in the example can
be connected, since there are no limits.
Example 2
In the plant there are two systems with different Multicast addresses.
The phone, selecting to send the multicast voice to one or other address of the terminal, will decide which device
must play the streaming message.
7. COMMANDS AND CODES
During the announcement will be possible to send the commands described here (which will be these by default):
DTMF
Command Function Description
#1 - #2 Activate the relay contact
1 or 2
Used to manually activate the relays if not
programmed to be automatically activated per
announcement.
#5 Extension of announcement
time
AD638 alert the operator with some tones 30 seconds
before the expiration of the time for the
announcement. Having to extend the announcement
over the set time it is possible to recharge original time
to continue the conversation (with this code).
AD638 n. 2 Multicast
address
239.255.12.42
Extension Phone
designed for
Multicast
LAN Switch
AD638 n. 1 Multicast
address
239.255.12.42
AD638 n. 2 Multicast
address
239.255.12.41
Extension Phone
designed for
Multicast
LAN Switch
AD638 n. 1 Multicast
address
239.255.12.42

TEMA TELECOMUNICAZIONI
AD638 VoIP SIP Speaker 2x20W PoE
MAS-AD638-REV00EN Page 13 of 52
8. INSTALLATION OF THE DEVICE
8.1. Mounting and positioning of the AD638 system
The IP Speaker must be fixed to a stable surface suitable for supporting its weight, also considering the fact that
hanging to the side or below the fixing surface, the force that the supporting material must oppose is greater than
the nominal weight of the single unit to support.
The AD638 wall mounting bar has holes for wall mounting. The position is adjustable both horizontally and
vertically.
8.2. Accesso to the rear connectors
Once the AD638 speaker is fixed, access to the rear compartment where it is possible to connect the UTP LAN
cable category 5 or 6 and any other service cables. The speaker has incorporated PoE power supply, so it picks up
the power supply directly from the LAN cable if it comes from a PoE switch or an injector interposed in the network.
In the absence of PoE power supply, an external 230Vac power supply is required, available in the Tema catalog
with code AA-39E3 24Vcc-1.5A or the PoE injector code AA-39P4.
Woofer
speaker for
bass-mids
Call in progress
Led indicator
Micro
phone
•
Tweeter
speaker for
high-pitched
sounds
Connection
group

TEMA TELECOMUNICAZIONI
AD638 VoIP SIP Speaker 2x20W PoE
MAS-AD638-REV00EN Page 14 of 52
8.3. Connecting the AD638 speaker
Inside AD638 there is an electronic module for managing the communication functions on the VoIP network and for
amplifying the audio signal. The connection of the signal cables from the field must be carried out by qualified
technical personnel, and strictly comply with the voltage and current values for the power supplies and other parts
of the system. Follow the instructions given here for the correct electrical connection of the system.
Terminal block 1 (2 poles, external power supply)
A
Terminal to power the system from external power supply, irrelevant polarity
C
Terminal to power the system from external power supply, irrelevant polarity
Note: The system tolerates the presence of both power supplies, both coming from a PoE switch and from
an external power supply connected to terminal 1 group, simultaneously.
LE Power
A
-
C
External Power Supply
12-24Vdc / 12-18Vac
(
i
ndependent polarity
)
1 Rel
ay
n.1 NC
2 Relay n.1 NO
3 Relay n.1 CC
4 +Vout protected
5 - Vout (Ground)
6 IN1
Alarm input
7 GN
8 P1 VoIP call
9 Relay n.2 NO
10 Relay n.2 CC
11 SPK 1 - External speaker
12 SPK 1 + External speaker
LAN
cable input
UTP cat. 5/6 - PoE
Terminal
block 1
Terminal
block 2
Terminal
block 3
1
2
3
4
6
7
8
9
10
11
12
A
C
It is possible to supply with a DC voltage in the range from 12Vdc to 24Vdc (Max 26Vdc) or with an
AC voltage of 12Vac to a maximum of 18Vac. The required current is 2A.
Attention: exceeding the maximum voltage limits will cause permanent damage to the device!

TEMA TELECOMUNICAZIONI
AD638 VoIP SIP Speaker 2x20W PoE
MAS-AD638-REV00EN Page 15 of 52
Terminal block 2 (5 poles, Relay 1 and protected output power supply)
1
K1 relay terminal block – NC contact, normaly closed
2
K1 relay terminal block – NO contact, normally opened
3
K1 relay terminal block – CC contact, central contact (max contacts load 30V 1.5A)
4 +Vout
Terminal from which it is possible to take power supply
, POSITIVE
5 GND
Terminal from which it is possible to take power supply
, NEGATIVE
LAN RJ45 Port
AD638 requires a LAN cable to connect to the network. If the port cable has also PoE, it will not be necessary to
supply the module with other power sources (up to max 10W powers). For higher powers will be necessary to
supply the module with other power source of 24 Vdc 2A or max 18Vac 2.5A. At the end of the manual in appendix
2 the correct wiring of the LAN cable to the RJ45 connector is shown.
Terminal block 3 (7 poles, Relay 2, alarm input, P1 input, 2nd passive speaker output)
6 ING1
Terminal for detecting the alarm contact
7 GND
Terminal related to the system power supply negative, for the alarm contact
8 P1
Connect here the clean contact of the button for the VoIP call service, the second terminal of the
button must be connected to terminal 7 GND
9 K2 NO
K2 relay terminal block – NO contact, normally opened
10 K2 CC
K2 relay terminal block – CC contact, central contact (max contacts load 30V 1.5A)
11 SP1-
Output terminal 1st Class-D amplifier, for connecting a speaker, negative front
12 SP1+
Output terminal 1st Class-D amplifier, for connecting a speaker, positive front
At the "+Vout" output there is a + 12Vdc voltage when the device is powered via PoE, otherwise,
at
this output the voltage will be the same as at the terminals A-C. The use of "+Vout" is permitted as
long as it is not exceeded a maximum 200mA current consumption and the load has a protection on
the input current. Improper use of this output will permanently damage the unit.
Devices powered via PoE (Power over Ethernet) may only be conn
ected with cables coming from
inside the building, they are not allowed connections to LAN cables coming from outside the
building.
To terminals
6 (ING1)
and
7 (GND)
must only be connected a relay contact or a button free from any
voltage to prevent permanent damage to the device.
To terminals
8 (P1)
and
7 (GN
D)
must only be connected a relay contact or a button free from any
voltage to prevent permanent damage to the device.

TEMA TELECOMUNICAZIONI
AD638 VoIP SIP Speaker 2x20W PoE
MAS-AD638-REV00EN Page 16 of 52
8.4. Correct connection of an additional passive speaker
The power amplified SP1 is an output where it is possible to connect an external additional speaker passive paying
attention to its polarity but especially to the load impedance which cannot be lower than 8 Ohm.
Furthermore, it must be respected the maximum output power from the amplifiers using adequate power speakers.
In the simplest case just connect an 8 ohm speaker of at least 20W power or higher. Use cables with different
colors, section of at least 1.5 mm2 and limit the distance from the amplifier to no more than 30m.
Below are some examples of mixed combinations, to serve a wider area but with distributed power.
Correspondence cables AWG / mm
2
AWG20 > 0,518 mm
2
resistance 33,31 Ohm/Km
AWG19 > 0,653 mm
2
resistance 26,42 Ohm/Km
AWG18 > 0,823 mm
2
resistance 20,95 Ohm/Km
AWG17 > 1,04 mm
2
resistance 16,61 Ohm/Km
AWG16 > 1,31 mm
2
resistance 13,17 Ohm/Km
AWG15 > 1,65 mm
2
resistance 10,45 Ohm/Km
AWG14 > 2,08 mm
2
resistance 8,286 Ohm/Km
AWG13 > 2,62 mm
2
resistance 6,571 Ohm/Km
AWG12 > 3,31 mm
2
resistance 5,211 Ohm/Km
AWG11 > 4,17 mm
2
resistance 4,132 Ohm/Km
AWG10 > 5,26 mm
2
resistance 3,277 Ohm/Km
SP +
SP
-
4 Ohm
10W
4 Ohm
10W
SP +
SP
-
8 Ohm
5W
8 Ohm
5W
8 Ohm
5W
8 Ohm
5W
AD338B
8 Ohm
40W
SP1
+
(positive
)
SP1
–
(negative
)
Minimum cable section 2x1,6
mm
2
(AWG15), ideal 2x2,5 mm
2
(AWG13), 2 colors or polarized
strip, maximum recommended
distance 30 meters
+
(positive
)
–
(negative
)

TEMA TELECOMUNICAZIONI
AD638 VoIP SIP Speaker 2x20W PoE
MAS-AD638-REV00EN Page 17 of 52
8.5. 100V audio line for additional speakers away from AD638 IP Speaker
For special applications it is possible to generate from AD638 an audio line at a constant voltage of 100V of max
20W power using a Tema AD320/30 transformer to connect on the SP1 power output. In this way it is possible to
install several other additional speakers (with internal transformer suitable for 100V line and selectable power) even
at distances up to 200 meters from AD638. The total sum of the power the installed speakers must not exceed the
maximum power of 20W.
Some examples of speakers available on Tema catalog (not amplified, passive models)
AD330/15T Horn Speaker 15W / 8Ohm with transf. 100V, sockets 15/7.5/3.7/1.9 W
response 300Hz - 7KHz, Dim. Diam. 210 x 240 mm
AD330/25T Horn Speaker 25W / 8Ohm with transf. 100V, sockets 25/12.5/6.25/3.12 W
response 300Hz - 7KHz, Dim. Diam. 240 x 290 mm
AD335/06TP Wall Speaker 6W / 8Ohm Transf. 100V sockets 6/3/1.5 W
response 180Hz - 16KHz, Dim. 218 x 216 x 120 mm
AD334/20TP Vandal proof Projector 20W with transf. 100V, outdoor, sockets 20/10/5 W, IP65
response 150Hz - 15KHz, Dim. Diam. 180 x 145 mm, weight 2.4kg, grey color
AD337/06TP Oval wall speaker 6W / 8Ohm with transf. 100V sockets 6/3/1.5W
response 180Hz - 10KHz, Dim. 258 x 169 x 72 mm, 0,8Kg
AD333/12TP Round speaker wall/ceiling flush mounting, 12W with Transformer 12/6/3 W
response 80Hz - 15KHz, Dim. Diam. 200 x 62 mm (Hole 160-165mm)
D333/12XTP Round speaker ceiling flush mounting, 12W with Transf. 12/6/3 W
Band 80Hz - 20KHz, Dim. Diam. 220 x 130 mm (Hole 200-205mm)
with flameproof cover AD333/12YC
The speakers l
isted abo
ve are not produced by
TEMA, but a selection of the best third
-
parties
quality producers that are best suited to our production amplifiers and PA analog speaker
systems and IP VoIP SIP for audio LAN. The components offered however fall into the corporate
policies in terms of warranty and technical support.
100
V line
for additiona
l speakers
AD320/30
Transformer for
100V-30W line
SP1 +
SP1
-
AD638
B
2x20W SIP Speaker
Minimum cable section
2 x 0,75mmq (AWG18)
2 colors or polarized strip, maximum
recommended distance 200 meters
8 Ohm
1…5W
8 Ohm
1…5W
8 Ohm
1…5W
8 Ohm
1…5W
+
-
LAN

TEMA TELECOMUNICAZIONI
AD638 VoIP SIP Speaker 2x20W PoE
MAS-AD638-REV00EN Page 18 of 52
9. PROGRAMMING
9.1. Preparation for the system parameters programming
Programming is done via the WEB interface. To gain access, simply connect an Ethernet cable from a PC or from a
switch to the LAN port of AD638.
The default IP address of AD638 is "192.168.0.10".
Remember that in order to successfully connect to the web interface of AD638, it is necessary that, in the IP
addresses configuration of your PC, is present the subnet 192.168.0.x, where "x" is any number between 1 and
254 and different from 10. See below how to configure your PC to reach the correct subnet. The shown procedure
applies to Windows® operating systems.
Open the Windows Control Panel and set the field "View by": "Category" "Large Icons" or "Small Icons".
Choose "Network and Sharing Center" as shown in the first figure, detect your LAN connection, choosing the one
referring to the network card that you are using to connect with AD638.

TEMA TELECOMUNICAZIONI
AD638 VoIP SIP Speaker 2x20W PoE
MAS-AD638-REV00EN Page 19 of 52
Once the correct connection is identified, click on it and it will appear the window where it is necessary to click on
the "Properties" button. It will then open the window where must be selected "Internet Protocol Version 4
(TCP/IPv4)" and then click the Properties button again. See the following figures:
If the PC is already on subnet 192.168.0.x with a mask 255.255.255.0, ignore the following steps. Otherwise,
proceed as follows. (The address of the PC configuration should not be 192.168.0.10). Remember the current
TCP/IP configuration of your computer for any subsequent restore of the correct parameters. Click "Use the
following IP address" and type in the appropriate field the following IP address: 192.168.0.11 (instead of "11" used
in the example it is possible to enter any number between 1 and 254, but excluding the 10 which is the default
address of the system to be programmed). In the "Subnet Mask" enter the netmask 255.255.255.0. Click OK to
confirm the changes. The PC is now ready to configure the door phone. Remember at the end of programming to
restore the network configuration of the PC to its original state if necessary.
Once the IP address of your PC is successfully configured, it is possible to reach the Web interface to configure
AD638 at the address 192.168.0.10 .

TEMA TELECOMUNICAZIONI
AD638 VoIP SIP Speaker 2x20W PoE
MAS-AD638-REV00EN Page 20 of 52
9.2. Access to programming
To program the device, it is sufficient to use a standard browser such as Explorer, Firefox, Chrome or others. The
default address of the device is 192.168.0.10 with a mask of 255.255.255.0, and the user/password with which to
connect are master/master. Make sure to have access to this network segment from your computer. Once logged
in, it is possbile to change the administrative password for the maximum safety of your device. Once logged in, it is
possbile to change the administrative password for the maximum safety of your device.
The use is very simple and intuitive, it is always visible on the left the menu for selecting the functions to be
programmed, while on the right is shown the configuration window that is currently active. Any change will be
confirmed by pressing the "Apply" or "Save" buttons. Closing the browser or changing the page without selecting
those buttons will make lost any change
.
Any changes do not require restarting the device (except the change of IP address, and the software update).
As specified above, for each change on any page, it is NEEDED at the end to immediately press the
"Apply" or "Save" button otherwise the changes will be lost. It is also advisable, before making
changes in the fields, to always refresh the Web page with the F5 browser function key or the
corresponding icon.
Table of contents
Other Tema Telecomunicazioni Speakers manuals

Tema Telecomunicazioni
Tema Telecomunicazioni AD633 User manual

Tema Telecomunicazioni
Tema Telecomunicazioni AD635 User manual

Tema Telecomunicazioni
Tema Telecomunicazioni AD338/30 User manual

Tema Telecomunicazioni
Tema Telecomunicazioni AD630 User manual

Tema Telecomunicazioni
Tema Telecomunicazioni AD633C User manual

Tema Telecomunicazioni
Tema Telecomunicazioni AD630S User manual

Tema Telecomunicazioni
Tema Telecomunicazioni AD634 User manual

Tema Telecomunicazioni
Tema Telecomunicazioni AD335/06TP User manual

Tema Telecomunicazioni
Tema Telecomunicazioni AD330/30T User manual

Tema Telecomunicazioni
Tema Telecomunicazioni AD630S Owner's manual