manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. TESTO
  6. •
  7. Measuring Instrument
  8. •
  9. TESTO 810 How to use

TESTO 810 How to use

Other manuals for 810

3

Other TESTO Measuring Instrument manuals

TESTO 550 User manual

TESTO

TESTO 550 User manual

TESTO 417 User manual

TESTO

TESTO 417 User manual

TESTO 435 User manual

TESTO

TESTO 435 User manual

TESTO 330 User manual

TESTO

TESTO 330 User manual

TESTO 445 User manual

TESTO

TESTO 445 User manual

TESTO 316-1 User manual

TESTO

TESTO 316-1 User manual

TESTO 545 User manual

TESTO

TESTO 545 User manual

TESTO 0560 4160 User manual

TESTO

TESTO 0560 4160 User manual

TESTO Saveris Series Training manual

TESTO

TESTO Saveris Series Training manual

TESTO 350 Maritime V2 User manual

TESTO

TESTO 350 Maritime V2 User manual

TESTO 0590 0003 User manual

TESTO

TESTO 0590 0003 User manual

TESTO 330 Technical manual

TESTO

TESTO 330 Technical manual

TESTO Sensor LD pro User manual

TESTO

TESTO Sensor LD pro User manual

TESTO 635 How to use

TESTO

TESTO 635 How to use

TESTO Saveris User manual

TESTO

TESTO Saveris User manual

TESTO 110 User manual

TESTO

TESTO 110 User manual

TESTO 512 User manual

TESTO

TESTO 512 User manual

TESTO 6681 Profibus User manual

TESTO

TESTO 6681 Profibus User manual

TESTO 174T User manual

TESTO

TESTO 174T User manual

TESTO 616 User manual

TESTO

TESTO 616 User manual

TESTO 549 User manual

TESTO

TESTO 549 User manual

TESTO 770 User manual

TESTO

TESTO 770 User manual

TESTO 240 User manual

TESTO

TESTO 240 User manual

TESTO 6440 User manual

TESTO

TESTO 6440 User manual

Popular Measuring Instrument manuals by other brands

Suaoki D40 user manual

Suaoki

Suaoki D40 user manual

Elster BK-G1.6 operating instructions

Elster

Elster BK-G1.6 operating instructions

Endress+Hauser Deltabar FMD71 technical information

Endress+Hauser

Endress+Hauser Deltabar FMD71 technical information

Duratool D03128 manual

Duratool

Duratool D03128 manual

Vega VEGAPULS 65 Quick setup guide

Vega

Vega VEGAPULS 65 Quick setup guide

Tonghui TH2618B Operation manual

Tonghui

Tonghui TH2618B Operation manual

Tenmars TM-801 user manual

Tenmars

Tenmars TM-801 user manual

MSR 145 user manual

MSR

MSR 145 user manual

TPS WP-82 manual

TPS

TPS WP-82 manual

PCB Piezotronics 003C30 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 003C30 Installation and operating manual

Tenma 72-10465 manual

Tenma

Tenma 72-10465 manual

Endress+Hauser Proline Promag 50 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 50 Brief operating instructions

Siemens SITRANS F Coriolis FCT030 Function manual

Siemens

Siemens SITRANS F Coriolis FCT030 Function manual

KLINGER CMF V Series instruction manual

KLINGER

KLINGER CMF V Series instruction manual

Keysight M8290A Getting started guide

Keysight

Keysight M8290A Getting started guide

Acterna MS1400 Operation manual

Acterna

Acterna MS1400 Operation manual

R&S ZPH manual

R&S

R&S ZPH manual

Datacolor ColorReader DC10-2 user guide

Datacolor

Datacolor ColorReader DC10-2 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Short manual testo 810 13
Short manual testo 810
Protection cap: Park position
Infrared sensor
Air/temperature sensor
Display
Control keys
Battery compartment (on rear)
Basic settings
Instrument off >press and hold 2s > select with ( ),
confirm with ( ):
Unit of temperature: °C,°F > Differential temperature t:OFF,ON >
Emissonsfaktor: > Auto off-Funktion: OFF,ON
Switching the instrument on
Press .
Switching the display light on (for 10s)
Instrument on > press .
IR measurements
Press and hold .
Select display mode
Instrument on > select with :
Hold: Readings are held > Max: Maximum values > Min: Minimum values
Switching the instrument off:
Instrument on >press and hold 2s.
Safety and the enviroment14
Safety and the environment
About this document
Please read this documentation through carefully and
familiarise yourself with the product before putting it to use.
Keep this document to hand so that you can refer to it when
necessary. Hand this documentation on to any subsequent
users of the product.
Pay particular attention to information emphasised by the
following symbols:
Important.
Avoid personal injury/damage to equipment
Only operate the measuring instrument properly, for its
intended purpose and within the parameters specified in the
technical data. Do not use force.
Never store the product together with solvents, acids or other
aggressive substances.
Only carry out the maintenance and repair work that is
described in the documentation. Follow the prescribed steps
when doing so. Use only OEM spare parts from Testo.
Protecting the environment
Take faulty rechargeable batteries as well as spent batteries to
the collection points provided for them.
Send the product back to Testo at the end of its useful life. We
will ensure that it is disposed of in an environmentally friendly
manner.
Specifications 15
Specifications
Functions and use
The testo 810 is an infrared measuring instrument. It is normally
used to measure surface temperature, e.g. on heaters and
radiators, and to measure the ambient temperature at the same
time.
Technical data
Measurement data
· Sensors:
Infrared sensor,
NTC temperature sensor
· Parameters:
°C, °F
· Measuring ranges:
IR: -30...300 °C, -20...575 °F,
Air probe: -10...50 °C, 14...122 °F
· Resolutions:
0.1 °C, 0.1 °F,
· Accuracies
(Nenntemperatur 22 °C, ±1 Digit):
Infrared: ±2 °C (-30...+100 °C),
±3.6 °F (-22...212 °C),
±2 % of reading (rest of range)
Air probe: ±0.5 °C, ±0.9 °F
· Measuring rate:
0.5 s
· Optics:
6 : 1
Further instrument data
· Protection class: IP40
· Ambient conditions:
-10...50 °C, 14...122 °F
· Storage/transport conditions:
-40...70 °C, -40...158 °F
· Voltage supply:
2x 1.5 V type AAA
· Battery life:
50 h (without display light)
· Dimensions:
119x46x25 mm (inc. protection cap)
· Weight: 90 g (inc. batteries and
protection cap)
Directives, standards and tests
· EC Directive: 89/336/EEC
Warranty
· Duration: 2 years
· Warranty conditions: see guarantee
card
Product description16
Product description
At a glance
Protection cap: Park position
Infrared sensor
Air/temperature sensor
Display
Control keys
Battery compartment (on rear)
First steps
Inserting batteries:
1To open the battery compartment, push the battery cover
down.
2Insert batteries (2x 1.5 V type AAA). Observe the polarity!
3To close the battery compartment, push the battery cover
back on.
Basic settings (configuration mode):
Adjustable functions
· Unit of temperature: °C,°F
· Differential temperature t:OFF,ON
· Emission factor:
· Auto off function: OFF,ON (instrument switches off automatically if no key is
pressed for 10 minutes)
The emission factor has a default setting of 0.95. This is
ideal for the measurement of non-metals (paper, ceramic,
gypsum, wood, paints and varnishes), plastics and
foodstuffs.
Product description 17
Because of their low or non-uniform emission factor, bright
metals and metal oxides are of only limited use for infrared
measurement. Coatings that increase the emission factor,
e.g. paint or emission adhesive (0554 0051) must be
applied to the object being measured.
Emission factors of various materials (typical values):
Material (temperature)
Aluminium, bright rolled (170 °C) 0.04
Cotton (20 °C) 0.77
Concrete (25 °C) 0.93
Ice, smooth (0 °C) 0.97
Iron, emery ground (20 °C) 0.24
Iron with casting skin (100 °C) 0.80
Iron with rolling skin (20 °C) 0.77
Gypsum (20 °C) 0.90
Glass (90 °C) 0.94
Rubber, hard (23 °C) 0.94
Rubber, soft grey (23 °C) 0.89
Wood (70 °C) 0.94
Cork (20 °C) 0.70
Radiator, black anodised (50 °C) 0.98
Copper, slightly tarnished (20 °C) 0.04
Copper, oxidised (130 °C) 0.76
Plastics: PE, PP, PVC (20 °C) 0.94
Brass, oxidised (200 °C) 0.61
Paper (20 °C) 0.97
Porcelain (20 °C) 0.92
Black paint, matt (80 °C) 0.97
Steel, heat-treated surface (200 °C) 0.52
Steel, oxidised (200 °C) 0.79
Clay, burnt (70 °C) 0.91
Transformer paint (70 °C) 0.94
Brick, mortar, plaster (20 °C) 0.93
1When switching the instrument on, press and hold until
and appear on the display (configuration mode).
- The adjustable function is displayed. The current setting
flashes.
2Press ( ) several times until the desired setting flashes.
3Press ( ) to confirm the input.
4Repeat steps 2and 3for all functions.
- The instrument changes to measuring mode.
Using the product18
Using the product
Switching the instrument on:
Press .
- Measuring mode is opened.
Switching the display light on:
The instrument is switched on.
Press .
- The display light goes out automatically if no key is
pressed for 10 seconds.
IR measurements:
Laser radiation! Do not look into the laser beam.
Laser class 2.
To ensure correct readings:
· Keep temperature and humidity sources which may falsify the
measurement (e.g. hands) away from the sensor.
· Keep the lens clean and do not measure with foggy lenses.
· Keep the measuring range (the range between the instrument and the
object being measured) and the surface of the object free of obstacles.
There must be no particles of dust or dirt, no humidity (rain, steam) and
no gases.
· If the ambient temperature changes (change of location, e.g.
measurement indoors/outdoors), the instrument must be allowed to
equalise for aprox. 15 minutes.
· The instrument has a lens (90 % value) of 6:1 (distance : measuring
surface) + Opening diameter of the sensor (10mm / 0.39 in):
Distance Diameter of meas. surface Distance Diameter of meas. surface
10cm 3cm 4in 1.06in
60cm 11cm 25in 4.56in
100cm 18cm 40in 7.06in
200cm 35cm 80in 13.72in
Press and hold .
- flashes in the display. The laser dot marks the centre
of the measuring surface.
-
the
readings are held.
Using the product 19
Changing the display view:
Adjustable views
·Hold: Readings are held.
·Max: Maximum values since the instrument was last switched on or last reset.
·Min: Minimum values since the instrument was last switched on or last reset.
Press several times until the desired view appears.
Resetting Max/Min values:
1Press several times until the desired view appears.
2Press and hold until ---- appears.
3Repeat steps 1and 2for all values that are to be reset.
Switching the instrument off:
Press and hold until the display goes out.
Maintaining the product20
Maintaining the product
Changing batteries:
1To open the battery compartment, push the battery cover
down.
2Remove used batteries and insert new batteries
(2x 1.5 V type AAA). Observe the polarity!
3To close the battery compartment, push the battery cover
back on.
Cleaning the housing:
Clean the housing with a moist cloth (soap suds) if it is dirty.
Do not use aggressive cleaning agents or solvents!
Tips and assistance 21
Tips and assistance
Questions and answers
Question Possible causes/solutions
Hi or Lo · Readings outside the measuring range (too high, too
low): Keep to the permitted measuring range.
· Residual capacity <10 min: Change batteries.
If we could not answer your question, please contact your dealer
or Testo Customer Service. Contact details can be found on the
guarantee card or on the Internet at: www.testo.com
Notes22