LED STATUS INDICATION
Only available in walktest mode
(See Premier wireless expander instructions)
STANDARDS
Impaq and the wireless logo are trade marks of Texecom Ltd. © 2012
The Impaq Contact-W is protected by European Registered Design. No: 269188-0001
D20120815 INS468-6
WARRANTY
2 year replacement warranty (excludes battery).
The Impaq Contact-W is designed to detect the opening of
a door/window and activate an alarm control panel. As the Impaq
Contact-W is not a complete alarm system, but only a part thereof,
Texecom cannot accept responsibility or liability for any damages
whatsoever based on a claim that the Impaq Contact-W failed to function
correctly.
Due to our policy of continuous improvement Texecom reserves
the right to change specification without prior notice. All specifications
are measured at 20ºC (68ºF).
CertificateNumber:FM35285
Made In
England
ADDITIONAL INPUTS 1 & 2
Flashing Green: Withallcontactssecure,willflashevery
3seconds.
Red: Indicateseitherthereedswitchorexternal
contactsareactive.
The Impaq Contact-W has 2 additional inputs. These may be used for any
N/C device and utilise wireless signal transmission to the receiver. Typical
examples for use are:-
• Any locally powered device with a N/C output e.g. Smoke detectors,
Glass Break detectors, Movement Sensors, Flood detectors etc.
• Any non-powered N/C device, e.g. Additional magnetic contacts, fixed
PA buttons etc.
• The in-built reed switch can be disabled.
• Configuration and programming options are detailed in the Premier
wireless expander installation manual.
• Certain features and functions are control panel software dependent.
-35°C (-31°F) to
+60°C (+140°F)
88g (3.1oz) approx.
-10°C (14°F) to
+55°C (+131°F)
25mm (1”)
26mm (1”)
130mm
(5.1”)
33mm
13mm
Alarm
Systems:
EN50131-2-2, EN50131-5-3, EN50131-1,
PD6662, Grade 2 Class II*
EMC: EN50130-4:1995: A1: A2
ETSI EN301 489-03 V1.4.1
R&TTE: ETSI EN300-220 (V2.1.1)
Environmental: EN50130-5
Frequency Band: 868.0 - 868.6 MHz / 433.05 - 434.79 MHz
866.0 - 866.6 MHz •See product label
Product Type:
GBC1000-2 Frequency 868MHz
GBC2000** Frequency 433MHz
GBC3000 Frequency 866MHz
Receiver: Category 1, Class 2
Receiver LBT (Listen Before Talk) Yes
Transmitter Duty
Cycle 868Mhz<1%, 433Mhz<10%
Low Voltage Signal 2.85V
Operating Voltage 3V
Maximum current 32mA
Quiescent current 60uA
MAGNET POSITIONING
Fig.1
Y
X
Z
Y
X
Z
Magnetscanbeinstalledeitherside
oftheunit.
Material Approach Removal
Non-
Ferrous
+/-4mm
X=18mm
Y=10mm
Z=22mm
X=20mm
Y=12mm
Z=24mm
Ferrous
+/-3mm
X=8mm
Y=8mm
Z=16mm
X=9mm
Y=9mm
Z=18mm
*Certied by Det Norske Veritas: NORWAY ** Not INCERT approved.