Thermo Scientific MaxQ 2000 CO2 Plus User manual

Visit us online to register your warranty
www.thermoscientific.com/labwarranty
User Manual
MaxQ 2000 CO2lus
Digital CO2Resistant Shaker
Catalog #88881101, #88881102
#88881103, #88881104
Operation Manual 0000847

Thermo Scientific
MANUAL NUMBER 0000-847
1 - - 10/28/21 88881127B and 88881181 are introduced. TFI
0 0 18/11/2020 Original
REV ECR/ECN DATE DESCRI TION By
Preface
CO2esistant Shaker i

Thermo Scientificii CO2esistant Shaker
Preface
Do You Need Information or Assistance on
Thermo Scientific Products?
If you do, please contact us 8:00 a.m. to 6:00 p.m. (Eastern Time) at:
1-740-373-4763 Direct
1-800-438-4851 Toll Free, U.S. and Canada
1-877-213-8051 FAX
http://www.thermofisher.com Internet Worldwide Web Home Page
service.led.marietta@thermofisher.com Tech Support Email Address
Certified Service Web Pagewww.unitylabservices.com
Our staff can provide information on pricing and give you quotations. We canSales Support
take your order and provide delivery information on major equipment items or make
arrangements to have your local sales representative contact you. Our products are listed on the
Internet and we can be contacted through our Internet home page.
Our staff can supply technical information about proper setup, operation orService Support
troubleshooting of your equipment. We can fill your needs for spare or replacement parts or
provide you with on-site service. We can also provide you with a quotation on our Extended
Warranty for your Thermo Scientific products.
Whatever Thermo Scientific products you need or use, we will be happy to discuss your
applications. If you are experiencing technical problems, working together, we will help you
locate the problem and, chances are, correct it yourself...over the telephone without a service
call.
When more extensive service is necessary, we will assist you with direct factory trained
technicians or a qualified service organization for on-the-spot repair. If your service need is
covered by the warranty, we will arrange for the unit to be repaired at our expense and to your
satisfaction.
Regardless of your needs, our professional telephone technicians are available to assist you
Monday through Friday from 8:00 a.m. to 6:00 p.m. Eastern Time. Please contact us by
telephone or fax. If you wish to write, our mailing address is:
Thermo Fisher Scientific (Asheville) LLC
401 Millcreek Road, Box 649
Marietta, OH 45750
International customers, please contact your local Thermo Scientific distributor.

CO2esistant Shaker iiiThermo Scientific
Table of Contents
Unpacking and Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Packing List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Universal (Aluminum) Platform Installation . . . . . . . . . . . . . . . . . . .1-3
18 inch (Aluminum) Platform Installation . . . . . . . . . . . . . . . . . . . . .1-4
Rubber Mat Platform Installation . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5
Connections of the Instrument . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1
Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2
Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2
Storing the Signal Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Output Current of Control Box . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Maximum Shaking Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
Operations on the Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
Speed and Time Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2
Alarm System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-3
Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1
Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1
Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-1
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-1
Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-1
Section 1
Section 2
Section 3
Section 4
Section 5
Section 6
Section 7
Section 8

iv CO2esistant Shaker Thermo Scientific
Table of Contents

CO2esistant Shaker 1-1Thermo Scientific
Section 1 Unpacking and Installation
1. Inspect contents upon receipt of the instrument, if the instrument is
upside down, contact the manufacturer immediately.
2. Check packing list below. If there are any damaged or missing items,
contact the manufacturer.
3. Place the instrument on a level and firm surface, to avoid vibration and
noise.
Thermo
Scientific
Cat. No.
88881101 88881102 88881103 88881104
ictutre
Model name on
carton box label.
MaxQ 2000 CO2
lus, 100-240V,
for USA
MaxQ 2000 CO2
lus,
100-240V,
various plugs
MaxQ 2000 CO2 lus
romotion ackage
for USA, includes
CO2 resistant shaker
(88881101), Universal
latform and Flask
Clamp Starter Kit
MaxQ 2000 CO2 lus
romotion ackage for
EMEA & A AC, includes
CO2 resistant shaker
(88881102), Universal
latform & Flask Clamp
Starter Kit
Main Body 1 1 1 1
Control Box 1 1 1 1
General Power
Adaptor 1 1 1 1
US Plug 1 N/A 1 N/A
CN Plug N/A 1 N/A 1
Table 1-1. Packing List

1-2 CO2esistant Shaker Thermo Scientific
Section 1
Unpacking and Installation
Thermo
Scientific
Cat. No.
88881101 88881102 88881103 88881104
ictutre
Model name on
carton box label.
MaxQ2000CO2
lus, 100-240V,
for USA
MaxQ2000CO2
lus, 100-240V,
various plugs
MaxQ2000CO2 lus
romotion ackage
for USA, includes
CO2 resistant shaker
(88881101), Universal
latform and Flask
Clamp Starter Kit
MaxQ2000CO2 lus
romotion ackage for
EMEA & A AC,
includes CO2 resistant
shaker (88881102),
Universal latform &
Flask Clamp Starter Kit
EU Plug N/A 1 N/A 1
UK Plug N/A 1 N/A 1
Universal
Platform (AL) N/A N/A 1 1
100ml Flask
Clamp N/A N/A 2 2
250ml Flask
Clamps N/A N/A 4 4
500ml Flask
Clamps N/A N/A 4 4
1L Flask Clamps N/A N/A 2 2
2L Flask Clamps N/A N/A 2 2
Data Port 1 1 1 1
Table 1-1. Packing List (Continued)

1. Place the instrument on a level and firm surface; it must be capable
of supporting the weight and load of the instrument, and the impact
force generated by the motion. Prepare related parts (see Figure 1-1).
2. Install the horizontal universal platform on the fixed plate of the Main
body, ensure all four mounting holes in the universal platform and the
four threaded mounting holes are in alignment.
3. Fasten the universal platform and the fixed plate with four M4x14
cross recessed countersink head screws.
CO2esistant Shaker 1-3Thermo Scientific
Section 1
Unpacking and Installation
Universal (Aluminum)
latform Installation
Figure 1-1. Universal Platform Installation Diagram
1) M4x14 cross recessed countersink head screws
2) Universal (aluminum) platform
3) Main body of CO2resistant shaker

1-4 CO2esistant Shaker Thermo Scientific
Section 1
Unpacking and Installation
1. Place the instrument on a level and firm surface; it must be capable
of supporting the weight and load of the instrument, and the impact
force generated by the motion. Prepare related parts (see Figure 1-2).
2. Install the horizontal universal platform on the fixed plate of the Main
body, ensure all four mounting holes in the universal platform and the
four threaded mounting holes are in alignment.
3. Fasten the universal platform and the fixed plate with four M4x14
cross recessed countersink head screws.
18 inch (Aluminum)
latform Installation
Figure 1-2. 18 inch Platform Installation Diagram
1) M4x14 cross recessed countersink head screws
2) 18 inch (aluminum) platform
3) Main body of CO2resistant shaker

1. Place the instrument on a level and firm surface; it must be capable
of supporting the weight and load of the instrument, and the impact
force generated by the motion. Prepare related parts (see Figure 1-3).
2. Install the horizontal platform on the fixed plate of the Main body;
ensure all four mounting holes on the platform and the four threaded
mounting holes are in alignment.
3. Fasten the platform and the fixed plate with four M4x10 cross recessed
countersink head screws.
4. Place the rubber mat on the platform.
Rubber Mat latform
Installation
Figure 1-2. Universal Platform Installation Diagram
1) Rubber mat
2) M4x10 cross recessed countersunk head screws
3) Platform
4) Main body of CO2resistant shaker
CO2esistant Shaker 1-5Thermo Scientific
Section 1
Unpacking and Installation

Refer to Figure 1-4 when connecting the instrument.
Note:
1) When diconnecting the control box from the main body, please cut off
the power first. ▲
2) No special cable needed to connect with 4-20mA data port. ▲
Connections of the
Instrument
Figure 1-4. Circuit Diagram
1) Main body of CO2resistant shaker
2) Control box
3) Power adapter
4) Power cord
5) 4-20mA data port
1-6 CO2esistant Shaker Thermo Scientific
Section 1
Unpacking and Installation

CO2esistant Shaker 2-1Thermo Scientific
Section 2 Overview
Rotatio Speed
Speed Range . . . . . . . . . . . . . . . . . . . .30 to 300 rpm
Speed Accuracy . . . . . . . . . . . . . . . . . . . . .±1 rpm
Orbit Diameter . . . . . . . . . . . . . . . . . . . . .Ø19mm
Motion Type . . . . . . . . . . . . . . . . . . . . . . . .Orbital
Speed Display . . . . . . . . . . . . . . . . . . . . . . . . .LED
Load
Maximum Load . . . . . . . . . . . . . . . . .6kg @≤300 rpm
Timer
Timer Range . . . . . . . . . . . . . . . . .099h 59min.
Hour Display . . . . . . . . . . . . . . . . . . . . . . . . .LED
Minute Display . . . . . . . . . . . . . . . . . . . . . . .LED
Dime sio s (WxDxH)
Main body . . . . .360 x 300 x 96mm (14.2 x 11.8 x 3.8 inch)
Control Box . . . . 213 x 95 x 26mm (8.4 x 3.7 x 1.0 inch)
Weight
Net Weight (Main body) . . . . . . . . . . . . .17.5 kg (38.58 lbs)
Net Weight (Control Box) . . . . . . . . . . . . . .0.3 kg (0.66 lbs)
Gross weight . . . . . . . . . . . . . . . . . . . . . . . .19 kg (41.9 lbs)
Power Supply
Requirement . . . . . . . . . . . . . . . . . . .AC100 - 240V, 50/60Hz
Other
Certification . . . . .ROHS, WEEE, cCSAus, CE Mark
Noise level . . . . . . . . . . . . . . . . . . . . . . . . . .<60dB
IP Class . . . . . . . . . . . . . . . . . . . . . . . . . . . .IP21
Specifications

2-2 CO2esistant Shaker Thermo Scientific
Section 2
Overview
Applicatio E viro me t Co ditio s: I door use
Temperature . . . . . . . . . . . . . . . . . . . . . 4°C to 60°C
Altitude . . . . . . . . . . . . . . . . . . . . . . . . . ≤2,000 m
Humidity . . . . . . . . . . . . . . . . . . . . . . . .20% to 99%
CO2Concentration . . . . . . . . . . . . . . . . .0% to 20%
Storage E viro me tal Co ditio s
Temperature . . . . . . . . . . . . . . . . . . . .5°C to 60°C
Altitude . . . . . . . . . . . . . . . . . . . . . . . . . .≤2,000m
Humidity . . . . . . . . . . . . . . .20% to 99%, Non-Condensing
1. Unplug and unload before moving the unit.
2. This instrument uses a single-phase AC100 - 240V 50/60Hz power
supply.
3. Remove the power supply when the instrument is in maintenance.
4. DO NOT clean the unit with flammable or corrosive liquid.
5. Use specified power supply.
6. Maximum load 6kg (13.23 lbs.) @≤300 rpm
7. To ensure proper operation, the unit must be free of surrounding
obstructions.
Environmental
Conditions
Safety Tips

To store the signal cable, simply open the side plate on the main body.
Refer to Figure 2-1. The signal cable can be placed inside.
Caution When storing the cable, pay attention to closing the side plate
door, to avoid pinching your fingers. ▲
Section 2
Overview
Storing the Signal
Cable
Figure 2-1. Storing the Signal Cable Diagram
1) Main body of CO2resistant shaker
2) Slide plate
3) Control box
CO2esistant Shaker 2-3Thermo Scientific
Orbital Speed vs.
Output Current
Monitoring System
Figure 2-2. Output Current Monitoring System
1) Control box
2) Data port

2-4 CO2esistant Shaker Thermo Scientific
Section 2
Overview
Orbital Speed vs.
Output Current
Monitoring System
(Continued)
Table 2-1. Output current under different speed conditions
Speed (rpm) Output current (mA)
0 4
30 4.8
300 20

CO2esistant Shaker 2-5Thermo Scientific
Section 2
Overview
Maximum Shaking
Speed Flask Size
Max Speed (rpm)
Size Liquid Volume
50ml ≤50ml 200
100ml ≤100ml 150
150ml ≤150ml 150
200ml ≤200ml 150
250ml ≤250ml 150
500ml ≤500ml 150
1000ml ≤1000ml 150
2000ml ≤2000ml 150
3000ml ≤3000ml 150
5000ml ≤5000ml 150
Table 2-2. Maximum Shaking Speed on ubber Platform in elation to Flask Size
Flask Size Max Flask
Capacity Max Speed (rpm)
Size Liquid Volume
50ml ≤50ml 30 300
100ml ≤100ml 15 300
150ml ≤150ml 15 300
200ml ≤200ml 15 300
250ml ≤250ml 15 300
500ml ≤500ml 9 300
1000ml ≤500ml 4 260
≤1000ml 4 240
2000ml ≤1000ml 4 240
≤2000ml 4 220
3000ml ≤1500ml 3 250
≤3000ml 3 220
5000ml ≤2500ml 1 220
≤5000ml 1 200
Table 2-3. Maximum Shaking Speed and Flask Capacity on Universal Platform

2-6 CO2esistant Shaker Thermo Scientific
Section 2
Overview
Note:
1) The flask clamps (≤2L) can be placed anywhere on the universal
(aluminum) platform, even if the load is not balanced. ▲
2) Please refer to the “Liquid Volume” table in the specifications section
for the maximum load. ▲
Note:
1) The flask clamps (<2L) can be placed anywhere on the 18 inch
(aluminum) platform, even if the load is not balanced. ▲
2) Please refer to the “Liquid Volume” table in the specifications section
for the maximum load. ▲
Flask Size Max Flask
Capacity Max Speed (rpm)
Size Liquid Volume
50ml ≤50ml 49 210
100ml ≤100ml 25 210
150ml ≤150ml 25 210
200ml ≤200ml 18 210
250ml ≤250ml 18 210
500ml ≤500ml 10 190
1000ml ≤500ml 7 200
≤1000ml 7 190
2000ml ≤1000ml 4 180
≤2000ml 4 180
3000ml ≤1500ml 4 160
≤3000ml 2 150
5000ml ≤2500ml 2 170
≤5000ml 1 150
Table 2-4. Maximum Shaking Speed and Flask Capacity on 18 inch (aluminum)
Platform
Maximum Shaking
Speed (Continued)

CO2esistant Shaker 3-1Thermo Scientific
Section 3 Operation
The unit has been designed with a “soft start/slow down” providing a
smooth acceleration/deceleration during operation. This feature will
decrease splashing of solutions from vessels during operation.
Warning The microprocessor control system may take 1 minute to
synchronize the actual RPM of the universal (aluminum) platform to the
desired RPM setting. Make sure that all the flasks and test tubes are firmly
fixed on the universal platform and the flask clamps are fasten securely
with the screws. s
Operations on the
Control anel

3-2 CO2esistant Shaker Thermo Scientific
Section 3
Operation
Operations on the
Control anel
(Continued)
1) Display LED: Shows time or speed
2) RPM indicator light: LED shows current speed
3) TIME indicator light: LED shows current time.
4) WARN indicator light: Over-speed alarm.
5) RUN indicator light: The instrument is running.
6) RPM/TIME ey: While instrument is in operation, press to change
time and speed display; when setting parameter, press to change
minutes, hour or speed.
7) Up Arrow ey: Increases value. Hold for 3 seconds to increase rapidly.
8) Down Arrow ey: Decreases value. Hold for 3 seconds to decrease
rapidly.
9) ey: The power is On/Off.
10) Run/Stop ey: The instrument is running or stopped.
Speed setti g
1. Press RPM/TIME key. The speed indicator light is lit.
2. Press up and down arrow keys to access the speed setting state, speed
value starts flashing.
3. Press up and down arrow keys to change the speed value. Speed
increases or decreases. The minimum unit is 1rpm.
4. During settings, the unit will reset to current values if no value is input
after three seconds.
5. Press “Run/Stop” key to run or stop.
Time setti g
1. Press RPM/TIME key. The time indicator light is lit.
2. Press up and down arrow keys to access the speed setting state. Speed
value starts flashing.
3. Press up and down arrow keys to change the time value. Time
increases or decreases. The minimum unit is 1 minute or 1 hour.
4. During settings, the unit will reset to current values if no value is input
after three seconds.
5. Press “Run/Stop” key to run or stop.
Speed and Time
Settings

CO2esistant Shaker 3-3Thermo Scientific
Section 3
Operation
Notes
1. When the shaker is running, the LED display will switch between the
speed and timer function every 30 seconds automatically. Press
RPM/TIME key to manually toggle between the speed and timer
value.
2. In “timer mode” the LED display will show the remaining running
time.
3. In “continuous mode” the LED display will show elapsed run time.
4. After the run is complete, the LED display will read “end”. Press any
key to place the shaker in standby mode.
Alarm System
1. During operation, the alarm will sound after 10 seconds if the unit has
not begun shaking. In addition, the alarm will sound and stop for the
speed over 350 rpm after 2 seconds.
2. Once the shaker begins to alarm, the RUN indicator light will not be
visible and the WARN indicator light will flash, and the unit will stop
running.
Power failure recovery
When the power supply is cut off suddenly to the shaker, resulting in a
power failure, the unit will automatically run at the previous set parameter
upon power restoration.
Speed and Time
Settings (Continued)
Alarm System
Other manuals for MaxQ 2000 CO2 Plus
2
This manual suits for next models
4
Table of contents
Other Thermo Scientific Paint Sprayer manuals
Popular Paint Sprayer manuals by other brands

IMC
IMC IMCNL-HD-PY02 Series Operation manual

Mesto
Mesto RESISTENT EXTRA 3592 Instructions for use

Nordson
Nordson Universal Series Customer product manual

Campbell Hausfeld
Campbell Hausfeld AL2810 Operating instructions and parts manual

Birchmeier
Birchmeier REC 15 AC1 Instructions for use

Binks
Binks Cub SL 7011 Series manual