3. WIRING
3.1. Connection Diagram
3.2. The Type of Cables
The types of cables are to be determined according to the
following conditions.
• Twisted pair wires (such as those used for electronic push-
button telephone) are to be used for wiring between the
Exchange and the stations in principle.
• The number of cables pairs laid should be determined
considering the possibility of future expansion of the
system.
• Outdoor wires should be used where wiring passes through
inaccessible areas such as ceilings or under floors where
the maintenance is not performed. Indoor wires may also be
used, however, in case where there is no risk of
deterioration due to exposure to heat, etc.
Note
Specifications related to each junction are as follows.
Mini-clamp connector (N-8000EX line terminal)
Conductor diameter: ø 0.4 – 0.65 mm (AWG22 – 26),
Solid wire
Outside diameter: ø 1.05 mm or below
Clip terminal (E-7000TB)
Conductor diameter: ø 0.4 – 0.8 mm (AWG20 – 26), Solid
wire
Outside diameter: ø 1.5 mm or below
3.3. Relations Between Core Diameter of Cable and
Maximum Cable Length
Referring to the following chart as guidelines, design the
distance between the Exchange and stations so that loop
resistance value becomes 170 Ωor less.
3.4. Mini-Clamp Connector Connection
Mini-clamp connectors for line terminals are supplied with the
N-8000EX Exchange.
Connect the mini-clamp connector to a cable using a
commercially available tool (pliers).
Step 1. Cut off two-cable ends in equal length, and insert
them securely to a cover section (transparent side)
of the mini-clamp connector.
Note
Insert the cable without stripping the cable jacket.
Step 2. With a pair of pliers, lightly pinch the mini-clamp
cover and, after ensuring that the cable is securely
inserted, firmly squeeze on the cover.
Note
Squeeze on the mini-clamp cover until it is correctly
locked.
Step 3. Insert the wired connector (plug) into the exchange's
connector (socket) until it locks into place.
Printed in Japan
133-06-260-5B
1. WALL MOUNTING
The station can be mounted on a wall using an optional
YC-290 wall mounting bracket.
The YC-290 can be installed to JIS standard one gang switch
box.
1.1. Mounting Example
Step 1. Install the YC-290 Wall mounting bracket to the wall.
Notes
• Use appropriate screws for the construction of wall.
• Wooden screws 3.5 x 20 are supplied with the
YC-290.
• No fitting screws for switch box are supplied.
Step 2. Hang the station on the Wall mounting bracket hook
to install.
Push down the station main body in the direction
indicated by the arrow.
2. DESK-TOP INSTALLATION
In desktop installations, the front operation panel can be
inclined 16˚ from the desk surface for easier operation by
attaching the YC-290 Wall Mounting Bracket to its bottom
surface.
2.1. Mounting Example
Hang the Wall mounting bracket hook on the station's wall
bracket mounting slot to install.
Push up the Wall mounting bracket in the direction indicated
by the arrow.
This Master Station is designed to connect to the IP Intercom Exchange, and provides hands-free conversation of high sound
quality. With its space-saving design, this Master Station features the same functions as the Standard Master Station.
Using an optional YC-290 Wall Mounting Bracket, this station can be mounted on a wall, or tilted for easy key operation when
used on a desktop.
Warning
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be
required to take adequate measures.
N-8011MS
STANDARD HANDS-FREE MASTER STATION
INSTALLATION MANUAL
1
2
YC-290 Wall mounting bracket
Station
Wooden screw 3.5 x 20
(supplied with the YC-290)
Hook
Wall
surface
2-ø4.5
4.6 x 6
83.5
23.5
131.5
60
5037
50
34
64
4.5 x 10
[YC-290 Dimensional drawing]
Unit: mm
Rubber foot mounting position
(desk-top application)
92 72.1
60.7
195
YC-290
[Installation completion drawing]
YC-290
Unit: mm
YC-290 Wall
mounting bracket
Hook
Rubber foot
(supplied with
the YC-290)
Station
16°
90
[Installation completion drawing]
192.3
YC-290
Unit: mm
Both upper and lower
terminals (clip terminals)
are internally connected.
E-7000TB
Terminal board
Station
Connection cable
(accessory)
RJ-11 modular rosette
(commercially available)
Mini-clamp connector
(Supplied with the N-8000EX)
To N-8000EX Exchange
16 lines
Cover (transparent side)
Cable
N-8000EX Rear panel
To connect the cables from the N-8000EX
Exchange to the Master Station, use the supplied
connection cable and a commercially available RJ-
11 modular jack. These cables have no polarity.
Conductor
diameter
(mm)
ø
0.4
ø
0.5
ø
0.65
ø
0.9
Maximum cable length between the
Exchange and station
(Assuming that the loop resistance is 170 Ω.)
570 m
900 m
1.5 km
2.9 km
Loop
resistance
(Ω/km)
295
187
113
58

Other manuals for N-8011MS

1

Other Toa Intercom System manuals

Toa N-8050DS User manual

Toa

Toa N-8050DS User manual

Toa VS-900 Manual

Toa

Toa VS-900 Manual

Toa IC-100 Series Manual

Toa

Toa IC-100 Series Manual

Toa CP-62 User manual

Toa

Toa CP-62 User manual

Toa TD-600 User manual

Toa

Toa TD-600 User manual

Toa N-8031SB User manual

Toa

Toa N-8031SB User manual

Toa N-8031MS User manual

Toa

Toa N-8031MS User manual

Toa DT-E70 User manual

Toa

Toa DT-E70 User manual

Toa VS-900CO User manual

Toa

Toa VS-900CO User manual

Toa EX-610 System manual

Toa

Toa EX-610 System manual

Toa MS-900 User manual

Toa

Toa MS-900 User manual

Toa XRS-101SS User manual

Toa

Toa XRS-101SS User manual

Toa VS-900SC User manual

Toa

Toa VS-900SC User manual

Toa CP-66 Parts list manual

Toa

Toa CP-66 Parts list manual

Toa VS-900 User manual

Toa

Toa VS-900 User manual

Toa N-8000AL User manual

Toa

Toa N-8000AL User manual

Toa CP-66 System manual

Toa

Toa CP-66 System manual

Toa N-8000MS User manual

Toa

Toa N-8000MS User manual

Toa N-8000MI User manual

Toa

Toa N-8000MI User manual

Toa EX-630 User manual

Toa

Toa EX-630 User manual

Toa MS-900 User manual

Toa

Toa MS-900 User manual

Toa TK-20 User manual

Toa

Toa TK-20 User manual

Toa EXES 6000 CP-63 System manual

Toa

Toa EXES 6000 CP-63 System manual

Toa N-8000 SERIES User manual

Toa

Toa N-8000 SERIES User manual

Popular Intercom System manuals by other brands

Commax DRC-703LC/RF1 user manual

Commax

Commax DRC-703LC/RF1 user manual

XtendLan DPC-D248-R user manual

XtendLan

XtendLan DPC-D248-R user manual

Grandstream Networks GSC3570 Quick installation guide

Grandstream Networks

Grandstream Networks GSC3570 Quick installation guide

Elvox Giotto 6341 user guide

Elvox

Elvox Giotto 6341 user guide

Becker S60II operating instructions

Becker

Becker S60II operating instructions

urmet domus IPerVoice 1716 Installation handbook

urmet domus

urmet domus IPerVoice 1716 Installation handbook

Sentinel VI350 instruction manual

Sentinel

Sentinel VI350 instruction manual

DoorBird D10 Series installation manual

DoorBird

DoorBird D10 Series installation manual

2N Helios Uni installation manual

2N

2N Helios Uni installation manual

Fanvil i12-02 user manual

Fanvil

Fanvil i12-02 user manual

Commax CDV-43Q user manual

Commax

Commax CDV-43Q user manual

TekTone Tek-View VM600A installation instructions

TekTone

TekTone Tek-View VM600A installation instructions

Commax DRC-40DK user manual

Commax

Commax DRC-40DK user manual

Renkforce 1275880 operating instructions

Renkforce

Renkforce 1275880 operating instructions

HME DX121 operating instructions

HME

HME DX121 operating instructions

Amroad AMROAD P3 Technical manual

Amroad

Amroad AMROAD P3 Technical manual

Aiphone AP-10M installation manual

Aiphone

Aiphone AP-10M installation manual

Xicom XT692-SD user manual

Xicom

Xicom XT692-SD user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.