manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Toa
  6. •
  7. Intercom System
  8. •
  9. Toa N-8050DS User manual

Toa N-8050DS User manual

INSTALLATION
MANUAL
DOOR STATION N-8050DS
1. GENERAL DESCRIPTION
Designed to connect to the IP Intercom Exchange, the
N-8050DS is a door station featuring high quality hands-free
conversation and has a contact output (momentarily closed)
to remotely control an electronic door lock.
Using with an electrical box or surface mounting box, the
station can be mounted to a wall.
The N-8050DS is in full conformity with IP54 water-proof and
dust-proof standards. The operating temperature range is –10
to +50°C.
As provided with guard nets inside to cover over the openings
of microphone and speaker, the N-8050DS can be installed
free from care in public space.
2. WALL MOUNTING
2.1. Mounting to a 3-gang Switch Box (with cover)
Mount the N-8050DS to electrical
boxes mounted in the wall.
Notes
• The wall should be over 12 mm thick, and the opening in the
wall for an electrical box should be under 115 mm (wide) by
162 mm (high).
• When using for electronic door lock control, x the
N-8050DS with tamper-proof screws such as "Torx" screws
to prevent it from being easily removed.
• Be sure to ground the electrical box.
2.2. Mounting to the YS-13A Wall Mount Box
Install the YS-13A on a wall and mount the station in the same
way as 2.1.
4.2. Connection to an External Relay
Wall
[Section view]
N-8050DS
Acoustic material (accessory)
Note
Lay it down along the inside
of the box.
Oval head combination screw
M4 x 25 (accessory)
YC-150 Back box (option)
or 3-gang electrical box
Wall surface
N-8050DS
The N-8050DS comes with 2 types of screws: oval head
combination screw M4 x 25 and oval head combination screw
UNC No.6 x 18. For the electrical box provided with unied
threads, use the oval head combination screws UNC No.6 x 18.
Accessory screws
Open collector output: 30 V DC, 50 mA
External
power supply
Relay
Diode
N-8000EX/8010EX Exchange
+24 V DC
GND
+
-
N-8050DS (Rear panel)
LINE H C
3. INSTALLATION PRECAUTIONS
• When installing the N-8050DS outdoors
or at locations where it gets wet with
water, tightly seal the panel edges.
Besides, provide a weep hole at the
underside of the mounting box to permit
water to drain off.
• When installing the N-8050DS under
difficult environmental conditions
such as in coastal areas or at humid
locations, cover the inside of the
N-8050DS with coating. For the coating
method, consult TOA sales office.
4. WIRING
4.1. Connection to the Exchange
ConnecttheExchangetothestation’sLINEterminalsviathe
E-7000TB Terminal Board as illustrated.
Seal the panel edges.
N-8050DS’s
front panel
E-7000TB
Terminal board
Mini-clamp connector
(Supplied with the
N-8000EX/8010EX)
Twisted pair cable
N-8000EX/8010EX Exchange
16 lines
N-8050DS (rear panel)
LINE H C
Both upper and lower
terminals (clip terminals)
are internally connected.
URL:https://www.toa.jp/
133-06-00031-01
Traceability Information for Europe
Manufacturer:
TOA Corporation
7-2-1,Minatojima-Nakamachi,Chuo-ku,Kobe,Hyogo,Japan
Authorized representative:
TOAElectronicsEuropeGmbH
Suederstrasse282,20537Hamburg,Germany
4.3. Type of Cable
The types of cables are to be determined according to the
following conditions.
• Twisted pair wires (such as those used for electronic push-
button telephone) are to be used for wiring between the
Exchange and the stations in principle.
• The number of cables pairs laid should be determined
considering the possibility of future expansion of the system.
• Outdoor wires should be used where wiring passes through
inaccessibleareas suchasceilingsor under oorswhere
the maintenance is not performed. Indoor wires may also be
used, however, in case where there is no risk of deterioration
due to exposure to heat, etc.
Note
Specificationsrelatedtoeachjunctionareasfollows.
Mini-clampconnector(N-8000EX/8010EXlineterminal)
Conductor diameter: ø0.4 – 0.65 mm (AWG22 – 26),
solid wire
Outside diameter: ø1.05 mm or below
Clip terminal (E-7000TB)
Conductor diameter: ø0.4 – 0.8 mm (AWG20 – 26),
solid wire
Outside diameter: ø1.5 mm or below
Terminalstation(LINE,H,Cterminals)
Conductor diameter: ø0.4 – 1.3 mm (AWG16 – 26),
solid wire, stranded wire
4.4. Relations Between Core Diameter of Cable and
Maximum Cable Length
Referring to the following chart as guidelines, design the
distance between the Exchange and stations so that loop
resistancebecomes170Ωorless.
Conductor
diameter
(mm)
Loop
resistance
(Ω/km)
Maximum cable length
between the Exchange and station.
(Assumingthattheloopresistanceis170Ω.)
ø0.4 295 570 m
ø0.5 187 900 m
ø0.65 113 1.5 km
ø0.9 58 2.9 km
4.5. Terminal Station Connection
Step 1. Stripacablejacketofapprox7mmtoexposeinner
cable.
For cables, refer to Type of Cable.
7 mm
Note
Do not solder plate on exposed inner cables when
using a stranded wire.
Step 2. Loosentheterminalscrewsandinsertthecables.
Step 3. Tighten the terminal screws securely.
Notes
• Tug lightly on the cable to be sure that it does not
pull free. If the cable pulls free, loosen the terminal
screw again and reconnect from Step 2.
• To avoid stripping the screws,
use the screwdriver appropriate
to the screws tightened into the
terminal plug.
4.6. Mini-clamp Connector Connection
Connect the mini-clamp connector supplied with the
N-8000EX/8010EXtoacableusingacommerciallyavailable
tool (pliers).
Step 1. Cut off two-cable ends in equal length, and insert
them securely to a cover section (transparent side)
of the mini-clamp connector.
Note
Insert the cable without stripping
thecablejacket.
Step 2. With a pair of pliers, lightly pinch the
mini-clamp cover and, after ensuring
that the cable is securely inserted,
rmlysqueezeonthecover.
Note
Squeeze on the mini-clamp cover until it is correctly
locked.
Step 3. Insertthewiredconnector(plug)intotheexchange’s
connector (socket) until it locks into place.
Cover
(transparent side)
Cable
N-8000EX/8010EX Rear panel
Tighten
Terminal screw
Cable
Warning
This is a class A product. In a domestic environment this
product may cause radio interference in which case the user
may be required to take adequate measures.

Other manuals for N-8050DS

2

Other Toa Intercom System manuals

Toa CP-66 User manual

Toa

Toa CP-66 User manual

Toa N-8540DS User manual

Toa

Toa N-8540DS User manual

Toa EXES-5000 User manual

Toa

Toa EXES-5000 User manual

Toa CPU-52A System manual

Toa

Toa CPU-52A System manual

Toa N-8031MS User manual

Toa

Toa N-8031MS User manual

Toa EXES 6000 CP-63 System manual

Toa

Toa EXES 6000 CP-63 System manual

Toa N-8640SB User manual

Toa

Toa N-8640SB User manual

Toa N-8011MS User manual

Toa

Toa N-8011MS User manual

Toa N-8000EX User manual

Toa

Toa N-8000EX User manual

Toa EXES 6000 CP-66 System manual

Toa

Toa EXES 6000 CP-66 System manual

Toa EXES-6000 Guide

Toa

Toa EXES-6000 Guide

Toa N-SP80MS1 User manual

Toa

Toa N-SP80MS1 User manual

Toa AD-1210P User manual

Toa

Toa AD-1210P User manual

Toa N-XC65-W User manual

Toa

Toa N-XC65-W User manual

Toa RS-150 User manual

Toa

Toa RS-150 User manual

Toa RS-480VSET User manual

Toa

Toa RS-480VSET User manual

Toa N-8000DI User manual

Toa

Toa N-8000DI User manual

Toa N-8000MS User manual

Toa

Toa N-8000MS User manual

Toa VS-900CO User manual

Toa

Toa VS-900CO User manual

Toa CP-62 User manual

Toa

Toa CP-62 User manual

Toa IP-A1 Series User guide

Toa

Toa IP-A1 Series User guide

Toa EXES-5000 System manual

Toa

Toa EXES-5000 System manual

Toa CCU-11B System manual

Toa

Toa CCU-11B System manual

Toa TD-600 User manual

Toa

Toa TD-600 User manual

Popular Intercom System manuals by other brands

suprema FaceStation user manual

suprema

suprema FaceStation user manual

Aiphone GF-1DK Operation manual

Aiphone

Aiphone GF-1DK Operation manual

Opiz OP-D6D19 user manual

Opiz

Opiz OP-D6D19 user manual

GEV CSS 9875 manual

GEV

GEV CSS 9875 manual

SECO-LARM DP-234Q Installation and operation manual

SECO-LARM

SECO-LARM DP-234Q Installation and operation manual

DORANI TOUCH Series troubleshooting guide

DORANI

DORANI TOUCH Series troubleshooting guide

Vimar Elvox 6600 Series Installer's guide

Vimar

Vimar Elvox 6600 Series Installer's guide

Bell System 500D Wiring diagram

Bell System

Bell System 500D Wiring diagram

ZKTeco VEX-B21L user manual

ZKTeco

ZKTeco VEX-B21L user manual

Bellman & Symfon BE1411 user manual

Bellman & Symfon

Bellman & Symfon BE1411 user manual

Aiphone TD-12Z instructions

Aiphone

Aiphone TD-12Z instructions

Extel LENA 18 .2 Installation and user guide

Extel

Extel LENA 18 .2 Installation and user guide

Videx VR120 VANDAL Technical manual

Videx

Videx VR120 VANDAL Technical manual

Divus OPENDOOR manual

Divus

Divus OPENDOOR manual

2N Helios Uni installation manual

2N

2N Helios Uni installation manual

sks FS 4510 operating instructions

sks

sks FS 4510 operating instructions

Aiphone NE-SS-1G instructions

Aiphone

Aiphone NE-SS-1G instructions

Digital Acoustics IP7-FX Reference manual

Digital Acoustics

Digital Acoustics IP7-FX Reference manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.