INSTALLATION
MANUAL
DOOR STATION N-8050DS
1. GENERAL DESCRIPTION
Designed to connect to the IP Intercom Exchange, the
N-8050DS is a door station featuring high quality hands-free
conversation and has a contact output (momentarily closed)
to remotely control an electronic door lock.
Using with an electrical box or surface mounting box, the
station can be mounted to a wall.
The N-8050DS is in full conformity with IP54 water-proof and
dust-proof standards. The operating temperature range is –10
to +50°C.
As provided with guard nets inside to cover over the openings
of microphone and speaker, the N-8050DS can be installed
free from care in public space.
2. WALL MOUNTING
2.1. Mounting to a 3-gang Switch Box (with cover)
Mount the N-8050DS to electrical
boxes mounted in the wall.
Notes
• The wall should be over 12 mm thick, and the opening in the
wall for an electrical box should be under 115 mm (wide) by
162 mm (high).
• When using for electronic door lock control, x the
N-8050DS with tamper-proof screws such as "Torx" screws
to prevent it from being easily removed.
• Be sure to ground the electrical box.
2.2. Mounting to the YS-13A Wall Mount Box
Install the YS-13A on a wall and mount the station in the same
way as 2.1.
4.2. Connection to an External Relay
Wall
[Section view]
N-8050DS
Acoustic material (accessory)
Note
Lay it down along the inside
of the box.
Oval head combination screw
M4 x 25 (accessory)
YC-150 Back box (option)
or 3-gang electrical box
Wall surface
N-8050DS
The N-8050DS comes with 2 types of screws: oval head
combination screw M4 x 25 and oval head combination screw
UNC No.6 x 18. For the electrical box provided with unied
threads, use the oval head combination screws UNC No.6 x 18.
Accessory screws
Open collector output: 30 V DC, 50 mA
External
power supply
Relay
Diode
N-8000EX/8010EX Exchange
+24 V DC
GND
+
-
N-8050DS (Rear panel)
LINE H C
3. INSTALLATION PRECAUTIONS
• When installing the N-8050DS outdoors
or at locations where it gets wet with
water, tightly seal the panel edges.
Besides, provide a weep hole at the
underside of the mounting box to permit
water to drain off.
• When installing the N-8050DS under
difficult environmental conditions
such as in coastal areas or at humid
locations, cover the inside of the
N-8050DS with coating. For the coating
method, consult TOA sales office.
4. WIRING
4.1. Connection to the Exchange
ConnecttheExchangetothestation’sLINEterminalsviathe
E-7000TB Terminal Board as illustrated.
Seal the panel edges.
N-8050DS’s
front panel
E-7000TB
Terminal board
Mini-clamp connector
(Supplied with the
N-8000EX/8010EX)
Twisted pair cable
N-8000EX/8010EX Exchange
16 lines
N-8050DS (rear panel)
LINE H C
Both upper and lower
terminals (clip terminals)
are internally connected.
URL:https://www.toa.jp/
133-06-00031-01
Traceability Information for Europe
Manufacturer:
TOA Corporation
7-2-1,Minatojima-Nakamachi,Chuo-ku,Kobe,Hyogo,Japan
Authorized representative:
TOAElectronicsEuropeGmbH
Suederstrasse282,20537Hamburg,Germany
4.3. Type of Cable
The types of cables are to be determined according to the
following conditions.
• Twisted pair wires (such as those used for electronic push-
button telephone) are to be used for wiring between the
Exchange and the stations in principle.
• The number of cables pairs laid should be determined
considering the possibility of future expansion of the system.
• Outdoor wires should be used where wiring passes through
inaccessibleareas suchasceilingsor under oorswhere
the maintenance is not performed. Indoor wires may also be
used, however, in case where there is no risk of deterioration
due to exposure to heat, etc.
Note
Specificationsrelatedtoeachjunctionareasfollows.
Mini-clampconnector(N-8000EX/8010EXlineterminal)
Conductor diameter: ø0.4 – 0.65 mm (AWG22 – 26),
solid wire
Outside diameter: ø1.05 mm or below
Clip terminal (E-7000TB)
Conductor diameter: ø0.4 – 0.8 mm (AWG20 – 26),
solid wire
Outside diameter: ø1.5 mm or below
Terminalstation(LINE,H,Cterminals)
Conductor diameter: ø0.4 – 1.3 mm (AWG16 – 26),
solid wire, stranded wire
4.4. Relations Between Core Diameter of Cable and
Maximum Cable Length
Referring to the following chart as guidelines, design the
distance between the Exchange and stations so that loop
resistancebecomes170Ωorless.
Conductor
diameter
(mm)
Loop
resistance
(Ω/km)
Maximum cable length
between the Exchange and station.
(Assumingthattheloopresistanceis170Ω.)
ø0.4 295 570 m
ø0.5 187 900 m
ø0.65 113 1.5 km
ø0.9 58 2.9 km
4.5. Terminal Station Connection
Step 1. Stripacablejacketofapprox7mmtoexposeinner
cable.
For cables, refer to Type of Cable.
7 mm
Note
Do not solder plate on exposed inner cables when
using a stranded wire.
Step 2. Loosentheterminalscrewsandinsertthecables.
Step 3. Tighten the terminal screws securely.
Notes
• Tug lightly on the cable to be sure that it does not
pull free. If the cable pulls free, loosen the terminal
screw again and reconnect from Step 2.
• To avoid stripping the screws,
use the screwdriver appropriate
to the screws tightened into the
terminal plug.
4.6. Mini-clamp Connector Connection
Connect the mini-clamp connector supplied with the
N-8000EX/8010EXtoacableusingacommerciallyavailable
tool (pliers).
Step 1. Cut off two-cable ends in equal length, and insert
them securely to a cover section (transparent side)
of the mini-clamp connector.
Note
Insert the cable without stripping
thecablejacket.
Step 2. With a pair of pliers, lightly pinch the
mini-clamp cover and, after ensuring
that the cable is securely inserted,
rmlysqueezeonthecover.
Note
Squeeze on the mini-clamp cover until it is correctly
locked.
Step 3. Insertthewiredconnector(plug)intotheexchange’s
connector (socket) until it locks into place.
Cover
(transparent side)
Cable
N-8000EX/8010EX Rear panel
Tighten
Terminal screw
Cable
Warning
This is a class A product. In a domestic environment this
product may cause radio interference in which case the user
may be required to take adequate measures.

Other manuals for N-8050DS

2

Other Toa Intercom System manuals

Toa EXES 6000 CP-63 System manual

Toa

Toa EXES 6000 CP-63 System manual

Toa MS-900 User manual

Toa

Toa MS-900 User manual

Toa IC-100 Series System manual

Toa

Toa IC-100 Series System manual

Toa CP-62 System manual

Toa

Toa CP-62 System manual

Toa VS-900 User manual

Toa

Toa VS-900 User manual

Toa XRS-101SCS User manual

Toa

Toa XRS-101SCS User manual

Toa IC-100 Series Manual

Toa

Toa IC-100 Series Manual

Toa RS-160 User manual

Toa

Toa RS-160 User manual

Toa N-8500MS User manual

Toa

Toa N-8500MS User manual

Toa N-8052DS User manual

Toa

Toa N-8052DS User manual

Toa N-XC65-W User manual

Toa

Toa N-XC65-W User manual

Toa HF-640S User manual

Toa

Toa HF-640S User manual

Toa VS-900AL User manual

Toa

Toa VS-900AL User manual

Toa TD-600 User manual

Toa

Toa TD-600 User manual

Toa EX-16 System manual

Toa

Toa EX-16 System manual

Toa EXES-2000 User manual

Toa

Toa EXES-2000 User manual

Toa IP-A1 Series User guide

Toa

Toa IP-A1 Series User guide

Toa EXES-6000 CP-66 User manual

Toa

Toa EXES-6000 CP-66 User manual

Toa EXES-6000 CP-64 User manual

Toa

Toa EXES-6000 CP-64 User manual

Toa N-8050SB User manual

Toa

Toa N-8050SB User manual

Toa CCU-11B System manual

Toa

Toa CCU-11B System manual

Toa HF-670M User manual

Toa

Toa HF-670M User manual

Toa VS-900MF Installation and operating instructions

Toa

Toa VS-900MF Installation and operating instructions

Toa NF-2S User manual

Toa

Toa NF-2S User manual

Popular Intercom System manuals by other brands

NACD TVTEL 2K user guide

NACD

NACD TVTEL 2K user guide

Bpt LANDVRA/1-24 installation instructions

Bpt

Bpt LANDVRA/1-24 installation instructions

PRASTEL VISIODOOR2 installation manual

PRASTEL

PRASTEL VISIODOOR2 installation manual

Vimar Elvax 885E Installer's guide

Vimar

Vimar Elvax 885E Installer's guide

NACD SP214AM Installation operation & maintenance

NACD

NACD SP214AM Installation operation & maintenance

V-TEK DigiOpen 2Easy DMR18S Technical manual

V-TEK

V-TEK DigiOpen 2Easy DMR18S Technical manual

Aiphone NDA-20 instructions

Aiphone

Aiphone NDA-20 instructions

Contacta STS-K020 Installation & user guide

Contacta

Contacta STS-K020 Installation & user guide

Videx Kristallo Series manual

Videx

Videx Kristallo Series manual

Vimar ELVOX Tab Free 4.3 manual

Vimar

Vimar ELVOX Tab Free 4.3 manual

Vidos Duo M1022 user manual

Vidos

Vidos Duo M1022 user manual

Philips WelcomeEye Connect Pro 531022 user manual

Philips

Philips WelcomeEye Connect Pro 531022 user manual

Somogyi Elektronic DPV 24 instruction manual

Somogyi Elektronic

Somogyi Elektronic DPV 24 instruction manual

Telex 4030 user manual

Telex

Telex 4030 user manual

Kanrich S-913 SERIES user manual

Kanrich

Kanrich S-913 SERIES user manual

Aiphone AT-406 Installation & operation manual

Aiphone

Aiphone AT-406 Installation & operation manual

Electra Basic TL user manual

Electra

Electra Basic TL user manual

Elvox K40900 user guide

Elvox

Elvox K40900 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.