Toa IP-1000 Series User manual

Operation Manual
IP PoE Wall Mount Speaker
BS-PE678IP1
Thank you for purchasing TOA IP-1000 series products.
Please carefully read the instructions in this manual to ensure long-term and fault-free operation of the equipment.
TOA Corporation

Chapter 1
Safety Precautions

1-1
Chapter 1 Safety Precautions
Please observe the warnings and safety instructions.
After reading this manual, please properly place it for easy access and reference in the future.
Warning
This sign indicates that potential safety hazards would occur if the equipment is opened for operation
and serious injury or death would be caused to non-professionals who do not operate the equipment
properly.
This sign is used to alert users that the information attached to the equipment includes important
instructions of operation and maintenance (repair).
At setup and installation
(1) Preventing from water
Do not expose the equipment to rain or environment possibly contaminated by water or other liquids, or a
fire or electric shock may be caused.
(2) Applying the specified supply voltage
Be sure to apply the voltage indicated on the equipment.
If a voltage higher than the indicated voltage is applied, a fire or electric shock may be caused.
(3) Protecting the power cord
Do not scratch, cut or twist the power cord.
In addition, the power cord should be away from heating bodies. Do not place heavy objects (including the
equipment itself) on the power cord, or it may cause a fire or electric shock.
At operation
(1) In case of exceptions
Immediately cut off the power supply in case of the following exceptions during operation and contact the
dealer. If it continues to be used, a fire or electric shock may occur.
• Smoke or smell.
• Water or foreign bodies intrusion.
• Fall or case damage.
• Power cord damage (core is exposed or cord is broken).
• Unable to access to network or free of sounds, etc.
(2) Do not open the equipment or transform it.
Do not drop foreign bodies into the equipment.
Do not drop foreign bodies like metal or flammable objects into the equipment, or a fire or electric shock
may be caused.
(3) No touch at lightning
Do not touch the equipment and plugs at lightning to avoid electric shock.
(4) Do not place containers containing liquid or small metal objects above the equipment.
If a container is accidentally knocked over and the liquid flows into the equipment, a fire or electric shock
may be caused.

1-2
(5) Do not open the equipment or transform it.
High-voltage parts are installed in the equipment. If the equipment is uncovered or transformed, a fire or
electric shock may be caused. All maintenance and internal transformation of the equipment should be
performed by professionals.
(6) Precautions when maintenance or not used for a long time
When maintenance is performed or the equipment is not used for 10 days or more, shut off the power
and pull out the plug to ensure safety. If failing to observe this provision, a fire or electric shock would
occur.

Chapter 2
Product Description

2-1
Chapter 2 Product Description
2.1 Overview
2.1 Overview
BS-PE678IP1 is an IP PoE wall mount speaker and can receive the broadcast from other terminals or servers
supporting the setting of functions through browser. It can detect circuit faults and operating state of the speaker
and display them on the server software.
(1) Receiving broadcast sounds
BS-PE678IP1 can receive broadcast sounds from servers or other terminals.
(2) Time program broadcasting
It can upload the sounds required to be broadcast at various periods each day to the server and prepare
plans for broadcast. BS-PE678IP1 can achieve automatic broadcast according to the tasks scheduled by the
server.
(3) System setup through browser
Users can set up network,audio parameters and modify login password of the speaker through browser to
achieve personalized settings.
(4) External Power Supply input
BS-PE678IP1 can be powered via PoE or external DC24V power.
(5) Audio check
BS-PE678IP1 has a self-detection function and can detect the operating state of the speaker through circuit.
(6) Indicator light of operating status
BS-PE678IP1 is equipped with indicator lights of operating status and can quickly detect the operating state
of the speaker by recognizing the color and flashing of indicator lights.

2-2
Chapter 2Product Description
2.2 Terminal description
①Power Input connector: DC24V/1A is required, power supply input for network wall speaker. (Note: This
equipment supports POE power supply. If the network interface is connected to POE switch, no power supply is
needed)
"+" indicates the positive pole of DC24V, and "-" indicates the negative pole of DC24V power supply.
②Speaker Output connector: Extended speaker can be attached. When the network wall speaker receives the
broadcast, the same broadcast sound can be heard from the extended speaker.
③Network connector: The connector is RJ-45 standard, insert the network cable to connect the switch, so that
the equipment can login to the server normally. The network interface is equipped with two-color (green,
orange) indicator light, which can indicate the working status of the network wall-mounted loudspeaker. (Note:
This equipment supports POE power supply. If the network interface is connected to POE switch, no power
supply is needed)
Operating state
Indicator light
Power
-
on
The Orange light is ON
.
Network connection successful
The
Green light is ON.
Receiving broadcast
The green l
ight
is flashing.
Note: The Power Supply Input and Extended Speaker output interface are connected through 3.5-4P
terminal-block. The wiring steps are as follows:
Orange
Green
Power Input
①
Loo
sen
-
up
③Tighten
②Insert cables
Terminal
-
block
(3.5
-
4P)

Chapter 3
Wiring

3-2
Chapter 3 Wiring
3.1. Installation instructions
Required accessories
The required parts are attached as accessories.
Fixing screw M4×35 (2 pcs)
Step 1 Pull out the mask of BS-PE678IP1. Loosen
the two springs to separate the mask from the
bottom case.
Step 2 Install BS-PE678IP1 with the attached
fixing screws(M4*35).
Note:
BS-PE678IP1 can be installed horizontally or
vertically. Both concealed wiring (wiring inside
wall) and open wiring (wiring outside wall) are
applicable to BS-PE678IP1.
○
A Cable entry hole
(applicable to horizontal installation through
open wiring)
○
B Cable entry hole
(applicable to horizontal installation through
concealed wiring)
○
C Cable entry hole
(applicable to vertical installation through
concealed and open wiring)
Step 3 Re-install the mask on the bottom case.
Note: When BS-PE678IP1 is not aligned with its
trademark, gently pull up the trademark and
rotate it to a proper position.

3-3
Chapter 3 Wiring
3.2 Reference dimensions
Reference dimensions (unit: mm)

Chapter 4
System Setup Through Browser

4-2
Chapter 4 System Setup Through Browser
4.1 Access to browser
Step 1 Enter the IP address of BS-PE678IP1 (the default IP is 192.168.1.101) in the address field of IE
browser and press ENTER.
Step 2 Enter user name and password (the defaults are admin) in the login window on the Web page.
Note: User name and password are case sensitive.
Step 3 Press the OK button and then enter the Web page of BS-PE678IP1.

4-2
Chapter 4 System Setup Through Browser
4.2 Net options
Terminal IP IP address of BS-PE678IP1 (the default is 192.168.1.101)
Subnet mask Used to set the subnet mask (the default is 255.255.255.0).
Default gateway Used to set the gateway of BS-PE678IP1 (the default is 192.168.1.1).
DNS1 (Optional) Used to set the IP address of preferred DNS server of BS-PE678IP1.
DNS2 (Optional) Used to set the IP address of alternate DNS server of BS-PE678IP1.

4-2
Chapter 4 System Setup Through Browser
4.3 Server Options
Terminal ID This must be a unique number in the same system, do not duplicate with any
other terminals even for other models. The factory default ID number is 1.
Local Port The default terminal port number is 2046. Do not modify it without special
circumstances.
Primary Server IP address of a primary broadcasting server, the default port is 2048.
Secondary Server
When the primary server is unable to connect, the terminal can login to the
secondary server. After the primary server can be connected, the terminal
login to the primary server again.
Login Interval (s) Set the interval time in seconds that BS-PE678IP1 requests to login to the
server.

4-2
Chapter 4 System Setup Through Browser
4.4 SIP options
SIP Select for this activation.
SIP Server
The SIP server address where the terminal is located, please fill in the IP
address or domain name of the SIP server correctly. The port should not be
modified, except in special cases (default is 5060).
Account The SIP account of the terminal. This should not be duplicated with any other
terminals. This account number has to be set in the SIP server side.
Password The terminal login to a SIP server with this password. This password has to
be matched to the password which is set in the SIP server side.
Local Port Configure the local port according to the actual situation.
Audio Port Configure the audio port according to the actual situation.
Multicast Contact Select for this activation.
Multicast Address In the case of multiple servers in LAN, different servers must use different
addresses and port numbers for escaping any interference.

4-3
Chapter 4 System Setup Through Browser
4.5 Audio options
Broadcast Volume The total volume of the audio output of the terminal during broadcasting.
The value is from 0 (smaller) to 15 (louder).
Buffer time
This is for stable broadcasting output adjustment. When this value is small,
audio latency is small and it’s better for a live paging however if the network
is unstable, its audio would be so choppy. When this value is big, audio
latency is longer and it’s probably acceptable for a live paging in case that a
speaker (who makes announcement) is in a different location and this
situation is normal. And this big buffer makes its audio more stable.
Audio check
When the real-time noise of the terminal is less than or equal to the average
noise, the server will display the fault information by bouncing window.
Disabled for not enabling Audio check function;
Dynamic volume
adjust
When dynamic volume adjustment is enabled, the terminal will adjust the
output volume of broadcasting according to the noise level.
When disabled, the dynamic volume adjustment function is invalid, and the
"running status" page of the web page displays the real-time volume level.
Noise detect adjust
(dB)
Setting the noise detection adjustment value (default is 16 dB), the larger
the value, the larger the real-time noise value detected.
Note: The noise detection adjustment value = the noise decibel value
measured by the decibel meter when the calibration value is 0 - the average
noise decibel value detected by the terminal.
Noise
Reference(dB) Normal environment, noise average decibel value, default to 60 dB
Noise detect
interval (s)
Set the average noise detection interval time in second, default is 30sec..
The average noise varies according to the setting time.

4-4
Chapter 4 System Setup Through Browser
4.6 Password Setting
Users can modify login account and password in the web management parameters.
Original username Confirm the current account name.
Original password Confirm the current password.
New username Set the new account name, even this isn’t needed, this should be set.
New password Set the new password.
Password Confirm Confirm the new password.

4-4
Chapter 4 System Setup Through Browser
4.7 Language Setting
The language of the web page can be switched between Chinese and English.
If the language setting is set to Chinese, the following is a position of “Language Setting”.

4-4
Chapter 4 System Setup Through Browser
4.8 Update firmware
Press the "Update" button. Firmware upgrade mode will be entered in 15 seconds. Click "Browse", select
the upgrade file provided by the manufacturer, and press "Update" to start firmware update.
Note: Do not turn off the power during upgrading the terminal, otherwise it may lead to the failure of the
upgrade and the failure of the equipment.

4-4
Chapter 4 System Setup Through Browser
4.9 Factory reset
Restore factory settings: All parameters are restored to factory settings.
Factory reset
Other manuals for IP-1000 Series
4
This manual suits for next models
1
Table of contents
Other Toa Speakers manuals
Popular Speakers manuals by other brands

MB QUART
MB QUART PREMIUM PCE 164 PCE164 PCE164 installation manual

Sound Tube
Sound Tube RS31-EZ-T Install instructions

B2 Audio
B2 Audio BM402C owner's manual

Silvercrest
Silvercrest SBLL 56 A1 operating instructions

E-matic
E-matic ESB107 user manual

Sound Sation
Sound Sation GO-SOUND AMW series user manual