INSTALLATION INSTRUCTIONS
WARNING
Turn the power off at the circuit breaker before installing
the timer.
Read and understand these instructions before installing. This device is intended for installation
in accordance with the National Electric Code and local regulations. It is recommended that a
qualified electrician performs this installation. Make sure to turn off the circuit breaker or fuse(s)
and make sure power is off before wiring the device.
Use copper wire only.
Model: TDHOS5
Dual Technology Humidity/PIR Motion Sensor
with Interchangeable Face Cover
Power..............................................................................................120VAC, 60Hz
Maximum fan load.......................................................................................3 Amps
Incandescent maximum..........................................................................500 Watts
Fluorescent maximum..................................................................................400VA
LED maximum.........................................................................................150 Watts
..............................................................................*minimum light load of 10 Watts
Light and Fan Time Delay......................................15s, 10 mins, 20 mins, 30 mins
Humidity range..................................................................................45%-80% RH
PIR coverage.............................................................................................600sq.ft
SPECIFICATIONS
As illustrated in Figure 1, The TDHOS5 has a 180° detection range with a maximum distance
of 24’ detection in front of the sensor and 12' on the sides. For maximum results, the sensor
must be properly installed between the height of 4’ to 5’ and away from obstructions such as
walls, furniture and transparent barriers like Low-E glass.
Figure 1
Max. 12'
on the sides
Max. 24'
from front
Installation
Height: 4' - 5'
Detection Range
COVERAGE
Figure 2
HOT
Black
Figure 3
1. 2.
How to change the color cover/ push button.
The switch comes with the top cover attached. Remove the wall plate if
necessary, then the cover may be changed as follow:
REMOVAL
Push down on the cover/ push
button to release, then pull away
from main body.
REATTACH
Align the latch pins to the unit,
push the cover/ button against
the main body, then slide up until
its locked into place
White
Neutral
White
Neutral
Red
Light
Brown
Fan
Green
Ground
Blue
Line 2
HOT
Black
Line 1
HOT
1. Connect RED wire from sensor to the LIGHT wire.
2. Connect BROWN wire from sensor to the FAN wire.
3. Connect BLACK AND BLUE wire from sensor to the HOT wire.
4. Connect WHITE wire from sensor to the NEUTRAL wire.
5. Connect GREEN wire from sensor to the GROUND wire.
Single Pole
Wiring Diagram
OPERATING INSTRUCTIONS
The TDHOS5 features two adjustable operation modes for customized control to suit the
specific ventilation and lighting needs of the room. These modes are as follows; Occupancy with
Automatic Humidity and Vacancy with Automatic Humidity.
The count-down timer can also be adjusted to set the minimum "ON" time for the lights at 10
minutes, 20 minutes, or 30 minutes. The fan will automatically turn on depend on the preset
humidity. Once the Timer has been set, the switch will automatically turn the lights off when the
selected time has expired. However the fan will continue to operate if the sensor detects excess
humidity. The Fan will Automatically turn off after the humidity level is reached.
The sensor switch is equipped with adjustable humidity levels. The humidity sensor can be
adjusted to low, medium, or high level.
When the PIR sensor detects movement the light button's green LED indicator will be flashing.
The fan's LED will turn red when the sensor detects excess humidity in a room; otherwise, it will
always stay lit in white.
Press and hold both light and fan buttons for 10 seconds, the green LED indicator will
come on solid. This setting allows users to switch back and forth between Occupancy
and Vacancy Mode.
•
Occupancy Mode* - Auto On/Automatic Off Lights. Auto On/Automatic Off Fan
base on preset humidity level.
o
Light: Auto On, Auto Off. The Light will automatically turn ON by PIR sensor.
Auto OFF by Time Delay.
When manual button is used to turn ON, lights turn ON and then turn OFF by
preset time delay.
When manual button is used to turn OFF before the preset timer expired, lights
turn off completely. After 3 minutes, PIR preset timer will resets and lights turn ON
if motion is detected.
o
Fan: Auto On, Auto Off. The Fan will turn ON automatically when preset humidity
level is reached and automatically turn OFF when the humidity level drops below
the preset.
If the humidity level is higher than preset then the fan will continue to run after a 5
minutes break.
When the manual button is used to turn ON, the fan will turn ON for 30 minutes
and automatically turn OFF.
When the manual button is used to turn OFF before the 30 minutes, the fan will
turn OFF immediately and the humidity sensor will stop detecting. Only when the
manual button is used to turn ON again, after 30 minutes the humidity sensor will
be operational again.
•
Vacancy Mode - Manual On/Automatic Off Lights. Auto On/Automatic Off Fan
base on preset humidity level
o
Light: Manual On, Auto Off. Manual button is used to turn the Lights ON and
Lights turn OFF automatically after preset time delay. If motion is detected (within
30 seconds) of the lights turning off, the Lights will remain ON
123
© 2016 TOPGREENER, Inc. ● CA, U.S.A. ● WWW.TOPGREENER.COM ● 0103170082-05
WARRANTY
This device is warranted to be free of material and workmanship defects for 1 year from the date of purchase. Original receipt or proof of purchase from an authorized retailer must be presented
upon warranty claim. ALL claims must be verified and approved by Top Greener, Inc. Warranties from other Top Greener products may vary. This warranty is nontransferable and does not cover
normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper installation. To the fullest extent permitted by the applicable
state law, Top Greener shall not be liable to the purchaser or end user customer of Top Greener products for direct, indirect, incidental, or consequential damages even if Top Greener has been
advised of the possibility of such damages. Top Greener’ total liability under this or any other warranty, express or implied, is limited to repair, replacement or refund. Repair, replacement or
refund are the sole and exclusive remedies for breach of warranty or any other legal theory.
TROUBLESHOOTING
The switch buttons are not functional
Check if the device is wired properly. This device requires a NEUTRAL wire for
operation. Often the WHITE wire is used as a LOAD wire. Be sure to test ALL
wires. Also make sure that the HOT and LOAD wires are not reversed.
Press the Light or the Fan button:
•If the load does not work and the indicator light does not flash.
TURN OFF the power at the circuit breaker then check wire
connections. Confirm that the NEUTRAL wire is connected and Black
AND Blue leads are connected to the incoming HOT wire.
•
•
If the humidity sensor does not turn on the fan.
Change the humidity level to match the appropriate condition or manually
turn ON the fan, after 30 minutes the humidity sensor will be operational.
If the light does not turn on but the indicator light is flashing .
The switch is in Vacancy Mode.
Programming Example: Change the time delay of the switch from 10
minutes to 20 minutes as follows:
1. Press and hold the light button for eight seconds. The green LED light
will come on solid.
2. Press the light button once for Function 1: Time Delay.
3. The green LED light will now flash once every 2 seconds indicating the
current time delay, which is at 10 minutes.
Press the light button two times to choose Setting 2 (20 minutes). The
green LED light now will flashes two times every 2 seconds indicating
the new time delay of 20 minutes.
Press and Hold the light button for eight seconds. The LED light will
flash 3 times indicating that the settings are saved then the load will
turn OFF.
STEP 1: Enter Programming Mode
•Press and hold the light button for eight seconds until the solid green LED
lights up (the LED will stay on). The sensor is now in programming mode.
STEP 2: Choose the Function
•Press the light button the same number of times as the Function Number you
would like to program.
oAfter the last button is pressed the sensor will flash back the current
setting for that function10 times at two-second intervals. If no
selection has been made, the device will exit programming mode.
STEP 3: Choose the Setting
•Press the light button the same number of times as the Setting Number for
that function (For example in Function 1: Press the button 2 times to select 20
minutes).
oAfter the last button is pressed the sensor will flash back the current
setting for that function10 times at two-second intervals. If no
selection has been made, the device will exit programming mode.
STEP 4: Save the Settings
•Press and Hold the light button for eight seconds. The LED light will flash
3 times indicating that the settings are saved then the load will turn OFF.
PROGRAMMING
During programming, ONLY the Light Button will be used. Pay close
attention to the Green LED lights as it will flash to indicate
successful programming steps. The LED will also flash each time
the button is pressed while making the selections. Once the
program is saved, the load will turn OFF.
After each step, there are only 20 seconds to make the next
programming selection. If a selection has not been made, time will
expire and the LED light will flash 3 times and exit programming
mode.
There are 2 Programmable Functions:
•Function 1: Time Delay
•Function 2: Humidity Level
FUNCTIONS/SETTINGS
Factory default settings are indicated with (*)
Function 1: Time Delay for the light and fan
•Setting 1: 15 seconds (*)
After 5 minutes, the switch will automatically set to 10 minutes
•Setting 2: 20 minutes
•Setting 3: 30 minutes
EXAMPLE
Function 2: Humidity level (Humidity Range 45% - 80%)
•Setting 1: Low humidity sensitivity 45% (requires little humidity to
trigger)
•Setting 2: Medium humidity sensitivity 65% (*)
•Setting 3: High humidity sensitivity 80% (requires high humidity to
trigger)
OPERATING INSTRUCTIONS Cont.
oFan: Auto On, Auto Off. The Fan will turn ON automatically when
preset humidity level is reached and automatically turn OFF when the
humidity level drops below the preset.
If the humidity level is higher than preset then the fan will continue to
run after a 5 minutes break.
When the manual button is used to turn ON, the fan will turn ON for
30 minutes and automatically turn OFF.
When the manual button is used to turn OFF before the 30 minutes,
the fan will turn OFF immediately and the humidity sensor will stop
detecting. Only when the manual button is used to turn ON again,
after 30 minutes the humidity sensor will be operational again.
456

Other Topgreener Accessories manuals

Topgreener TDOS5 User manual

Topgreener

Topgreener TDOS5 User manual

Topgreener TDHOS5 User manual

Topgreener

Topgreener TDHOS5 User manual

Topgreener TDOS5 User manual

Topgreener

Topgreener TDOS5 User manual

Topgreener TDODS5-120 User manual

Topgreener

Topgreener TDODS5-120 User manual

Popular Accessories manuals by other brands

FLAMMA CARAVANSTORE Installation and usage instructions

FLAMMA

FLAMMA CARAVANSTORE Installation and usage instructions

EVE Motion Get started

EVE

EVE Motion Get started

Thermo Scientific Cytomat 2 manual

Thermo Scientific

Thermo Scientific Cytomat 2 manual

JBL Endurance Race quick start guide

JBL

JBL Endurance Race quick start guide

PASCO PS-2154A instruction sheet

PASCO

PASCO PS-2154A instruction sheet

Clip Sonic TEA134 instructions

Clip Sonic

Clip Sonic TEA134 instructions

Omega Engineering LVRD500 Series instruction sheet

Omega Engineering

Omega Engineering LVRD500 Series instruction sheet

Kompernass KH 1143 operating instructions

Kompernass

Kompernass KH 1143 operating instructions

Orno OR-CR-220 quick start guide

Orno

Orno OR-CR-220 quick start guide

Panasonic HL-C203B instruction manual

Panasonic

Panasonic HL-C203B instruction manual

BOMANN WUB 895 CB Instruction manual and guarantee

BOMANN

BOMANN WUB 895 CB Instruction manual and guarantee

Graco Latch EZ instruction manual

Graco

Graco Latch EZ instruction manual

Festo Pneumatic SFL-6 operating instructions

Festo Pneumatic

Festo Pneumatic SFL-6 operating instructions

Omron fh-3 series Reference manual

Omron

Omron fh-3 series Reference manual

REED 5T user manual

REED

REED 5T user manual

Omron E3Z-LT manual

Omron

Omron E3Z-LT manual

Oval LSF38 Series instructions

Oval

Oval LSF38 Series instructions

Gibus MEDITERRANEA Series Use and maintenance manual

Gibus

Gibus MEDITERRANEA Series Use and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.