© 2016 TOPGREENER, Inc. ● CA, U.S.A. ● WWW.TOPGREENER.COM ● 0103170082-05
WARRANTY
This device is warranted to be free of material and workmanship defects for 1 year from the date of purchase. Original receipt or proof of purchase from an authorized retailer must be presented
upon warranty claim. ALL claims must be verified and approved by Top Greener, Inc. Warranties from other Top Greener products may vary. This warranty is nontransferable and does not cover
normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper installation. To the fullest extent permitted by the applicable
state law, Top Greener shall not be liable to the purchaser or end user customer of Top Greener products for direct, indirect, incidental, or consequential damages even if Top Greener has been
advised of the possibility of such damages. Top Greener’ total liability under this or any other warranty, express or implied, is limited to repair, replacement or refund. Repair, replacement or
refund are the sole and exclusive remedies for breach of warranty or any other legal theory.
TROUBLESHOOTING
The switch buttons are not functional
Check if the device is wired properly. This device requires a NEUTRAL wire for
operation. Often the WHITE wire is used as a LOAD wire. Be sure to test ALL
wires. Also make sure that the HOT and LOAD wires are not reversed.
Press the Light or the Fan button:
•If the load does not work and the indicator light does not flash.
TURN OFF the power at the circuit breaker then check wire
connections. Confirm that the NEUTRAL wire is connected and Black
AND Blue leads are connected to the incoming HOT wire.
•
•
If the humidity sensor does not turn on the fan.
Change the humidity level to match the appropriate condition or manually
turn ON the fan, after 30 minutes the humidity sensor will be operational.
If the light does not turn on but the indicator light is flashing .
The switch is in Vacancy Mode.
Programming Example: Change the time delay of the switch from 10
minutes to 20 minutes as follows:
1. Press and hold the light button for eight seconds. The green LED light
will come on solid.
2. Press the light button once for Function 1: Time Delay.
3. The green LED light will now flash once every 2 seconds indicating the
current time delay, which is at 10 minutes.
Press the light button two times to choose Setting 2 (20 minutes). The
green LED light now will flashes two times every 2 seconds indicating
the new time delay of 20 minutes.
Press and Hold the light button for eight seconds. The LED light will
flash 3 times indicating that the settings are saved then the load will
turn OFF.
STEP 1: Enter Programming Mode
•Press and hold the light button for eight seconds until the solid green LED
lights up (the LED will stay on). The sensor is now in programming mode.
STEP 2: Choose the Function
•Press the light button the same number of times as the Function Number you
would like to program.
oAfter the last button is pressed the sensor will flash back the current
setting for that function10 times at two-second intervals. If no
selection has been made, the device will exit programming mode.
STEP 3: Choose the Setting
•Press the light button the same number of times as the Setting Number for
that function (For example in Function 1: Press the button 2 times to select 20
minutes).
oAfter the last button is pressed the sensor will flash back the current
setting for that function10 times at two-second intervals. If no
selection has been made, the device will exit programming mode.
STEP 4: Save the Settings
•Press and Hold the light button for eight seconds. The LED light will flash
3 times indicating that the settings are saved then the load will turn OFF.
PROGRAMMING
During programming, ONLY the Light Button will be used. Pay close
attention to the Green LED lights as it will flash to indicate
successful programming steps. The LED will also flash each time
the button is pressed while making the selections. Once the
program is saved, the load will turn OFF.
After each step, there are only 20 seconds to make the next
programming selection. If a selection has not been made, time will
expire and the LED light will flash 3 times and exit programming
mode.
There are 2 Programmable Functions:
•Function 1: Time Delay
•Function 2: Humidity Level
FUNCTIONS/SETTINGS
Factory default settings are indicated with (*)
Function 1: Time Delay for the light and fan
•Setting 1: 15 seconds (*)
After 5 minutes, the switch will automatically set to 10 minutes
•Setting 2: 20 minutes
•Setting 3: 30 minutes
EXAMPLE
Function 2: Humidity level (Humidity Range 45% - 80%)
•Setting 1: Low humidity sensitivity 45% (requires little humidity to
trigger)
•Setting 2: Medium humidity sensitivity 65% (*)
•Setting 3: High humidity sensitivity 80% (requires high humidity to
trigger)
OPERATING INSTRUCTIONS Cont.
oFan: Auto On, Auto Off. The Fan will turn ON automatically when
preset humidity level is reached and automatically turn OFF when the
humidity level drops below the preset.
If the humidity level is higher than preset then the fan will continue to
run after a 5 minutes break.
When the manual button is used to turn ON, the fan will turn ON for
30 minutes and automatically turn OFF.
When the manual button is used to turn OFF before the 30 minutes,
the fan will turn OFF immediately and the humidity sensor will stop
detecting. Only when the manual button is used to turn ON again,
after 30 minutes the humidity sensor will be operational again.
456