456
WARRANTY INFORMATION
TROUBLESHOOTING
OPERATION
This device is warranted to be free of material and workmanship defects for 2 years from the
date of purchase. Original receipt or proof of purchase from an authorized retailer must be
presented upon warranty claim. ALL claims must be verified and approved by Top Greener,
Inc. Warranties from other Top Greener products may vary. This warranty is nontransferable
and does not cover normal wear and tear or any malfunction, failure, or defect resulting from
misuse, abuse, neglect, alteration, modification, or improper installation. To the fullest
extent permitted by the applicable state law, Top Greener shall not be liable to the purchaser
or end user customer of Top Greener products for direct, indirect, incidental, or
consequential damages even if Top Greener has been advised of the possibility of such
damages. Top Greener’ total liability under this or any other warranty, express or implied, is
limited to repair, replacement or refund. Repair, replacement or refund are the sole and
exclusive remedies for breach of warranty or any other legal theory.
© 2016 Top Greener Inc.
CA, U.S.A.
WWW.TOPGREENER.COM
0206160005
Off/ Occupancy/ Vacancy Mode Switch
The OFF position: Switch is turned off and will not detect motion. The push button will
not function.
OCCupancy position: The load will automatically turn on when motion is detected and
automatically turn off when the selected time delay has expired. The push button may be
used to manually turn ON/OFF the load and time delay will also take effect.
VACancy position: The load will turn on ONLY when the push button is used and
automatically turn off when the selected time delay has expired. The push button may be
used to manually turn ON/OFF the load and time delay will also take effect. If the time
delay has expired and the load turns off, the load will turn on again automatically if motion
is detected within 30 seconds.
The Load Flashes when switch is turned on:
Check the wire connection. Make sure the WHITE wire on the sensor
is connected to the NEUTRAL wire in the junction box. DO NOT
connect the WHITE wire on the sensor to any other wire besides
NEUTRAL.
DO NOT connect the WHITE (Neutral) wire and the RED (Load) wire
on the sensor together. Otherwise, the load will keep flashing.
The Load does not turn on when motion is detected:
1. Keep close to the sensor to make sure you are in the detection range.
2. Check the LED indicator on the sensor to see whether it flashes when motion is
detected. If LED indicator flashes when motion detected, please go to Step 3. If LED
indicator stays off when there is motion, please go to Step 4.
3. Make sure the sensor is in 'OCC' mode.
4. Check the wiring connection to make sure neutral wire has been connected and make
sure Hot and Load wires are not reversely connected.
The Load does not turn off:
1. Manually push the button to turn off the light. If the light keeps on, please go to step 4. If
the light is turned off, please go to step 2.
2. heck the time delay option. The time delay constantly restarts its countdown after the
last motion detected. Turn the Time Delay Knob to 15s (Test Mode) and make sure
there is no motion (Tape may be used to cover the fresnel lens while testing.)
3. Check for possible significant heat sources emitting within six feet (two meters) such as
high wattage light bulbs, portable heaters or HAVC vents which may be triggering the
sensor.
4. Check the wiring. Make sure no connection between Hot wire and Load.
The Load turns on when not desired:
1. Make sure there is no motion detected by the sensor.
2. Check for possible significant heat sources emitting within six feet (two meters) such as
high wattage light bulbs, portable heaters or HAVC vents which may be triggering the
sensor.
3. If the sensor is installed in a small room, turn the Range dial to a lower setting to avoid
false or unwanted detection from a open window or door.
4. Choose to use VAC mode instead of OCC mode to avoid false triggering.