WARRANTY
© 2018 Top Greener, Inc. CA, U.S.A. WWW.TOPGREENER.COM 0211200082-07
This device is warranted to be free of material and workmanship defects for 1 year from the date of purchase. Original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim. ALL claims
must be verified and approved by Top Greener, Inc. Warranties from other TOPGREENER products may vary. This warranty is nontransferable and does not cover normal wear and tear or any malfunction, failure, or defect
resulting from misuse, abuse, neglect, alteration, modification, or improper installation. To the fullest extent permitted by the applicable state law, Top Greener, Inc. shall not be liable to the purchaser or end user customer of
TOPGREENER products for direct, indirect, incidental, or consequential damages even if Top Greener, Inc. has been advised of the possibility of such damages. Top Greener, Inc’s total liability under this or any other warranty,
express or implied, is limited to repair, replacement or refund. Repair, replacement or refund are the sole and exclusive remedies for breach of warranty or any other legal theory.
•
If the switch does not seem to turn on (
If the load does not work and the
indicator light does not flash).
1. Press and hold the light button for eight seconds. The green LED light
will come on solid.
2. Press the light button once for Function 1: Time Delay.
3. The green LED light will now flash once every 2 seconds indicating the
current time delay, which is at 10 minutes.
Press the light button 2 times to choose Setting 2 (20 minutes).
The green LED light now will flashes two times every
2 seconds indicating the new time delay of 20 minutes.
4. Press and Hold the light button for eight seconds. The LED light will
flash 3 times indicating
that the settings are saved then the load will turn OFF.
Check if the device is wired properly. It requires a NEUTRAL wire for
operation. Often the WHITE wire is used as a LOAD wire for the light and
is indicated by a black electrical tape wrapped around the wire. Be sure
that the Black AND Blue leads are connected to the incoming HOT wire.
Also make sure that the HOT and LOAD wires are not reversed.
TROUBLESHOOTING
EXAMPLE
Programming Example: Change the time delay of the switch from
10 minutes to 20 minutes as follows:
• Occupancy Mode (default) - Lights Auto On/Automatic Off
OCCUPANCY/VACANCY MODES
Users can change between occupancy and vacancy modes by pressing and
holding the light and fan buttons simultaneously for about 10 to 15 seconds.
When the green LED indicator on the light button comes on, it indicates the
mode has been changed from either occupancy to vacancy or vacancy to
occupancy mode.
The fan only has one mode: Auto On, Auto Off. The fan will turn ON
automatically when the humidity level reaches the selected (high, medium,
or low) level and will automatically turn OFF when the humidity level drops
low enough
FAN MODES
NOTES
What is Time Delay
• For the PIR motion sensor, time delay is the time from the last
motion detected until the light is automatically turned OFF
• The fan has only one time setting and that is to run in 30 minute
intervals. Anytime the fan comes on whether by use of the button or
automatically, the fan will run for only 30 minutes. If humidity in the
room is still at a high level after running for 30 minutes, the TDHOS5
will pause for 5 minutes and resume for another 30 minutes.
Light: Auto On, Auto Off. The Lights will automatically turn ON when
motion is detected and automatically turn OFF by Time Delay.
• When the light button is used to turn ON, lights turn ON. The
lights will then turn OFF when the time delay expires.
• When manual button is used to turn OFF the lights before the
timer expires, the lights turn off. The sensor will not turn the lights
on again for another 3 minutes. After 3 minutes, the sensor will
reset and will turn ON lights if motion is detected.
Light: Manual On, Auto Off. Manual button is used to turn the Lights ON
and automatically turn OFF by Time Delay.
• When manual button is used to turn OFF the lights before the
timer expires, the lights turn off. The sensor will not turn the lights
on again
• If motion is detected (within 30 seconds) of the lights turning off,
the Lights will come back ON
• Vacancy Mode - Lights Manual On/Automatic Off
• After running for 30 minutes, if the humidity level has not dropped low
enough, the fan will pause for 5 minutes, then resume for another
30 minutes.
• This is a feature that prevents the motor on the ventilation fan
from overheating
• When the manual button is used to turn ON, the fan will turn ON for
30 minutes and automatically turn OFF.
• Overriding the fan’s Auto On function: When the manual button is
used to turn OFF the fan, the fan will turn OFF immediately and the
humidity sensor will stop detecting humidity until it is reset by the user.
• This is a great feature if you live in areas with very high humidity
and you don’t want the fan to come on throughout the night
• To Reset the fan’s Auto On function: Use the fan button to turn ON the
fan and allow it to turn off on it’s own (30 minutes).
High Relative Humidity (RH) locations
• If you live in high humidity areas, consider using the highest
humidity setting (Function 2, setting 3). If the fan runs non-stop even
with setting 3 selected, you should override the auto-on until the
relative humidity (RH) in your area drops below 80% RH.
LED indicators
• The Light LED indicator will flash green when motion is detected.
• The Fan LED indicator will turn solid red when humidity is detected.
If the manual button is used and no humidity is detected, the LED
indicator will stay white.
• If the humidity sensor does not turn on the fan, but the fan button works.
Change the humidity level to a lower setting. Then reset the fan by using the
fan button to manually turn ON the fan. Wait 30 minutes for the fan to turn off.
The humidity sensor will reset after the 30 minutes.
• If the light does not turn on but the indicator light is flashing .
The switch may be in Vacancy Mode. Press and hold both light and fan
buttons for 10 seconds to switch to Occupancy mode.