– 9 –
<Cooling> RAS-M18GAV-E , RAS-M18GACV-E
<Heating>RAS-M18GAV-E
The above specification values are those under the conditions.
Cooling Indoor : DB/WB=27/19°C Heating Indoor : DB=20°C
Outdoor : DB=35°C Outdoor : DB/WB=7/6°C
Volts Operating indoor unit Unit capacity (kW) Capacity Running current Power Consumption
Operation
mode VOperation
status ABAB kW A W
10 — 2.70— 2.7 (1.1 to 3.2) 3.03 (1.43 to 03.83) 0600 (220 to 0800)
13 — 3.70— 3.7 (1.1 to 4.2) 5.10 (1.43 to 06.49) 1100 (220 to 1400)1 unit
16 — 4.50— 4.5 (1.1 to 4.9) 6.96 (1.43 to 07.88) 1500 (220 to 1700)
10 10 2.55 2.55 5.1 (1.4 to 6.1) 7.19 (1.69 to 09.97) 1550 (260 to 2150)
13 10 2.85 2.35 5.2 (1.4 to 6.2) 7.42 (1.69 to 10.06) 1600 (260 to 2170)
13 13 2.60 2.60 5.2 (1.4 to 6.2) 7.42 (1.69 to 10.06) 1600 (260 to 2170)
220
2 units
16 10 3.25 1.95 5.2 (1.4 to 6.2) 7.42 (1.69 to 10.06) 1600 (260 to 2170)
10 — 2.70— 2.7 (1.1 to 3.2) 2.90 (1.37 to 03.66) 0600 (220 to 0800)
13 — 3.70— 3.7 (1.1 to 4.2) 4.88 (1.37 to 06.21) 1100 (220 to 1400)1 unit
16 — 4.50— 4.5 (1.1 to 4.9) 6.65 (1.37 to 07.54) 1500 (220 to 1700)
10 10 2.55 2.55 5.1 (1.4 to 6.1) 6.88 (1.61 to 09.54) 1550 (260 to 2150)
13 10 2.85 2.35 5.2 (1.4 to 6.2) 7.10 (1.61 to 09.63) 1600 (260 to 2170)
13 13 2.60 2.60 5.2 (1.4 to 6.2) 7.10 (1.61 to 09.63) 1600 (260 to 2170)
230
2 units
16 10 3.25 1.95 5.2 (1.4 to 6.2) 7.10 (1.61 to 09.63) 1600 (260 to 2170)
10 — 2.70— 2.7 (1.1 to 3.2) 2.78 (1.31 to 03.51) 0600 (220 to 0800)
13 — 3.70— 3.7 (1.1 to 4.2) 4.68 (1.31 to 05.95) 1100 (220 to 1400)
1 unit
16 — 4.50— 4.5 (1.1 to 4.9) 6.38 (1.31 to 07.23) 1500 (220 to 1700)
10 10 2.55 2.55 5.1 (1.4 to 6.1) 6.59 (1.55 to 09.14) 1550 (260 to 2150)
13 10 2.85 2.35 5.2 (1.4 to 6.2) 6.80 (1.55 to 09.23) 1600 (260 to 2170)
13 13 2.60 2.60 5.2 (1.4 to 6.2) 6.80 (1.55 to 09.23) 1600 (260 to 2170)
Cooling
240
2 units
16 10 3.25 1.95 5.2 (1.4 to 6.2) 6.80 (1.55 to 09.23) 1600 (260 to 2170)
Volts Operating indoor unit Unit capacity (kW) Capacity Running current Power Consumption
Operation
mode VOperation
status ABAB kW A W
10 — 4.00— 4.0 (0.7 to 5.2) 5.57 (1.10 to 07.88) 1200 (170 to 1700)
13 — 5.00— 5.0 (0.7 to 6.5) 8.35 (1.10 to 11.73) 1800 (170 to 2530)1 unit
16 — 5.50— 5.5 (0.7 to 6.9) 8.81 (1.10 to 11.73) 1900 (170 to 2530)
10 10 3.25 3.25 6.5 (0.9 to 8.2) 8.35 (1.30 to 11.09) 1800 (200 to 2390)
13 10 3.51 3.19 6.7 (0.9 to 8.5) 8.58 (1.30 to 11.36) 1850 (200 to 2450)
13 13 3.35 3.35 6.7 (0.9 to 8.5) 8.58 (1.30 to 11.36) 1850 (200 to 2450)
220
2 units
16 10 3.88 2.82 6.7 (0.9 to 8.5) 8.58 (1.30 to 11.36) 1850 (200 to 2450)
10 — 4.00— 4.0 (0.7 to 5.2) 5.32 (1.06 to 07.54) 1200 (170 to 1700)
13 — 5.00— 5.0 (0.7 to 6.5) 7.99 (1.06 to 11.22) 1800 (170 to 2530)1 unit
16 — 5.50— 5.5 (0.7 to 6.9) 8.43 (1.06 to 11.22) 1900 (170 to 2530)
10 10 3.25 3.25 6.5 (0.9 to 8.2) 7.99 (1.24 to 10.60) 1800 (200 to 2390)
13 10 3.51 3.19 6.7 (0.9 to 8.5) 8.21 (1.24 to 10.87) 1850 (200 to 2450)
13 13 3.35 3.35 6.7 (0.9 to 8.5) 8.21 (1.24 to 10.87) 1850 (200 to 2450)
230
2 units
16 10 3.88 2.82 6.7 (0.9 to 8.5) 8.21 (1.24 to 10.87) 1850 (200 to 2450)
10 — 4.00— 4.0 (0.7 to 5.2) 5.10 (1.01 to 07.23) 1200 (170 to 1700)
13 — 5.00— 5.0 (0.7 to 6.5) 7.65 (1.01 to 10.76) 1800 (170 to 2530)
1 unit
16 — 5.50— 5.5 (0.7 to 6.9) 8.08 (1.01 to 10.76) 1900 (170 to 2530)
10 10 3.25 3.25 6.5 (0.9 to 8.2) 7.65 (1.19 to 10.16) 1800 (200 to 2390)
13 10 3.51 3.19 6.7 (0.9 to 8.5) 7.87 (1.19 to 10.42) 1850 (200 to 2450)
13 13 3.35 3.35 6.7 (0.9 to 8.5) 7.87 (1.19 to 10.42) 1850 (200 to 2450)
Heating
240
2 units
16 10 3.88 2.82 6.7 (0.9 to 8.5) 7.87 (1.19 to 10.42) 1850 (200 to 2450)